Search NASA⌕ Search

SEARCH · Search NASA

Results for “separation techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A New Approach to Monitoring Solvent Extraction Processes for the Nuclear Industry

As part of an initiative to steward research, development, and innovation into the nuclear fuel cycle, Idaho National Laboratory is building the Beartooth testbed. Beartooth will include a cascade of centrifugal contactors, glove box lines, solidification, and dissolution equipment to aid in the progression of novel separation techniques and provide hands-on opportunities to early-career separation scientists. Beartooth will incorporate novel monitoring techniques using sensors and machine learning algorithms to inform a process operator of separation conditions. This research is examining monitoring technologies not typically used in nuclear separation processes such as acoustic microphones, accelerometers, infrared cameras, red-green-blue color sensors, among others. These sensors are being examined for their functionality within a separation process and their ability to detect applicable signals. Machine learning methods are being developed to determine their utility in detecting faults and alerting operators of expected and unexpected events. These methods have the potential to impact Safeguards by Design efforts and real-time decision making. This overview will detail preliminary results from acoustic, vibration, and color sensors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proof-of-concept studies of novel protocols for producing highly pure 48 V from a 48 Cr/ 48 V generator

Here, the quest to improve the quality of nuclear data, such as half-lives, transition yields, and reaction cross-sections, is a shared endeavor among various areas of nuclear science. 48 V is a vanadium isotope for which experimental data on neutron reaction cross-sections is needed. However, traditional isotope production techniques cannot produce 48 V with high enough isotopic purity for some of these measurements. “Isotope harvesting” at the Facility for Rare Isotope Beams (FRIB) is a new isotope production technique that could potentially yield 48 V with the necessary purity for such studies. In this case, 48Cr would be collected and allowed to generate 48 V that can be separated from undecayed 48 Cr to yield highly pure 48 V. Thus, any protocol for producing pure 48 V via isotope harvesting would involve utilizing a separation technique that can effectively separate 48 Cr and 48 V. In this study, the radiotracers 51 Cr and 48 V were used to develop possible radiochemical separation methodologies, which can be translated to obtain high purity 48 V via this novel isotope production method. The developed protocols utilize either ion exchange or extraction chromatographic resins. Separations of 51 Cr and 48 V with AG 1-X8 anion exchange resin respectively resulted in recoveries of 95.6(26)% and 96.2(12)% with radionuclidic purities of 92(2)% and 99(1)%. An even more effective Cr and V separation was obtained with an extraction chromatographic resin (TRU resin) and 10 M HNO 3 loading solution. Here, 51 Cr and 48 V respectively had recoveries of 94.1(28)% and 96.2(13)% with high radionuclidic purities (100(2)% and 100(1)%) in small volumes (8.81(8) mL and 5.39(16) mL). This study suggests that, to maximize the yield and isotopic purity of 48 V, the best production protocol would involve utilizing two separations with TRU resin and 10 M HNO 3 to isolate 48 Cr and purify the generated 48 V.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dynamic separation of gases using microsieves

Separation of light weight molecules, such as nitrogen, argon, and oxygen, from heavier compounds can have significant impacts on energy capture, environmental monitoring, or isotopic applications. Large-scale gas separation techniques, like gas centrifugation and membrane mitigation, can be problematic as they impart tremendous energy and induce high mechanical stress onto the instrumentation. Microsieves, also known as micronozzles or microfunnels, are developed to create physical barriers to separate specific isotopes and gases. Separation is achieved using a converging and diverging micronozzle to impose supersonic gas flow around a curved wall, and it has been used for the separation of heavy actinide isotopes in low weight gas as well as separation of low weight gas compositions of nitrogen and argon back in 1900s. However, systematic reviews of this unique technology are lacking. The application of the Laval style nozzle, which has a converging/diverging entrance fundamental to the micronozzle, is included in this review due to its importance in industrial applications in uranium (U) isotope refinement. Using advanced computational fluid dynamic (CFD) simulations, the extent of gas separation can be modelled. Herein, we first examine the literature and survey recent advances on fabrication techniques for creating curved micronozzles, methods and separation principles used to design devices. Furthermore, we then follow with highlights of CFD simulations applied to evaluate the separation effects using microsieves. Finally, identification of the gap and recommendation for future development and applications are suggested for using intrinsic molecular features and fluidic dynamics in formulating separation strategies.

