Search NASA⌕ Search

SEARCH · Search NASA

Results for “separation techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Instrumental and analytic techniques for separating protons from electrons in the cosmic ray flux

Techniques are being investigated to aid in distinguishing between electrons and the large background of interacting protons which simulate electron-induced electromagnetic cascades. For cosmic ray primaries, incident on the HECRE ionization spectrometer, statistical criteria are employed to test the cascade curves with the incident energy and starting point as free parameters. The physical significance of the distribution of apparent cascade starting points is being studied using Monte Carlo 100-GeV protons. The proposed use of a CsI detector module (totally-active and high Z) to further discriminate against protons is described.

Crannell, C. J.↗

Modeling of Convective-Stratiform Precipitation Processes: Sensitivity to Partitioning Methods

Six different convective-stratiform separation techniques, including a new technique that utilizes the ratio of vertical and terminal velocities, are compared and evaluated using two-dimensional numerical simulations of a tropical [Tropical Ocean Global Atmosphere Coupled Ocean Atmosphere Response Experiment (TOGA COARE)] and midlatitude continental [Preliminary Regional Experiment for STORM-Central (PRESTORM)] squall line. Comparisons are made in terms of rainfall, cloud coverage, mass fluxes, apparent heating and moistening, mean hydrometeor profiles, CFADs (Contoured Frequency with Altitude Diagrams), microphysics, and latent heating retrieval. Overall, it was found that the different separation techniques produced results that qualitatively agreed. However, the quantitative differences were significant. Observational comparisons were unable to conclusively evaluate the performance of the techniques. Latent heating retrieval was shown to be sensitive to the use of separation technique mainly due to the stratiform region for methods that found very little stratiform rain.

Lang, S. E.↗

Enhanced protein electrophoresis technique for separating human skeletal muscle myosin heavy chain isoforms

Talmadge and Roy (J. Appl. Physiol. 1993, 75, 2337-2340) previously established a sodium dodecyl sulfate - polyacrylamide gel electrophoresis (SDS-PAGE) protocol for separating all four rat skeletal muscle myosin heavy chain (MHC) isoforms (MHC I, IIa, IIx, IIb); however, when applied to human muscle, the type II MHC isoforms (Ila, IIx) are not clearly distinguished. In this brief paper we describe a modification of the SDS-PAGE protocol which yields distinct and consistent separation of all three adult human MHC isoforms (MHC I, IIa, IIx) in a minigel system. MHC specificity of each band was confirmed by Western blot using three monoclonal IgG antibodies (mAbs) immunoreactive against MHCI (mAb MHCs, Novacastra Laboratories), MHCI+IIa (mAb BF-35), and MHCIIa+IIx (mAb SC-71). Results provide a valuable SDS-PAGE minigel technique for separating MHC isoforms in human muscle without the difficult task of casting gradient gels.

NASA Center JSC↗

Modeling of Convective-Stratiform Precipitation Processes: Sensitivity to Partitioning Methods and Numerical Advection Schemes

Six different convective-stratiform separation techniques, including a new technique that utilizes the ratio of vertical and terminal velocities, are compared and evaluated using two-dimensional numerical simulations of a tropical [Tropical Ocean Global Atmosphere Coupled Ocean-Atmosphere Response Experiment (TOGA COARE)] and midlatitude continental [Preliminary Regional Experiment for STORM-Central (PRESTORM)] squall line. The simulations are made using two different numerical advection schemes: 4th order and positive definite advection. Comparisons are made in terms of rainfall, cloud coverage, mass fluxes, apparent heating and moistening, mean hydrometeor profiles, CFADs (Contoured Frequency with Altitude Diagrams), microphysics, and latent heating retrieval. Overall, it was found that the different separation techniques produced results that qualitatively agreed. However, the quantitative differences were significant. Observational comparisons were unable to conclusively evaluate the performance of the techniques. Latent heating retrieval was shown to be sensitive to the use of separation technique mainly due to the stratiform region for methods that found very little stratiform rain. The midlatitude PRESTORM simulation was found to be nearly invariant with respect to advection type for most quantities while for TOGA COARE fourth order advection produced numerous shallow convective cores and positive definite advection fewer cells that were both broader and deeper penetrating above the freezing level.

