Search NASA⌕ Search

SEARCH · Search NASA

Results for “saturation temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

Loop heat pipes (LHPs) have been used for thermal control of several NASA and commercial orbiting spacecraft. The LHP operating temperature is governed by the saturation temperature of its compensation chamber (CC). Most LHPs use the CC temperature for feedback control of its operating temperature. There exists a thermal resistance between the heat source to be cooled by the LHP and the LHP's CC. Even if the CC set point temperature is controlled precisely, the heat source temperature will still vary with its heat output. For most applications, controlling the heat source temperature is of most interest. A logical question to ask is: "Can the heat source temperature be used for feedback control of the LHP operation?" A test program has been implemented to answer the above question. Objective is to investigate the LHP performance using the CC temperature and the heat source temperature for feedback control

Ku, Jentung↗

Real-gas effects 1: Simulation of ideal gas flow by cryogenic nitrogen and other selected gases

The thermodynamic properties of nitrogen gas do not thermodynamically approximate an ideal, diatomic gas at cryogenic temperatures. Choice of a suitable equation of state to model its behavior is discussed and the equation of Beattie and Bridgeman is selected as best meeting the needs for cryogenic wind tunnel use. The real gas behavior of nitrogen gas is compared to an ideal, diatomic gas for the following flow processes: isentropic expansion; normal shocks; boundary layers; and shock wave boundary layer interactions. The only differences in predicted pressure ratio between nitrogen and an ideal gas that may limit the minimum operating temperatures of transonic cryogenic wind tunnels seem to occur at total pressures approaching 9atmospheres and total temperatures 10 K below the corresponding saturation temperature, where the differences approach 1 percent for both isentropic expansions and normal shocks. Several alternative cryogenic test gases - air, helium, and hydrogen - are also analyzed. Differences in air from an ideal, diatomic gas are similar in magnitude to those of nitrogen. Differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. Helium and hydrogen do not approximate the compressible flow of an ideal, diatomic gas.

Hall, R. M.↗

Simulation of ideal-gas flow by nitrogen and other selected gases at cryogenic temperatures

The real gas behavior of nitrogen, the gas normally used in transonic cryogenic tunnels, is reported for the following flow processes: isentropic expansion, normal shocks, boundary layers, and interactions between shock waves and boundary layers. The only difference in predicted pressure ratio between nitrogen and an ideal gas which may limit the minimum operating temperature of transonic cryogenic wind tunnels occur at total pressures approaching 9 atm and total temperatures 10 K below the corresponding saturation temperature. These pressure differences approach 1 percent for both isentropic expansions and normal shocks. Alternative cryogenic test gases were also analyzed. Differences between air and an ideal diatomic gas are similar in magnitude to those for nitrogen and should present no difficulty. However, differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. It is concluded that helium and cryogenic hydrogen would not approximate the compressible flow of an ideal diatomic gas.

Hall, R. M.↗

Evaluating the Calibration of Aqua MODIS Bands 33, 35, and 36 During Blackbody Warm-Up Cool-Down Events

Aqua MODIS is the second MODIS instrument of NASA's Earth Observation System and has operated for over sixteen years since its launch in 2002. MODIS has sixteen thermal emissive bands (TEBs) located on two separate cold focal plane assemblies (CFPA). The TEBs are calibrated every scan using observations of an onboard blackbody (BB) and a space view port. Low saturation temperatures (Tsat) of Aqua MODIS bands 33, 35, and 36 cause these bands to saturate when the BB temperature is higher than their Tsat values during a BB warm-up cool-down (WUCD) cycle, therefore impacting the ability to perform nominal calibration. In addition, starting from around 2006, the CFPA temperature showed gradual variation from its nominally-controlled operating temperature due to a loss of its radiative cooler margin and the magnitude of its fluctuation reaching a maximum in 2013. The MODIS Characterization Support Team currently uses a correction that is dependent on the CFPA temperature to provide a gain estimate for the saturated scans during the BB WUCD. This gain estimation has been implemented in the Aqua MODIS Collection 6 (C6) and C6.1 L1B products. This paper evaluates the quality of the calibrated radiance of Aqua MODIS bands 33, 35, and 36 using simultaneous nadir observations from the Atmospheric Infrared Sounder (AIRS), which is also onboard the Aqua satellite. Our analysis results show that the differences between AIRS and Aqua MODIS can be controlled well within the fluctuation range compared to the periods when the BB signals for these bands are not saturated.

