Search NASASearch

SEARCH · Search NASA

Results for “segmented detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector

Measuring the Muon Neutrino Magnetic Moment in the NOvA Near Detector

Measuring an enhanced neutrino magnetic moment would be a clear indication of physics beyond the Standard Model, shedding light on the correct beyond Standard Model theory or the potential Majorana nature of neutrinos. It would manifest in the NOvA near detector as an excess of neutrino-on-electron elastic scattering interactions at low electron recoil energies. Leveraging an intense and highly pure muon neutrino beam, along with a finely segmented liquid scintillator detector technology specifically designed for electromagnetic shower separation, enables NOvA to achieve a potentially world-leading sensitivity in probing the effective muon neutrino magnetic moment. This analysis, based on neutrino data collected between 2014 and 2021, corresponding to an exposure of $13.8\times10^{20}$ protons-on-target, yields a result consistent with the Standard Model-only hypothesis with a p-value of 0.31. An upper limit on the effective muon neutrino magnetic moment is set at $\mu_{\nu_\mu}<19.1\times 10^{-10}\mu_B$ at $90\%$ confidence level. Despite facing statistical limitations stemming from low cross section of the signal process, systematic uncertainties have a significant impact on this result. To address these challenges, the NOvA Test Beam experiment focuses on mitigating some of the largest systematic uncertainties within NOvA by investigating particle interactions and energy deposition in a small-scale replica NOvA detector. This thesis describes the calibration of the NOvA Test Beam detector, which is a crucial step in analysing the Test Beam data before they can be utilised to reduce NOvA systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Single-Volume Scatter Camera (Final Report)

This document serves as a comprehensive final report for the Single-Volume Scatter Camera (SVSC) project. Most of the work over the course of this project has been documented in journal articles, conference papers, and other reports. We therefore reference those materials for detailed presentation of our technical results. The most recent efforts on the project have not been published and are presented in detail here. We present characterizations of two neutron scatter camera prototypes; one using a monolithic geometry, and one using an optically segmented geometry. Both detectors employ plastic scintillator with SiPM-based readout. For the monolithic prototype, we present calibrations of several detector parameters made using a set of dark counts. In particular, we employ a coincidence analysis to characterize the distribution external optical crosstalk, along with the relative timing of the different SiPMs. For the optically segmented prototype we present the results of calibrations made using a tagged 22 Na source, as well as the results of an imaging measurement made using a tagged AmBe source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Prong Segmentation using Point Set Transformers in Multiple View Neutrino Detectors

NOvA is a long-baseline neutrino experiment studying neutrino oscillations by detecting neutrinos from the NuMI beam at Fermilab. Its physics analysis relies on accurate prong segmentation, which involves matching each hit to its source particle and identifying the particle type. This task has commonly been addressed using a combination of traditional clustering algorithms and convolutional neural networks (CNNs). However, NOvA’s detector design presents data as two sparse and decoupled 2D images (XZ and YZ views) rather than a native 3D representation, posing a significant challenge for traditional CNN-based models. In this talk, we propose a novel neural network based on the Point Set Transformer. By treating detector hits as sparse point clouds and implementing a cross-view attention mechanism, our model enables efficient information mixing between both views. Evaluated on NOvA simulated data, our model achieves superior accuracy while requiring significantly fewer computational resources compared to other models. Furthermore, the model demonstrates great performance when applied to Liquid Argon Time Projection Chamber (LArTPC) data, which shows its potential as a universal prong segmentation algorithm for multiple view neutrino detectors.

Liu, Jiaxi [UC, Irvine]

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta (0vββ) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the Laboratori Nazionali del Gran Sasso, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation 0vββ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

Adams, D. Q. [University of South Carolina]

Charged Pion Production Explorations Using the NOvA Near Detector

The~300T NOvA Near Detector (ND) utilizes segmented liquid scintillator to reconstruct interacting neutrinos arriving from the NuMI Beamline at Fermilab. Given NuMI’s intensity and the ND’s relatively short baseline, NOvA has recorded some of the world’s highest statistics for neutrino interactions around ~2GeV, in great similarity to the forthcoming DUNE experiment. This energy regime is replete with resonant interactions, which will form the plurality of final states in DUNE. NOvA seeks to empower the community with measurements of processes for both semi-exclusive and semi-inclusive charged pion production across muon kinematics and pion angle via single-and multidifferential neutrino scattering cross sections. This poster will review current progress across several related analyses, and look forward to future results.

