Pooled PPIseq: Screening the SARS-CoV-2 and human interface with a scalable multiplexed protein-protein interaction assay platform

Protein-Protein Interactions (PPIs) are a key interface between virus and host, and these interactions are important to both viral reprogramming of the host and to host restriction of viral infection. In particular, viral-host PPI networks can be used to further our understanding of the molecular mechanisms of tissue specificity, host range, and virulence. At higher scales, viral-host PPI screening could also be used to screen for small-molecule antivirals that interfere with essential viral-host interactions, or to explore how the PPI networks between interacting viral and host genomes co-evolve. Current high-throughput PPI assays have screened entire viral-host PPI networks. However, these studies are time consuming, often require specialized equipment, and are difficult to further scale. Here, we develop methods that make larger-scale viral-host PPI screening more accessible. This approach combines the mDHFR split-tag reporter with the iSeq2 interaction-barcoding system to permit massively-multiplexed PPI quantification by simple pooled engineering of barcoded constructs, integration of these constructs into budding yeast, and fitness measurements by pooled cell competitions and barcode-sequencing. We applied this method to screen for PPIs between SARS-CoV-2 proteins and human proteins, screening in triplicate >180,000 ORF-ORF combinations represented by >1,000,000 barcoded lineages. Our results complement previous screens by identifying 74 putative PPIs, including interactions between ORF7A with the taste receptors TAS2R41 and TAS2R7, and between NSP4 with the transmembrane KDELR2 and KDELR3. We show that this PPI screening method is highly scalable, enabling larger studies aimed at generating a broad understanding of how viral effector proteins converge on cellular targets to effect replication.

60 APPLIED LIFE SCIENCES

Effect of transient liquid flow on retention characteristics of screen acquisition systems

A design analysis, is developed based on experimental data, to predict the effects of transient flow and pressure surges (caused either by valve or pump operation, or by boiling of liquids in warm lines) on the retention performance of screen acquisition systems. A survey of screen liquid acquisition system applications was performed to determine appropriate system environment and classification. A screen model was developed which assumed that the screen device was a uniformly distributed composite orthotropic structure, and which accounted for liquid inflow/outflow, gas ingestion quality, screen stress, and liquid spill. A series of 177 tests using 13 specimens (5 screen meshes, 4 screen device construction/backup methods, and 2 orientations) with three test fluids (isopropyl alcohol, Freon 114, and LH2) provided data which verified important features of the screen model and resulted in a design tool which could accurately predict the transient startup performance acquisition devices.

Cady, E. C.

Effect of Vibration on Retention Characteristics of Screen Acquisition Systems

An analytical and experimental investigation of the effect of vibration on the retention characteristics of screen acquisition systems was performed. The functioning of surface tension devices using fine-mesh screens requires that the pressure differential acting on the screen be less than its pressure retention capability. When exceeded, screen breakdown will occur and gas-free expulsion of propellant will no longer be possible. An analytical approach to predicting the effect of vibration was developed. This approach considers the transmission of the vibration to the screens of the device and the coupling of the liquid and the screen in establishing the screen response. A method of evaluating the transient response of the gas/liquid interface within the screen was also developed.

Tegart, J. R.

The screen hole plasma sheath of an ion accelerator system

Results of the first probing of the screen hole sheath of an ion accelerator system are presented. The screen hole sheath, represented as a set of equipotential contours, extends over a large distance within the discharge plasma. Under no conditions examined does the sheath enter the screen hole. Edge hole defocusing of multiaperture accelerator systems is due primarily to local plasma density variations rather than adjacent screen hole sheath interactions. The sheath boundary is independent of screen-to-accelerator grid spacing when the grid set is operated at the minimum ion beam divergence condition. Significant ion focusing effects occur in the sheath adjacent to the screen grid webbing leading to increased ion source beam current efficiency with decreasing screen-to-accelerator grid separation and/or screen grid thickness.

Aston, G.

Measurement of Screen-Size Effects on Intensity, Scale, and Spectrum of Turbulence in a Free Subsonic Jet

The results are reported of hot-wire anemometer measurements of the fluctuating longitudinal component of the turbulent velocities in the mean flow downstream of screens in an air jet. These measurements have been analyzed by well-established techniques to give the influence of tile screen mesh size on the turbulent intensity, scale, and the power-spectral-density. The results show a linear dependence of the intensity upon the screen mesh size for locations within the central core of the air jet. The spectral-density curves show that the screens redistribute the turbulent energy from the low frequencies (<1000 cps) to the high frequencies (>1000 cps). The effects of the screens are overwhelmed in the mixing region of the jet flow by the turbulence levels existing there. The large pressure drops occurring across the screens reduce the velocity of the jet as compared to the jet without screens by approximately one-third for the velocity and range of mesh sizes investigated and reported in this report. The turbulence scale is a linear function of distance from the nozzle exit and is somewhat greater than comparable jets without screens.

