Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample thickness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Flow-induced birefringence measurement system using dual-crystal transverse electro-optic modulator for microgravity fluid physics applications

We have developed a new instrument that can measure fast transient birefringence and polymer chain orientation angle in complex fluids. The instrument uses a dual-crystal transverse electro-optic modulator with the second crystal's modulation voltage applied 180 deg out of phase from that of the first crystal. In this manner, the second crystal compensates for the intrinsic static birefringence of the first crystal, and it doubles the modulation depth. By incorporating a transverse electro-optic modulator with two lithium-niobate (LiNbO3) crystals oriented orthogonal to each other with a custom-designed optical system, we have produced a very small robust instrument capable of fast transient retardation measurements. By measuring the sample thickness or optical path length through the sample, we can calculate the transient birefringence. This system can also measure dichroism. We have compared the calibration results and retardation and orientation angle measurements of this instrument with those of a photoelastic modulator (PEM) based system using a quarter wave plate and a high-precision 1/16-wave plate to simulate a birefringent sample. Transient birefringence measurements on the order of 10(exp -9) can be measured using either modulator.

Mackey, Jeffrey R.↗

Resistivity of pristine and intercalated graphite fiber epoxy composites

Laminar composites were fabricated from pristine and bromine intercalated Amoco P-55, P-75, and P-100 graphite fibers and Hysol-Grafil EAG101-1 film epoxy. The thickness and r.f. eddy current resistivity of several samples were measured at grid points and averaged point by point to obtain final values. Although the values obtained this way have high precision (less than 3 percent deviation), the resistivity values appear to be 20 to 90 percent higher than resistivities measured on high aspect ratio samples using multi-point techniques, and by those predicted by theory. The temperature dependence of the resistivity indicates that the fibers are neither damaged nor deintercalated by the composite fabrication process. The resistivity of the composites is a function of sample thickness (i.e., resin content). Composite resistivity is dominated by fiber resistivity, so lowering the resistivity of the fibers, either through increased graphitization or intercalation, results in a lower composite resistivity. A modification of the simple rule of mixtures model appears to predict the conductivity of high aspect ratio samples measured along a fiber direction, but a directional dependence appears which is not predicted by the theory. The resistivity of these materials is clearly more complex than that of homogeneous materials.

Gaier, James R.↗

Resistivity of pristine and intercalated graphite fiber epoxy composites

Laminar composites were fabricated from pristine and bromine intercalated Amoco P-55, P-75, and P-100 graphite fibers and Hysol-Grafil EAG101-1 film epoxy. The thickness and r.f. eddy current resistivity of several samples were measured at grid points and averaged point by point to obtain final values. Although the values obtained this way have high precision (less than 3 percent deviation), the resistivity values appear to be 20 to 90 percent higher than resistivities measured on high aspect ratio samples using multi-point techniques, and by those predicted by theory. The temperature dependence of the resistivity indicates that the fibers are neither damaged nor deintercalated by the composite fabrication process. The resistivity of the composites is a function of sample thickness (i.e., resin content). Composite resistivity is dominated by fiber resistivity, so lowering the resistivity of the fibers, either through increased graphitization or intercalation, results in a lower composite resistivity. A modification of the simple rule of mixtures model appears to predict the conductivity of high aspect ratio samples measured along a fiber direction, but a directional dependence appears which is not predicted by the theory. The resistivity of these materials is clearly more complex than that of homogeneous materials.

Gaier, James R.↗

Microwave Photoelasticity: Exploiting Multiple Resonances to Measure Stress Changes within Yttria-Partially-Stabilized-Zirconia

The NASA Glenn Research Center is developing non-destructive-testing (NDT) methods to enable the measurement of stresses embedded in optically opaque materials using microwave radiation in a free-space quasi-optical system. This methodology tracks microwave resonances observed in reflected scattering parameters extracted from materials under load. In this paper, we report the successful measurement of the stress-optic-coefficient of bulk yttria-partially stabilized zirconia (YTZP) ceramic of C = 1.42 x 10-4 ± 6.65 x 10-6 (1/GPa), across W-Band (80-100 GHz), and determined that this result is independent of sample thickness. The primary goal of this research is to establish a methodology to quantify and assess the life expectancy of ceramic thermal and environmental barrier coating (TBCs/EBCs). Bulk YTZP samples can undergo multiple resonances within a contiguous measurement bandwidth, each corresponding to an integer multiple wave number ∝. This allows for the acquisition and analysis of multiple stress measurement points within a single sample. As an additional benefit, one can approximate the refractive index of YTZP across a wide bandwidth by observing multiple resonances produced by a set of samples with varying thicknesses. Using this approach, the refractive index of bulk YTZP was found to be n = 5.80 ± 0.043 across the 85-115 GHz frequency band.