Lang, Steve↗

Development of a Technique for Separating Raman Scattering Signals from Background Emission with Single-Shot Measurement Potential

A novel technique for extracting Q-branch Raman signals scattered by a diatomic species from the emission spectrum resulting from the irradiation of combustion products using a broadband excimer laser has been developed. This technique is based on the polarization characteristics of vibrational Raman scattering and can be used for both single-shot Raman extraction and time-averaged data collection. The Q-branch Raman signal has a unique set of polarization characteristics which depend on the direction of the scattering while fluorescence signals are unpolarized. For the present work, a calcite crystal is used to separate the horizonal component of a collected signal from the vertical component. The two components are then sent through a UV spectrometer and imaged onto an intensified CCD camera separately. The vertical component contains both the Raman signal and the interfering fluorescence signal. The horizontal component contains the fluorescence signal and a very weak component of the Raman signal; hence, the Raman scatter can be extracted by taking the difference between the two signals. The separation of the Raman scatter from interfering fluorescence signals is critically important to the interpretation of the Raman for cases in which a broadband ultraviolet (UV) laser is used as an excitation source in a hydrogen-oxygen flame and in all hydrocarbon flames. The present work provides a demonstration of the separation of the Raman scatter from the fluorescence background in real time.

Hartfield, Roy J., Jr.↗

Binary Oscillatory Crossflow Electrophoresis

Electrophoresis has long been recognized as an effective analytic technique for the separation of proteins and other charged species, however attempts at scaling up to accommodate commercial volumes have met with limited success. In this report we describe a novel electrophoretic separation technique - Binary Oscillatory Crossflow Electrophoresis (BOCE). Numerical simulations indicate that the technique has the potential for preparative scale throughputs with high resolution, while simultaneously avoiding many problems common to conventional electrophoresis. The technique utilizes the interaction of an oscillatory electric field and a transverse oscillatory shear flow to create an active binary filter for the separation of charged protein species. An oscillatory electric field is applied across the narrow gap of a rectangular channel inducing a periodic motion of charged protein species. The amplitude of this motion depends on the dimensionless electrophoretic mobility, alpha = E(sub o)mu/(omega)d, where E(sub o) is the amplitude of the electric field oscillations, mu is the dimensional mobility, omega is the angular frequency of oscillation and d is the channel gap width. An oscillatory shear flow is induced along the length of the channel resulting in the separation of species with different mobilities. We present a model that predicts the oscillatory behavior of charged species and allows estimation of both the magnitude of the induced convective velocity and the effective diffusivity as a function of a in infinitely long channels. Numerical results indicate that in addition to the mobility dependence, the steady state behavior of solute species may be strongly affected by oscillating fluid into and out of the active electric field region at the ends of the cell. The effect is most pronounced using time dependent shear flows of the same frequency (cos((omega)t)) flow mode) as the electric field oscillations. Under such conditions, experiments indicate that solute is drawn into the cell from reservoirs at both ends of the cell leading to a large mass build up. As a consequence, any initially induced mass flux will vanish after short times. This effect was not captured by the infinite channel model and hence numerical and experimental results deviated significantly. The revised model including finite cell lengths and reservoir volumes allowed quantitative predictions of the time history of the concentration profile throughout the system. This latter model accurately describes the fluxes observed for both oscillatory flow modes in experiments using single protein species. Based on the results obtained from research funded under NASA grant NAG-8-1080.S, we conclude that binary separations are not possible using purely oscillatory flow modes because of end effects associated with the cos((omega)t) mode. Our research shows, however, that a combination of cos(2(omega)t) and steady flow should lead to efficient separation free of end effects. This possibility is currently under investigation.

Molloy, Richard F.↗

Ion-Exclusion Chromatography for Analyzing Organics in Water

A liquid-chromatography technique has been developed for use in the quantitative analysis of urea (and of other nonvolatile organic compounds typically found with urea) dissolved in water. The technique involves the use of a column that contains an ion-exclusion resin; heretofore, this column has been sold for use in analyzing monosaccharides and food softeners, but not for analyzing water supplies. The prior technique commonly used to analyze water for urea content has been one of high-performance liquid chromatography (HPLC), with reliance on hydrophobic interactions between analytes in a water sample and long-chain alkyl groups bonded to an HPLC column. The prior technique has proven inadequate because of a strong tendency toward co-elution of urea with other compounds. Co-elution often causes the urea and other compounds to be crowded into a narrow region of the chromatogram (see left part of figure), thereby giving rise to low chromatographic resolution and misidentification of compounds. It is possible to quantitate urea or another analyte via ultraviolet- and visible-light absorbance measurements, but in order to perform such measurements, it is necessary to dilute the sample, causing a significant loss of sensitivity. The ion-exclusion resin used in the improved technique is sulfonated polystyrene in the calcium form. Whereas the alkyl-chain column used in the prior technique separates compounds on the basis of polarity only, the ion-exclusion-resin column used in the improved technique separates compounds on the basis of both molecular size and electric charge. As a result, the degree of separation is increased: instead of being crowded together into a single chromatographic peak only about 1 to 2 minutes wide as in the prior technique, the chromatographic peaks of different compounds are now separated from each other and spread out over a range about 33 minutes wide (see right part of figure), and the urea peak can readily be distinguished from the other peaks. Although the analysis takes more time in the improved technique, this disadvantage is offset by two important advantages: Sensitivity is increased. The minimum concentration of urea that can be measured is reduced (to between 1/5 and 1/3 of that of the prior technique) because it is not necessary to dilute the sample. The separation of peaks facilitates the identification and quantitation of the various compounds. The resolution of the compounds other than urea makes it possible to identify those compounds by use of mass spectrometry.