Howard, Charles D.

An Automated Algorithm to Screen Massive Training Samples for a Global Impervious Surface Classification

An algorithm is developed to automatically screen the outliers from massive training samples for Global Land Survey - Imperviousness Mapping Project (GLS-IMP). GLS-IMP is to produce a global 30 m spatial resolution impervious cover data set for years 2000 and 2010 based on the Landsat Global Land Survey (GLS) data set. This unprecedented high resolution impervious cover data set is not only significant to the urbanization studies but also desired by the global carbon, hydrology, and energy balance researches. A supervised classification method, regression tree, is applied in this project. A set of accurate training samples is the key to the supervised classifications. Here we developed the global scale training samples from 1 m or so resolution fine resolution satellite data (Quickbird and Worldview2), and then aggregate the fine resolution impervious cover map to 30 m resolution. In order to improve the classification accuracy, the training samples should be screened before used to train the regression tree. It is impossible to manually screen 30 m resolution training samples collected globally. For example, in Europe only, there are 174 training sites. The size of the sites ranges from 4.5 km by 4.5 km to 8.1 km by 3.6 km. The amount training samples are over six millions. Therefore, we develop this automated statistic based algorithm to screen the training samples in two levels: site and scene level. At the site level, all the training samples are divided to 10 groups according to the percentage of the impervious surface within a sample pixel. The samples following in each 10% forms one group. For each group, both univariate and multivariate outliers are detected and removed. Then the screen process escalates to the scene level. A similar screen process but with a looser threshold is applied on the scene level considering the possible variance due to the site difference. We do not perform the screen process across the scenes because the scenes might vary due to the phenology, solar-view geometry, and atmospheric condition etc. factors but not actual landcover difference. Finally, we will compare the classification results from screened and unscreened training samples to assess the improvement achieved by cleaning up the training samples. Keywords:

Tan, Bin

Impact of the Screen Configurations on the Estimated Terra MODIS SD Degradation

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on-board the Aqua and Terra spacecraft have collected valuable Earth data for the last 19 and 21 years, respectively. MODIS is equipped with various on-orbit calibrators, including a solar diffuser (SD) and solar diffuser stability monitor (SDSM), that are used to monitor changes in the instrument’s gain over time. Nominally, SD calibrations alternate between two configurations: screen open and screen closed. Terra MODIS, however, experienced an anomaly in 2003, which has left the SD door and screen in a permanent open-closed configuration. This resulted in accelerated degradation of the SD on Terra MODIS due to the direct solar radiation exposure every orbit. It also led to an unexpected divergence between the calibration coefficients, m1, or the inverse of the gain, generated using SD data and those generated using lunar observations at the time of the 2003 anomaly. This paper examines the effect of the screen configuration on the Terra SD degradation by analyzing Terra SDSM data and comparing to Aqua. We generate “pseudo-open” Terra SDSM data by modeling the ratio of Aqua screen open and screen closed SDSM data and calculate the Terra SD degradation using this new screen open data. We then examine the effects on our m1 values calculated using this new pseudo-open SD degradation for Terra. Implementing this new degradation results in a smaller discrepancy between the lunar and SD m1 values after the door anomaly, indicating that there may be a systematic error in the SD degradation calculated with screen closed data.

MODIS

Investigation of the Effect of Gate Oxide Screening with Adjustment Pulse on Commercial SiC Power MOSFETs

This paper presents a method to recover the negative threshold voltage shift during high field gate oxide screening of 1.2 kV 4H-SiC MOSFETs with an additional adjustment gate voltage pulse. To reduce field failure rates of the MOSFETs in operation, manufacturers perform a screening treatment to remove devices with extrinsic defects in the oxide. Current gate oxide screening procedures are limited to oxide fields at or below ~9 MV/cm for short durations (<1 s), which is not enough to remove all the devices with extrinsic defects. The results show that by implementing a lower field gate pulse, the threshold voltage shift can be partially recovered, and therefore the maximum screening field and time can be increased. However, both the initial screening pulse and the adjustment pulse require careful calibration to prevent significant degradation of the device threshold voltage, on-resistance, interface state density, or intrinsic lifetime. With a well calibrated set of pulses, higher screening fields can be utilized without significantly damaging the devices. This leads to an improvement in the overall screening efficiency of the process, reducing the number of devices with extrinsic oxide defects entering the field, and improving the reliability of the SiC MOSFETs in operation.

