Search NASA⌕ Search

SEARCH · Search NASA

Results for “serrated flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Aerodynamic effects of leading-edge serrations on a two-dimensional airfoil

An investigation was conducted to determine the flow field and aerodynamic effects of leading-edge serrations on a two-dimensional airfoil at a Mach number of 0.13. The model was a NACA 66-012 airfoil section with a 0.76 m (30 in.) chord, 1.02 m (40 in.) span, and floor and end plates. It was mounted in the Ames 7- by 10-Foot Wind Tunnel. Serrated brass strips of various sizes and shapes were attached to the model in the region of the leading edge. Force and moment data, and photographs of tuft patterns and of oil flow patterns are presented. Results indicated that the smaller serrations, when properly placed on the airfoil, created vortices that increased maximum lift and angle of attack for maximum lift. The drag of the airfoil was not increased by these serrations at airfoil angles of attack near zero and was decreased at large angles of attack. Important parameters were serration size, position on the airfoil, and spacing between serrations.

Soderman, P. T.↗

Investigation of acoustic effects of leading-edge serrations on airfoils

This paper presents and interprets a series of extensive studies of the application of leading-edge serrations as a device for reducing the vortex noise radiated from stationary and rotating airfoils in low Reynolds number flow. In these studies, a variety of serrations were attached at selected locations near the leading edge of stationary and rotating airfoils. The noise levels of the airfoils were reduced considerably with the serrations attached. An explanation of the aeroacoustic flow mechanisms involved is given.

Hersh, A. S.↗

Fluidic Chevrons for Jet Noise Reduction

Chevron mixing devices are used to reduce noise from commercial separate-flow turbofan engines. Mechanical chevron serrations at the nozzle trailing edge generate axial vorticity that enhances jet plume mixing and consequently reduces far-field noise. Fluidic chevrons generated with air injected near the nozzle trailing edge create a vorticity field similar to that of the mechanical chevrons and allow more flexibility in controlling acoustic and thrust performance than a passive mechanical design. In addition, the design of such a system has the future potential for actively controlling jet noise by pulsing or otherwise optimally distributing the injected air. Scale model jet noise experiments have been performed in the NASA Langley Low Speed Aeroacoustic Wind Tunnel to investigate the fluidic chevron concept. Acoustic data from different fluidic chevron designs are shown. Varying degrees of noise reduction are achieved depending on the injection pattern and injection flow conditions. CFD results were used to select design concepts that displayed axial vorticity growth similar to that associated with mechanical chevrons and qualitatively describe the air injection flow and the impact on acoustic performance.

Kinzie, Kevin↗

Water Tunnel Flow Visualization Study Through Poststall of 12 Novel Planform Shapes

To determine the flow field characteristics of 12 planform geometries, a flow visualization investigation was conducted in the Langley 16- by 24-Inch Water Tunnel. Concepts studied included flat plate representations of diamond wings, twin bodies, double wings, cutout wing configurations, and serrated forebodies. The off-surface flow patterns were identified by injecting colored dyes from the model surface into the free-stream flow. These dyes generally were injected so that the localized vortical flow patterns were visualized. Photographs were obtained for angles of attack ranging from 10' to 50', and all investigations were conducted at a test section speed of 0.25 ft per sec. Results from the investigation indicate that the formation of strong vortices on highly swept forebodies can improve poststall lift characteristics; however, the asymmetric bursting of these vortices could produce substantial control problems. A wing cutout was found to significantly alter the position of the forebody vortex on the wing by shifting the vortex inboard. Serrated forebodies were found to effectively generate multiple vortices over the configuration. Vortices from 65' swept forebody serrations tended to roll together, while vortices from 40' swept serrations were more effective in generating additional lift caused by their more independent nature.

Gatlin, Gregory M.↗

Utilizing Strain Rate Jump Testing to Predict Flow Formability of Al Alloys Sensitive to Portevin-Le Chatelier Instabilities

Predicting the flow formability of Al alloys is challenging due to the incremental deformation, complex loading path, and wide range of strain rates characteristic of the process. State-of-the-art research efforts have primarily focused on formability metrics derived from ambient temperature, constant strain rate uniaxial tensile testing. However, Al alloys in formable tempers tend to exhibit serrated Portevin-Le Chatelier (PLC) flow. The appearance of PLC instabilities implies a negative strain rate sensitivity, loss of tensile area reduction capacity, and decreased formability. Elevated temperature and interrupted strain rate tensile tests of relevant Al alloys were conducted to investigate the effects of rapid changes in strain rate (analogous to a forming increment by a passing roller) on common formability metrics. Emphasis was placed on the character/extent of PLC instabilities using digital image correlation strain measurements. The outcome of this work highlights the possibility of predicting flow formability using strain rate jump testing.

