Search NASA⌕ Search

SEARCH · Search NASA

Results for “secondary cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NASA GRC's High Pressure Burner Rig Facility and Materials Test Capabilities

The High Pressure Burner Rig (HPBR) at NASA Glenn Research Center is a high-velocity. pressurized combustion test rig used for high-temperature environmental durability studies of advanced materials and components. The facility burns jet fuel and air in controlled ratios, simulating combustion gas chemistries and temperatures that are realistic to those in gas turbine engines. In addition, the test section is capable of simulating the pressures and gas velocities representative of today's aircraft. The HPBR provides a relatively inexpensive. yet sophisticated means for researchers to study the high-temperature oxidation of advanced materials. The facility has the unique capability of operating under both fuel-lean and fuel-rich gas mixtures. using a fume incinerator to eliminate any harmful byproduct emissions (CO, H2S) of rich-burn operation. Test samples are easily accessible for ongoing inspection and documentation of weight change, thickness, cracking, and other metrics. Temperature measurement is available in the form of both thermocouples and optical pyrometery. and the facility is equipped with quartz windows for observation and video taping. Operating conditions include: (1) 1.0 kg/sec (2.0 lbm/sec) combustion and secondary cooling airflow capability: (2) Equivalence ratios of 0.5- 1.0 (lean) to 1.5-2.0 (rich), with typically 10% H2O vapor pressure: (3) Gas temperatures ranging 700-1650 C (1300-3000 F): (4) Test pressures ranging 4-12 atmospheres: (5) Gas flow velocities ranging 10-30 m/s (50-100) ft/sec.: and (6) Cyclic and steady-state exposure capabilities. The facility has historically been used to test coupon-size materials. including metals and ceramics. However complex-shaped components have also been tested including cylinders, airfoils, and film-cooled end walls. The facility has also been used to develop thin-film temperature measurement sensors.

Robinson, R. Craig↗

Non-Toxic, Low-Freezing, Drop-In Replacement Heat Transfer Fluids

A non-toxic, non-flammable, low-freezing heat transfer fluid is being developed for drop-in replacement within current and future heat transfer loops currently using water or alcohol-based coolants. Numerous water-soluble compounds were down-selected and screened for toxicological, physical, chemical, compatibility, thermodynamic, and heat transfer properties. Two fluids were developed, one with a freezing point near 0 C, and one with a suppressed freezing point. Both fluids contain an additive package to improve material compatibility and microbial resistance. The optimized sub-zero solution had a freezing point of 30 C, and a freezing volume expansion of 10-percent of water. The toxicity of the solutions was experimentally determined as LD(50) greater than 5g/kg. The solutions were found to produce minimal corrosion with materials identified by NASA as potentially existing in secondary cooling loops. Thermal/hydrodynamic performance exceeded that of glycol-based fluids with comparable freezing points for temperatures Tf greater than 20 C. The additive package was demonstrated as a buffering agent to compensate for CO2 absorption, and to prevent microbial growth. The optimized solutions were determined to have physically/chemically stable shelf lives for freeze/thaw cycles and longterm test loop tests.

Cutbirth, J. Michael↗

Water cooling system for an air-breathing hypersonic test vehicle

This study provides concepts for hypersonic experimental scramjet test vehicles which have low cost and low risk. Cryogenic hydrogen is used as the fuel and coolant. Secondary water cooling systems were designed. Three concepts are shown: an all hydrogen cooling system, a secondary open loop water cooled system, and a secondary closed loop water cooled system. The open loop concept uses high pressure helium (15,000 psi) to drive water through the cooling system while maintaining the pressure in the water tank. The water flows through the turbine side of the turbopump to pump hydrogen fuel. The water is then allowed to vent. In the closed loop concept high pressure, room temperature, compressed liquid water is circulated. In flight water pressure is limited to 6000 psi by venting some of the water. Water is circulated through cooling channels via an ejector which uses high pressure gas to drive a water jet. The cooling systems are presented along with finite difference steady-state and transient analysis results. The results from this study indicate that water used as a secondary coolant can be designed to increase experimental test time, produce minimum venting of fluid and reduce overall development cost.