42 ENGINEERING

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening

An artificial intelligence accelerated virtual screening platform for drug discovery

Abstract Structure-based virtual screening is a key tool in early drug discovery, with growing interest in the screening of multi-billion chemical compound libraries. However, the success of virtual screening crucially depends on the accuracy of the binding pose and binding affinity predicted by computational docking. Here we develop a highly accurate structure-based virtual screen method, RosettaVS, for predicting docking poses and binding affinities. Our approach outperforms other state-of-the-art methods on a wide range of benchmarks, partially due to our ability to model receptor flexibility. We incorporate this into a new open-source artificial intelligence accelerated virtual screening platform for drug discovery. Using this platform, we screen multi-billion compound libraries against two unrelated targets, a ubiquitin ligase target KLHDC2 and the human voltage-gated sodium channel Na V 1.7. For both targets, we discover hit compounds, including seven hits (14% hit rate) to KLHDC2 and four hits (44% hit rate) to Na V 1.7, all with single digit micromolar binding affinities. Screening in both cases is completed in less than seven days. Finally, a high resolution X-ray crystallographic structure validates the predicted docking pose for the KLHDC2 ligand complex, demonstrating the effectiveness of our method in lead discovery.

Science & Technology - Other Topics

Improvements in solid state radiographic converter screens.

Description of two different kinds of solid-state radiographic converter screens which have been developed. After briefly reviewing the working principles of the solid-state image converter - a sandwich type structure consisting of a photoconductive layer and an electroluminescent layer with a semiconductive layer and a black layer between them, two different kinds of radiographic converter screens are described - a radiographic amplifier screen that can be used as a substitute for the fluoroscopic screen, and a radiographic storage screen that can be used instead of radiographic films. The construction of both kinds of converters is fundamentally the same, the only difference being in the sensing photoconductive material. The radiographic amplifier screen has a moderately fast response, while the radiographic storage screen displays the image long after the irradiation is stopped.

Szepesi, Z.

Flow-induced resonance of screen-covered cavities

An experimental study of screen-covered cavities exposed to airflow tangent to the screen is described. The term screen refers to a thin metal plate perforated with a repetitive pattern of round holes. The purpose was to find the detailed aerodynamic and acoustic mechanisms responsible for screen-covered cavity resonance and to find ways to control the pressure oscillations. Results indicate that strong cavity acoustic resonances are created by screen orifices that shed vortices which couple resonance by choosing hole spacings such that shed vortices do not arrive at a downstream orifice in synchronization with cavity pressure oscillations. The proper hole pattern is effective at all airspeeds. It was also discovered that a reduction of orifice size tended to weaken the screen/cavity interaction regardless of hole pattern, probably because of viscous flow losses at the orifices. The screened cavities that resonated did so at much higher frequencies than the equivalent open cavity. The classical large eddy phenomenon occurs at the relatively small scale of the orifices (the excitation is typically of high frequency). The wind tunnel study was made at airspeeds from 0 to 100m/sec. The 457-mm-long by 1.09-m-high rectangular cavities had length-to-depth ratios greater than one, which is indicative of shallow cavities. The cavity screens were perforated in straight rows and columns with hole diameters ranging from 1.59 to 6.35 mm and with porosities from 2.6 to 19.6 percent.

Soderman, Paul T.

Display screen and method of manufacture therefor

A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. Compatible screen structures, along with methods for fabricating high resolution prescreens and methods and devices for maintaining the desired relationship between the prescreen and the diffusion screen are contemplated.

Dubin, Matthew B.

Determination of the SNPP VIIRS SDSM Screen Relative Transmittance From Both Yaw Maneuver and Regular On-Orbit Data

The Visible Infrared Imaging Radiometer Suiteaboard the Suomi National Polar-orbiting Partnership (SNPP) satellite performs radiometric calibration of its reflective solar bands primarily through observing a sunlit onboard solar diffuser (SD). The SD bidirectional reflectance distribution function(BRDF) degradation factor is determined by an onboard SD stability monitor (SDSM), which observes the Sun through a pinhole screen and the sunlit SD. The transmittance of the SDSM pinhole screen over a range of solar angles was determined prelaunch and used initially to determine the BRDF degradation factor.The degradation-factor-versus-time curves were found to have a number of very large unphysical undulations likely due to the inaccuracy in the prelaunch determined SDSM screen transmittance.To refine the SDSM screen transmittance, satellite yaw maneuvers were carried out. With the SDSM screen relative transmittance determined from the yaw maneuver data, the computed BRDFdegradation factor curves still have large unphysical ripples, indicating that the projected solar horizontal angular step size in the yaw maneuver data is too large to resolve the transmittance at a fine angular scale. We develop a methodology to use both the yaw maneuver and a small portion of regular on-orbit data to determine the SDSM screen relative transmittance at a fine angular scale. We determine that the error standard deviation of the calculated relative transmittance ranges from 0.00030 (672 nm) to 0.00092 (926 nm). With the newly determined SDSM screen relative transmittance, the computed BRDF degradation factor behaves much more smoothly over time.

