Search NASA⌕ Search

SEARCH · Search NASA

Results for “scanner”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

TCF Base Technology-Specific: Real-time soil core scanner for carbon and other elements (Final Report)

The aim of this project was to commercialize an instrument that will accurately and precisely measure carbon in soil, providing a breakthrough in scalable soil core analysis and enabling a robust measurement of the total amount of carbon per acre. The instrument will measure the whole soil core, rather than just a few sub-samples, and provide data for carbon depth profiling, as well as other key soil elements such as Al, Si, O, Fe. This instrument will provide faster turnaround times and more precise results than current methods (such as loss on ignition), facilitating the analysis of many soil cores per acre. Ultimately, this will enable farmers to improve their carbon-in-soil content, thus contributing to an improved soil health and product yield. To achieve this goal, we divided the project into three main tasks: 1) commercialization research, 2) technical development, and 3) instrument development, demonstration, and benchmarking.

47 OTHER INSTRUMENTATION↗

Port scanner and Testing Suite

This project addresses the challenge of identifying and managing open network ports across physical and virtual hosts. The current form of verifying ports in use required manually searching individual ports - a process that was both time- consuming and a potential bottleneck for deployment timelines. To resolve this, an automated port scanning tool was developed in Python. The tool supports simultaneous multiple port scans. To ensure functionality and long-term maintainability, a comprehensive testing suite was implemented using Python’s unittest framework. Edge cases, including valid port numbers, reversed ranges, and closed ports, were explicitly tested to ensure robust handling of real-world scenarios. The resulting tool reduces the time required to verify port security across a network, supporting both targeted and host checks and broader Classless Inter-Domain Routing (CIDR) -based network scans. This work demonstrates the value of automation and test-driven development in strengthening network security practices, and provides a foundation for future enhancements.

Rivera, Linda [Fermilab]↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Successful Cleanroom Installation of PIP-II SSR2 Coupler Using Robotic Arm

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instruments to directly collect information on the beam s transverse distribution. The manipulation of the conditions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

Narug, C.↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Characterization of the image plate multi-scan response to mono-energetic x-rays

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

Instruments & Instrumentation↗

Computed Tomography Scanning and Geophysical Measurements of UW Enterprises LP 1-250512-129 Well in Southwestern Indiana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Illinois Basin core of the Upper Devonian-Early Mississippian New Albany Shale Formation from Posey County, Indiana. The primary impetus of this work is a collaboration between Indiana Geological and Water Survey at Indiana University Bloomington, NETL, and Woolsey Operating Company LLC to characterize and make publicly available core information from the New Albany Shale of the Illinois Basin. Core characterization of this unconventional oil/gas well will aid in understanding the lithology changes and the fracture complexity of the New Albany Shale. There is a potential for this formation to be developed in the future for critical mineral and rare earth element (CM/REE) extraction. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/uw-enterprises. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on this core. None of the equipment used was suitable for direct visualization of the pore space in the fine-grained structures studied; however, fractures, discontinuities, and millimeter-scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Targeted higher resolution CT scanning of select sections was performed with NETL’s industrial and micro-CT scanner. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT↗

OPEN-Augmented Reality GUI for Bioenergy Crop Phenotyping and Precision Agriculture (Donald Danforth Plant Science Center Final Scientific Technical Report)

The project led by the Donald Danforth Plant Science Center, in collaboration with Arizona State University, George Washington University, and Saint Louis University, has made significant strides in advancing the phenotypic analysis of bioenergy crops through the development of an innovative AI processing pipeline. This initiative was primarily funded by ARPA-E, with additional cost-sharing provided by the participating institutions. The project successfully utilized a variety of sensors—3D scanners, thermal, RGB, and hyperspectral—to refine algorithms for data-driven trait signature identification and improve the classification and visualization of plant traits. The developed AI processing pipeline is capable of handling the complex, multidimensional data characteristic of dynamic agricultural environments. 1) Contributions to understanding: The research has advanced the field of plant phenomics by showcasing the synergistic use of various sensor data to enhance the precision of trait analysis in bioenergy crops. Through the integration of 3D scanners, thermal, RGB, and hyperspectral sensors, the project has developed robust data-driven trait signature algorithms and visualization techniques. These innovations have facilitated detailed monitoring and management of plant traits, providing vital insights into plant growth dynamics and stress responses. Further, the project has broadened our understanding of how machine learning can be effectively applied in multi-sensor environments to refine trait analysis. By leveraging diverse datasets, the research has not only improved the accuracy of phenotypic assessments but also established a versatile methodological framework that can be extended beyond agriculture to other fields requiring detailed phenotypic analysis. 2) Technical effectiveness and economic feasibility: The AI processing pipeline developed in this project demonstrated significant technical effectiveness, achieving high throughput analysis of extensive phenotypic data and meeting targeted accuracies. This system exemplified the capability of advanced machine learning technologies to efficiently manage and analyze large, complex datasets. Economically, the implementation of the project-developed pipelines may offer substantial cost savings across multiple sectors. It enhances data analysis processes and significantly reduces the need for manual data interpretation, thereby decreasing both the time and resources required. 3) Public benefit: The project has significantly broadened the scope of agricultural methodologies to enhance phenotypic analysis, with potential applications in various sectors beyond agriculture. Additionally, the initiative fostered an enriching educational and collaborative environment, significantly enhancing the technical skills of participants. It also made substantial contributions to the scientific community by providing open-access data sets and tools, encouraging ongoing research and development across various disciplines. Overall, the project not only met its scientific goals but also showcased the extensive utility of integrating advanced machine learning and sensor data analysis technologies. These advancements have proven instrumental in driving forward both theoretical research and practical applications, setting a strong foundation for future explorations and innovations in data-driven science.

