Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

Optical Engine Lockout System Design and Operation

Engine run days in the Diesel Combustion and Fuel Effects Lab are hectic. The long mental lists that must be kept by engine operators, paired with the tight time constraints between experiments, can cause operational issues that may be dangerous to personnel and/or cause damage to test equipment. Until now, a paper sign has been used to warn operators not to motor the engine when a foreign object has been placed inside of it. Unfortunately, this simple administrative control has failed in the past, motivating this effort to develop an improved system. The lockout system described in this document introduces an engineering control that, when activated, actually prevents the engine from being motored. The new system consists of a primary and a secondary control panel. Prior to an operator placing a foreign object into the cylinder, they press a button on the secondary control panel near the engine. This breaks the interlock circuit for the engine dynamometer and activates LEDs on both control panels to notify operators that a foreign object is present within the engine cylinder. Once the work is done and all foreign objects have been removed from the combustion chamber, two operators must be present to disable the system by simultaneously pressing the buttons on the primary and secondary control panels. Requiring a second operator to disable the system increases accountability and reduces the likelihood of potentially costly mistakes.

42 ENGINEERING↗

On Control Schemes for Grid-Forming Inverters

Grid-forming inverters can collaboratively regulate the voltage and frequency of a microgrid. These inverters are expected to be seen more in the future microgrid, undertaking the roles of the conventional power generators. Like conventional power generators, they must balance supply and demand, contribute to power-sharing between inverters and other power generators, and restore the voltage and frequency after any power changes. These technical challenges are typically achieved through different primary and secondary controllers. This article reviews some state-of-the-art primary and secondary control schemes for the emerging technology of grid-forming inverters. First, the typical control schemes for grid-following inverters are briefly presented for the continuity of the discussion on the roles of the grid-forming inverters in future power-grid, followed by two basic control schemes for the grid-forming inverters. Then, two decentralized power-sharing techniques, i.e., droop, and virtual inertia, are analyzed. The technical challenges for inverter synchronization and some control methods are discussed afterward. Finally, several secondary control methods for the voltage and frequency restoration in grid-forming inverters are reviewed.

Sadeque, Fahmid↗

Secondary Frequency Control for Reconfigurable Interconnecting Microgrids

Microgrids and microgrid technologies offer an operations and control framework for realizing the needed aggregation of a growing share of distributed energy resources. As the number of microgrids increases, so will the incentive to interconnect them, leading to a combinatorial growth of potential operating states. At the same time, their growing complexity nudges interconnected microgrids conceptually closer to balancing authorities in the bulk power system. This paper focuses on secondary frequency control and leverages the conceptual similarity between balancing authorities and interconnected microgrids to adopt an automatic generation control design with some adaptations. Frequency control and restoration is demonstrated via several use-cases with switching and reconfiguration events.

Schweitzer, Eran↗

Intrusion Detection for Cybersecurity of Power Electronics Dominated Grids: Inverters PQ Set-Points Manipulation

This work provides cybersecurity analytics for a high photovoltaic (PV) penetrated distribution network, representing future power electronics dominated grid (PEDG). Firstly, the impact of active and reactive power (PQ) set-points manipulation on the network is studied. Then, an intrusion detection system (IDS) is developed for identifying the potentially compromised PV inverters in the network. The proposed IDS is based on defining the normal, safe, and abnormal operation regions of the PV inverters from point of view of the steady state voltage stability of the network. These three-operation regions are identified by utilizing active power, reactive power, and voltage (PQV) limits of each specific grid-following inverter in the network. Each grid-following inverter's PQV contour includes the information of network topology, inverter ratings, and inverter controller. The developed PQ limits are integrated into the centralized secondary control layer for realization of the proposed IDS. Furthermore, the proposed secondary control layer is capable of providing remedial actions during an anomaly event to enhance the grid resiliency. The theoretical analyses are verified by several attack scenarios for a network of grid-following inverters.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

State-Constrained Grid-Forming Inverter Control for Robust Operation of AC Microgrids

The control of grid-forming inverters has become an important problem to achieve high efficiency, reliability, and resilience of the future power grid. The distributed control that utilizes a sparse communication network has been proposed for AC microgrids, in which each DG only has access to the information of a small number of its neighboring DGs, reducing the computational complexity and improving the resiliency to faults and unknown parameters. However, these approaches have not provided a clear analysis of the coupling between active/reactive power injections and the voltage magnitude/frequency or a distributed updating law with a solid theoretical foundation. Additionally, in the existing approaches, tracking the references from the secondary control may violate operational constraints.

Xu, Ying↗

Methods to Synchronize and Control the Secondary Side Active Rectifier in Wireless Power Transfer Systems

This paper presents practical analog circuit-based methods to synchronize the secondary side active bridge of different wireless power transfer (WPT) systems with their primary side. The synchronization is necessary for proper operation of any WPT system with an active bridge on the secondary. The proposed schemes use only secondary side signals without the need of any information from the primary side. Simulation results presented validate the proposed schemes.

