Search NASA⌕ Search

SEARCH · Search NASA

Results for “scattering experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tunable Nanostructures from Inverse Surfactants

Hierarchical materials in the natural world are often made through the self-assembly of amphiphilic molecules. Achieving similar structural complexity in synthetic materials requires understanding how various molecular parameters affect assembly behavior. In recent years, inverse surfactants─molecules with hydrophobic head groups and hydrophilic macromolecular tails─have been shown to self-assemble into supramolecular assemblies in aqueous solutions that show promise for a number of applications, including drug delivery. Here, we build an understanding of the morphological phase diagram of inverse surfactants using insights from scattering experiments, computer simulations, and statistical mechanics. The scattering and simulation results reveal that changing the headgroup size is an important molecular knob in controlling morphological transitions. The molecular size ratio of the hydrophobic group to the hydrophilic group emerges as a crucial dimensionless quantity in our theory and plays a determining role in setting the micelle structure and the transition from mesoscale to macroscale aggregates. Our minimal theory is able to qualitatively explain the key features of the morphological phase diagram, including the prevalence of fiber-like structures in comparison to spherical and planar micelles. Together, these findings provide a more complete picture of the molecular dependencies of assemblies of inverse surfactants, which we hope may aid in the de novo design of supramolecular structures.

Christakopoulos, Panagiotis [ORNL] (ORCID:00090004↗

Nanometer-Scale Acoustic Wave Packets Generated by Stochastic Core-Level Photoionization Events

We demonstrate that the absorption of femtosecond hard x-ray pulses excites quasispherical, high-amplitude, and high-wave-vector coherent acoustic phonon wave packets using an all hard-x-ray pump-probe scattering experiment. The time- and momentum-resolved diffuse scattering signal is consistent with an ensemble of 3D strain wave packets induced by the rapid electron cascade dynamics following photoionization at uncorrelated excitation centers. We quantify key parameters of this process, including the localization size of the stress field and the photon energy conversion efficiency into elastic energy. The parameters are determined by the photoelectron and Auger electron cascade dynamics, as well as the electron-phonon interaction. In particular, we obtain the localization size of the observed strain wave packet to be 1.5 and 2.5 nm for bulk SrTiO 3 and KTaO 3 single crystals, respectively. The results provide crucial information on the mechanism of x-ray energy deposition into matter and shed light on the shortest collective length scales accessible to coherent acoustic phonon generation using x-ray excitation. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Quantifying dispersity in size and shape of nanoparticles from small-angle scattering data using machine learning based CREASE

Here, we use machine learning (ML) enhanced computational reverse engineering analysis of scattering experiments (CREASE) to interpret small-angle X-ray scattering (SAXS) data obtained from a system of nanoparticles without a priori knowledge of their exact shapes (e.g. spheres or ellipsoids), sizes (0.5–50 nm) and distributions. The SAXS measurements yielded three categories of scattering profiles exhibiting 'strong', 'weak' and 'no' features. Diminishing features (e.g. broadening or disappearing peaks) in scattering profiles have always been attributed to the presence of significant dispersity in the system. Such featureless SAXS data are not suitable for traditional analysis using analytical models. If one were to fit a relevant analytical model (e.g. the lmfit analytical model for polydisperse spheres) to these 'weak' and 'no' SAXS profiles from our nanoparticle systems, one would obtain non-unique interpretations of the data. Relying on electron microscopy to identify the distributions of nanoparticle shapes and sizes is also unfeasible, especially in high-throughput synthesis and characterization loops. In such situations, to identify the distributions of particle sizes and shapes that could be present in the sample, one must rely on methods like ML-CREASE to interpret the data quickly and output all relevant interpretations about the structure present in the system. The ML-CREASE optimization loop takes the experimental scattering profile as input and outputs multiple candidate solutions whose computed scattering profiles match the SAXS profile input. The ML-CREASE method outputs distributions of relevant structural features, such as the volume fraction of the nanoparticles in the system and the mean and standard deviation of the particle size and aspect ratio, assuming a type of distribution (e.g. normal, log-normal) for size and aspect ratio. We find that, for the SAXS profiles analyzed here, accounting for the shape dispersity along with size dispersity of the nanoparticles using ML-CREASE improved the match between the computed scattering profiles and input experimental profiles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Benchmarking of ENDF/B-VIII.1 Thermal Scattering Library for Hydrogen