Roy, Palash K. [Wichita State U.] (ORCID:000000022

NOvA in 10 Minutes

NOvA is a long-baseline neutrino oscillation experiment that utilizes the NuMI beamline at Fermilab. The experiment consists of two functionally identical, segmented liquid scintillator detectors. A 300-ton near detector sits at Fermilab, while a 14-kiloton far detector is located 810 km away in Ash River, Minnesota. Both are situated 14.6 mrad off the beam axis to peak the neutrino energy spectrum near the first oscillation maximum. NOvA measures muon neutrino disappearance and electron neutrino appearance in both neutrino and antineutrino beam modes, providing sensitivity to the neutrino mass ordering, the octant of the atmospheric mixing angle \theta_{23}, and the CP-violating phase \delta_{CP}. In this talk, I will give a concise overview of the NOvA experiment and its detectors, followed by highlights from recent oscillation analyses. I will also highlight notable cross-section measurements at the near detector. Finally, I will briefly introduce ongoing analyses beyond the standard three-flavor oscillation framework, including searches for sterile neutrinos and non-standard interactions, as well as exotic signatures such as magnetic monopoles, light dark matter, neutrino magnetic moments, and cosmic-ray muon studies.

Khanam, Aklima [Syracuse U. (main)] (ORCID:0009000

Track Matching in the DUNE Near Detectors

The Deep Underground Neutrino Experiment (DUNE) is an international particle physics experiment looking answer some of the largest unanswered questions in neutrino physics. DUNE uses a high power neutrino beam produced at Fermi National Accelerator Laboratory (Fermilab), and consists of a near detector (ND) also located at Fermilab and a far detector (FD) 1300 km away at the Sanford Underground Research Facility (SURF) in South Dakota. In the first phase of the experiment, the ND complex will contain a modular liquid argon TPC (ND-LAr) and a solid scintillator-based muon spectrometer (TMS), in addition to a beam monitoring detector (SAND) and systems for moving ND-LAr and TMS away from the neutrino beam axis (PRISM). A prototype of ND-LAr, the 2x2 demonstrator, alongside a solid scintillator muon tagger provided by repurposed MINERvA planes, has been built and taken data at Fermilab. For analyses with the ND, connecting particle tracks (such as muons) that exit the liquid argon active volume into the solid scintillator muon detector can improve particle identification and energy reconstruction, and alleviate pileup due to the intense beam. To match tracks between detectors during reconstruction, we have explored using Graph Neural Networks (GNNs) to connect tracks segments between the liquid argon detector region and the solid scintillator detector planes. We have trained a GNN on reconstructed simulated data from the 2×2 demonstrator and repurposed MINERvA planes. We will evaluate its performance and then train a similar network on reconstructed ND-LAr and TMS simulations.

Xing, Daniel [U. Colorado, Boulder]

