Search NASA⌕ Search

SEARCH · Search NASA

Results for “semiconductor device measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization of Noise in CMOS Ring Oscillators at Cryogenic Temperatures

Allan deviation provides a means to characterize the time-dependence of noise in oscillators and potentially identify the source characteristics. Measurements on a 130 nm, 7-stage ring oscillator show that the Allan deviation declines from 300 K to 150 K as expected, but surprisingly increases from 150 K to 11 K. At low temperatures, the measured Allan deviation can be well fit using a few random telegraph noise (RTN) sources over the range of a few kilohertz to a few gigahertz. Further, the RTN characteristics evolve to reveal an enhanced role in low-frequency noise at lower temperatures.

47 OTHER INSTRUMENTATION↗

Evaluation of Fe-βGa 2 O 3 for Photoconductive Semiconductor Switching

We present iron-doped beta gallium oxide (Fe- β Ga2O3) as a candidate for photoconductive semiconductor switches (PCSSs) with sub-bandgap light. From a commercially available Fe- β Ga2O3 wafer, we first did material characterization. This included measurements of absorption coefficient and dopant composition, carrier activation energy up to 200 °C, break down field of planar electrodes (limited from material passivation), and free carrier recombination lifetime, and thermal effects up to 203 °C on photocurrent with a 447 nm light emitting diode (LED) source. Here, we then demonstrated pulsed operation of a Fe- β Ga2O3 PCSS under different sub-bandgap wavelengths (355, 532, and 1064 nm) and sub-ns pulses. Fe- β Ga2O3 is a candidate for high temperature PCSS with 355 nm responsivity of 7×10 -7 A-cm/W-kV at room temperature and up to 5.5×10 -4 A-cm/W-kV at 200 °C. From these investigations, we discuss a simple trap model to describe the illumination process of the PCSS. Fe- β Ga2O3 has a high breakdown field and has moderate responsivity characteristics, but the dark current at high temperature leads to low photo-to-dark current ratio (PDCR). Regardless, we verify its potential as a PCSS material for harsh environment applications.

42 ENGINEERING↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

Field Funneling and Range Straggling in Silicon Detectors

Magnitudes of field funneling and range straggling determined in silicon-surface-barrier (Schottky-barrier) charged-particle detectors (SSBD's) through meaurement of charges collected from alpha-particle tracks. Method used extended to straightforward measurement of charge collection from heavy-ion tracks in these and other semiconductor devices. Such measurements used to assess single-event upsets in integratedcircuit chips, with view toward making them resistant to radiation. Field funneling and range straggling measured with electronic system in which charge collected from individual ions measured and recorded by multichannel analyzer.

Zoutendyk, J. A.↗

Test Standard Revision Update: JESD57, "Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation"

The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. In this talk, we place this test standard into context with other relevant radiation test standards to show its importance for single-event effect radiation testing for space applications. We show the range of industry, government, and end-user party involvement in the revision. Finally, we highlight some of the key changes being made and discuss the trade-space in which setting standards must be made to be both useful and broadly adopted.

heavy ion↗

Methods of measurement for semiconductor materials, process control, and devices

Significant accomplishments include development of a procedure to correct for the substantial differences of transistor delay time as measured with different instruments or with the same instrument at different frequencies; association of infrared response spectra of poor quality germanium gamma ray detectors with spectra of detectors fabricated from portions of a good crystal that had been degraded in known ways; and confirmation of the excellent quality and cosmetic appearance of ultrasonic bonds made with aluminum ribbon wire. Work is continuing on measurement of resistivity of semiconductor crystals; study of gold-doped silicon, development of the infrared response technique; evaluation of wire bonds and die attachment; and measurement of thermal properties of semiconductor devices, delay time and related carrier transport properties in junction devices, and noise properties of microwave diodes.