In correctly characterizing the energy and momentum transfer at thermal and cold energies between neutrons and its interacting medium, thermal scattering libraries, which details energy states due to the intra- and inter-molecular bond effects for the medium materials, are applied in place of free-gas cross section libraries in a particle transport simulation code. They are essential to the neutron performance of a neutron facility like SNS, where thermalized neutrons from 20 K liquid hydrogen and ambient (~300 K) water are transported to the beamlines for neutron scattering experiments in studying materials. Recently, a new version of thermal scattering library for parahydrogen and orthohydrogen at 14-20 K was developed and to be released in ENDF/B-VIII.1. It is, therefore, important to benchmark its impacts on the prediction of moderator performance due to the updates in the thermal scattering library. In this study, the recent ENDF/B-VIII.1 thermal scattering library was compared to the current ENDF/B-VII.1 one in the neutron performance calculations for the decoupled and coupled hydrogen moderators at SNS under theorized and real working conditions. In addition, the predictions using both thermal scattering libraries were benchmarked to the measurements of moderator performance. The consistency between the libraries was observed mostly for parahydrogen and the difference in orthohydrogen at cold neutron energies was noted.

Lu, Wei [Oak Ridge National Laboratory (ORNL), Oak↗

Discoveries in Blast-Driven Turbulence of Astrophysical Relevance

The fluid mixing caused by variable-density instabilities is important in a wide variety of scenarios from ocean mixing and astrophysical phenomena to nuclear fusion techniques and atomic weapons. This thesis explores the mixing resulting from a specific instability known as the Blast Driven Instability (BDI). This work investigates the variable density mixing in an explosively driven environment due to the fluid instabilities at the material interfaces. Specifically, diverging Richtmyer-Meshkov (impulsive-acceleration environment) and Rayleigh-Taylor (variable-acceleration environment) instabilities (present in supernova and inertial confinement fusion) are studied using advanced high-speed diagnostics in carefully designed laboratory experiments. The BDI morphology is presented through a time development of Mie scattering images, and steps through the parameter space (varying density ratio and driver speed), highlighting the development of the structures that form during mixing. A scaling criterion is used to relate the two systems of vastly different spatiotemporal scales. Velocity fields in the BDI have been captured for the first time using the high temporal resolution PIV technique. Subsequent analysis of the dynamics of the instability from the velocity fields illustrates the distribution of kinetic energy, the transition to turbulence, and the characteristic growth of the instability are discussed. This study furthers understanding of how blast-driven instability pertains to supernova and inertial confinement fusion science. The morphology of the BDI has been characterized for the first time. This work steps through the parameter space covered in Mie scattering experiments, and how the different parameters contribute to development of structures and mixing. It also examines a scaling of the Atwood number for expanding predictive capabilities to other experimental conditions and simulations. The first collection of velocity fields acquired for the BDI are recorded, and subsequent analysis evaluating the distribution of kinetic energy throughout space and time for two density ratios from the overall parameter space, as well as the transition to turbulence, estimated from a Reynolds number calculated based on momentum mixing are all presented. This information is useful in advancing the development of models to predict physics of high energy density applications where experiments are not always readily available. This research has successfully demonstrated understanding for the time criteria defining regimes where the shock driven (Richtmyer-Meshkov instability) and the buoyancy driven (Rayleigh-Taylor instability) dominates through a parametric study of density variation (Atwood number) and driver speed (Mach number). All this furthers understanding of how the BDI pertains to SN and ICF.

79 ASTRONOMY AND ASTROPHYSICS↗

ESAC v1: Enhanced AI-Powered Chatbot for EQ-SANS Experiment Automation Improvements and Updates

ESAC (EQ-SANS Assisting Chatbot) is an advanced AI-powered application designed to streamline the workflow of neutron scattering experiments at the Spallation Neutron Source (SNS). This report documents the significant advancements in ESAC v1, which include the integration of a combined In-Context Learning (ICL) + Retrieval-Augmented Generation (RAG) capability, a robust integrated development environment, and standalone executable distribution. These enhancements address the limitations of the original version, making ESAC v1 a transformative tool for researchers. The report also discusses the technical challenges encountered during development and their resolution, highlighting the impact of these improvements on the neutron scattering research community.