Detector alignment for X-ray crystallography using Millepede-II

I describe a method for accurately refining the geometrical parameters of segmented X-ray area detectors on the basis of serial crystallography data, using 'Millepede' – an algorithm created for a very similar problem in high-energy physics. The Millepede method for serial crystallography builds on the approach of Brewster et al. [Acta Cryst. (2018), D74, 877–894], in which the detector parameters are refined simultaneously with the parameters for each individual crystal. This accounts for the mutual dependency between the parameters and thereby avoids the bias and slow convergence problems that have afflicted older approaches in which the deviations between observed and calculated Bragg peak positions were taken directly as the updates for the detector panel positions. The Millepede method uses the special structure of the least-squares normal equations to reduce them to a much smaller form that can be solved very quickly, even compared with the sparse matrix methods used previously. This makes it practical to refine the detector geometry frequently and thereby maintain accurate calibration without specialized alignment campaigns. Tilts of detector panels out of the plane can be reliably refined, as can the overall distance of the detector in the beam direction. With a simulated test case, the new method produced panel shifts within 7% of the correct values with only one iteration, and produced almost exactly correct shifts after a second iteration. A simulated out-of-plane panel rotation was correctly determined to within 0.001°. Applied to experimental data from an X-ray free-electron laser, the method increased the indexable fraction of frames from 30% to 91% in a single iteration, and to 96% after two further iterations. Computing the geometry updates on the basis of 2060 crystals took only 0.819 s on desktop computing hardware, including the time taken to read the required data from disk. The scaling was found to be very close to linear for up to 100 980 sets of crystal parameters, which took only 78.2 s to process under the same conditions. The method has been applied as part of a real-time feedback system at a synchrotron radiation beamline, in which an out-of-plane detector tilt of 0.04° was detected and corrected. Possible further applications are also described here.

Millepede-II

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid is a neutrino experiment at very-short baselinesearching for active-to-sterile oscillations of reactorantineutrinos. The detection principle is based on the pairing oftwo types of solid scintillators: polyvinyl toluene and $^{6}$Li:ZnS(Ag), which is a new technology used in this field ofPhysics. In addition to good neutron-gamma discrimination, thissetup allows the detector to be highly segmented; the basicdetection unit is a 5 cm cube. High segmentation provides numerousadvantages including precise localisation of the Inverse Beta Decay(IBD) products, the derivation of an antineutrino energy estimatorbased on the isolated positron energy, and a powerful backgroundreduction tool that relies on the topological signature of thesignal. Finally, the system is read out by a network ofwavelength-shifting fibres coupled to photosensors. A relativeelectromagnetic calibration is performed with horizontal cosmicmuons. This source poses the simplest calibration problem in which asingle detection unit is involved. In addition, large muon energydeposits allow us to perform a calibration at the most detailedlevel (i.e. per fibre) and to accurately define the fraction ofenergy escaping to neighbouring detection cells. A statisticalprecision at the sub-percent level is reached. The paper alsodiscusses two methods to calibrate the absolute energy scale andpresents their implementation and results. The first method relieson horizontal muons, though the precision is limited to around 10%because of the uncertainty in the energy distribution of suchmuons. A novel, alternative method based on the radioactiveamericium-beryllium source is proposed. It takes advantage of theelectron-positron pair-production process and provides a calibrationpoint at 3.4 MeV (i.e. in the core of the IBD positronspectrum). The paper is concluded with various cross-check includinga determination of the energy spectrum of the standard cosmogenicbackground candle: $^{12}$B.

Abreu, Y. [Antwerp U.]

Road to PROSPECT-II

The Precision Reactor Oscillation and SPECTrum (PROSPECT) experiment is based in a segmented liquid scintillator antineutrino detector situated approximately 7 meters from the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Its main goal is to investigate short-baseline antineutrino oscillations. The first phase of data collection, known as PROSPECT-I, was held from 2018 to 2019 and was used for several high-precision analyses, including multiple measurements of the $^{235}U$ antineutrino spectrum and searches for $eV$-scale sterile antineutrino oscillations. The collaboration is now preparing for the second phase, PROSPECT-II, which features an upgraded detector design. This advancement will enhance sensitivity and statistical power, allowing for a broader range of analyses beyond those achieved in PROSPECT-I. As we transition into this new phase, new questions have arisen concerning background simulation and its potential differences from those conducted during the initial phase of the experiment. Moreover, it is essential to ascertain, through simulations, the positive effects that an improved detector could have on the study of oscillations. This information is crucial for justifying the proposed enhancements, and I will cover all of this in the talk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

FNCL Enhancements Implementation (FY25 Annual Report)