60 APPLIED LIFE SCIENCES↗

The Zwicky Transient Facility Bright Transient Survey. III. BTSbot: Automated Identification and Follow-up of Bright Transients with Deep Learning

Abstract The Bright Transient Survey (BTS) aims to obtain a classification spectrum for all bright ( m peak ≤ 18.5 mag) extragalactic transients found in the Zwicky Transient Facility (ZTF) public survey. BTS critically relies on visual inspection (“scanning”) to select targets for spectroscopic follow-up, which, while effective, has required a significant time investment over the past ∼5 yr of ZTF operations. We present BTSbot , a multimodal convolutional neural network, which provides a bright transient score to individual ZTF detections using their image data and 25 extracted features. BTSbot is able to eliminate the need for daily human scanning by automatically identifying and requesting spectroscopic follow-up observations of new bright transient candidates. BTSbot recovers all bright transients in our test split and performs on par with scanners in terms of identification speed (on average, ∼1 hr quicker than scanners). We also find that BTSbot is not significantly impacted by any data shift by comparing performance across a concealed test split and a sample of very recent BTS candidates. BTSbot has been integrated into Fritz and Kowalski , ZTF’s first-party marshal and alert broker, and now sends automatic spectroscopic follow-up requests for the new transients it identifies. Between 2023 December and 2024 May, BTSbot selected 609 sources in real time, 96% of which were real extragalactic transients. With BTSbot and other automation tools, the BTS workflow has produced the first fully automatic end-to-end discovery and classification of a transient, representing a significant reduction in the human time needed to scan.

Rehemtulla, Nabeel (ORCID:0000000256832389)↗

Gamma Ray Detection In Liquid Argon Time Projection Chambers

Gamma rays are photons in excess of 100 keV of energy and can be produced by a variety of mechanisms like radioactive decay and inelastic neutrino-argon interactions. A reconstruc- tion of Compton scattering gamma rays was developed for use in liquid argon time projection chambers. This reconstruction was tested with detectors developed to demonstrate the ca- pabilities of Deep Underground Neutrino Experiment (DUNE) Near Detector Liquid Argon target (ND LAr). In October 2024, a radioactive fluorine-18 source was placed next to the Full Scale Demonstrator. The data obtained was used to test this reconstruction algorithm. It was able to determine the direction of the photons with an error of less than 10 percent. In addition to this work, there has been significant work on designing a liquid argon based Positron Emission Tomography (PET) scanner. PET scanners detect gamma rays emitted by a tracer chemical to help screen for diseases like cancer. In addition to the applications to medical imaging, this thesis briefly explores the applications of this reconstruction to de-excitation photons produced in interactions between neutrinos and argon nuclei. These applications could improve studies focusing on neutrinos originating from accelerators and supernovae.

Murphy, Thomas [Syracuse U.]↗

Fission Product Quantification and Burnup Analysis via Gamma Spectrometry of the AGR-5/6/7 TRISO Fuel Experiment

Five capsules containing varying configurations of TRISO fuel compacts were irradiated in the most recent Advanced Gas Reactor (AGR) TRISO test campaign, AGR-5/6/7. As part of the post-irradiation examination (PIE) of this work all the fuel compacts and capsule graphite holders were measured with the Precision Gamma Scanner (PGS) to determine isotopic activities and locations using gamma spectrometry. Measuring the compacts allowed for the comparison of physics model depletion calculations with the measured compact activity to validate models. These measurements also are used to find compacts of interest with low fission product retention that may be tested in subsequent PIE. Measurements of the holders can confirm fission product distribution and migration. Of the isotopes measured, Cs-137 and Cs-134 were used to estimate location of failed particles as well as determine a measured burnup estimation. Results from Capsule 1 compacts and the holder indicate many fuel particle failures occurred. There are high amounts of cesium in the holder near Stack 9 of Capsule 1 that corresponds to low fractions?measured-to-calculated (M/C) ratio?of cesium remaining in those compacts. All other capsules had cesium retention ratios near 1. The isotope 110mAg had less consistent results. Capsule 2 compacts exhibited a M/C of 0.20, much lower than anticipated for the temperatures these compacts underwent. Capsule 3 experienced much higher temperatures, >1300C and had an average M/C of 0.75. These are the opposite results than what was predicted by past AGR experiments for the relationship between temperature and isotope retention. Capsule 4 and 5 showed good fission product retention and agreement with the physics model predictions. The burnup results from the PGS measurements showed strong agreement between the physics models and the measured values. Using a ratio of Cs-134/Cs-137 to calculate the burnup match closely with the physics models. Additionally, the Cs-137 burnup results were less accurate but extremely close to the model results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Positron emission tomography harmonization in the Alzheimer's Disease Neuroimaging Initiative: A scalable and rigorous approach to multisite amyloid and tau quantification