Li, Yonghong↗

Carbon Dioxide Clouds at High Altitude in the Tropics and in an Early Dense Martian Atmosphere

We use a time dependent, microphysical cloud model to study the formation of carbon dioxide clouds in the Martian atmosphere. Laboratory studies by Glandor et al. show that high critical supersaturations are required for cloud particle nucleation and that surface kinetic growth is not limited. These conditions, which are similar to those for cirrus clouds on Earth, lead to the formation of carbon dioxide ice particles with radii greater than 500 micrometers and concentrations of less than 0.1 cm(exp -3) for typical atmospheric conditions. Within the current Martian atmosphere, CO2 cloud formation is possible at the poles during winter and at high altitudes in the tropics during periods of increased atmospheric dust loading. In both cases, temperature perturbations of several degrees below the CO2 saturation temperature are required to nucleate new cloud particles suggesting that dynamical processes are the most common initiators of carbon dioxide clouds rather than diabatic cooling. The microphysical cloud model, coupled to a two-stream radiative transfer model, is used to reexamine the impact of CO2 clouds on the surface temperature within a dense CO2 atmosphere. The formation of carbon dioxide clouds leads to a warmer surface than what would be expected for clear sky conditions. The amount of warming is sensitive to the presence of dust and water vapor in the atmosphere, both of which act to dampen cloud effects. The radiative warming associated with cloud formation, as well as latent heating, work to dissipate the clouds when present. Thus, clouds never last for periods much longer than several days, limiting their overall effectiveness for warming the surface. The time average cloud optical depth is approximately unity leading to a 5-10 K warming, depending on the surface pressure. However, the surface temperature does not rise about the freezing point of liquid water even for pressures as high as 5 bars, at a solar luminosity of 75% the current value.

Colaprete, Anthony↗

Implementation of Sub-Cooling of Cryogenic Propellants by Injection of Non-condensing Gas to the Generalized Fluid Systems Simulation Program (GFSSP)

Cryogenic propellants are readily heated when used. This poses a problem for rocket engine efficiency and effective boot-strapping of the engine, as seen in the "hot" LOX (Liquid Oxygen) problem on the S-1 stage of the Saturn vehicle. In order to remedy this issue, cryogenic fluids were found to be sub-cooled by injection of a warm non-condensing gas. Experimental results show that the mechanism behind the sub-cooling is evaporative cooling. It has been shown that a sub-cooled temperature difference of approximately 13 deg F below saturation temperature [1]. The phenomenon of sub-cooling of cryogenic propellants by a non-condensing gas is not readily available with the General Fluid System Simulation Program (GFSSP) [2]. GFSSP is a thermal-fluid program used to analyze a wide variety of systems that are directly impacted by thermodynamics and fluid mechanics. In order to model this phenomenon, additional capabilities had to be added to GFSSP in the form of a FORTRAN coded sub-routine to calculate the temperature of the sub-cooled fluid. Once this was accomplished, the sub-routine was implemented to a GFSSP model that was created to replicate an experiment that was conducted to validate the GFSSP results.

Huggett, Daniel J.↗

Numerical Simulation of Liquid Nitrogen Chilldown of a Vertical Tube

This paper presents the results of a one-dimensional numerical simulation of the transient chilldown of a vertical stainless steel tube with liquid nitrogen. The direction of flow is downward (with gravity) through the tube. Heat transfer correlations for film, transition, and nucleate boiling, as well as critical heat flux, rewetting temperature, and the temperature at the onset of nucleate boiling were used to model the convection to the tube wall. Chilldown curves from the simulations were compared with data from 55 recent liquid nitrogen chilldown experiments. With these new correlations the simulation is able to predict the time to rewetting temperature and time to onset of nucleate boiling to within 25% for mass fluxes ranging from 61.2 to 1150 kg/(sq m s), inlet pressures from 175 to 817 kPa, and subcooled inlet temperatures from 0 to 14 K below the saturation temperature.

GFSSP↗

An analysis of data related to the minimum temperatures for valid testing in cryogenic wind tunnels using nitrogen as the test gas

The minimum operating temperature which avoids adverse low temperature effects, such as condensation, has been determined at a free stream Mach number of 0.85 for flow over a 0.137 meter airfoil mounted at zero incidence in the Langley 1/3 meter transonic cryogenic tunnel. The onset of low temperature effects is established by comparing the pressure coefficient measured at a given orifice for a particular temperature with those measured at temperatures sufficiently above where low temperature effects might be expected to occur. The pressure distributions over the airfoil are presented in tabular form. In addition, the comparisons of the pressure coefficient as a function of total temperature are presented graphically for chord locations of 0, 25, 50, and 75 percent. Over the 1.2 to 4.5 atmosphere total pressure range investigated, low temperature effects are not detected until total temperatures are 2 K, or more, below free stream saturation temperatures.