36 MATERIALS SCIENCE↗

AutoSAC-Automated Sample Activation Calculation on VULCAN

AutoSAC is an automated python program to conduct sample activation calculation immediately after neutron scattering experiment on VULCAN. AutoSAC takes account of sample dimensions, compositions, forms, sample environments, neutron beam configurations, neutron scattering history, and proton charged resolved beam power etc., and uses a simplified method to rapidly estimate the radioactivity at end of beam or after. It generates a draft report per sample and repository of radioactivity per measurement and provides feedback of current radioactivity and decay time back to a neutron proposal Slack channel to inform users immediately on sample handling. It also utilizes either the sample note field in EPICS or sample composition or thickness correction and takes slack prompt or command to conduct post-beam SAC by demand. The program can be shared to be used in other beamlines at spallation neutron source with modified instrument configurations including instrument specific characteristic beam fluxes.

An, Ke [Oak Ridge National Laboratory (ORNL), Oak ↗

An ASME-Compliant Helium-4 Evaporation Refrigerator for the SpinQuest Experiment

This paper presents the design, safety basis, and commissioning results of a 1 K liquid helium-4 (4He) evaporation refrigerator developed for the Fermilab SpinQuest Experiment (E1039). The system represents the first high power helium evaporation refrigerator operated in a fixed target scattering experiment at Fermilab and was engineered to comply with the Fermilab ES&H Manual (FESHM) requirements governing pressure vessels, piping, cryogenic systems, and vacuum vessels. The design is mapped to ASME B31.3 (Process Piping) and the ASME Boiler and Pressure Vessel Code (BPVC) for pressure boundary integrity and overpressure protection, with documented compliance to FESHM Chapters 5031 (Pressure Vessels), 5031.1 (Piping Systems), and 5033 (Vacuum Vessels). This work documents the methodology used to reach compliance and approval for the 4He evaporation refrigerator at Fermilab which the field lacks. Design considerations specific to the high radiation target-cave environment including remotely located instrumentation approximately 20 m from the cryostat are summarized, together with the relief-system sizing methodology used to accommodate transient heat loads from dynamic nuclear polarization microwaves and the high-intensity proton beam. Commissioning data from July 2024 confirms that the system satisfies all thermal performance and safety objectives.

Roberts, Jordan D. [Virginia U.]↗

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron–proton and muon-proton scattering using the Paul Scherrer Institute’s πM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light nuclei femtoscopy and baryon interactions in 3 GeV Au+Au collisions at RHIC

We report the measurements of proton-deuteron (𝑝-𝑑) and deuteron-deuteron (𝑑-𝑑) correlation functions in Au + Au collisions at $\sqrt{s_{NN}}$ = 3 GeV using fixed-target mode with the STAR experiment at the Relativistic Heavy-Ion Collider (RHIC). For the first time, the source size (𝑅 𝐺 ), scattering length (𝑓 0 ), and effective range (𝑑 0 ) are extracted from the measured correlation functions with a simultaneous fit. The spin-averaged 𝑓 0 for 𝑝-𝑑 and 𝑑-𝑑 interactions are determined to be -5.28 ± 0.11(stat.) ± 0.82(syst.) fm and -2.62 ± 0.02(stat.) ±0.24(syst.) fm, respectively. The measured 𝑝-𝑑 interaction is consistent with theoretical calculations and low energy scattering experiment results, demonstrating the feasibility of extracting interaction parameters using the femtoscopy technique. The reasonable agreement between the experimental data and the calculations from the transport model indicates that deuteron production in these collisions is primarily governed by nucleon coalescence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collapse of Jahn-Teller phonons in La 1−x Sr x MnO 3 with weak magnetoresistance