Lei, Ning

Aviation security screening optimizer for risk and throughput (ASSORT)

The increasing number of air travelers each year presents a challenge as many airports are near their capacity in terms of resources and space for passenger screening. Fortunately, advancements in technologies like next-generation millimeter wave scanning offer solutions to ease this strain. The focus remains on managing risk while enhancing the passenger experience for the traveling public. The risk model presented in this paper known as the Aviation Security Screening Optimizer for Risk and Throughput (ASSORT) is designed to assess risk-based approaches for passenger screening and checkpoint operations. Additionally, ASSORT is exploring various traveler categories — general, trusted, and trusted-plus — along with different checkpoint screening Concept of Operations tailored to each traveler type. For instance, travelers with a higher trust level may experience fewer screening technologies, resulting in quicker processing times at the checkpoint. The output of ASSORT provides a risk score for predefined threat scenarios, as well as the overall risk to the checkpoint, aircraft, and airport by traveler type. In conclusion, benefits of using this tool include assessing the trade-offs between the overall risk associated with checkpoints and the throughput rate of passengers screened. We show for example the impact that different passenger volumes at the checkpoint can have on risk.

99 GENERAL AND MISCELLANEOUS

Phonon screening and dissociation of excitons at finite temperatures from first principles

The properties of excitons, or correlated electron–hole pairs, are of paramount importance to optoelectronic applications of materials. A central component of exciton physics is the electron–hole interaction, which is commonly treated as screened solely by electrons within a material. However, nuclear motion can screen this Coulomb interaction as well, with several recent studies developing model approaches for approximating the phonon screening of excitonic properties. While these model approaches tend to improve agreement with experiment, they rely on several approximations that restrict their applicability to a wide range of materials, and thus far they have neglected the effect of finite temperatures. Here, we develop a fully first-principles, parameter-free approach to compute the temperature-dependent effects of phonon screening within the ab initio GW -Bethe–Salpeter equation framework. We recover previously proposed models of phonon screening as well-defined limits of our general framework, and discuss their validity by comparing them against our first-principles results. We develop an efficient computational workflow and apply it to a diverse set of semiconductors, specifically AlN, CdS, GaN, MgO, and SrTiO 3 . We demonstrate under different physical scenarios how excitons may be screened by multiple polar optical or acoustic phonons, how their binding energies can exhibit strong temperature dependence, and the ultrafast timescales on which they dissociate into free electron–hole pairs.

Science & Technology - Other Topics

Characteristics of a cost-effective blood test for colorectal cancer screening

Background: Blood-based biomarker tests can potentially change the landscape of colorectal cancer (CRC) screening. We characterize the conditions under which blood test screening would be as effective and cost-effective as annual fecal immunochemical testing or decennial colonoscopy. Methods: We used the 3 Cancer Information and Surveillance Modeling Network–Colon models to compare scenarios of no screening, annual fecal immunochemical testing, decennial colonoscopy, and a blood test meeting Centers for Medicare & Medicaid (CMS) coverage criteria (74% CRC sensitivity and 90% specificity). We varied the sensitivity to detect CRC (74%-92%), advanced adenomas (10%-50%), screening interval (1-3 years), and test cost ($25-$500). Primary outcomes included quality-adjusted life-years (QALY) gained from screening and costs for a US average-risk cohort of individuals aged 45 years. Results: Annual fecal immunochemical testing yielded 125-163 QALY gained per 1000 at a cost of 3811-5384 dollars per person, whereas colonoscopy yielded 132-177 QALY gained at a cost of 5375-7031 dollars per person. A blood test with 92% CRC sensitivity and 50% advanced adenoma sensitivity yielded 117-162 QALY gained if used every 3 years and 133-173 QALY gained if used every year but would not be cost-effective if priced above $$125 per test. If used every 3 years, a $500 blood test only meeting CMS coverage criteria yielded 83-116 QALY gained at a cost of $8559-$9413 per person. Conclusion: Blood tests that only meet CMS coverage requirements should not be recommended to patients who would otherwise undergo screening by colonoscopy or fecal immunochemical testing because of lower benefit. Blood tests need higher advanced adenoma sensitivity (above 40%) and lower costs (below $125) to be cost-effective.

60 APPLIED LIFE SCIENCES