Search NASA⌕ Search

SEARCH · Search NASA

Results for “secondary cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cooling system and insulation concept for a Mach 5 turbo-ramjet aircraft

A cooling system and insulation concept for a Mach 5 cruise aircraft, using non-cryogenic fuel is presented. Catalytic endothermic reaction of petroleum fuel is used as the heat sink for engine cooling. A secondary closed-loop coolant circuit removes heat from the engine and transfers this heat to the catalytic reactor. Insulation on the engine flow path surfaces reduces the cooling requirements. A high temperature insulation system, which is capable of a surface temperature of 4,000 F, is used for the combustor and nozzle. A complete closed-loop cooling system design is shown in detail. Main features of this system include a fuel preheater, a catalytic fuel reactor, and engine wall cooling panels. A silicone-based liquid polymer, designed for extended use at 750 F, is used as the coolant. The preheater and reactor design are based on the results of recent experimental work. The cooling panels are designed using a thermal fluid analysis computer program, which was originally developed for the National Aero-Space Plane (NASP). Major components are analyzed structurally as well as thermally and weights are presented.

Jones, S. C.↗

Observational studies of the symbiotic stars. III High-dispersion IUE and H-alpha observations of EG Andromedae

High-dispersion IUE and optical spectra are presented for the symbiotic star EG Andromedae (HD 4174). Remarkable emission-line strength and profile variations are confirmed for the S IV, O IV, C IV, and He II ultraviolet lines as well as H-alpha. Accurate cross-correlation absorption-line velocities determined from Ti I, Ca I, and Fe I features convincingly demonstrate that EG And is a single-lined spectroscopic binary. The velocity curve suggests that the photometric ephemeris reported by Smith in 1980 should be revised by a redefinition of zero phase by about 0.08 of a period. The primary of the system may be similar to the central star of a planetary nebula embedded in a dense nebula with a mild stellar wind. The behavior of the emission lines is interpreted to indicate that the primary and its surrounding nebula suffer a partial eclipse by the cool giant secondary.

Oliversen, N. A.↗

Preliminary Air-Flow and Thrust Calibrations of Several Conical Cooling-Air Ejectors with a Primary to Secondary Temperature Ratio of 1.0: Diameter Ratios of 1.06 and 1.40 - 2

An investigation was made of the performance of nine conical cooling-air ejectors at primary jet pressure ratios from 1 to 10, secondary pressure ratios to 4.0, and a temperature ratio of unity. This phase of the investigation was limited to conical ejectors having shroud exit to primary nozzle exit diameter ratios of 1.06 and 1.40, with several spacing ratios for each. The experimental results indicated that the pumping range and amount of cooling-air flow obtained with a 1.06 diameter ratio ejector were relatively small for cooling purposes but that the maximum possible thrust loss, which occurred with no secondary flow, was only 7 percent of convergent nozzle thrust. The 1.40 diameter ratio ejector produced a large cooling air flow and showed a possible thrust loss of 29.5 percent with no cooling air flow. Thrust gains were attained with ejectors of both diameter ratios at secondary pressure ratios greater than 1.0. The limiting primary pressure ratio below which an ejector can operate at a specific secondary pressure ratio (cut-off point) may be estimated for various flight conditions from data contained herein.

Greathouse, W. K.↗

Direct heating surface combustor

The combustor utilizes a non-adiabatic flame to provide low-emission combustion for gas turbines. A fuel-air mixture is directed through a porous wall, the other side of which serves as a combustion surface. A radiant heat sink disposed adjacent to and spaced from the combustion surface controls the combustor flame temperature in order to prevent the formation of oxides of nitrogen. A secondary air flow cools the heat sink. Additionally, up to 100% of secondary air flow is mixed with the combustion products at the direct heating surface combustor to dilute such products thereby reducing exit temperature. However, if less than 100% secondary air is mixed to the combustor, the remainder may be added to the combustion products further downstream.

Beremand, D. G.↗

Mini-Membrane Evaporator for Contingency Spacesuit Cooling

The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini- ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

Makinen, Janice V.↗

Mini-Membrane Evaporator for Contingency Spacesuit Cooling

The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only approximately 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini-ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

Makinen, Janice V.↗

Wavenumber dependent investigation of the terrestrial infrared radiation budget with two versions of the LOWTRAN5 band model

