Search NASASearch

SEARCH · Search NASA

Results for “sample handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mars Sample Handling and Requirements Panel (MSHARP)

In anticipation of the return of samples from Mars toward the end of the first decade of the next century, NASA's Office of Space Sciences chartered a panel to examine how Mars samples should be handled. The panel was to make recommendations in three areas: (1) sample collection and transport back to Earth; (2) certification of the samples as nonhazardous; and (3) sample receiving, curation, and distribution. This report summarizes the findings of that panel. The samples should be treated as hazardous until proven otherwise. They are to be sealed within a canister on Mars, and the canister is not to be opened until within a Biosafety Hazard Level 4 (BSL-4) containment facility here on Earth. This facility must also meet or exceed the cleanliness requirements of the Johnson Space Center (JSC) facility for curation of extraterrestrial materials. A containment facility meeting both these requirements does not yet exist. Hazard assessment and life detection experiments are to be done at the containment facility, while geochemical characterization is being performed on a sterilized subset of the samples released to the science community. When and if the samples are proven harmless, they are to be transferred to a curation facility, such as that at JSC.

Carr, Michael H.

Mars Sample Handling Protocol Workshop Series: Workshop 2

Numerous NASA reports and studies have identified Planetary Protection (PP) as an important part of any Mars sample return mission. The mission architecture, hardware, on-board experiments, and related activities must be designed in ways that prevent both forward- and back-contamination and also ensure maximal return of scientific information. A key element of any PP effort for sample return missions is the development of guidelines for containment and analysis of returned sample(s). As part of that effort, NASA and the Space Studies Board (SSB) of the National Research Council (NRC) have each assembled experts from a wide range of scientific fields to identify and discuss issues pertinent to sample return. In 1997, the SSB released its report on recommendations for handling and testing of returned Mars samples. In particular, the NRC recommended that: a) samples returned from Mars by spacecraft should be contained and treated as potentially hazardous until proven otherwise, and b) rigorous physical, chemical, and biological analyses [should] confirm that there is no indication of the presence of any exogenous biological entity. Also in 1997, a Mars Sample Quarantine Protocol workshop was convened at NASA Ames Research Center to deal with three specific aspects of the initial handling of a returned Mars sample: 1) biocontainment, to prevent 'uncontrolled release' of sample material into the terrestrial environment; 2) life detection, to examine the sample for evidence of organisms; and 3) biohazard testing, to determine if the sample poses any threat to terrestrial life forms and the Earth's biosphere. In 1999, a study by NASA's Mars Sample Handling and Requirements Panel (MSHARP) addressed three other specific areas in anticipation of returning samples from Mars: 1) sample collection and transport back to Earth; 2) certification of the samples as non-hazardous; and 3) sample receiving, curation, and distribution. To further refine the requirements for sample hazard testing and the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened an additional series of workshops beginning in March 2000. The overall objective of these workshops was to develop comprehensive protocols to assess whether the returned materials contain any biological hazards, and to safeguard the purity of the samples from possible terrestrial contamination. This document is the report of the second Workshop in the Series. The information herein will ultimately be integrated into a final document reporting the proceedings of the entire Workshop Series along with additional information and recommendations.

Rummel, John D.

Sample Handling in Extreme Environments

Harsh environments, such as that on Venus, preclude the use of existing equipment for functions that involve interaction with the environment. The operating limitations of current high temperature electronics are well below the actual temperature and pressure found on Venus (460 deg C and 92 atm), so proposed lander configurations typically include a pressure vessel where the science instruments are kept at Earth-like temperature and pressure (25 deg C and 1 atm). The purpose of this project was to develop and demonstrate a method for sample transfer from an external drill to internal science instruments for a lander on Venus. The initial concepts were string and pneumatically driven systems; and the latter system was selected for its ability to deliver samples at very high speed. The pneumatic system was conceived to be driven by the pressure difference between the Venusian atmosphere and the inside of the lander. The pneumatic transfer of a small capsule was demonstrated, and velocity data was collected from the lab experiment. The sample transfer system was modeled using CAD software and prototyped using 3D printing. General structural and thermal analyses were performed to approximate the proposed system's mass and effects on the temperature and pressure inside of the lander. Additionally, a sampler breadboard for use on Titan was tested and functionality problems were resolved.

sample handling

Introduction to Mars Sampling Handling Workshop Series. Workshop on Life Detection: Issues and Topics

Before martian soil and rock samples can be distributed to the research community, the returned materials will initially be quarantined and examined in a proposed BSL-4 containment facility to assure that no putative martian microorganisms or attendant potential biohazards exist. During the initial quarantine, state-of-the-art life detection and biohazard testing of the returned martian samples will be conducted. Life detection, as defined here in regard to Mars sample return missions, is the detection of living organisms and/or materials that have been derived from living organisms that may be present in the sample.

Rummel, John D.

Sample Handling and Processing on Mars for Future Astrobiology Missions

In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes especially when detecting low concentration organic molecules that may identify extraterrestrial life. Sample processing for analytical instruments is time, resource and manpower consuming in terrestrial laboratories. Every step in this laborious process will have to be automated for in situ life detection. We have developed, and are currently demonstrating, an automated wet chemistry preparation system that can operate autonomously on Earth and is designed to operate under Martian ambient conditions. This will enable a complete wet chemistry laboratory as part of future missions. Our system, namely the Automated Sample Processing System (ASPS) receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species and delivers sample to multiple instruments for analysis (including for non-organic soluble species).