Seth W. Waldstein↗

Two-Photon Fluorescence Microscopy Developed for Microgravity Fluid Physics

Recent research efforts within the Microgravity Fluid Physics Branch of the NASA Glenn Research Center have necessitated the development of a microscope capable of high-resolution, three-dimensional imaging of intracellular structure and tissue morphology. Standard optical microscopy works well for thin samples, but it does not allow the imaging of thick samples because of severe degradation caused by out-of-focus object structure. Confocal microscopy, which is a laser-based scanning microscopy, provides improved three-dimensional imaging and true optical sectioning by excluding the out-of-focus light. However, in confocal microscopy, out-of-focus object structure is still illuminated by the incoming beam, which can lead to substantial photo-bleaching. In addition, confocal microscopy is plagued by limited penetration depth, signal loss due to the presence of a confocal pinhole, and the possibility of live-cell damage. Two-photon microscopy is a novel form of laser-based scanning microscopy that allows three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon microscopy, it utilizes the nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption because of the nonlinear (i.e., quadratic) electric field dependence, so an ultrafast pulsed laser source must typically be employed. On the other hand, this stringent energy density requirement effectively localizes fluorophore excitation to the focal volume. Consequently, two-photon microscopy provides optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction in photo-damage because of the longer excitation wavelength, a reduction in background fluorescence, and a 4 increase in penetration depth over confocal methods because of the reduction in Rayleigh scattering.

Fischer, David G.↗

Isothermal and cyclic oxidation at 1000 and 1100 deg C of four nickel-base alloys: NASA-TRW VIA, B-1900, 713C, and 738X

The isothermal and cyclic oxidation resistance of four cast Ni-base gamma + gamma prime alloys, NASA-TRW Via, B-1900, 713C, and 738X, was determined in still air at 1000 and 1100 C. The oxidation process was evaluated by specific sample weight change with time, sample thickness change, X-ray diffraction of the scales, and sample metallography. The behavior is discussed in terms of the Cr, Al, and refractory metal contents of the alloys.

Barrett, C. A.↗

Complex Permittivities of Candidate Radome Materials at W-band

This report presents the results of w-band complex permittivity measurements performed in NASA Langley's Electromagnetics Research Branch. The test articles included in the permittivity study were flat panels of materials which are under consideration for use in a radome for the Passive Millimeter Wave Camera (PMMWC) flight experiment. This experiment is scheduled to fly on the Air Force's 'Speckled Trout' aircraft in late 1997. The radome design is very important because the PMMWC can tolerate only a small amount of electromagnetic loss through the radome. A free space measurement system was used to obtain complex reflection and transmission coefficients of the samples. The frequency of interest was 89 GHz, so measurements were performed over a range of 79 to 99 GHz. The transmission and reflection coefficients were used, along with the measured sample thickness, to calculate complex permittivity over the frequency range. The material samples measured in this study can be divided into four categories: skin materials, core materials, coating materials, and layered samples.

Cravey, Robin↗

Increased Flexibility in Polyimide Aerogel Substrates for Conformal, Lightweight Antennas