Two versions of the LOWTRAN5 radiance code are used in a study of the earth's clear sky infrared radiation budget in the interval 30 per cm (333.3 microns) to 3530 per cm (2.8 microns). One version uses 5 per cm resolution and temperature dependent molecular absorption coefficients, and the second uses 20 per cm resolution and temperature independent molecular absorption coefficients. Both versions compare well with Nimbus 3 IRIS spectra, with some discrepancies at particular wavenumber intervals. Up and downgoing fluxes, calculated as functions of latitude, are displayed for wavenumbers at which the principle absorbers are active. Most of the variation of the fluxes with latitude is found in the higher wavenumber intervals for both clear and cloudy skies. The main features of the wavenumber integrated cooling rates are explained with reference to calculations in more restricted wavenumber intervals. A tropical lower tropospheric cooling maximum is produced by water vapor continuum effects in the 760-1240 per cm window. A secondary upper tropospheric cooling maximum, with wide meridional extent, is produced by water vapor rotational lines between 30-430 per cm. Water vapor lines throughout the terrestrial infrared spectrum prevent the upflux maximum from coinciding with the surface temperature maximum.

Charlock, T. P.↗

Wet/Dry Vacuum Cleaner

Vacuum cleaner collects and retains dust, wet debris, and liquids. Designed for housekeeping on Space Station Freedom, it functions equally well in normal Earth Gravity or in microgravity. Generates acoustic noise at comfortably low levels and includes circuitry that reduces electromagnetic interference to other electronic equipment. Draws materials into bag made of hydrophobic sheet with layers of hydrophilic super-absorbing pads at downstream end material. Hydrophilic material can gel many times its own weight of liquid. Blower also provides secondary airflow to cool its electronic components.

Reimers, Harold↗

A 1D Model for Nucleation of Ice From Aerosol Particles: An Application to a Mixed-Phase Arctic Stratus Cloud Layer

Mixed-phase clouds (MPCs) have been identified as significant contributors to uncertainties in climate projections, attributable to model representation of processes controlling the formation and loss of supercooled water droplets and ice particles from the atmosphere. Arctic MPCs are commonly widespread and long-lived, with sustained ice crystal formation processes that challenge current understanding. This study examines the ice-nucleating particle (INP) reservoir dynamics governing immersion-mode heterogeneous freezing in an observed case of Arctic MPCs using a simplified 1D aerosol-cloud model. The model setup includes prescribed dynamical forcings and thermodynamic profiles, and represents INPs as multicomponent and polydisperse particle size distributions. Diagnostic and prognostic approaches to immersion freezing parameterization are compared, including time-independent (singular) number- and surface area-based descriptions and a time-dependent description following classical nucleation theory (CNT). The choice of freezing parameterization defines the size of the INP reservoir. The CNT-based description yields an orders of magnitude larger INP reservoir than the singular parameterizations, which is the dominant factor for sustained ice crystal formation. The efficiency of the freezing process and cloud cooling are of secondary importance. A diagnostic treatment neglecting INP loss is only accurate when the INP reservoir size is large and INP depletion weak. Since a larger INP reservoir sustains ice crystal formation substantially longer, and ice water path scales with ice crystal concentrations for the conditions considered, resolving the source of differences in INP reservoir dynamics due to model implementation is a high priority for advancing climate model physics.

aerosol↗

Study of experiments on condensation of nitrogen by homogeneous nucleation at states modelling those on the national transonic facility

A cryogenic wind tunnel is based on the twofold idea of lowering drive power and increasing Reynolds number by operating with nitrogen near its boiling point. There are two possible types of condensation problems involved in this mode of wind tunnel operation. They concern the expansion from the nozzle supply to the test section at relatively low cooling rates, and secondly the expansion around models in the test section. This secondary expansion involves higher cooling rates and shorter time scales. In addition to these two condensation problems it is not certain what purity of nitrogen can be achieved in a large facility. Therefore, one cannot rule out condensation processes other than those of homogeneous nucleation.

Wegener, P. P.↗

Secondary instability of high-speed flows and the influence of wall cooling and suction

The periodic streamwise modulation of the supersonic and hypersonic boundary layers by a two dimensional first mode or second mode wave makes the resulting base flow susceptible to a broadband spanwise-periodic three dimensional type of instability. The principal parametric resonance of this instability (subharmonic) was analyzed using Floquet theory. The effect of Mach number and the effectiveness of wall cooling or wall suction in controlling the onset, the growth rate, and the vortical nature of the subharmonic secondary instability are assessed for both a first mode and a second mode primary wave. Results indicate that the secondary subharmonic instability of the insulated wall boundary layer is weakened as Mach number increases. Cooling of the wall destabilizes the secondary subharmonic of a second mode primary wave, but stabilizes it when the primary wave is a first mode. Suction stabilizes the secondary subharmonic at all Mach numbers.

