Search NASA⌕ Search

SEARCH · Search NASA

Results for “shaker test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A study of multiple-shaker modal survey testing

The principal objective was to examine and to assess the practical value of a method of multiple-shaker sinusoidal modal vibration testing known as Asher's method. Numerical studies which simulate the application of Asher's method and a unique experimental implementation of the method were completed. Another objective of the research was to develop and to demonstrate with numerical simulation a quantitative method for determining from transfer function data the number of dominant modes of vibration in sinusoidal structural response.

Hallauer, W. L., Jr.↗

Development of a new method in force limited vibration testing

The force limited vibration test approaches discussed in NASA-HDBK-7004C were developed to reduce overtesting associated with base shake vibration tests of aerospace hardware. This handbook outlines several different methods of specifying force limiting specifications. The basis for deriving force limiting specifications is related to the differences between mechanical impedances of typical aerospace hardware interfacing the mounting structures in flight configurations and the large impedances inherent in shaker vibration testing. Among these approaches, the semi-empirical method is presently the most widely used method to derive the force limiting specifications. This method is developed based on the assumption that the hardware interface responses are coherently excited. The inclusion of the incoherent excitation of the aerospace structures at mounting interfaces provides the basis for developing a more realistic force limiting specification that may be used to qualify flight hardware for launch environments using shaker testing. In this paper the semi-empirical method for defining force limiting specifications discussed in NASA handbook are reviewed using data recently obtained from a series of acoustic and vibration tests. A mathematical formation of a new force limiting approach based on considering the incoherent excitation of the hardware at their mounting interfaces is developed. Results from the analysis, which are correlated to the data obtained from a series of well instrumented acoustic and vibration tests, are discussed. The new approach provides much more realistic force limits that may further remove conservatism inherent in shaker vibration testing not accounted for by methods discussed in the NASA handbook.

Kolaini, Ali R.↗

An Integrated Analysis-Test Approach

This viewgraph presentation provides an overview of a project to develop a computer program which integrates data analysis and test procedures. The software application aims to propose a new perspective to traditional mechanical analysis and test procedures and to integrate pre-test and test analysis calculation methods. The program also should also be able to be used in portable devices and allows for the 'quasi-real time' analysis of data sent by electronic means. Test methods reviewed during this presentation include: shaker swept sine and random tests, shaker shock mode tests, shaker base driven model survey tests and acoustic tests.

Kaufman, Daniel↗

Vibration and Acoustic Testing for Mars Micromission Spacecraft

The objective of the Mars Micromission program being managed by the Jet Propulsion Laboratory (JPL) for NASA is to develop a common spacecraft that can carry telecommunications equipment and a variety of science payloads for exploration of Mars. The spacecraft will be capable of carrying robot landers and rovers, cameras, probes, balloons, gliders or aircraft, and telecommunications equipment to Mars at much lower cost than recent NASA Mars missions. The lightweight spacecraft (about 220 Kg mass) will be launched in a cooperative venture with CNES as a TWIN auxiliary payload on the Ariane 5 launch vehicle. Two or more Mars Micromission launches are planned for each Mars launch opportunity, which occur every 26 months. The Mars launch window for the first mission is November 1, 2002 through April 2003, which is planned to be a Mars airplane technology demonstration mission to coincide with the 100 year anniversary of the Kittyhawk flight. Several subsequent launches will create a telecommunications network orbiting Mars, which will provide for continuous communication with lenders and rovers on the Martian surface. Dedicated science payload flights to Mars are slated to start in 2005. This new cheaper and faster approach to Mars exploration calls for innovative approaches to the qualification of the Mars Micromission spacecraft for the Ariane 5 launch vibration and acoustic environments. JPL has in recent years implemented new approaches to spacecraft testing that may be effectively applied to the Mars Micromission. These include 1) force limited vibration testing, 2) combined loads, vibration and modal testing, and 3) direct acoustic testing. JPL has performed nearly 200 force limited vibration tests in the past 9 years; several of the tests were on spacecraft and large instruments, including the Cassini and Deep Space One spacecraft. Force limiting, which measures and limits the spacecraft base reaction force using triaxial force gages sandwiched between the spacecraft and the test fixture, alleviates the severe overtest at spacecraft resonances inherent in rigid fixture vibration tests. It has the distinct advantage over response limiting that the method is not dependent on the accuracy of a detailed dynamic model of the spacecraft. Combined loads, vibration, and modal testing were recently performed on the QuikSCAT spacecraft. The combined tests were performed in a single test setup per axis on a vibration shaker, reducing test time by a factor of two or three. Force gages were employed to measure the true c.g. acceleration of the spacecraft for structural loads verification using a sine burst test, to automatically notch random vibration test input accelerations at spacecraft resonances based on predetermined force limits, and to directly measure modal masses in a base drive modal test. In addition to these combined tests on the shaker, the QuikSCAT spacecraft was subjected to a direct field acoustic test by surrounding the spacecraft, still on the vibration shaker, with rock concert type acoustic speakers. Since the spacecraft contractor does not have a reverberant field acoustic test facility, performing a direct field acoustic test -saved the program nearly two weeks schedule time that would have been required for packing / unpacking and shipping of the spacecraft. This paper discusses the rationale behind and advantages of the above test approaches and provides examples of their actual implementation and comparisons to flight data. The applicability of the test approaches to Mars Micromission spacecraft qualification is discussed.