Hall, R. M.↗

Onset of condensation effects in cryogenic wind tunnels

The onset of condensation effects in cryogenic wind tunnels which limits their minimum operating temperatures is examined. If this onset of effects occurs below saturation temperature, then the tunnels may be operated at the lower temperatures and additional benefits to cryogenic tunnel operation resulting in increased Reynolds number capability and reduced operating costs. Both homogeneous and heterogeneous nucleation processes are discussed as they pertain to continuous flow cryogenic wind tunnels. Examples from condensation experiments in the 0.3 m Transonic Cryogenic Tunnel are also reviewed.

Hall, R. M.↗

Numerical studies of the effects of jet-induced mixing on liquid-vapor interface condensation

Numerical solutions of jet-induced mixing in a partially full cryogenic tank are presented. An axisymmetric laminar jet is discharged from the central part of the tank bottom toward the liquid-vapor interface. Liquid is withdrawn at the same volume flow rate from the outer part of the tank. The jet is at a temperature lower than the interface, which is maintained at a certain saturation temperature. The interface is assumed to be flat and shear-free and the condensation-induced velocity is assumed to be negligibly small compared with radial interface velocity. Finite-difference method is used to solve the nondimensional form of steady state continuity, momentum, and energy equations. Calculations are conducted for jet Reynolds numbers ranging from 150 to 600 and Prandtl numbers ranging from 0.85 to 2.65. The effects of above stated parameters on the condensation Nusselt and Stanton numbers which characterize the steady-state interface condensation process are investigated. Detailed analysis to gain a better understanding of the fundamentals of fluid mixing and interface condensation is performed.

Lin, Chin-Shun↗

Numerical studies of the effects of jet-induced mixing on liquid-vapor interface condensation

Numerical solutions of jet-induced mixing in a partially full cryogenic tank are presented. An axisymmetric laminar jet is discharged from the central part of the tank bottom toward the liquid-vapor interface. Liquid is withdrawn at the same volume flow rate from the outer part of the tank. The jet is at a temperature lower than the interface, which is maintained at a certain saturation temperature. The interface is assumed to be flat and shear-free and the condensation-induced velocity is assumed to be negligibly small compared with radial interface velocity. Finite-difference method is used to solve the nondimensional form of steady state continuity, momentum, and energy equations. Calculations are conducted for jet Reynolds numbers ranging from 150 to 600 and Prandtl numbers ranging from 0.85 to 2.65. The effects of above stated parameters on the condensation Nusselt and Stanton numbers which characterize the steady-state interface condensation process are investigated. Detailed analysis to gain a better understanding of the fundamentals of fluid mixing and interface condensation is performed.

Lin, Chin-Shun↗

Vapor condensation at the free surface of an axisymmetric liquid mixed by a laminar jet

This paper presents numerical solutions of jet-induced mixing in a partially full cryogenic tank. An axisymmetric laminar jet is discharged from the central part of the tank bottom toward the liquid-vapor interface. Liquid is withdrawn at the same volume flow rate from the outer part of the tank. The jet is at a temperature lower than the interface, which is maintained at a certain saturation temperature. The interface is assumed to be flat and shear free and the condensation-induced velocity is assumed to be negligibly small compared with radial interface velocity. Finite-difference method is used to slove the nondimensional form of steady-state continuity, momentum, and energy equations. Calculations are conducted for jet Reynolds numbers ranging from 150 to 600 and Prandtl numbers ranging from 0.85 to 2.65. The effects of previously stated parameters on the condensation Nusselt and Stanton numbers that characterize the steady-state interface condensation process are investigated. Detailed analysis is performed to gain a better understanding of the fundamentals of fluid mixing and interface condensation.

Lin, Chin-Shun↗

Methods of Controlling the Loop Heat Pipe Operating Temperature

The operating temperature of a loop heat pipe (LHP) is governed by the saturation temperature of its compensation chamber (CC); the latter is in turn determined by the balance among the heat leak from the evaporator to the CC, the amount of subcooling carried by the liquid returning to the CC, and the amount of heat exchanged between the CC and ambient. The LHP operating temperature can be controlled at a desired set point by actively controlling the CC temperature. The most common method is to cold bias the CC and use electric heater power to maintain the CC set point temperature. The required electric heater power can be large when the condenser sink is very cold. Several methods have been developed to reduce the control heater power, including coupling block, heat exchanger and separate subcooler, variable conductance heat pipe, by-pass valve with pressure regulator, secondary evaporator, and thermoelectric converter. The paper discusses the operating principles, advantages and disadvantages of each method.