30 Microfluidics↗

Membrane Separations in Biomass Processing

The development of integrated biorefineries and the greater utilization of biomass resources to reduce dependence on fossil fuel-derived products require research emphasis not just on conversion strategies but also on improving separations associated with biorefining. A significant roadblock towards developing biorefineries is the lack of effective separation techniques evidenced by the relative deficiency of literature in this area. Additionally, high conversion yields may only be realized if effective separations generate feedstock of sufficient purity – this makes research into biomass conversion strategies all the more critical. In this review, the challenges associated with biomass separations are discussed, followed by an overview of the most appropriate separation strategies for processing biomass. One of the unit operations most appealing for biorefining, membrane separations (MS), is then considered along with a review of the recent literature utilizing this technique in biomass processing.

09 BIOMASS FUELS↗

Single-hole couplings in GaAs/AlGaAs double dots probed with transport and EDSR spectroscopy

Here, we report a detailed study of the tunnel barriers within a single-hole GaAs/AlGaAs double quantum dot device (DQD). For quantum information applications as well as fundamental studies, careful tuning and reliable measurements of the barriers are important requirements. In order to tune a DQD device adequately into the single-hole electric dipole spin resonance regime, one has to employ a variety of techniques to cover the extended range of tunnel couplings. In this work, we demonstrate four separate techniques, based upon charge sensing, quantum transport, time-resolved pulsing, and electron dipole spin resonance spectroscopy to determine the couplings as a function of relevant gate voltages and magnetic field. Measurements were performed under conditions of both symmetric and asymmetric tunnel couplings to the leads. Good agreement was observed between different techniques when measured under the same conditions. The results indicate that even in this relatively simple circuit, the requirement to tune multiple gates and the consequences of real potential profiles result in non-intuitive dependencies of the couplings as a function of the plunger gate voltage and the magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Production, Purification and Characterization of Radioisotopes (Final Report)

This collaborative proposal between the University of Alabama at Birmingham (UAB, PI Suzanne Lapi), and Los Alamos National Laboratory (LANL, collaborator Michael Fassbender) aims to develop novel techniques for isotope production. This proposal takes advantage of complementary techniques available at the UAB cyclotron facility and LANL isotope production facility (IPF) and involved UAB faculty, postdocs, graduate students and undergraduates as well as LANL scientists and staff. This project involved the development of separation techniques for radioisotope production at UAB, using radiotracer analogues produced using the TR24 cyclotron, which would directly translate to separations of the desired isotopes produced at LANL via neutron spallation. Extended visits to LANL by UAB students involved in this initiative were originally envision but were hampered due to COVID restrictions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

From ash to oxides: Recovery of rare-earth elements as a step towards valorization of coal fly ash waste

Coal fly ash (CFA) is both a valuable waste material and a potential source of environmental contamination. The inclusion of metals such as rare-earth elements offer a possible incentive towards waste valorization if the metals can be extracted and recovered in an economical manner. Rare-earth elements (REEs) have many technological applications and are critically important in the manufacture of electric vehicles, communication devices, and industrial magnets. However, the global supply of rare-earth elements has faced shortages and price shocks. Current methods for separating and isolating individual rare-earth elements use large amounts of energy and organic solvents, raising concerns over environmental impacts. These factors have led to the investigation of nontraditional sources and separation techniques for these elements. Here, we describe a column-based system that uses a newly developed ligand-associated organosilica sorbent to concentrate and separate rare-earth elements from fly ash leachate. The fly ash used in this study originally contained 0.024 wt% rare-earth elements and the final oxide powder after enrichment contained > 10 wt% rare-earth elements, which is a enrichment of > 400 times. This process requires no additional organic solvents after the sorbent media has been synthesized, offering an alternative to the current standard using solvent extraction for rare-earth element recovery.