Polyimide aerogels are desirable for many aerospace applications due to their high porosity, low density, low thermal conductivity, and superior mechanical properties. They have also been demonstrated as lightweight substrates for antennas since they possess very low dielectric constants, approaching one as density decreases. Increasing the flexibility of the aerogel would allow them to be used as conformal antennas for use on aerospace vehicles, leading to significant space and weight savings. In this research, we demonstrate that the flexibility can be increased depending on the polyimide oligomer backbone structures. We have substituted up to 75 mol % of the aromatic diamines typically used in polyimide aerogels with 1, 3-bis (4-aminophenoxy)-2, 2-dimethylpropane (BAPN). Twenty different formulations of polyimide aerogels were synthesized from 3,3',4,4'-biphenyltetracarboxylic dianhydride (BPDA) and a combination of BAPN and 2,2'-dimethylbenxidine (DMBZ) and cross-linked with 1, 3, 5 triaminophenoxybenzene (TAB). The polymer concentration, n-value, and molar concentration of BAPN and DMBZ were varied to determine an ideal formulation that has both a high bend radius and low dielectric constant. With only aromatic diamines in the backbone, the aerogels are flexible only as very thin films, nominally 0.5 mm thick. Samples containing at least 25 mol % BAPN have higher flexibility in substrates as thick as 2-3 mm and dielectric constants ranging from 1.11-1.26.

Cashman, Jessica↗

Temperature-dependent ion mixing and diffusion during sputtering of thin films of CrSi2 on silicon

Measurements of sputtering yields and composition profiles have been carried out using backscattering spectrometry for samples of CrSi2 on Si irradiated wth 200-keV Xe ions. When the CrSi2 layer is thinner than the ion range, the sputtering yield ratio of Si to Cr increases from 3.5 for room-temperature irradiation to 65 at 290 C. For a thick sample, the corresponding increase is from 2.4 to 4.0 only. These changes are explained in terms of a rise in the Si surface concentration ot 290 C. The driving force for this process seems to be the establishment of stoichiometric CrSi2 compound. Transport of Si to the surface is by ion mixing in the thin sample and thermal diffusion through the thick layer.

Shreter, U.↗

Comparing Acoustic Prediction Methods for Additively Manufactured Porous Strutures

While macroscale methods for predicting the acoustic properties of porous structures have been popular in the past, they often require time-consuming manufacturing and testing workflows. Meanwhile, microscale approaches allow the prediction of transport parameters based exclusively on a periodic structure’s unit cell geometry. Here, we compare these methods to predict the characteristic impedance of additively manufactured porous structures. We use the microscale approach to estimate the geometry’s transport parameters, then predict the characteristic properties using the Johnson-Champoux-Allard (JCA) model. We measure the acoustic properties of the printed structures using a normal incidence impedance tube and estimate the transport parameters using an inverse characterization approach. We use the two-thickness method as a macroscale approach to predict the characteristic properties from the measured surface impedances of two sample thicknesses. Finally, we compare these characteristic prediction methods. Our results show that the inverse characterization and two-thickness methods offer the closest match to the measured values at low frequencies.

impedance↗

Compatibility of the Radio Frequency Mass Gauge with Graphite-Epoxy Composite Tanks

The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552/IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 - 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98%. Together, these results suggested that a tank constructed from graphite/epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 less than Q less than 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

Propellant tanks↗

Compatibility of the Radio Frequency Mass Gauge with Composite Tanks

The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98. Together, these results suggested that a tank constructed from graphite-epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 Q 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

Radio frequencies↗

The Explorer XVI Micrometeoroid Satellite: Description and Preliminary Results for the Period December 16, 1962 Through January 13, 1963

Explorer XVI (1962 Beta Chi l) data that have been analyzed for the period between December 16, 1962 (launch date), and January 13, 1963, indicate that the orbit achieved was close to the predicted orbit. Ten punctures of annealed 0.001-inch-thick beryllium-copper have been used to determine a puncture rate of 0.035 per square foot per day in this material. One puncture of a 0.002-inch-thick sample has also occurred in this period. A tentative evaluation of the puncture rate for the 0.001-inch beryllium-copper in terms of the rate for an equivalent thickness of aluminum has been attempted, and the result has been compared with two different puncture rate estimates. The three micrometeoroid impact detecting systems are operating. Counting rates for the high- and low-sensitivity systems were close to anticipated values near the end of one week. Two of the 0.001-inch-steel-covered grid detectors have been punctured, but none of the 0.003- or 0.006-inch-steel-covered grid detectors have indicated punctures. One of the cadmium sulfide cells indicates three punctures of the 0.00025-inch Mylar cover. None of the 0.002- or 0.003-inch-copper-wire cards have indicated a break in the period covered. Telemetry temperatures were initially higher than expected although they remained well within operating limits. Sensor temperatures have remained within the expected bounds.