Bullis, W. M.↗

Microwave Microscopy and Its Applications

Understanding the nanoscale electrodynamic properties of a material at microwave frequencies is of great interest for materials science, condensed matter physics, device engineering, and biology. With specialized probes, sensitive detection electronics, and improved scanning platforms, microwave microscopy has become an important tool for cutting-edge materials research in the past decade. In this article, we review the basic components and data interpretation of microwave imaging and its broad range of applications. In addition to the general-purpose mapping of permittivity and conductivity, microwave microscopy is now exploited to perform quantitative measurements on semiconductor devices, photosensitive materials, ferroelectric domains and domain walls, and acoustic-wave systems. Implementation of the technique in low-temperature and high-magnetic-field chambers has also led to major discoveries in quantum materials with strong correlation and topological order. We conclude the review with an outlook of the ultimate resolution, operation frequency, and future industrial and academic applications of near-field microwave microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-Situ Characterization Tools for Evaluating Radiation Tolerance and Elemental Migration in Perovskites

This paper discusses the in-situ characterization tools designed to assess radiation tolerance and elemental migration in perovskite materials. With the increasing use of perovskites in various technological applications, understanding their response to radiation exposure is paramount. Ion Beam Induced Charge (IBIC) emerges as a powerful tool for investigating the radiation tolerance of perovskites at the microscale. By employing focused ion beams, IBIC allows for the spatial mapping of charge carriers, offering insights into the material's electronic response to radiation-induced defects. This technique enables researchers to pinpoint areas of enhanced or suppressed charge collection, providing valuable information on the perovskite's intrinsic properties under irradiation. Rutherford Backscattering Spectrometry (RBS) complements the study by offering a quantitative analysis of elemental migration in perovskite materials. Through the precise measurement of backscattered ions, RBS provides a detailed understanding of the elemental composition and distribution within the perovskite lattice after radiation exposure. The integration of IBIC and RBS techniques in in-situ experiments enhances the comprehensive characterization of radiation effects on perovskites.

ion beams↗

Composition Quantification of SiGeSn Alloys Through Time-of-Flight Secondary Ion Mass Spectrometry: Calibration Methodologies and Validation With Atom Probe Tomography

Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a powerful technique for elemental compositional analysis and depth profiling of materials. However, it encounters the problem of matrix effects that hinder its application. In this work, we introduce a pioneering ToF-SIMS calibration method tailored for SixGeySnz ternary alloys. SixGe1-x and Ge1-zSnz binary alloys with known compositions are used as calibration reference samples. Through a systematic SIMS quantification study of SiGe and GeSn binary alloys, we unveil a linear correlation between secondary ion intensity ratio and composition ratio for both SiGe and GeSn binary alloys, effectively mitigating the matrix effects. Extracted relative sensitivity factor (RSF) value from SixGe1-x (0.07 < x < 0.83) and Ge1-zSnz (0.066 < z < 0.183) binary alloys are subsequently applied to those of SixGeySnz (0.011 < x < 0.113, 0.863 < y < 0.935 and 0.023 < z < 0.103) ternary alloys for elemental compositions quantification. These values are cross-checked by Atom Probe Tomography (APT) analysis, an indication of the great accuracy and reliability of as-developed ToF-SIMS calibration process. Furthermore, the proposed method and its reference sample selection strategy in this work provide a low-cost as well as simple-to-follow calibration route for SiGeSn composition analysis, thus driving the development of next-generation multifunctional SiGeSn-related semiconductor devices.

36 MATERIALS SCIENCE↗

Silicon device performance measurements to support temperature range enhancement

Semiconductor power devices are typically rated for operation below 150 C. Little data is known for power semiconductors over 150 C. In most cases, the device is derated to zero operating power at 175 C. At the high temperature end of the temperature range, the intrinsic carrier concentration increases to equal the doping concentration level and the silicon behaves as an intrinsic semiconductor. The increase in intrinsic carrier concentration results in a shift of the Fermi level toward mid-bandgap at elevated temperatures. This produces a shift in devices characteristics as a function of temperature. By increasing the doping concentration higher operating temperatures can be achieved. This technique was used to fabricate low power analog and digital devices in silicon with junction operating temperatures in excess of 300 C. Additional temperature effects include increased p-n junction leakage with increasing temperature, resulting in increased resistivity. The temperature dependency of physical properties results in variations in device characteristics. These must be quantified and understood in order to develop extended temperature range operation.

