Search NASA⌕ Search

SEARCH · Search NASA

Results for “shield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Shielding application of perturbation theory to determine changes in neutron and gamma doses due to changes in shield layers

Perturbation theory formulas were derived and applied to determine changes in neutron and gamma-ray doses due to changes in various radiation shield layers for fixed sources. For a given source and detector position, the perturbation method enables dose derivatives with respect to density, or equivalently thickness, for every layer to be determined from one forward and one inhomogeneous adjoint calculation. A direct determination without the perturbation approach would require two forward calculations to evaluate the dose derivative due to a change in a single layer. Hence, the perturbation method for obtaining dose derivatives requires fewer computations for design studies of multilayer shields. For an illustrative problem, a comparison was made of the fractional change in the dose per unit change in the thickness of each shield layer in a two-layer spherical configuration as calculated by perturbation theory and by successive direct calculations; excellent agreement was obtained between the two methods.

Fieno, D.↗

01-07 Reactor Supplemental Shielding For the NRIC DOME Test Bed 01-07 Reactor Supplemental Shielding For the NRIC DOME Test Bed 2

A radiation shielding system is needed to protect personnel and equipment from harsh neutron and photon fluxes during: Reactor operations Post shut down operations Disassembly Decommissioning Examples of RSS driving requirements Radiological Controls Operating dose rate: the dose rate during normal reactor operations shall be <0.5 mrem/hr at the exterior wall of DOME containment Outdoor radiation limit: shielding shall provide the dose to a facility worker outside of DOME to <0.05 mrem/hr at 50 ft from the exterior wall of the DOME Temperature Reactors may have operating temperatures up to 800C The RSS shall be capable of removing up to 100 KW of heat during normal operating conditions the concrete structure has an upper temperature limit of 100°C

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of coated columbium alloy heat shields for space shuttle thermal protection system application. Volume 2, phase 2: Subsize heat shield and small size TPS evaluation

Initially a trade study was conducted of seven heat shield configurations. These were evaluated for structural reliability, fabricability, weight, inspectability, and refurbishability. Two concepts, a tee-stiffened and an open corrugation, were selected as offering the most potential for system success. Fourteen subsize heat shields of a full scale section were fabricated from C-129Y and Cb-752 and silicide coated with R-512E. These subsize panels were subjected to a simulated flight profile representing temperature, local surface pressures, and applied pressure differential loads. All corrugated panels of both alloys sustained 100 cycles without structural or coating failure. All Cb-752/R-512E panels performed well with one panel being successfully repaired after 66 cycles and completing 100 cycles. As a result of this evaluating the Cb-752/R-512E system was selected for hardware application during the subsequent phases. In addition, the tee-stiffened configuration was selected for further development and application in Phase III. This selection was based on an overall assessment of relative weight, cost, and structural performance of the tee-stiffened and open corrugation TPS.

Black, W. E.↗

Advanced Multifunctional MMOD Shield: Radiation Shielding Assessment

Deep space missions must contend with a harsh radiation environment Impacts to crew and electronics. Need to invest in multifunctionality for spacecraft optimization. MMOD shield. Goals: Increase radiation mitigation potential. Retain overall MMOD shielding performance.

Rojdev, Kristina↗

Dancoff-based Wigner-Seitz approximation for the subgroup resonance self-shielding in the VERA neutronic simulator MPACT

The MPACT neutronics module of the Virtual Environment for Reactor Analysis (VERA) has used the subgroup method for resonance self-shielding calculation, for which two-dimensional (2D) fixed-source transport calculations are performed using the method of characteristics for resonance energy groups. When considering thermal feedbacks, the subgroup calculation must be performed at each outer iteration. Therefore, the computing time for cross section processing is a significant burden for computational efficiency. The Dancoff-based Wigner-Seitz approximation (DWA) capability has been implemented into MPACT in conjunction with the subgroup method, which has been used in SCALE/XSProc since SCALE version 6.0 and has recently been called an equivalent Dancoff-factor cell (EDC) method. The issue of relatively large reactivity bias in DWA for the gadolinia rods was resolved by introducing multiple Dancoff factors. Benchmark results for the VERA pressurized and boiling water reactor benchmark suites show that the DWA capability would significantly enhance computational efficiency with comparable accuracy. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electrostatic design and conditioning of a triple point junction shield for a –200 kV DC high voltage photogun [Electrostatic design of a triple point junction shield for a -200 kV DC high voltage photogun using COMSOL]

Nuclear physics experiments performed at the Continuous Electron Beam Accelerator Facility (CEBAF) at the Jefferson Lab require a DC high voltage photogun to generate polarized electron beams from GaAs photocathodes. The photogun uses a tapered ceramic insulator that extends into the vacuum chamber and mechanically holds the cathode electrode. Increasing the operating voltage from nominal –130 kV to –200 kV will provide lower beam emittance, better transmission through injector apertures, and improved photocathode lifetime. This desire to increase the photogun operating voltage led to the design of a triple-point-junction shield electrode which minimizes the electric field at the delicate insulator-metal-vacuum interface and linearizes the potential across the insulator, thus reducing the risk of arcing along the ceramic insulator. Furthermore, this work describes the results obtained using COMSOL® electrostatic-field simulation software and presents the high voltage conditioning results of the upgraded –200 kV CEBAF photogun.

47 OTHER INSTRUMENTATION↗

Foam core shield (FCS) systems : a new dual - purpose technology for shielding against meteoroid strike damage and for thermal control of spacecrafts/satellite components

A new technology is being developed that can protect spacecraft and satellite components against damage from meteoroid strikes and control the thermal environment of the protected components. This technology, called Foam Core Shield (FCS) systems, has the potential to replace the multi-layer insulation blankets (MLI) that have been used on spacecraft for decades. In order to be an attractive candidate for replacing MLI, FCS systems should not only provide superior protection against meteoroid strikes but also provide an equal or superior ability to control the temperature of the protected component. Properly designed FCS systems can provide these principal functions, meteoroid strike protection and thermal control, with lower system mass and a smaller system envelope than ML.

thermal environment↗

Self-shielded, benchtop radio chemistry system with a plurality shielded carriers containing a disposable chip cassette

A self-shielded, bench-top radiochemistry system, including a radioactive isotope dispensing module configured to draw an isotope out of a vial and dispense one or more metered doses of the isotope to a concentration module that concentrates the metered dose into a droplet amount of isotope and a synthesizer module that delivers the droplet amount of isotope along with one or more reagents to an electrowetting on dielectrics (EWOD) chip to produce a radiolabeled molecule.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