Micrometeoroid↗

3D Observation of GEMS by Electron Tomography

Amorphous silicates in chondritic porous interplanetary dust particles (CP-IDPs) coming from comets are dominated by glass with embedded metal and sulfides (GEMS). GEMS grains are submicron-sized rounded objects (typically 100-500) nm in diameter) with anaometer-sized (10-50 nm) Fe-Ni metal and sulfide grains embedded in an amorphous silicate matrix. Several formation processes for GEMS grains have been proposed so far, but these models are still being debated [2-5]. Bradley et al. proposed that GEMS grains are interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk and that they are amorphiation products of crystalline silicates in the interstellar medium by sputter-deposition of cosmic ray irradiation, similar to space weathering [2,4]. This consideration is based on the observation of nano-sized crystals (approximately 10 nm) called relict grains in GEMS grains and their shapes are pseudomorphs to the host GEMS grains. On the other hand, Keller and Messenger proposed that most GEMS formed in the protoplanetary disk as condensates from high temperature gas [3,5]. This model is based on the fact that most GEMS grains have solar isotopic compositions and have extremely heterogeneous and non-solar elemental compositions. Keller and Messenger (2011) also reported that amorphous silicates in GEMS grains are surrounded by sulfide grains, which formed as sulfidization of metallic iron grains located on the GEMS surface. The previous studies were performed with 2D observation by using transmission electron microscopy (TEM) or scanning TEM (STEM). In order to understand the structure of GEMS grains described above more clearly, we observed 3D structure of GEMS grains by electron tomography using a TEM/STEM (JEM-2100F, JEOL) at Kyoto University. Electron tomography gives not only 3D structures but also gives higher spatial resolution (approximately a few nm) than that in conventional 2D image, which is restricted by sample thickness ) approx. or greater than 50 nm). Three cluster IDPs (L2036AA5 cluster4, L2009L8 cluster 13 and W726A2) were used for the observations. ID W726A2 was collected without silicon oil, which is ordinary used to collect IDPs, so this sample has no possibility of contaminations caused by silicon oil or solvent to rinse it [6]. The samples were embedded in epoxy risin and sliced into ultrathin sections (50-300 nm) using an ultramicotome. The sections were observed by BF-TEM and HAADF-STEM (high angle annular dark field-scanning TEM) modes. Images were obtained by rotating the sample tilt angle over a range of +/- 65 deg in 1 deg steps. The obtained images were reconstructed to slice images. Mineral phases in the slice images were estimated by comparing with a 2D elemental map obtained by an EDS (energy dispersive X-ray spectroscopy) system equipped in the TEM/STEM. Careful examination of the slice images confirmed that iron grains are embedded in the amorphous silicate matrix of the GEMS grains, but sulfide grains were mainly present on the surface of the amorphous silicate. These results are consistent with the model that GEMS grains formed as condensates [3,5], although more data are needed to conclude the origin of GEMS grains. The present study is the first successful example adapting the electron tomography to the IDPs. This type of analysis will be important for planetary material sciences in the future.

Matsuno, Junya↗

Conductivity effects in high-voltage spacecraft insulating materials

Laboratory measurements were performed to assess the influence of various external parameters on the conductivity properties of several typical and potential spacecraft insulating materials in a simulated space environment. The materials tested include Kapton, Teflon, quartz, and polyvinylidene fluoride. The parameters measured comprise sample thickness, temperature, applied voltage, illumination intensity and wavelength, and electron beam energy and current density. All tests were conducted in a vacuum chamber at a pressure of about one millionth Torr both with conventional optically-transparent gold front-surface electrodes and with the front surfaces of the test samples exposed directly to an electron beam. The data presented illustrate some of the complexities in electrical characteristics exhibited by the materials as a result of interactions with various conditions of their environment.