flow forming↗

Acoustic testing of a 1.5 pressure ratio low tip speed fan with a serrated rotor (QEP fan B scale model)

A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a serrated rotor leading edge to determine its effects on noise generation. The serrated rotor was produced by cutting teeth into the leading edge of the nominal rotor blades. The effects of speed and exhaust nozzle area on the scale models noise characteristics were investigated with both the nominal rotor and serrated rotor. Acoustic results indicate the serrations reduced front quadrant PNL's at takeoff power. In particular, the 200 foot (61.0 m) sideline noise was reduced from 3 to 4 PNdb at 40 deg for nominal and large nozzle operation. However, the rear quadrant maximum sideline PNL's were increased 1.5 to 3 PNdb at approach thust and up to 2 PNdb at takeoff thust with these serrated rotor blades. The configuration with the serrated rotor produced the lowest maximum 200 foot (61.0 m) sideline PNL for any given thust when the large nozzle (116% of design area) was employed.

Kazin, S. B.↗

Effect of LEO cycling on 125 Ah advanced design IPV nickel-hydrogen battery cells

An advanced 125 Ah individual pressure vessel (IPV) nickel-hydrogen cell was designed. The primary function of the advanced cell, is to store and deliver energy for long term, low earth-orbit (LEO) spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent potassium hydroxide (KOH) electrolyte, (2) use of a patented catalyzed wall wick, (3) use of serrated edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management, and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion. Six 125 Ah flight cells based on this design were fabricated by Eagle-Picher. Three of the cells contain all of the advanced features (test cells) and three are the same as the test cells except they don't have catalyst on the wall wick (control cells). All six cells are in the process of being evaluated in a LEO cycle life test. The cells have accumulated about 4700 LEO cycles (60 percent DOD 10 C). There have been no cell failures, the catalyzed wall wick cells however, are performing better.

Smithrick, John J.↗

Effect of LEO cycling on 125 Ah advanced design IPV nickel-hydrogen battery cells

An advanced 125 Ah individual pressure vessel (IPV) nickel-hydrogen cell was designed. The primary function of the advanced cell is to store and deliver energy for long-term, low earth-orbit (LEO) spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent potassium hydroxide (KOH) electrolyte, (2) use of a patented catalyzed wall wick, (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management, and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion. Six 125-Ah flight cells based on this design were fabricated by Eagle-Picher. Three of the cells contain all of the advanced features (test cells) and three are the same as the test cells except they don't have catalyst on the wall wick (control cells). All six cells are in the process of being evaluated in a LEO cycle life test. The cells have accumulated about 4700 LEO cycles (60 percent DOD 10 C). There have been no cell failures; the catalyzed wall wick cells, however, are performing better.

Smithrick, John J.↗

Validation test of advanced technology for IPV nickel-hydrogen flight cells: Update

Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the low-earth-orbit (LEO) cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing at the Naval Weapons Support Center (NWSC), Crane, Indiana under a NASA Lewis Contract. An advanced 125 Ah IPV nickel-hydrogen cell was designed. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion. The advanced cell design is in the process of being validated using real time LEO cycle life testing of NWSC, Crane, Indiana. An update of validation test results confirming this technology is presented.

Smithrick, John J.↗

Validation test of 125 Ah advanced design IPV nickel-hydrogen flight cells

An update of validation test results confirming the advanced design nickel-hydrogen cell is presented. An advanced 125 Ah individual pressure vessel (IPV) nickel-hydrogen cell was designed. The primary function of the advanced cell is to store and deliver energy for long-term, Low-Earth-Orbit (LEO) spacecraft missions. The new features of this design, which are not incorporated in state-of-the-art design cells, are: (1) use of 26 percent rather than 31 percent potassium hydroxide (KOH) electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion. Six 125 Ah flight cells based on this design were fabricated by Eagle-Picher. Three of the cells contain all of the advanced features (test cells) and three are the same as the test cells except they do not have catalyst on the wall wick (control cells). All six cells are in the process of being evaluated in a LEO cycle life test at the Naval Weapons Support Center, Crane, IN, under a NASA Lewis Research Center contract. The catalyzed wall wick cells have been cycled for over 19000 cycles with no cell failures in the continuing test. Two of the noncatalyzed wall wick cells failed (cycles 9588 and 13,900).

Smithrick, John J.↗

Validation test of advanced technology for IPV nickel-hydrogen flight cells - Update

Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the LEO cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion.