Kern, Dennis L.↗

Multiple Shaker Placement for Ground Vibration Test of X-59 Aircraft Using Topology Optimization

A multiple shaker placement methodology is developed and tested using a topology optimization technique. Current multiple shaker placement methodology requires optimum accelerometer placement and optimum single-shaker placement techniques. The proposed methodology is tested using a finite element model of the X-59 Low Boom Flight Demonstrator aircraft. The effective independence and the driving point acceleration transfer function (DPATF) methods are used for the accelerometer placement study. In this study, four shakers are used to excite each mode more effectively during the ground vibration test; all the modes of interest thus are separated into four groups. Each shaker takes care of a separate group of modes. Grouping the modes of interest is performed utilizing topology optimization. The number of modes for each group therefore will be automatically decided during grouping. For each group of modes, perform the following two steps to determine optimal location of four shakers: 1) At each accelerometer location, compare the magnitude of DPATF values at natural frequencies, select the minimum value, and make a vector with these minimum values of the DPATF magnitudes for each group; and 2) Select the degrees of freedom corresponding to the maximum value of this vector. The objective function value is the maximum value of the vector with minimum value of the magnitude of the superposed acceleration transfer function. This objective function value is maximized by changing the modes for each group. Forty accelerometers are enough to have good correlation between mode shapes obtained from the reduced order model and the simulated ground vibration test.

Optimization Analysis↗

A Procedure for Accurately Measuring the Shaker Overturning Moment During Random Vibration Tests

Motivation: For large system level random vibration tests, there may be some concerns about the shaker's capability for the overturning moment. It is the test conductor's responsibility to predict and monitor the overturning moment during random vibration tests. If the predicted moment is close to the shaker's capability, test conductor must measure the instantaneous moment at low levels and extrapolate to higher levels. That data will be used to decide whether it is safe to proceed to the next test level. Challenge: Kistler analog formulation for computing the real-time moment is only applicable to very limited cases in which we have 3 or 4 load cells installed at shaker interface with hardware. Approach: To overcome that limitation, a simple procedure was developed for computing the overturning moment time histories using the measured time histories of the individual load cells.

predict overturning↗

Test program to develop vibroacoustics test criteria for the Galileo bus

In order to define random vibration test requirements for Galileo bus-mounted hardware, an extensive vibroacoustics test program was conducted on hardware available from the previous Voyager spacecraft development program. The Galileo test program consisted of acoustic tests on three configurations of the Voyager Dynamic Test Model bus and shaker random vibration tests on two flight-like bus equipment bay assemblies and one dummy equipment bay assembly. The primary goal of the acoustic tests was to define vibration levels at locations on the bus structure representative of inputs to bus equipment bay assemblies and to obtain response data on bus bay subassemblies for correlation with the vibration tests response data. The primary purpose of the vibration tests was to determine if the vibration tests excited subassembly responses at least as severely as the bus acoustic tests.