Petley, Dennis H.↗

Operando X-Ray Diffraction During High Temperature Electrolysis

This work presents the design, development, and deployment of an operando X-ray diffraction (XRD) system for high-temperature electrolysis (HTE), enabling real-time characterization of solid oxide electrolysis cells (SOECs) under true operational conditions. The integration of an HTE test stand within a synchrotron radiation environment, mimicking the conditions of a laboratory setup, aims to enhance our understanding of the degradation processes affecting the performance and longevity of SOECs. Utilizing a custom furnace and a high precision motor stack assembly at the Stanford Synchrotron Radiation Lightsource (SSRL), the system revealed unparalleled insights into the structural evolution of SOEC components through various operational stages, including initial heat ramp, cell reduction, fuel ramp, and wet electrolysis. Initial results demonstrate the significant impact of the initial heating and cooling on secondary phase formation within the SOEC, highlighting the utility of operando XRD for developing more efficient and durable hydrogen production technologies.

08 HYDROGEN↗

Skylab ultraviolet stellar spectra - Cool stars with hot secondaries

A hot companion to the G5 III star HR 3080, a single-line spectroscopic binary, has been discovered from spectra in the vacuum-ultraviolet. The companion must be a subdwarf or pre-white dwarf. A list of previously known systems of the zeta Aur and VV Cep type observed with the ultraviolet spectrograph on Skylab is also given.

Parsons, S. B.↗

Solidification study of some Ni- and Co-base alloys

An ongoing research program aims to characterize the solidification of several Ni- and Co-based commercial wrought type alloys. The techniques used and the data items sought are: (1) thermal analysis, liquidus, nonequilibrium solidus as a function of cooling rate, secondary reactions temperatures, incipient melting, progress of solidification as a function of temperature; (2) optical metallography, characteristic structures and secondary dendrite arm spacing as a function of cooling rate; (3) X-ray diffraction, identification of precipitates; and (4) SEM/EDAX, measure of microsegregation.

Jeanfils, C. L.↗

Analytical Review of Exploration Extravehicular Mobility Unit Heat Rejection Performance

The Primary Thermal Control Loop (PTCL) in the Exploration Extravehicular Mobility Unit (xEMU) uses a Spacesuit Water Membrane Evaporator (SWME) to provide cooling for the crew member and spacesuit avionics. A secondary emergency cooling system, the Auxiliary Thermal Control Loop (ATCL), also uses a smaller version of the SWME, called the Mini-ME, in the event of a failure in the primary system. These are integral to the comfort of the crew member (through heat rejection) during an Extravehicular Activity (EVA). This paper examines the effectiveness of the heat rejection of the PTCL and the ATCL during thermal vacuum testing and the absolute limit of heat rejection to maintain an approximately 10C outlet temperature. During this thermal vacuum test, the PTCL was taken from a heat input of 0W up to 900W, far past the design point, and the ATCL was tested from 0W to 300W. Testing showed that the PTCL and the ATCL can maintain crew member outlet temperature throughout an entire 8-hour thermally controlled EVA environment (hot and cold). The results and effectiveness of the test will be detailed throughout this paper for all EVAs (whether a full mapping profile or a standard continuous heat load).