42 ENGINEERING↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

Multiscale investigations of europium(III) complexation with tetra- n -octyl diglycolamide confined in porous solid supports

The microscopic, short-range coordination environments and mesoscopic, long-range structures of Eu 3+ contacted with tetra-n-octyl diglycolamide (TODGA) confined on ordered mesoporous carbon (OMC) nanoparticles and Amberchrom CG 71 resin were probed using Eu L 3 -edge extended X ray absorption fine structure (EXAFS) as well as small-angle and wide-angle X ray scattering, SAXS and WAXS, respectively. A homoleptic Eu(TODGA) 3 3+ coordination complex typical of liquid-liquid extraction (LLE) chemistry is present under low Eu 3+ loading conditions on both solid supports. Deviations from this traditional structure motif appear at hyperstoichiometric Eu 3+ loadings, above the 1:3 Eu 3+ to TODGA mole ratio. Microcrystalline-like domains with multinuclear Eu speciation are templated by use of these high Eu 3+ loading conditions with the functionalized OMC materials, highlighting a major departure of liquid-solid extraction chromatography (EXC) from the coordination chemistry of LLE. No such long-range spatial coherence was observed for analogous polyacrylic resin materials. Furthermore, these results demonstrate both the similarities and differences between multiscale structures in LLE and EXC, underscoring the opportunities for improved separation techniques based on solid supports with long-range spatial coherence (e.g., OMC systems) and without it (e.g., resin materials). Since crystallization was the first approach to adjacent lanthanide separations, the prospect of templating microcrystalline TODGA-lanthanide complexes that are otherwise not prone to crystallization by use of OMC nanoparticles represents a new entry to addressing long-standing issues in purification by liquid-solid phase separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using a Chromatographic Pseudophase Model To Elucidate the Mechanism of Olefin Separation by Silver(I) Ions in Ionic Liquids

Silver(I) ions undergo selective olefin complexation and have been utilized in various olefin/paraffin separation techniques such as argentation chromatography and facilitated transport membranes. Ionic liquids (ILs) are solvents known for their low vapor pressure, high thermal stability, low melting points, and ability to promote a favorable solvation environment for silver(I) ion–olefin interactions. To develop highly selective separation systems, a fundamental understanding of analyte partitioning to the stationary phase and the thermodynamic driving forces behind solvation is required. In this study, a chromatographic model treating silver(I) ions as a pseudophase is constructed and employed for the first time to investigate the olefin separation mechanism in silver(I) salt/IL mixtures. Stationary phases containing varying amounts of noncoordinated silver(I) salt ([Ag + ][NTf 2 – ]) dissolved in the 1-decyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 10 MIM + ][NTf 2 – ]) IL are utilized to determine the partition coefficients of various analytes including alkanes, alkenes, alkynes, aromatics, aldehyde, esters, and ketones. As ligand coordination to silver(I) ions is known to lower its olefin complexation capability, this study also examines two different types of coordinated silver(I) ion pseudophases, namely, monocoordinated silver(I) salt ([Ag + (1-decyl-2-methylimidazole, DMIM)][NTf 2 – ]) and dicoordinated silver(I) salt ([Ag + (1-methylimidazole, MIM)(DMIM)][NTf 2 – ]). The extent of olefin partitioning to the coordinated silver(I) ion pseudophases over the carrier gas and IL decreased by up to two orders of magnitude. Values for enthalpy, entropy, and free energy of solvation were determined for the three silver(I) ion-containing systems. Olefin retention was observed to be enthalpically dominated, while ligand coordination to the silver(I) ion pseudophase resulted in variations for both enthalpic and entropic contributions to the free energy of solvation. Furthermore, the developed model can be used to study chemical changes that occur in silver(I) ions over time as well as identify optimal silver(I) salt/IL mixtures that yield high olefin selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing Experimental Results for Large Particle Separation from Non-Newtonian Slurries Using Full and Tapered Bump Arrays