Beegle, Luther

Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

Mora, Maria F.

A Simulated Drilling Mission to Search for Bio-molecular Signatures of Life on Mars Performed in the Atacama Desert (Chile): Demonstrating Drilling, Sample Handling, and Life-Detection Instruments Remotely Operated with Mission-like Protocols

The search for evidence of life on Mars requires accessing materials that are protected from the oxidizing and irradiated conditions at the surface. Mars rovers Curiosity and Perseverance have performed shallow (few cm) drilling to access relevant samples. The upcoming ExoMars mission will acquire samples from up to 2 meters depth. Field experiments in Mars analog sites help prepare for this and other future deep drilling missions. In Sept. 2019 the ARADS (Atacama Rover Astrobiology Drilling Studies project (Glass et al. 2022) conducted a rover-based drilling mission to search for bio-molecular evidence of life in a Mars analog site in Atacama Chile.

Carol R. Stoker

A Simulated Drilling Mission to Search for Biomolecular Signatures of Life on Mars Performed in the Atacama Desert (Chile): Demonstrating Drilling, Sample Handling, and Life-Detection Instruments Remotely Operated with Mission-like Protocols

The search for evidence of life on Mars requires accessing materials that are protected from the oxidizing and irradiated conditions at the surface. Mars rovers Curiosity and Perseverance have performed shallow (few cm) drilling to access relevant samples. The upcoming ExoMars mission will acquire samples from up to 2 meters depth. Field experiments in Mars analog sites help prepare for this and other future deep drilling missions. In Sept. 2019 the ARADS (Atacama Rover Astrobiology Drilling Studies project (Glass et al. 2022) conducted a roverbased drilling mission to search for biomolecular evidence of life in a Mars analog site in Atacama, Chile.

Carol R. Stoker

SPADE: A Rock Crushing and Sample Handling System Developed for Mars Missions

Access to the interior of rocks on Mars is an important goal for understanding Mars petrology and geologic history. The spectral signature of the potentially diverse mineralogy of rocks on Mars is veiled by the ubiquitous dust and may be further hidden by weathered rind. We have developed a rock crusher and sample distribution system under the auspices of NASA s PIDDP program. We call it the SPADE : the Sample Processing and Distribution Experiment. Its purpose is to access the interiors of rocks on Mars and prepare samples for analysis by a suite of in situ instruments.

Hansen, Candice J.

Sample Handling and Instruments for the In-Situ Exploration of Ice-Rich Planets

NASA's key science goals for the exploration of the solar system seek a better understanding of the formation and evolutionary processes that have shaped planetary bodies and emphasize the search for habitable environments. Efforts are also made to detect and quantify resources that could be used for the support of human exploration. These themes call for chemistry and physical property observations that may be best approached by in situ measurements. NASA's planetary missions have progressively evolved from remote reconnaissance to in situ exploration with the ultimate goal to return samples. This chapter focuses on the techniques, available or in development, for advanced geophysical and chemical characterization of icy bodies, especially Mars polar areas, Enceladus, Titan, Europa, and Ceres. These astrobiological targets are the objects of recent or ongoing exploration whose findings are driving the formulation of new missions that involve in situ exploration. After reviewing the overall objectives of icy body exploration (Section 9.1) we describe key techniques used for addressing these objectives from surface platforms via geophysical observations (Section 9.2) and chemical measurements (Section 9.3).

planets

Numerical Modelling of Sublimation Losses During Sample Handling Within the Light WAVE Lunar Water Prospecting Instrument

NASA’s focus of exploring the Moon’s south pole under the Artemis program has placed new emphasis on characterizing the quantity and distribution of water ice and other volatiles present within the Moon’s permanently shadowed regions (PSRs), first measured during the 2009 LCROSS mission. NASA’s VIPER rover is the first of a series of prospecting missions to characterize this water ice resource. NASA’s Johnson Space Center (JSC) has developed the Light Water Analysis and Volatiles Extraction (Light WAVE) instrument shown in Figure 1 for a follow-on prospecting mission, designed to be a rover payload for water ice prospecting at various depths and locations within PSRs. A key source of error for lunar water prospecting instruments, including Light WAVE, is the loss of water in an icy regolith sample to the lunar vacuum via sublimation due to heating above its ice-stable temperature. This abstract and conference presentation discuss a sublimation model for Light WAVE’s sample crucible using COMSOL Multiphysics to assess the sublimation losses that would occur between sample collection from an external drill and sealing the sample within Light WAVE’s boiler.

Lunar Polar Water

MEMS reagent and sample handling procedure: Feasibility of viral antibody detection by passive immune agglutination

An attempt was made to develop a test requiring no preadsorption steps for the assessment of antibodies to rubella and mumps viruses using the passive immune agglutination (PIA) method. Both rubella and mumps antigens and antibodies were prepared. Direct PIA tests, using rubella antigen-coated beads, and indirect PIA tests, using rubella antibody-coated beads, were investigated. Attempts, using either method, were unsuccessful. Serum interference along with nonspecific agglutination of beads by the rubella antigen resulted in no specific response under the test conditions investigated. A new, highly sensitive approach, the enzyme immunoassay (EIA) test system, is recommended to overcome the nonspecificity. This system is a logical outgrowth of some of the solid phase work done on MEMS and represents the next generation tests system that can be directly applied to early disease detection and monitoring.

Bailey, G. D.