Evaluation of cooling setpoint setback savings in commercial buildings using electricity and exterior temperature time series data

Commercial buildings account for a significant amount of total energy produced in the US, and the Heating Ventilation and Cooling (HVAC) systems are one of the most significant components of their overall consumption. In this study, we proposed a new data-driven approach to evaluate HVAC cooling systems in commercial buildings and identify savings opportunities. The focus is an investigation of the impact of thermostat setpoint setback but using only whole building, electricity data taken at 15-min intervals for the analysis. We conducted a comparative study of setpoint setback characteristics on 432 commercial buildings with 5 building usage types across the United States. To accomplish this, both piecewise and Random Forest regression algorithms were employed using electricity and exterior temperature datasets to identify operational characteristics and the effective setpoints in the building to determine the corresponding savings opportunities. Both occupied and unoccupied time periods were studied across cooling degree days (CDD), when air conditioning is typically operational. Here the results show that in commercial buildings, on average, cooling systems account for 9.5% of total consumption. When a one degree setback during the cooling season is applied, an average of approximately 1.1% of annual consumption is achieved; retail and office buildings demonstrate the highest potential for savings. Additionally, we identified that the number of cooling degree days and base to peak ratio (BPR) are the most important variables for predicting the magnitude of the consumption of cooling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Airport and Heliport Setbacks

This dataset represents a first-order quantification of airport and heliport setback requirements based on the Federal Aviation Administration (FAA) 14 CFR Part 77.9. It defines the following FAA notice criteria that we use to create runway buffers. Runways longer than 3,200 feet receive a 20,000 foot buffer, runways less than 3,200 feet long receive a buffer of 10,000 feet, and heliports receive a buffer of 5,000 feet. A setback requirement is a minimum distance from an airport or heliport that an energy project may be developed. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

airport↗

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Next Generation Weather Radar (NEXRAD) Setback (4-km)

The Next Generation Weather Radar (NEXRAD) system is a network of doppler radar operated jointly by the National Weather Service (NWS), the Federal Aviation Administration (FAA), and the U.S. Air Force. This dataset represents 4-kilometer setback requirements typically applied to wind energy development. A setback requirement is a minimum distance away that an energy project may be developed. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

Airspace/Defense↗

ComStock Measure Scenario Documentation: Reduced Thermostat Setbacks for Heat Pumps

This report provides documentation of a measure for the End Use Savings Shapes project, which consists of analysis of different energy efficiency and renewable energy measures on the commercial building stock, using NREL's ComStock tool. The measure consists of a reduction in thermostat setbacks for air-source heat pump RTUs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concentrating solar thermal power in the U.S.: lessons from setbacks at Ivanpah, light for the future

Concentrating solar thermal power (CSP) exhibits promise as a source of firm electricity. The proposed termination of Ivanpah’s power purchase agreement hinders confidence in the country’s CSP future. This work highlights how the lack of thermal energy storage (TES) undermined the first-of-a-kind plant’s economics as California’s grid transformed. Then, possible futures of the Ivanpah facility are analyzed; results show retrofitting with state-of-the-art TES systems could provide better returns.

14 SOLAR ENERGY↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Siting Ordinances on Land Availability for Wind and Solar Development

In the United States, many siting regulations for wind and solar developments are created at the county or township level. Here we survey local zoning ordinances across the contiguous United States to understand the types and frequency of ordinances that might impact wind and solar development. We identify over 1,800 ordinances for wind and more than 800 ordinances for solar in 2022. To understand the impact of ordinances on anticipated land availability, we use spatial modelling on the setbacks specified in the ordinances. Extrapolating the setbacks throughout the country can reduce wind and solar resources by up to 87% and 38%, respectively, depending on the size of the setbacks applied. These results indicate the importance of capturing setback ordinances in resources assessments so as to not overstate resource potential, especially when considering highly decarbonized futures.

county↗

Impact of Siting Ordinances on Land Availability for Wind and Solar Development

In the United States, many siting regulations for wind and solar developments are created at the county or township level. Here we survey local zoning ordinances across the contiguous United States to understand the types and frequency of ordinances that might impact wind and solar development. We identify over 1,800 ordinances for wind and more than 800 ordinances for solar in 2022. To understand the impact of ordinances on anticipated land availability, we use spatial modelling on the setbacks specified in the ordinances. Extrapolating the setbacks throughout the country can reduce wind and solar resources by up to 87% and 38%, respectively, depending on the size of the setbacks applied. These results indicate the importance of capturing setback ordinances in resources assessments so as to not overstate resource potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comfort in High-Performance Homes in a Hot-Humid Climate