PLSS↗

An Experimental Investigation of Heat Transfer for Supercritical Carbon Dioxide Cooling in a Staggered Pin Fin Array

Pin fin geometry in the trailing edge as turbulators in tur-bine blades has been a subject thoroughly researched for the past several decades. To improve the efficiency of turbomachinery, higher turbine inlet temperatures are necessary, introducing the need for internal cooling channel features, such as pin fin arrays. These solutions are necessary to avoid material failure at higher operating conditions by enhancing the heat transfer of the blade. Over the past decade, a shift toward applying supercritical carbon dioxide or sCO2 cycles has shown increased potential compared to the industry standard air cycles. Promising higher cycle ef¬ficiency, smaller footprints, and zero greenhouse gas emissions, sCO2 has become an attractive alternative to well-established air cycles. This alternative cycle introduces the need to re-visit the heat transfer capabilities of internal cooling geometries within this novel operating fluid environment. The first objective of this paper is to experimentally demonstrate the heat transfer charac-teristics of sCO2 as the secondary internal cooling fluid environ¬ment through testing a pin fin array in a closed loop at 200 bar and 400 Celsius inlet conditions, which stands well within the supercritical region of sCO2. Secondly, the experimental process aims to validate numerical simulation methodology for studying sCO2 environments for internal cooling of turbine blades in a matching pin fin geometry.

Wardell, Ryan J↗

Cooling system and insulation concept for a Mach 5 turbo-ramjet aircraft

A cooling system and insulation concept for a Mach 5 cruise aircraft, using non-cryogenic fuel is presented. Catalytic endothermic reaction of petroleum fuel is used as the heat sink for engine cooling. A secondary closed-loop coolant circuit removes heat from the engine and transfers this heat to the catalytic reactor. Insulation on the engine flow path surfaces reduces the cooling requirements. A high temperature insulation system, which is capable of a surface temperature of 4,000 F, is used for the combustor and nozzle. A complete closed-loop cooling system design is shown in detail. Main features of this system include a fuel preheater, a catalytic fuel reactor, and engine wall cooling panels. A silicone-based liquid polymer, designed for extended use at 750 F, is used as the coolant. The preheater and reactor design are based on the results of recent experimental work. The cooling panels are designed using a thermal fluid analysis computer program, which was originally developed for the National Aero-Space Plane (NASP). Major components are analyzed structurally as well as thermally and weights are presented.

Jones, S. C.↗

Flaring and Spot Activities on the Semi-detached Binary System KIC 06852488

The continuous and unbroken time-series photometry data of Kepler and the Transiting Exoplanet Survey Satellite (TESS) provide a good opportunity to study the continuous variations in the light curve of binary stars. This paper reports the discoveries of the correlation between the two maxima on the light curve of KIC 06852488 and the correlation between the O’Connell effect and the O – C curve. The Max I and Max II vary with a same cycle length of ~2000 days and a 180° phase difference, and the variation of the Max II coincides with the O – C curve of the primary light minima. After analyzing the Kepler and TESS light curves, it is detected that this binary is a semi-detached system with a mass ratio of 0.4622(±0.0036). The secondary component is filling its critical Roche lobe, while the primary component is only filling 12.25(±0.10)% of the lobe volume that contributes more than 85% luminosity of the total system. The variation of the O’Connell effect could be explained by an evolving hot spot on the primary component and an evolving cool spot on the secondary component. It is found that their positions are symmetrical with the inner Lagrange L1 point. After subtracting the binary brightness changes, six optical flares are detected that come from the cool secondary. We calculated the energy of flares and found that all of the flares are superflares. Both the flares and an evolving dark spot on the lobe-filling secondary component make the system a very interesting source to investigate the effects of binary interaction on the magnetic activities.

47 OTHER INSTRUMENTATION↗

Cold Climate Air Source Heat Pumps (ccASHPs) Technology

This report describes cold climate air source heat pump technology. Cold climate air source heat pumps (ccASHPs) are a variation of an existing air conditioning technology - heat pumps - that are designed to heat homes adequately in very cold weather (usually at or below 5 degrees F) and, as a secondary function, cool these homes during warm weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observational studies of the symbiotic stars. III High-dispersion IUE and H-alpha observations of EG Andromedae

High-dispersion IUE and optical spectra are presented for the symbiotic star EG Andromedae (HD 4174). Remarkable emission-line strength and profile variations are confirmed for the S IV, O IV, C IV, and He II ultraviolet lines as well as H-alpha. Accurate cross-correlation absorption-line velocities determined from Ti I, Ca I, and Fe I features convincingly demonstrate that EG And is a single-lined spectroscopic binary. The velocity curve suggests that the photometric ephemeris reported by Smith in 1980 should be revised by a redefinition of zero phase by about 0.08 of a period. The primary of the system may be similar to the central star of a planetary nebula embedded in a dense nebula with a mild stellar wind. The behavior of the emission lines is interpreted to indicate that the primary and its surrounding nebula suffer a partial eclipse by the cool giant secondary.