Sauer, Richard↗

Development of a Technique for Separating Raman Scattering Signals from Background Emission with Single-Shot Measurement Potential

Raman scattering is a powerful technique for quantitatively probing high temperature and high speed flows. However, this technique has typically been limited to clean hydrogen flames because of the broadband fluorescence interference which occurs in hydrocarbon flames. Fluorescence can also interfere with the Raman signal in clean hydrogen flames when broadband UV lasers are used as the scattering source. A solution to this problem has been demonstrated. The solution to the fluorescence interference lies in the fact that the vibrational Q-branch Raman signal is highly polarized for 90 deg. signal collection and the fluorescence background is essentially unpolarized. Two basic schemes are available for separating the Raman from the background. One scheme involves using a polarized laser and collecting a signal with both horizontal and vertical laser polarizations separately. The signal with the vertical polarization will contain both the Raman and the fluorescence while the signal with the horizontal polarization will contain only the fluorescence. The second scheme involves polarization discrimination on the collection side of the optical setup. For vertical laser polarization, the scattered Q-branch Raman signal will be vertically polarized; hence the two polarizations can be collected separately and the difference between the two is the Raman signal. This approach has been used for the work found herein and has the advantage of allowing the data to be collected from the same laser shot(s). This makes it possible to collect quantitative Raman data with single shot resolution in conditions where interference cannot otherwise be eliminated.

Hartfield, Roy↗

Computational Methods for Dynamic Stability and Control Derivatives

Force and moment measurements from an F-16XL during forced pitch oscillation tests result in dynamic stability derivatives, which are measured in combinations. Initial computational simulations of the motions and combined derivatives are attempted via a low-order, time-dependent panel method computational fluid dynamics code. The code dynamics are shown to be highly questionable for this application and the chosen configuration. However, three methods to computationally separate such combined dynamic stability derivatives are proposed. One of the separation techniques is demonstrated on the measured forced pitch oscillation data. Extensions of the separation techniques to yawing and rolling motions are discussed. In addition, the possibility of considering the angles of attack and sideslip state vector elements as distributed quantities, rather than point quantities, is introduced.

Green, Lawrence L.↗

Computational Methods for Dynamic Stability and Control Derivatives

Force and moment measurements from an F-16XL during forced pitch oscillation tests result in dynamic stability derivatives, which are measured in combinations. Initial computational simulations of the motions and combined derivatives are attempted via a low-order, time-dependent panel method computational fluid dynamics code. The code dynamics are shown to be highly questionable for this application and the chosen configuration. However, three methods to computationally separate such combined dynamic stability derivatives are proposed. One of the separation techniques is demonstrated on the measured forced pitch oscillation data. Extensions of the separation techniques to yawing and rolling motions are discussed. In addition, the possibility of considering the angles of attack and sideslip state vector elements as distributed quantities, rather than point quantities, is introduced.

Green, Lawrence L.↗

A new boundary-layer interaction techniques for separated flows

A new viscous-inviscid interation procedure is presented which is applicable to separated flows. The new procedure is simple, converges rapidly, and does not require numerical smoothing and underrelaxation at least in the cases computer thus far. Calculations are presented for the low-speed separated flow in the juncture region between an axisymmetric body and ting. The viscous computation is done with an inverse boundary-layer procedure which was previously developed. The inviscid computation is made with an axisymmetric transonic code called RAXBOD. The main advantage of the new interaction procedure is that it combines an inverse boundary-layer technique, which is applicable to separated flows, with an existing inviscid analysis code with only a slight boundary condition change required in the inviscid code.

Carter, J. E.↗

Electrophoretic separator for purifying biologicals

This technique separates a single narrow zone of sample mixture in an electrolyte medium into many zones containing a single component of the mixture and electrolyte between them. Since the densities of the separated zones generally differ from that of the intervening medium, such systems are gravitationally unstable and stabilization is required. The various techniques for stabilization include using the capillary space provided by thin films, the interstices of solid material such as filter paper and a variety of gel-forming substances.