Mukherjee, Subho↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance: Preprint

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Virtual Agents-Based Attack-Resilient Distributed Control for Islanded AC Microgrid

Due to its dependence on a communication network, distributed secondary control of microgrids is susceptible to denial-of-service (DoS) attacks in channel shutdown mode, which may negatively impact the network connectivity and thus deteriorate the coordination and power sharing among distributed generators (DGs). Honeypot is a common method for cyber deception by introducing fake targets. However, in the context of microgrid, the misleading information spread by honeypots will also impact the system performance. This paper proposes an attack-resilient distributed control for AC microgrids utilizing virtual agents (VAs) to counteract both DoS edge and node attacks. The VAs are designed to not impact the system’s steady state during normal operation but to share information among neighboring real agents and serve as dummy targets for DoS attacks. The control with VAs is implemented by a primal-dual gradient based distributed algorithm to efficiently obtain a practical solution for voltage/frequency regulation and power sharing. The simulation results on a 4-DG test system and a modified IEEE 34-bus system show that 1) VAs do not impact the normal functionality of the test system, and 2) deploying VAs can enhance the resilience of the microgrid control against DoS edge and node attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible tape-drive target system for secondary high-intensity laser-driven sources

Here, we present the development of a flexible tape-drive target system to generate and control secondary high-intensity laser-plasma sources. Its adjustable design permits the generation of relativistic MeV particles and x rays at high-intensity (i.e., ≥1 × 10 18 W cm —2 ) laser facilities, at high repetition rates (>1 Hz). The compact and robust structure shows good mechanical stability and a high target placement accuracy (<4 μm RMS). Its compact and flexible design allows for mounting in both the horizontal and vertical planes, which makes it practical for use in cluttered laser-plasma experimental setups. The design permits ~170° of access on the laser-driver side and 120° of diagnostic access at the rear. A range of adapted apertures have been designed and tested to be easily implemented to the targetry system. The design and performance testing of the tape-drive system in the context of two experiments performed at the COMET laser facility at the Lawrence Livermore National Laboratory and at the Advanced Lasers and Extreme Photonics (ALEPH) facility at Colorado State University are discussed. Experimental data showing that the designed prototype is also able to both generate and focus high-intensity laser-driven protons at high repetition rates are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

Peer-to-peer Communication Control Architecture for Engaging Ubiquitous DERs to Support Distribution System Resiliency

In this project, we developed a leader-follower consensus (LFC) control architecture to coordinate between GFM and GFL inverters with the former being leaders and the latter being followers. The objective is to simultaneously achieve a fast frequency and voltage regulation along with accurate real power and var sharing among all inverters under various disturbances. The distinction of our work is that we consider both GFM and GFL inveters for frequency and voltage regulations. In addition, rather than a standard consensus algorithm, our work utilized a leader-follower consensus algorithm which exploits the physical characteristics of GFM-GFL inverters: (i) the GFM inverters directly control frequency and voltage, and hence, serve as leaders, (ii) the GFL inverters measure frequency/voltage to modulate their outputs, and hence, they should serve as followers. The effectiveness of the proposed LFC coordination was tested on a networked microgrid test system under different disturbances and communication degradation events. We demonstrated that the proposed fully coordinated control is robust to disturbances, while outperforming uncoordinated and GFM-only coordinated approaches. Overall, this work emphasized the necessity and benefits of the GFMGFL coordination in the secondary control of microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Enhancing the distribution grid resilience using cyber-physical oriented islanding strategy

The increasing penetration of distributed generations enables an innovative operation paradigm that allows islanded operation to enhance the resilience of the distribution grid. In this study, a cyber-physical oriented islanding strategy is proposed by coordinating centralised and distributed control to achieve seamless islanding transition and operational flexibility in emergency conditions. A cyber-physical control structure is developed to mitigate various disturbances (e.g. emergencies or fluctuations) according to different operation conditions. Specifically, the distributed fault isolation and seamless islanding transition are coordinated to mitigate the outage caused by unplanned islanding, while a secondary control is proposed to support primary control by reducing the power fluctuations during islanded operation. With a rapid response speed, the local cyber-physical devices are coordinated to accomplish islanding separation by selecting a feasible islanded area even under an unplanned islanding situation. A field test was conducted on a practical distribution network in China, and the results demonstrated the effectiveness and feasibility of the proposed islanding strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilizing grid–supportive load response to shape resilient frequency control of the power grid

The increasing penetration of renewable energy sources and the retirement of conventional generation units have decreased system inertia, making power systems more vulnerable to resilience and stability issues. To address this problem, this paper proposes a novel approach using grid-supportive loads (GSLs) to provide a fast and concise primary frequency response and a deep deterministic policy gradient agent-based secondary controller to restore the system frequency to the nominal value. The proposed method is evaluated on the single-area and multi-area test systems. The simulation results demonstrate that using GSLs enhances the power system's stability and resilience. Compared to conventional controllers, the frequency nadir is improved with GSLs. Additionally, the proposed method effectively enhances resilience even with high penetration. These findings indicate that the proposed approach can improve the resilience and stability of power systems and provide a promising solution for future power systems. The results of this study underscore the importance of utilizing innovative approaches to enhance the stability and resilience of power systems in the context of high penetration of renewable energy sources and the retirement of conventional generation.