Abstract INTRODUCTION A key goal of the Alzheimer's Disease NeuroImaging Initiative (ADNI) positron emission tomography (PET) Core is to harmonize quantification of β‐amyloid (Aβ) and tau PET image data across multiple scanners and tracers. METHODS We developed an analysis pipeline (Berkeley PET Imaging Pipeline, B‐PIP) for ADNI Aβ and tau PET images and applied it to PET data from other multisite studies. Steps include image pre‐processing, refacing, magnetic resonance imaging (MRI)/PET co‐registration, visual quality control (QC), quantification of tracer uptake, and standardization of Aβ and tau standardized uptake value ratios (SUVrs) across tracers. RESULTS Measurements from 10,105 cross‐sectional and longitudinal Aβ and tau PET scans acquired in several studies between 2010 and 2024 can be processed, harmonized, and directly merged across tracers and cohorts. DISCUSSION The B‐PIP developed in ADNI is a scalable image harmonization approach used in several observational studies and clinical trials that facilitates rigorous Aβ and tau PET quantification and data sharing. Highlights Quantitative results from ADNI Aβ and tau PET data are generated using a rigorous, scalable image processing pipeline This pipeline has been applied to PET data from several other large, multisite studies and trials Quantitative outcomes are harmonizable across studies and are shared with the scientific community

Neurosciences & Neurology↗

Calibration of multisite raters for prospective visual reads of amyloid PET scans

Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen'sκ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.

Neurosciences & Neurology↗

Toward Ultra‐High‐Quality‐Factor Wireless Masing Magnetic Resonance Sensing

It has recently been shown that a bolus of hyperpolarized nuclear spins can yield stimulated emission signals similar in nature to maser signals, potentially enabling new ways of sensing hyperpolarized contrast media, including most notably [1- 13 C]pyruvate that is under evaluation in over 50 clinical trials for metabolic imaging of cancer. The stimulated NMR signal emissions lasting for minutes do not require radio-frequency excitation, offering unprecedented advantages compared to conventional MR sensing. However, creating nuclear spin maser emission is challenging in practice due to stringent fundamental requirements, making practical in vivo applications hardly possible using conventional passive MR detectors. Here, in this study, we demonstrate the utility of a wireless NMR maser detector, the quality factor of which was enhanced 22-fold (to 1,670) via parametric pumping. This active-feedback technique breaks the intrinsic fundamental limit of NMR detector circuit quality factor. We show the use of parametric pumping to reduce the threshold requirement for inducing nuclear spin masing at 300 MHz resonance frequency in a preclinical MRI scanner. Indeed, stimulated emission from hyperpolarized protons was obtained under highly unfavorable conditions of low magnetic field homogeneity (T 2 * of 3 ms). Greater gains of the quality factor of the MR detector (up to 1 million) were also demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid RASER MRI

Conventional Magnetic Resonance Imaging (MRI) relies on high-power Radio-Frequency (RF) pulses to excite nuclear spins and in turn generate NMR signals. These pulses require large high-power RF-amplifiers and cause heat deposition in the tissue, which must be minimized for safety, presenting a growing problem when moving toward ever-higher field MRI. An alternative to RF-pulse excitation is self-excitation of nuclear spins using Radiofrequency Amplification by Stimulated Emission of Radiation (RASER), where the nuclear spins undergo spontaneous transition, without RF excitation, from an over-populated state to a ground state. Here, the feasibility of recording rapid proton RASER MRI images of pyrazine at low concentration (120 mM) with large matrix (128x128 pixels) in as little as 78 ms is demonstrated at 500 MHz (11.7 T). We also recorded a time-series of images using a single bolus hyperpolarized pyrazine highlighting the feasibility of dynamic tracking. Here, the demonstrated approach allows recording MRI scans without transmit-receive electronics of the MRI scanner, which is highly desirable for portable MRI as well as the emerging field of hyperpolarized MRI using, e.g., HP protons, 129 Xe gas or HP 13 C labeled biomolecules as molecular tracers and imaging agents.

MRI↗

Seed classification with random forest models

Premise: To improve forest conservation monitoring, we developed a protocol to automatically count and identify the seeds of plant species with minimal resource requirements, making the process more efficient and less dependent on human operators. Methods and Results: Seeds from six North American conifer tree species were separated from leaf litter and imaged on a flatbed scanner. In the most successful species-classification approach, an ImageJ macro automatically extracted measurements for random forest classification in the software R. The method allows for good classification accuracy, and the same process can be used to train the model on other species. Conclusions: This protocol is an adaptable tool for efficient and consistent identification of seed species or potentially other objects. Automated seed classification is efficient and inexpensive, making it a practical solution that enhances the feasibility of large-scale monitoring projects in conservation biology.

59 BASIC BIOLOGICAL SCIENCES↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