El-Hady, Nabil M.↗

Secondary instability of high-speed flows and the influence of wall cooling and suction

The periodic streamwise modulation of the supersonic and hypersonic boundary layers by a two-dimensional first-mode or second-mode wave makes the resulting base flow susceptible to a broadband spanwise-periodic three-dimensional type of instability. The principal parametric resonance of this instability (subharmonic) has been analyzed using Floquet theory. The effect of Mach number and the effectiveness of wall cooling or wall suction in controlling the onset, the growth rate, and the vortical structure of the subharmonic secondary instability are assessed for both a first-mode and a second-mode primary wave. Results indicate that the secondary subharmonic instability of an insulated wall boundary layer is weakened as Mach number increases. Cooling of the wall destabilizes the secondary subharmonic of a second-mode primary wave, but stabilizes it when the primary wave is a first mode. Suction stabilizes the secondary subharmonic at all Mach numbers.

El-Hady, Nabil M.↗

Cryogenic cooling of instruments in orbit - A standard solid cryogen cooler approach

A study has been conducted to determine the utility and characteristics of a solid cryogen cooler which could meet a variety of instrument and mission requirements. The cooler consists essentially of two stages of solid cryogen and two cooled shields. The inner shield is thermally grounded to the secondary (warmer) cryogen and provides a low temperature boundary around the colder primary stage, while the outer shield reduces the heat loads upon the secondary cryogen. The baseline design provides cooling of approximately 1 watt over the temperature range 60-100 K, 0.5 watts from 15 to 60 K, and 0.2 watts from 8 to 15 K for a one-year lifetime. For low cooling loads (0.1 W) and with use of an optional cooled shield, cooling lifetimes of 8 years are possible.

Nast, T. C.↗

Secondary instability of high-speed flows and the influence of wall cooling and suction

The periodic streamwise modulation of the supersonic and hypersonic boundary layers by a two-dimensional first-mode or second-mode wave makes the resulting base flow susceptible to a broad-band spanwise-periodic three-dimensional type of instability. The principal parametric resonance of this instability (subharmonic) has been analyzed using Floquet theory. The effect of Mach number and the effectiveness of wall cooling or wall suction in controlling the onset, the growth rate, and the vortical structure of the subharmonic secondary instability are assessed for both a first-mode and a second-mode primary wave.

El-Hady, Nabil M.↗

Combustion Stability Characteristics of the Project Morpheus Liquid Oxygen/Liquid Methane Main Engine

The Project Morpheus liquid oxygen (LOX) / liquid methane rocket engines demonstrated acousticcoupled combustion instabilities during sea‐level ground‐based testing at the NASA Johnson Space Center (JSC) and Stennis Space Center (SSC). High‐amplitude, 1T, 1R, 1T1R (and higher order) modes appear to be triggered by injector conditions. The instability occurred during the Morpheus‐specific engine ignition/start sequence, and did demonstrate the capability to propagate into mainstage. However, the instability was never observed to initiate during mainstage, even at low power levels. The Morpheus main engine is a JSC‐designed ~5,000 lbf‐thrust, 4:1 throttling, pressure‐fed cryogenic engine using an impinging element injector design. Two different engine designs, named HD4 and HD5, and two different builds of the HD4 engine all demonstrated similar instability characteristics. Through the analysis of more than 200 hot fire tests on the Morpheus vehicle and SSC test stand, a relationship between ignition stability and injector/chamber pressure was developed. The instability has the distinct characteristic of initiating at high relative injection pressure drop (dP) at low chamber pressure (Pc); i.e., instabilities initiated at high dP/Pc at low Pc during the start sequence. The high dP/Pc during start results during the injector /chamber chill‐in, and is enhanced by hydraulic flip in the injector orifice elements. Because of the fixed mixture ratio of the existing engine design (the main valves share a common actuator), it is not currently possible to determine if LOX or methane injector dP/Pc were individual contributors (i.e., LOX and methane dP/Pc typically trend in the same direction within a given test). The instability demonstrated initiation characteristic of starting at or shortly after methane injector chillin. Colder methane (e.g., sub‐cooled) at the injector inlet prior to engine start was much more likely to result in an instability. A secondary effect of LOX sub‐cooling was also possibly observed; greater LOX sub‐ cooling improved stability. Some tests demonstrated a low‐amplitude 1L‐1T instability prior to LOX injector chill‐in. The Morpheus main engine also demonstrated chug instabilities during some engine shutdown sequences on the flight vehicle and SSC test stand. The chug instability was also infrequently observed during the startup sequence. The chug instabilities predictably initiated at low dP/Pc at low Pc. The chug instabilities were always self‐limiting; startup chug instabilities terminated during throttle‐up and shutdown chug instabilities decayed by shutdown termination.

Melcher, J. C.↗