Adamo, R. C.↗

Near-Field Scanning Optical Microscopy of Soft, Biological, or Rough Objects in Aqueous Environment: Challenges and some Remedies to Circumvent

Near-field scanning optical microscopy is an established technique for sub-wavelength spatial resolution in imaging, spectroscopy, material science, surface chemistry, polarimetry, etc. A significant amount of confidence has been established for thin hard specimens in air. However when soft, biological, rough, in aqueous environment object, or a combination is involved, the progress has been slow. The tip-sample mechanical interaction, heat effects to sample, drag effects to the probe, difficulty in controlling tip-sample separation in case of rough objects, light scattering from sample thickness, etc. create problems. Although these problems are not even fully understood, there have been attempts to study them with the aim of performing reliable operations. In this review we describe these attempts. Starting with general problems encountered, various effects like polarization, thermal, and media are covered. The roles of independent tip-sample distance control tools in the relevant situations are then described. Finally progress in fluid cell aspect has been summarized.

Vikram, C. S.↗

Making Thin Sections from National Treasures: A Little Moon Rock Goes a Long Way

NASA’s Johnson Space Center curates the Apollo sample collection through their facilities in Houston, TX. It is a dual-purpose facility, intended both to store and preserve the precious samples, as well as to make them available for ongoing scientific study and public examination. The facilities consist of multiple vaults and lab spaces, including the Apollo Thin Section Lab. Although it is a part of the Curation facilities, this lab is intended to process specific lunar rock and dust samples into what are called “thin sections”. A thin section is a microscope slide with a very thin, highly polished slice of rock material mounted on it. These are used not only for microscope viewing, but also for a range of other sophisticated scientific instruments to map and measure fine details of the rock’s physical and chemical composition and structure. The process of making a thin section requires great care and patience and is an art in itself; each one is unique, and each sample can behave very differently while going through the same basic procedures. In general, it begins by taking a small chip of rock from a much larger sample. The rock fragment is placed within a small mold and liquid epoxy is poured over it and allowed to harden, producing what is called a “potted butt” (Figure 1). This is to stabilize the rock so that it won’t fragment or crumble during polishing, and to fill any cracks or voids within the rock. Once hardened, the epoxy on the bottom is carefully ground away to expose the rock surface within, which is then polished to a 1-micron finish. A thin new layer of fresh epoxy is then applied to the polished surface and used to mount it to a silica slide. Once the mounting epoxy has hardened, the potted butt is cut off less than one millimeter above the slide using a low-speed circular saw. This thin layer of sample material attached to the slide undergoes further grinding and polishing, typically bringing the sample thickness down to about 35 microns – roughly one third of the thickness of a human hair. The remaining potted butt is saved for future scientific investigations and can be re-polished and used again until all the rock material within it is used up. A single thin section can be reused countless times by numerous different researchers. In addition, thin sections are often exquisitely beautiful (Figure 2) and in some cases, lunar thin sections are used as public display samples, such as at the Smithsonian Air and Space Museum in Washington, DC. The production of thin sections allows an immense variety of research to be conducted on a tiny amount of rock or mineral material, allowing the bulk of the Apollo collection to stay pristine and unaltered, and thus, remain available for next generation of lunar scientists to further our insight into the Moon’s geological diversity, and to bring valuable new insights to our understanding of the origin of the Earth-Moon system.

J J Kent↗

Optical properties of CO2 ice and CO2 snow from ultraviolet to infrared: Application to frost deposits and clouds on Mars

Researchers found that it is possible to grow large clear samples of CO2 ice at Mars-like temperatures of 150-170K if a temperature controlled refrigerator is connected to an isolated two-phase pure CO2 system. They designed a chamber for transmission measurements whose optical path between the 13mm diameter window is adjustable from 1.6mm to 107mm. This will allow measurements of linear absorption down to less than 0.01 cm (exp -1). A preliminary transmission spectrum of a thick sample of CO2 ice in the near infrared was obtained. Once revised optical constants have been determined as a function of wavelength and temperature, they can be applied to spectral reflectance/emissivity models for CO2 snow surfaces, both pure and contaminated with dust and water ice, using previously established approaches. It will be useful, also, to develop an infrared scattering-emission cloud radiance model (especially as viewed from near the limb) in order to develop a strategy for the identification of CO2 cloud layers by the atmospheric infrared radiometer instrument on the Mars Observer.

Hansen, Gary B.↗