Kern, D. L.↗

Application of the Semi-Empirical Force-Limiting Approach for the CoNNeCT SCAN Testbed

The semi-empirical force-limited vibration method was developed and implemented for payload testing to limit the structural impedance mismatch (high force) that occurs during shaker vibration testing. The method has since been extended for use in analytical models. The Space Communications and Navigation Testbed (SCAN Testbed), known at NASA Glenn Research Center (GRC) as, the Communications, Navigation, and Networking re-Configurable Testbed (CoNNeCT) project utilized force-limited testing and analysis following the semi-empirical approach. This presentation presents the steps in performing a force-limited analysis and then compares the results to test data recovered during the CoNNeCT force-limited random vibration qualification test that took place at NASA Glenn Research Center (GRC) in the Structural Dynamics Laboratory (SDL) December 19, 2010 - January 7, 2011. A compilation of lessons learned and considerations for future force-limited tests is also included.

Staab, Lucas↗

Application of the Semi-Empirical Force-Limiting Approach for the CoNNeCT SCAN Testbed

The semi-empirical force-limiting vibration method was developed and implemented for payload testing to limit the structural impedance mismatch (high force) that occurs during shaker vibration testing. The method has since been extended for use in analytical models. The Space Communications and Navigation Testbed (SCAN Testbed), known at NASA as, the Communications, Navigation, and Networking re-Configurable Testbed (CoNNeCT), project utilized force-limiting testing and analysis following the semi-empirical approach. This paper presents the steps in performing a force-limiting analysis and then compares the results to test data recovered during the CoNNeCT force-limiting random vibration qualification test that took place at NASA Glenn Research Center (GRC) in the Structural Dynamics Laboratory (SDL) December 19, 2010 to January 7, 2011. A compilation of lessons learned and considerations for future force-limiting tests is also included.

Staab, Lucas D.↗

Capabilities of electrodynamic shakers when used for mechanical shock testing

The results of a research task to investigate the capabilities of electrodynamic vibrators (shakers) to perform mechanical shock tests are presented. The simulation method employed was that of developing a transient whose shock response spectrum matched the desired shock response spectrum. Areas investigated included the maximum amplitude capabilities of the shaker systems, the ability to control the shape of the resultant shock response spectrum, the response levels induced at frequencies outside the controlled bandwidth, and the nonlinearities in structural response induced by a change in test level.

Keegan, W. B.↗

Force Limited Vibration Testing Monograph

The practice of limiting the shaker force in vibration tests was instigated at the NASA Jet Propulsion Laboratory (JPL) in 1990 after the mechanical failure of an aerospace component during a vibration test.

Vibration↗

A method for experimental modal separation

A method is described for the numerical simulation of multiple-shaker modal survey testing using simulated experimental data to optimize the shaker force-amplitude distribution for the purpose of isolating individual modes of vibration. Inertia, damping, stiffness, and model data are stored on magnetic disks, available by direct access to the interactive FORTRAN programs which perform all computations required by this relative force amplitude distribution method.

Hallauer, W. L., Jr.↗

Force Limited Vibration Testing Monograph

The practice of limiting the shaker force in vibration tests was investigated at the NASA Jet Propulsion Laboratory (JPL) in 1990 after the mechanical failure of an aerospace component during a vibration test. Now force limiting is used in almost every major vibration test at JPL and in many vibration tests at NASA Goddard Space Flight Center (GSFC) and at many aerospace contractors. The basic ideas behind force limiting have been in the literature for several decades, but the piezo-electric force transducers necessary to conveniently implement force limiting have been available only in the last decade. In 1993, funding was obtained from the NASA headquarters Office of Chief Engineer to develop and document the technology needed to establish force limited vibration testing as a standard approach available to all NASA centers and aerospace contractors. This monograph is the final report on that effort and discusses the history, theory, and applications of the method in some detail.

Scharton, Terry D.↗

NASA Engineering and Safety Center Technical Bulletin No. 15-02: Best Practices for Use of Sine Burst Testing

Sine Burst (SB) Testing is used for strength testing of aerospace hardware as an alternate to static pull and centrifuge tests. The main advantage is that testing can be implemented while hardware is on the shaker for other tests. It also imposes a lower number of cycles on the hardware compared with a sine dwell or sweep, and is particularly suitable for relatively stiff components or electronics boxes, instruments, or spacecraft. Identified risks can be mitigated by best practices.

Best Practices↗