TO5 2.3.2: Large-Scale Temperature Study Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known about how space-conditioning systems are actually operating in the field and if these systems are meeting those standards. Unconventional space-conditioning systems may be necessary for low-load homes in the future. It is important to know how current systems are functioning in existing homes and to what temperatures occupants typically set the thermostats in their homes. The U.S. Department of Energy's Building America research team IBACOS set out to find some answers. By using low-cost data loggers and occupant surveys to monitor 37 single-family homes that have standard heating, ventilating, and air-conditioning (HVAC) equipment, the team gained insight into how sensitive occupants are to comfort in their homes relative to the ACCA and ASHRAE standards. This study focused on one climate zone (hot-humid); however, future studies may find differences among occupants- ideas of thermal comfort in other climate zones. Data were collected from installed sensors during a 2-month period from late August 2014 through late October 2014. The final aspect of this project was to review the business metrics associated with builders involved in a comfort and performance guarantee program. The results of this study-taken as an aggregate-show that the homes provided room-to-room temperature differences less than 6 degrees F 95% of the time. Temperature differences were less than 4 degrees F 80% of the time. Some homes showed better or worse performance. On average, two-story homes had a 3.3 degrees F temperature difference between rooms; single-story homes had an average of a 2.2 degrees F temperature difference between rooms. Occupants who did not use programmable thermostats had an average set point of 75 degrees F. Homes in which the thermostats were programmed with a setback schedule showed a median baseline temperature value of 74 degrees F and had a median afternoon setback of 75 degrees F. System runtime was analyzed and showed that the room-to-room temperature uniformity in some homes worsened during an on cycle, whereas the uniformity improved in other homes. That is, when the system was running, some rooms were receiving too much or too little air relative to the rest of the house, and the temperatures in those rooms were moving away from the temperatures of the other rooms in the house. Finally, analysis of the thermostat data shows a wide degree of variability among homes in the study. Interpretation of the measured data suggests that 21 occupants made no regular adjustments to the thermostats in their homes, seven had regular setbacks, seven showed varying setbacks, and 10 appeared to follow no pattern (with random adjustments). Ultimately, the data show that current systems are maintaining expected levels of comfort. As expected, it is more challenging to maintain a uniform temperature in all rooms of two-story homes, and future systems should address this issue. Furthermore, the data show that the majority of homes maintained relative humidity levels below 60% without any supplemental dehumidification

ACCA Manual RS↗

Competing Use Analysis for Offshore Renewables and Subsea Cables

Demand for abundant and diverse resources in the oceans is growing, necessitating marine spatial planning. To inform development of Marine Hydrokinetic (MHK) and Offshore Wind (OSW) resources, the Department of Energy (DOE) has asked NREL to identify the competing uses areas between promising MHK/OSW sites and submarine power and telecommunications cables. The first step in this work is to identify and quantify the overlap between the MHK/OSW resource availability and existing cable routes. The analysis is done in terms of resource area because the task of quantifying actual impacts on available resource is a non-trivial undertaking that involves subjective decisions of identifying resource opportunities. Quantifying overlap in-terms of resource area?on the other hand?is significantly more straight forward, and useful to marine spatial planners. This dataset of polygons describes recommended setback areas from submarine cables for marine renewable energy Development. Two archive files are provided: 1. NREL Cables Setback-Polygons.zip contains the following GeoJSON files: 1.a. cables_100ft.geojson: The Code of Federal Regulations (CFR 585.301) specifies that the legal right of way for submarine cables is 100 ft (~30 meters) to either side of the cable (i.e., 200 ft wide). 1.b. cables_2z.geojson: The International Cable Protection Committee (ICPC) of the North American Submarine Cable Association (NASCA) recommends setback distances for new facilities as the maximum of 500 m or twice the bottom depth (2z), per ICPC Recommendation 13 No. 2 (Communications Security, Reliability and Interoperability Council IV 2014). For depths 250 m, 2 * depth is to be used. 1.c. cables_3z.geojson: The ICPC of NASCA recommends setback distances for new cables as the maximum of 500 m or three times the bottom depth (3z), per ICPC Recommendation 2 No. 10 (Communications Security, Reliability and Interoperability Council IV 2014). So for depths 167 m, 3 * depth is to be used. 2. NREL Submarine Cable Analysis Code Data Presentations.zip contains all files (code, data, README, etc) from release 0.1 of this Github repository for possibly regenerating the product as submarine cable configurations change: https://github.com/ecoquants/nrel-cables. For more details, please see the link to the full report for which this data product is a supplemental output: Submarine Cable Analysis for U.S. Marine Renewable Energy Development by Ben Best and Levi Kilcher National Renewable Energy Laboratory

16 TIDAL AND WAVE POWER↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Martha's Vineyard, Massachusetts

This report presents a cold climate project that examines the relationships among very energy efficient single-family residential thermal enclosures, room-to-room temperature variations, and simplified space conditioning systems. The project was developed, designed, and built by South Mountain Company and is located in West Tisbury, Massachusetts, on the island of Martha’s Vineyard. This project allowed investigators to compare room-to-room temperatures in four virtually identical houses that were all built to the same construction standard. Each of the four all-electric homes has a single ductless heat pump unit (DHU) located in the main living space with a single programmable thermostatic control built into the unit. Each bedroom and the main bathroom have radiant electric resistance panels with individual nonprogrammable thermostatic controls that occupants can turn on and off for their comfort. Results indicate that temperature fluctuations in the living room resulting from aggressive setup and setback of the DHU may contribute to fewer hours when the bedroom temperatures are within ±2°F of the living room temperatures, compared to houses without setback. Solar gains in the living room, along with opening and closing doors, appear to have a significant impact on room-to-room temperature differences, as would be expected. Setback strategies do not appear to save energy but do contribute to significant temperature variations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Justifications for Liquid Hydrogen Exposure Distances

The previous separation distances in the National Fire Protection Association (NFPA) Hydrogen Technologies Code (NFPA 2, 2020 Edition) for bulk liquid hydrogen systems lack a well-documented basis and can be onerous. This report describes the technical justifications for revisions of the bulk liquid hydrogen storage setback distances in NFPA 2, 2023 Edition. Distances are calculated based on a leak area that is 5% of the nominal pipe flow area. Models from the open source HyRAM+ toolkit are used to justify the leak size as well as calculate consequence-based separation distances from that leak size. Validation and verification of the numerical models is provided, as well as justification for the harm criteria used for the determination of the setback distances for each exposure type. This report also reviews mitigations that could result in setback distance reduction. The resulting updates to the liquid hydrogen separation distances are well-documented, retrievable, repeatable, revisable, independently verified, and use experimental results to verify the models.

08 HYDROGEN↗