Bromstead, James↗

Ionizing Radiation Sensing with Functionalized and Copper-Coated SWCNT/PMMA Thin Film Nanocomposites

This paper studies the ionizing radiation effects on functionalized single-walled carbon nanotube (SWCNT)/poly(methyl methacrylate) (PMMA) thin-film nanocomposites [SWNT/PMMA]. The functionalized thin-film devices are made of ferrocene-doped SWCNTs, SWCNTs functionalized with carboxylic acid (COOH), and SWCNTs coated/ modified with copper. The nanocomposite was synthesized by the solution blending method and the resulting nanocomposite was spin-cast on interdigitated electrodes (IDEs). A 160 kV X-ray source was used to irradiate the thin film and changes in the electrical resistance of the nanocomposites due to X-rays were measured using a semiconductor device analyzer. Carboxylic acid functionalized and copper-coated SWCNT/PMMA nanocomposite showed a reduced response to X-rays compared to unfunctionalized SWCNT/PMMA nanocomposite. Ferrocene-doped SWCNT showed a higher sensitivity to X-rays at lower dose rates. This is in contrast to a previous study that showed that similar nanocomposites using functionalized multi-walled CNTs (MWCNTs) had demonstrated an improved response to X-rays ionizing radiation compared to unfunctionalized MWCNTs for all dose rates. Electrical measurements were also performed using the Arduino Nano microcontroller. The result showed that a relatively economical, lightweight-designed prototype radiation sensor based on SWCNT/PMMA thin-film devices could be produced by interfacing the devices with a modest microcontroller. This work also shows that by encapsulating the SWCNT/PMMA thin-film device in a plastic container, the effect of ambient humidity can be reduced and the device can still be used to detect X-ray radiation. This study further shows that the sensitivity of SWCNT to X-rays was dependent on both the functionalization of the SWCNT and the dose rate.

36 MATERIALS SCIENCE↗

Superconducting-Cavity Accelerometer

Resonant frequency of microwave superconducting cavity sensitive to gravitation and acceleration. Sensitive accelerometer assembled by combining superconducting microwave cavity and conventional microwave semiconductor oscillator circuit. Device measures acelerations as small as 10-10 cm/S2 (10-13 g's). Also configured to measure small gradients in gravitational field of Earth.

Reinhardt, V. S.↗

Equipment for On-Wafer Testing From 220 to 325 GHz

A system of electronic instrumentation, constituting the equivalent of a two-port vector network analyzer, has been developed for use in on-wafer measurement of key electrical characteristics of semiconductor devices at frequencies from 220 to 325 GHz. A prior system designed according to similar principles was reported in Equipment for On-Wafer Testing at Frequencies Up to 220 GHz (NPO-20760), NASA Tech Briefs, Vol. 25, No. 11 (November 2001), page 42. As one would expect, a major source of difficulty in progressing to the present higher-frequency-range system was the need for greater mechanical precision as wavelengths shorten into the millimeter range, approaching the scale of mechanical tolerances of prior systems. The system (see figure) includes both commercial off-the-shelf and custom equipment. As in the system of the cited prior article, the equipment includes test sets that are extended versions of commercial network analyzers that function in a lower frequency range. The extension to the higher frequency range is accomplished by use of custom frequency-extension modules that contain frequency multipliers and harmonic mixers. On-wafer measurement is made possible by waveguide wafer probes that were custom designed and built for this wavelength range, plus an on-wafer calibration substrate designed for use with these probes. In this case, the calibration substrate was specially fabricated by laser milling. The system was used to make the first on-wafer measurements of a semiconductor device in the frequency range from 220 to 320 GHz. Some of the measurement results showed that the device had gain.

Samoska, Lorene↗