Source record↗

A new boundary-layer inviscid iteration technique for separated flow

A new viscous-inviscid iteration procedure is presented which is applicable to separated flows. The new procedure is simple, converges rapidly, and does not require numerical smoothing, at least in the cases computed thus far. Calculations are presented for both incompressible and compressible separated flow in the juncture region between an axisymmetric body and sting. The viscous computation is obtained with a recently developed inverse boundary-layer procedure which is no more complicated than a standard direct finite-difference boundary-layer technique. The inviscid computation is made with an axisymmetric transonic code called RAXBOD, in which surface injection is used to represent the viscous effects.

Carter, J. E.↗

Production of oxygen from lunar ilmenite

The following subjects are addressed: (1) the mechanism and kinetics of carbothermal reduction of simulated lunar ilmenite using carbon and, particularly, CO as reducing agents; (2) the determination of the rate-limiting steps; (3) the investigation of the effect of impurities, particularly magnesium; (4) the search for catalysts suitable for enhancement of the rate-limiting step; (5) the comparison of the kinetics of carbothermal reduction with those of hydrogen reduction; (6) the study of the combined use of CO and hydrogen as products of gasification of carbonaceous solids; (7) the development of reduction methods based on the use of waste carbonaceous compounds for the process; (8) the development of a carbothermal reaction path that utilizes gasification of carbonaceous solids to reducing gaseous species (hydrocarbons and carbon monoxide) to facilitate the reduction reaction kinetics and make the process more flexible in using various forms of carbonaceous feeds; (9) the development of advanced gas separation techniques, including the use of high-temperature ceramic membranes; (10) the development of an optimum process flow sheet for carbothermal reduction, and comparison of this process with the hydrogen reduction scheme, as well as a general comparison with other leading oxygen production schemes; and (11) the use of new and advanced material processing and separation techniques.

Zhao, Y.↗

Turbulent flow separation control through passive techniques

Several passive separation control techniques for controlling moderate two-dimensional turbulent flow separation over a backward-facing ramp are studied. Small transverse and swept grooves, passive porous surfaces, large longitudinal grooves, and vortex generators were among the techniques used. It was found that, unlike the transverse and longitudinal grooves of an equivalent size, the 45-deg swept-groove configurations tested tended to enhance separation.

Lin, J. C.↗

Initial Results from the Kwajalein Micrometeorite Collections

Micrometeorites are constantly arriving at the Earth's surface, however, they are quickly diluted by the natural and anthropogenic back-ground dust. The successful collection of micromete-orites requires either the employment of a separation technique (e.g. using magnets to separate metal-bearing micrometeorites from deepsea sediments [e.g. 1,2] and dissolved pre-historic limestones and salts [e.g. 3,4]), or an approach that limits contamination by terrestrial dust (e.g. collecting from ice, snow and well water in polar regions - locations where the terrestrial dust flux is so low that micrometeorites repre-sent the major dust component [e.g. 5-7]). We have recently set up a micrometeorite collection station on Kwajalein Island in the Republic of the Marshall Is-lands in the Pacific Ocean, using high volume air samplers to collect particles directly from the atmosphere. Collecting at this location exploits the considerably reduced anthropogenic background; Kwajalein is >1000 miles from the nearest continent and for much of the year, trade winds blow from the northeast at 15 to 20 knots providing a continuous stream of oceanic aerosol for sampling. By collecting directly from the atmosphere, the terrestrial age of the particles, and hence weathering they experience, is minimal. We therefore anticipate that the Kwajalein col-lection may include particles that are highly susceptible to weathering and either not preserved well or not found at all in other collections. In addition, this collection method allows for particle arrival times to be constrained so that collections can be timed to correlate with celestial events (e.g. meteor showers). Here we describe the collections and their preparation and report on the initial results.

Wozniakiewicz, P. J.↗

Aerodynamic separation and glideback of a Mach 3 staged booster

A study has been conducted of the staging maneuver for a two-stage, vertical-takeoff, launch vehicle and the subsequent glideback of the booster to a launch site runway. The booster and orbiter are both winged, fully reusable, and have liquid rocket main propulsion. for the staging maneuver, which nominally occurs at Mach 3, a flight control system and separation technique were devised which produced successful separations over a wide range of staging angles of attack. A guidance algorithm was developed for the unpowered glide-back of the booster from the completion of the staging maneuver to touchdown on a runway in the vicinity of the launch site. Using this guidance technique, the booster successfully touched down on the runway while being subjected to a wide range of seasonal and perturbed atmospheric conditions with and without wids as well as errors in staging state conditions and errors in predicted aerodynamics.

Naftel, J. C.↗