To separate particles from carrier fluids arrays of staggered posts inserted into the flow stream can be employed. The smaller particles follow the flow stream while the larger particles move laterally to one side. During flow, the concentration of particulate increases in one direction and decreases in the other crosswise direction. This technique separates the particles from the carrier fluid. Experiments using a slurry with non-Newtonian rheology were conducted to evaluate large particle separation from the non-Newtonian carrier fluid using bump arrays. The bentonite kaolin clay slurry with non-Newtonian rheology was spiked with large diameter inert glass particles. Experiments with flow through lateral displacement arrays evaluated the performance of particle separation using two array configurations: a full array with all posts and a tapered array with posts removed in a triangular portion of the array past the rows of anticipated particle of separation. The posts are staggered posts to promote particle segregation to one side of the flow channel. Using this type of array for removing particles from non-Newtonian yield stress slurries is novel and we present unique results. In this paper, the performance of full and tapered arrays are compared. These results have many industrial applications including removing particles from slurries of nuclear waste. Large particle removal is an important step in waste processing.

slurry, solids removal, deterministic lateral disp↗

Implementation and evaluation of multi-dual mode counter-current chromatography in the CUP Modeler software

Counter-current chromatography (CCC) is a separation technique that utilizes immiscible solvent pairs as stationary and mobile phases, which imparts numerous benefits compared to solid-liquid chromatography including the ability to treat either the more-dense or less-dense solvent layer as the mobile phase. Multi-dual mode (MDM) is a CCC elution mode capable of improving the separation of closely eluting compounds by alternating upper- and lower-layer solvent flows in opposing directions within the same separation. While some effort has been made to model MDM, implementation of these models in experimental design has yet to be widely adopted. Accordingly, we further developed our previously published cell utilized partitioning (CUP) model to include MDM predictions with CCC and packaged the full suite of CUP modeling capabilities into a user-friendly, open-source tool called the CUP Modeler. The mathematical model for MDM CCC was derived and validated with experimental separation of ethyl guaiacol (EG) and ethyl phenol (EP), two compounds that co-elute in our previously demonstrated reductive catalytic fractionation (RCF) lignin monomer isolation method. The developed MDM model provided insights into the effect of multiple operating parameters - including stationary phase retention, flow rate, column efficiency, feed concentration ratio, selectivity factor, and solute distribution ratios - on the separation yields, productivity, and purities. Our model agreed with prevailing understanding of MDM but also revealed new insights including that the ideal distribution ratios for co-eluting solutes to be separated by MDM is between 1.1 and 1.5, with the lower value ideally close to 1.25. Overall, this work provides fundamental insights for MDM process design and enables broader adoption of general liquid-liquid chromatography with a new, open-source user-friendly interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanistic Investigation of Co(II) Extraction by TODGA to Aid Nuclear Forensic Separations

Nuclear forensic (NF) analysis supports law enforcement inquiries by analyzing evidence tainted with radioactive substances. Separation techniques can be used to identify and quantify actinides and fission 15 products in post-detonation (PD) debris. Environmental transition metals, also present in PD residues, have been observed to impact critical isotope extractions. For example, radio stable cobalt (Co), ubiquitous in urban environments, particularly in corrosion-resistant alloys, paint-drying agents, dyes, and pigments, can impact the separation of important actinides and fission products. The presented work aims to elucidate the chemistry Q2 governing Co extraction in samples pertinent to PDNF. Chemistry between Co and N,N,N,‘N’-tetraoctyl diglyco- 20 lamide (TODGA), the ligand present in the commercial chromatographic resin diglycolamide (DGA), were studied via solvent and chromatographic extraction and spectroscopic analyses. These results indicate that a tetrahedral Co(II) species is extracted by TODGA from highly acidic (>5M HCl) solutions via a spontaneous entropy-driven reaction. Furthermore, extraction trends in varied acid concentrations are consistent between solvent extraction and chromatographic extraction methods.

activation product↗

Complete separation of benzene-cyclohexene-cyclohexane mixtures via temperature-dependent molecular sieving by a flexible chain-like coordination polymer