The FNCL investigations team at Lawrence Livermore National Laboratory (LLNL) has completed research and development of hardware, signal processing, and analysis tools to enhance the measurement capabilities of both the current CAEN SyS VeryFuel Fast Neutron Collar (FNCL) instrument and a next-generation FNCL prototype. The team successfully built and commissioned the LLNL Demonstrator System: a fully integrated, three-panel detector system featuring higher segmentation, plastic scintillators (EJ-276D), Silicon Photomultipliers (SiPMs), no high-voltage requirement, a reduced electronic footprint, and the LLNL-developed Gaussian Mixture Model Pulse Shape Discrimination (GMM-PSD) signal processing. An extensive experimental campaign was conducted at LLNL’s Inherently Safe Subcritical Assembly (ISSA) facility using both the baseline FNCL and the LLNL Demonstrator. The campaign results validated system performance, calibration stability, and the effectiveness of advanced signal processing and analysis algorithms in a relevant environment.

and physical protection

Road to PROSPECT-II

The Precision Reactor Oscillation and SPECTrum (PROSPECT) experiment is based in a segmented liquid scintillator antineutrino detector situated approximately 7 meters from the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Its main goal is to investigate short-baseline antineutrino oscillations. The first phase of data collection, known as PROSPECT-I, was held from 2018 to 2019 and was used for several high-precision analyses, including multiple measurements of the $^{235}U$ antineutrino spectrum and searches for $eV$-scale sterile antineutrino oscillations. The collaboration is now preparing for the second phase, PROSPECT-II, which features an upgraded detector design. This advancement will enhance sensitivity and statistical power, allowing for a broader range of analyses beyond those achieved in PROSPECT-I. As we transition into this new phase, new questions have arisen concerning background simulation and its potential differences from those conducted during the initial phase of the experiment. Moreover, it is essential to ascertain, through simulations, the positive effects that an improved detector could have on the study of oscillations. This information is crucial for justifying the proposed enhancements, and I will cover all of this in the talk.

43 PARTICLE ACCELERATORS

Algorithm to extract direction in 2D discrete distributions and a continuous Frobenius norm

In this study, we present a novel algorithm for determining directionality in 2D distributions of discrete data. We compare a reference dataset with a known direction to a measured dataset with an unknown direction by the Frobenius norm of the difference (FND) to find the unknown direction. To generalize this concept, we develop a continuous Frobenius norm of the difference (CFND) as a continuous analog of the FND and derive its analytical expression. By relating fitted and normalized 2D Gaussian distributions, we show that the CFND approximates the FND, and we validate this relationship with computer simulations. We find that a first-order approximation of the CFND between two similar Gaussian distributions takes the form of an absolute sine function, offering a simple analytical form with potential applications in specialized areas such as segmented inverse beta decay neutrino detectors, astronomy, machine learning, and more. Our methodology consists of modeling a 2D Gaussian distribution, binning the data into a histogram, and encoding it as a square matrix. Rotating this matrix around its geometric center and comparing it to a measured dataset using the FND gives us rotational data that we fit with an absolute sine function. The location of the minimum of this fit is the angle closest to the true angle of the direction in the measured dataset. We present the derivation and discuss initial applications of the CFND in our novel algorithm, demonstrating its success in approximating directionality in 2D distributions.

Physics

Statistical Performance of Forced Oscillation Detectors in the Presence of Missing Measurements

In bulk power systems, measurement-based monitoring for large oscillations can help maintain system reliability. One of the challenges encountered in a recent field demonstration was the unavailability of measurements due to underlying measurement quality or communication problems. During the demonstration, the oscillation detector ignored a measurement location if even 10 seconds of data was missing. To extend the detector's ability to operate in these conditions, this paper evaluates the impact of three methods for addressing missing data. The strengths and weaknesses of each approach are evaluated using theoretical expressions for the probability of detection along with results from simulated data and publicly available field measurements. Based on these results, a suitable approach is identified that can extend the oscillation detector's performance when large segments of data are missing.

Follum, James D.

Toward an AI-Powered Software Pipeline for Real-Time Tracking and Analysis of Wildfire and Smoke

Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...

Color segmentation