Perovskite manganites are quantum materials exhibiting competing interactions inducing colossal magnetoresistance (CMR). The prevailing theory of CMR highlights the essential role of electron-phonon coupling (EPC), but mounting evidence suggests the underlying mechanism is more complicated. Here, we investigate phonons and spin-phonon coupling in ferromagnetic CMR manganites La 1−x Sr x MnO 3 (x=0.2,0.3) with relatively small CMR associated with melting of the magnetic order above room temperature. High-resolution neutron scattering experiments combined with density functional theory (DFT) show that the low-temperature ferromagnetic phase is conventional: neutron scattering from phonons agrees with DFT predictions and magnons follow sinusoidal dispersions. Fluctuating magnetic moments and low-energy phonons remain conventional in the high-temperature paramagnetic phase, indicating the Mn and La/Sr sublattices are not strongly perturbed by melting of ferromagnetism. In contrast, the Jahn–Teller-active optical oxygen vibrations collapse entirely above the Curie temperature, despite low CMR in these compositions, with some of the lost spectral weight reappearing as quasielastic scattering. We attribute this highly anomalous behavior to giant EPC in the charge and/or orbital channel. It drives cooperative diffusive motion of quasistatic carrier-trapping oxygen sublattice distortions once ferromagnetism disappears. We hypothesize the magnitude of magnetoresistance correlates with the rate of diffusion rather than with the strength of Jahn–Teller EPC.

36 MATERIALS SCIENCE↗

The MUSE beamline calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron–proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron–proton and muon–proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. Here, in this article, we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

Calorimeter↗

Temperature-dependent lattice dynamics in polycrystalline ZrN

Zirconium nitride holds promise for improving nuclear reactor components, where thermal conductivity is important, highlighting the need for a detailed understanding of its phonons. However, the phonon dispersion derived from previous inelastic neutron scattering data is in disagreement with modern theoretical calculations, pointing to the necessity for further experimental validation. Here, in this study, we use inelastic neutron scattering experiments on polycrystalline ZrN at 6, 100, 300, 400, and 600 K, and density functional theory (DFT) calculations to study the momentum-resolved scattering and the phonon density of states. Both experimental and theoretical results reveal a phonon cutoff energy near 65 meV, in stark disagreement with previous single-crystal neutron scattering measurements indicating a cutoff near 75 meV. The 65 meV cutoff energy is, however, in reasonable agreement with previous measurements on ZrN 0.9 . Consistency between our theoretical and experimental results confirms that ZrN is a wide phonon band gap system and that DFT provides a reliable description of its phonons.

DFT↗

Momentum-Resolved Direct Observation of Chiral Phonons in Elemental Tellurium

Chiral phonons carry finite phonon angular momentum, yet their momentum-resolved behavior in acoustic branches remains largely unexplored. In this work, we report the direct detection of chiral acoustic phonons in elemental Te. Through a combination of high-energy-resolution inelastic x-ray scattering experiments and atomistic modeling, we confirm that longitudinal acoustic modes develop pronounced circular atomic motion by mixing with transverse modes. Our results establish a direct link between unexpected scattering intensity in nominally forbidden geometries and circular phonons, offering a framework for characterizing momentum-resolved phonon chirality and highlighting the emergence of intrinsic phonon angular momentum in acoustic branches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of nuclear interaction cross sections towards neutron-skin thickness determination

The accuracy of reaction theories used to extract properties of exotic nuclei from scattering experiments is often unknown or not quantified, but of utmost importance when, e.g., constraining the equation of state of asymmetric nuclear matter from observables as the neutron-skin thickness. In order to test the Glauber multiple-scattering model, the total interaction cross section of 12 C on carbon targets was measured at initial beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The measurements were performed during the first experiment of the newly constructed R 3 B (Reaction with Relativistic Radioactive Beams) experiment after the start of FAIR Phase-0 at the GSI/FAIR facility with beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The combination of the large-acceptance dipole magnet GLAD and a newly designed and highly efficient Time-of-Flight detector enabled a precise transmission measurement with several target thicknesses for each initial beam energy with an experimental uncertainty of ±0.4%. A comparison with the Glauber model revealed a discrepancy of around 3.1% at higher beam energies, which will serve as a crucial baseline for the model-dependent uncertainty in future fragmentation experiments.

Astronomy & Astrophysics↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

The SHMS 11 GeV/c spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/ c , the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5° to 40°, thus allowing a wide range of low cross-section experiments to be conducted. Finally, these experiments complement and extend the previous Hall C research program to higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