Abstract The separation and purification of C6 cyclic hydrocarbons (benzene, cyclohexene, cyclohexane) represent a critically important but energy intensive process. Developing adsorptive separation technique to replace thermally driven distillation processes holds great promise to significantly reduce energy consumption. Here we report a flexible one-dimensional coordination polymer as an efficient adsorbent to discriminate ternary C6 cyclic hydrocarbons via an ideal molecular sieving mechanism. The compound undergoes fully reversible structural transformation associated with removal/re-coordination of water molecules and between activated and hydrocarbon-loaded forms. It exhibits distinct temperature- and adsorbate-dependent adsorption behavior which facilitates the complete separation of benzene, cyclohexene and cyclohexane from their binary and ternary mixtures, with the record-high uptake ratios for C 6 H 6 /C 6 H 12 and C 6 H 10 /C 6 H 12 in vapor phase and highest binary and ternary selectivities in liquid phase. In situ infrared spectroscopic analysis and ab initio calculations provide insight into the host-guest interactions and their effect on the preferential adsorption and structural transformation.

36 MATERIALS SCIENCE↗

Tuning the Solvation and Solubility Properties of Molecularly Heterogeneous Nonionic Deep Eutectic Solvents via Interface Organization

Common separation techniques, such as liquid− liquid extraction, are usually used for extractions and purifications due to their industrial scalability and affordability. However, these well-established practices are hindered by low selectivity and challenges in recovering solutes and solvents. Deep eutectic solvents (DES), a fairly new type of solvent, have the potential to overcome these issues. DESs are binary mixtures whose physical properties can be tuned by selecting the appropriate precursors to facilitate and/or enhance processes such as extraction. A promising DES for selective separations is formed when lauric acid (LA) is mixed with N-methylacetamide (NMA). This LA-NMA DES has a heterogeneous microscopic structure that can solvate compounds with completely different polarities. This study explores how forming an organized structure on the mesoscale affects the solubility of nonpolar solutes in nonionic DESs. To this end, the molecular and mesoscale structures and their effect on the solubility and solvation properties are evaluated for the LA-NMA DES and two new DESs with slight chemical variations in their precursors. It is observed that the organization of the nonpolar DES domains and, consequently, of their interfaces directly relates to the solubility of nonpolar compounds. Specifically, correctly selecting the DES precursors that form organized nonpolar domains leads to an organized interface in which the nonpolar solutes are solvated, thereby increasing the solubility. Additionally, enhanced dissolution power was observed in a completely different DES with mesoscale order in its molecular structure and composed of menthol and lauric acid. The latter result further validates the proposed tunability of the DES dissolution power through organized interfaces, extending it beyond a specific DES family and opening the possibility of new extraction-tailored designer solvents.

Extraction↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Effect of iodides on thermal behavior and phase partitioning in LiCl-KCl

Liquid-fueled molten salt reactors (MSRs) are designed to operate with fissile materials and, ultimately, fission products dissolved in the primary molten salt coolant. Understanding the speciation and transport of iodine—a high-yield fission product—is essential because this element’s accidental release poses significant environmental concerns due to its capacity to be readily absorbed by the human thyroid gland. Here, we report the impact of iodide species (LiI and KI) on phase transitions, phase distribution, and phase stability in LiCl–KCl-eutectic salt mixtures. The study employed a combination of computational and experimental techniques, including thermodynamic FactSage calculations, differential scanning calorimetry, and high-temperature X-ray diffraction. The results indicate that the presence of iodide (10–25 wt%) significantly alters the melting behavior of the LiCl–KCleutectic system. Adding 10 wt% LiI has a more-pronounced effect than 10 wt% KI, as LiI converts to KI, leading to formation of LiCl, thereby, altering the LiCl-KCl ratio which significantly affects the melting temperature of the mixture. Furthermore, the evolution of crystalline structure, solid-fraction composition, and the dynamics of mixed-halide solid–liquid partitioning as a function of temperature indicate the potential for selective iodide separation from chloride-salt mixtures via solid–liquid separation techniques. Overall, the presented findings provide valuable insights that are beneficial for the design and operation of MSRs, as well as for the safe handling and effective processing of used nuclear fuel using advanced pyrochemical techniques.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