Smithrick, John J.↗

Validation test of 125 Ah advanced design IPV nickel-hydrogen flight cells

An update of validation test results confirming the advanced design nickel-hydrogen cell is presented. An advanced 125 Ah individual pressure vessel Ni-H cell was designed. The primary function of the advanced cell is to store and deliver energy for long-term LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous O and H flow within the cell, while maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack to accommodate Ni electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of Ni electrode expansion. Six 125 Ah flight cells based on this design were fabricated; the catalyzed wall wick cells have been cycled for over 19,000 cycles with no cell failures in the continuing test. Two of the noncatalyzed wall wick cells failed (cycles 9588 and 13,900).

Smithrick, John J.↗

Unraveling the discontinuous plastic flow of a Co-Cr-Fe-Ni-Mo multiprincipal-element alloy at deep cryogenic temperatures

We report an analysis of the discontinuous plastic flow of a multiprincipal-element alloy, Co 17.5 Cr 12.5 Fe 55 Ni 10 Mo 5 (atomic percent, at. %), in the temperature range of 0.5–4.2 K showing serrated deformation curves. Using the analytical techniques, we studied the statistics of the stress drops associated with the unstable plastic flow. The analysis showed that the complexity and heterogeneity of a discontinuous plastic flow were reduced when the temperature was lowered. This behavior was associated with the effects of dynamic recovery and adiabatic heating on the dislocation-density evolution.

36 MATERIALS SCIENCE↗

Wind-tunnel investigations of wings with serrated sharp trailing edges

Exploratory wind-tunnel force measurements are presented for two wing geometries with small-scale planar and nonplanar serrated trailing-edge devices (chord-Reynolds numbers ranged from 1.0 to 3.7 million). The planar serrated trailing-edge extensions reduced the drag at conditions when trailing-edge separation occurred at low angles of attack. The introduction of serrations reduced or eliminated the drag penalty, due to the small (1-2 percent of the chord length) nonplanar trailing-edge flaps, while maintaining the effects of increase in camber. The presence of streamwise vortices immediately downstream of the serrated trailing edges is believed to have favorably affected the boundary-layer flow approaching the trailing edge and the near-wake development, resulting in reduced pressure (form) drag.

Vijgen, P. M. H. W.↗

Wind-tunnel investigations of wings with serrated sharp trailing edges

Exploratory wind-tunnel force measurements are presented for two wing geometries with small-scale planar and nonplanar serrated trailing-edge devices (chord-Reynolds numbers ranged from 1.0 - 3.7 x 10 to the 6th). The planar serrated trailing-edge extensions reduced the drag at conditions when trailing-edge separation occurred at low angles of attack. The introduction of serrations reduced or eliminated the drag penalty due to the small (1-2 percent of the chord length) nonplanar trailing-edge flaps, while maintaining the effects of increase in camber. The presence of streamwise vortices immediately downstream of the serrated trailing edges is believed to have favorably affected the boundary-layer flow approaching the trailing edge and the near-wake development, resulting in reduced pressure drag.

Vijgen, P. M. H. W.↗

Cascade tests of serrated leading edge blading at high subsonic speeds

Cascade tests of two-dimensional fan rotor blade rows were performed to investigate the effects of leading edge serration on acoustic and aerodynamic performance. The test configurations covered a range of serration tooth geometries. Tests were performed to investigate effects of inlet air angle and velocity on performance. Aerodynamic performance was determined by flow surveys at the mid-span of the blade exit. Acoustic performance was determined by wake turbulence surveys and sound measurements in the semireverberent exhaust chamber. Measured acoustic and aerodynamic performance was comparable and indicated that a serration length of about six percent blade chord yields minimum noise generation and minimum total pressure losses.

Smith, E. G.↗

Aerodynamic performance of flared fan nozzles used as inlets

Tests were conducted in a low speed wind tunnel to determine the aerodynamic performance of several flared fan nozzles. Each of the flared nozzles was a downstream-facing inlet to a model fan that was used to simulate a variable pitch fan during reverse thrust operation. The total pressure recovery of each of the flared nozzles as well as that of an unflared nozzle and a serrated flare nozzle was obtained for comparison. The aerodynamic performance of a selected flared nozzle was considered in further detail. The nozzle surface pressures for a flared nozzle were also determined. Results indicated that the differences in aerodynamic performance among the nozzles were most apparent at the wind-tunnel-off condition. A nonzero free stream velocity significantly reduced the perforamnce of all the nozzles, and crosswind flow (free stream flow perpendicular to the model axis) further reduced the performance of the nozzles. The unflared nozzle and the serrated flare nozzle had reduced aerodynamic performance compared to a solid surface flared nozzle.

Dietrich, D. A.↗