Ku, Jentung↗

Analysis of Water Recovery Rate from the Heat Melt Compactor

Human space missions generate trash with a substantial amount of plastic (20% or greater by mass). The trash also contains water trapped in food residue and paper products and other trash items. The Heat Melt Compactor (HMC) under development by NASA Ames Research Center (ARC) compresses the waste, dries it to recover water and melts the plastic to encapsulate the compressed trash. The resulting waste disk or puck represents an approximately ten-fold reduction in the volume of the initial trash loaded into the HMC. In the current design concept being pursued, the trash is compressed by a piston after it is loaded into the trash chamber. The piston face, the side walls of the waste processing chamber and the end surface in contact with the waste can be heated to evaporate the water and to melt the plastic. Water is recovered by the HMC in two phases. The first is a pre-process compaction without heat or with the heaters initially turned on but before the waste heats up. Tests have shown that during this step some liquid water may be expelled from the chamber. This water is believed to be free water (i.e., not bound with or absorbed in other waste constituents) that is present in the trash. This phase is herein termed Phase A of the water recovery process. During HMC operations, it is desired that liquid water recovery in Phase A be eliminated or minimized so that water-vapor processing equipment (e.g., condensers) downstream of the HMC are not fouled by liquid water and its constituents (i.e., suspended or dissolved matter) exiting the HMC. The primary water recovery process takes place next where the trash is further compacted while the heated surfaces reach their set temperatures for this step. This step will be referred to herein as Phase B of the water recovery process. During this step the waste chamber may be exposed to different selected pressures such as ambient, low pressure (e.g., 0.2 atm), or vacuum. The objective for this step is to remove both bound and any remaining free water in the trash by evaporation. The temperature settings of the heated surfaces are usually kept above the saturation temperature of water but below the melting temperature of the plastic in the waste during this step to avoid any encapsulation of wet trash which would reduce the amount of recovered water by blocking the vapor escape. In this paper, we analyze the water recovery rate during Phase B where the trash is heated and water leaves the waste chamber as vapor, for operation of the HMC in reduced gravity. We pursue a quasi-one-dimensional model with and without sidewall heating to determine the water recovery rate and the trash drying time. The influences of the trash thermal properties, the amount of water loading, and the distribution of the water in the trash on the water recovery rates are determined.

Heat Melt Compactor↗

The Life and Times of Supervolcanoes: Inferences from Long Valley Caldera

Cataclysmic eruptions of silicic magma from "supervolcanoes" are among the most awe-inspiring natural phenomena found in the geologic record, in terms of size, power, and potential hazard. Based on the repose intervals between eruptions of this magnitude, the magmas responsible for them could accumulate gradually in the shallow crust over time scales that may be in excess of a million years (Smith, 1979; Spera and Crisp, 1981; Shaw, 1985). Pre-eruption magma residence time scales can also be inferred from the age difference between eruption (i.e., using 40Ar/39Ar dating to determine the time when hot erupted material cools to below its Ar closure temperature, 200 to 600 degC) and early pre-eruption crystallization (i.e., zircon saturation temperatures; Reid et al., 1997). I will discuss observations from Long Valley a Quaternary volcanic center in California. Long Valley is a voluminous, dominantly silicic caldera system. Based on extensive dating of accessory minerals (e.g., U-Th-Pb dating of zircon and allanite) along with geochemical and isotopic data we find that silicic magmas begin to crystallize 10's to 100's of thousands of years prior to their eruption and that rhyolites record episodes of punctuated and independent evolution rather than the periodic tapping of a long-lived magma. The more punctuated versus more gradual magma accumulation rates required by the absolute and model ages, respectively, imply important differences in the mass and heat fluxes associated with the generation, differentiation, and storage of voluminous rhyolites and emphasize the need to reconcile the magmatic age differences.