Oliversen, N. A.↗

Preliminary Air-Flow and Thrust Calibrations of Several Conical Cooling-Air Ejectors with a Primary to Secondary Temperature Ratio of 1.0: Diameter Ratios of 1.06 and 1.40 - 2

An investigation was made of the performance of nine conical cooling-air ejectors at primary jet pressure ratios from 1 to 10, secondary pressure ratios to 4.0, and a temperature ratio of unity. This phase of the investigation was limited to conical ejectors having shroud exit to primary nozzle exit diameter ratios of 1.06 and 1.40, with several spacing ratios for each. The experimental results indicated that the pumping range and amount of cooling-air flow obtained with a 1.06 diameter ratio ejector were relatively small for cooling purposes but that the maximum possible thrust loss, which occurred with no secondary flow, was only 7 percent of convergent nozzle thrust. The 1.40 diameter ratio ejector produced a large cooling air flow and showed a possible thrust loss of 29.5 percent with no cooling air flow. Thrust gains were attained with ejectors of both diameter ratios at secondary pressure ratios greater than 1.0. The limiting primary pressure ratio below which an ejector can operate at a specific secondary pressure ratio (cut-off point) may be estimated for various flight conditions from data contained herein.

Greathouse, W. K.↗

Direct heating surface combustor

The combustor utilizes a non-adiabatic flame to provide low-emission combustion for gas turbines. A fuel-air mixture is directed through a porous wall, the other side of which serves as a combustion surface. A radiant heat sink disposed adjacent to and spaced from the combustion surface controls the combustor flame temperature in order to prevent the formation of oxides of nitrogen. A secondary air flow cools the heat sink. Additionally, up to 100% of secondary air flow is mixed with the combustion products at the direct heating surface combustor to dilute such products thereby reducing exit temperature. However, if less than 100% secondary air is mixed to the combustor, the remainder may be added to the combustion products further downstream.

Beremand, D. G.↗

Mini-Membrane Evaporator for Contingency Spacesuit Cooling

The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini- ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

Makinen, Janice V.↗

Mini-Membrane Evaporator for Contingency Spacesuit Cooling

The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only approximately 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini-ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

Makinen, Janice V.↗

Wavenumber dependent investigation of the terrestrial infrared radiation budget with two versions of the LOWTRAN5 band model

Two versions of the LOWTRAN5 radiance code are used in a study of the earth's clear sky infrared radiation budget in the interval 30 per cm (333.3 microns) to 3530 per cm (2.8 microns). One version uses 5 per cm resolution and temperature dependent molecular absorption coefficients, and the second uses 20 per cm resolution and temperature independent molecular absorption coefficients. Both versions compare well with Nimbus 3 IRIS spectra, with some discrepancies at particular wavenumber intervals. Up and downgoing fluxes, calculated as functions of latitude, are displayed for wavenumbers at which the principle absorbers are active. Most of the variation of the fluxes with latitude is found in the higher wavenumber intervals for both clear and cloudy skies. The main features of the wavenumber integrated cooling rates are explained with reference to calculations in more restricted wavenumber intervals. A tropical lower tropospheric cooling maximum is produced by water vapor continuum effects in the 760-1240 per cm window. A secondary upper tropospheric cooling maximum, with wide meridional extent, is produced by water vapor rotational lines between 30-430 per cm. Water vapor lines throughout the terrestrial infrared spectrum prevent the upflux maximum from coinciding with the surface temperature maximum.

Charlock, T. P.↗