Simon, Justin↗

BOILING HEAT TRANSFER TO LIQUID HYDROGEN AND NITROGEN IN FORCED FLOW

Boiling heat transfer to liquid hydrogen and nitrogen was investigated experimentally. Results are presented from a study of bulk boiling inside a cylindrical tube under vertically upward forced-flow conditions. A 0.555-inch-inside-diameter and 16 (1/8)-inch-long electrically heated stainless-steel tube was used. The range of variables studied for hydrogen were mass velocity of 2850 to 17,000 pounds per hour per square foot, local heat flux of 3600 to 40,000 Btu per hour per square foot, inlet pressure of 30 to 74 pounds per square inch absolute, and inlet subcooling of 0° to 9° R. Nitrogen test conditions were mass velocity of 15,000 to 56,000 pounds per hour per square foot, local heat flux of 2300 to 40,000 Btu per hour per square foot, inlet pressure of 47 to 56 pounds per square inch absolute, and inlet sub cooling of 1° to 6° R. The axial distribution of the tube-wall temperatures is presented. A transition in the type of boiling heat transfer was obtained. The critical heat flux corresponding to this transition was determined over a range of flow and heating rates and local qualities. At specific combinations of flow and transition location, a range of critical-heat-flux values was obtained and maximum values were determined. The maximum critical heat flux increased with increasing fluid-flow rate and decreased with increasing length of tube before transition. Similar variations of the maximum critical heat flux have been reported for water. The tube-inner-wall temperatures upstream of transition were essentially uniform and were only slightly greater than the fluid saturation temperature. The Wall-temperature profiles downstream of transition generally resembled those obtained in film-boiling studies and appeared to be strongly dependent upon local quality at the point of transition. Maximum wall temperatures of 9000 and 18000 R were obtained with hydrogen and nitrogen, respectively. Fluctuations of pressure, flow rate, and temperature occurred during some of the boiling tests. Under some conditions, maximum critical-heat-flux values were attained during steady-state operation with fluctuations. In other cases the fluctuations became uncontrolled, and critical-flux values less than the maximum values were obtained upon restabilization of the test conditions. No measurable pressure drop across the test section was obtained at any condition.

LIQUID HYDROGEN↗

Summary of LO2/Ethanol OMS/RCS Technology and Advanced Development 99-2744

NASA is pursuing non-toxic propellant technologies applicable to RLV and Space Shuttle orbital maneuvering system (OMS) and reaction control system (RCS). The primary objectives of making advancements in an OMS/RCS system are improved safety, reliability, and reduced operations and maintenance cost, while meeting basic operational and performance requirements. An OMS/RCS has a high degree of direct interaction with the vehicle and crew and requires subsystem and components that are compatible with integration into the vehicle with regard to external mold-line, power, and thermal control. In July 1997, a Phase I effort for the technology and advanced development of an upgrade of the space shuttle was conducted to define the system architecture, propellant tank, feed system, RCS thrusters, and OMS engine. Phase I of the project ran from July 1997 to October 1998. Phase II is currently being planned for the development and test of full-scale prototype of the system in 1999 and 2000. The choice of pressure-fed liquid oxygen (LO2) and ethanol is the result of numerous trade studies conducted from 1980 to 1996. Liquid oxygen and ethanol are clean burning, high-density propellants that provide a high degree of commonality with other spacecraft subsystems including life support, power, and thermal control, and with future human exploration and development of space missions. The key to this pressure-fed system is the use of subcooled liquid oxygen at 350 psia. In this approach, there is 80 degrees R of subcooling, which means that boil-off will not occur until the temperature has risen 80 R. The sub-cooling results naturally from loading propellants at 163 R, which is the saturation temperature at 14.7 psia, and then pressurizing to 350 psia on the launch pad. Thermal insulation and conditioning techniques are then used to limit the LO2 temperature to 185 R maximum, and maintain the sub-cooling. The other key is the wide temperature range of ethanol, -173 F to +300 F, which can provide heat to gasify liquid oxygen or provide a good coolant.

Curtis, Leslie A.↗

Numerical investigation of the thermal stratification in cryogenic tanks subjected to wall heat flux

The flow pattern and thermal stratification of a cryogenic cylindrical tank are numerically studied. The tank sidewall is subjected to either a uniform heat-flux or two discrete levels of uniform heat-flux at the upper and lower halves of the tank wall. The tank bottom is kept at a constant temperature controlled by the heat exchanger of a thermodynamic vent system. The tank pressure is also assumed constant resulting in a constant saturation temperature at the interface which is higher than the tank bottom temperature. The effects of vapor motion and vapor superheat on the mass and heat transfer processes at the interface are assumed negligible such that the calculations of liquid region can be decoupled from the vapor region. Dimensionless steady-state conservation equations are solved by a finite-difference method. The effects of modified Rayleigh number, Prandtl number, tank aspect ratio, wall heat-flux parameter, and wall heat-flux distribution on the liquid velocity and temperature fields are investigated. Also, their effects on the rate of heat transfer through the interface and the tank bottom are examined.

Lin, Chin-Shun↗