Search NASA⌕ Search

SEARCH · Search NASA

Results for “shielding design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electromagnetic simulation of helicon plasma antennas for their electrostatic shield design

A detailed electromagnetic parametric analysis of the helicon antenna (half Nagoya type) is shown at 13.56 MHz using a CST Microwave Studio 2012. The antenna is used to excite plasma inside a dielectric cylinder similar to a commercial reactor. Instead of focusing on the plasma state, the authors focus on the penetration and the three dimensional distribution of electric fields through the dielectric wall. Our aim is to reduce capacitive coupling which produces unwanted longitudinal and radial electric fields. Comparison of the helicon antenna electromagnetic performance under diverse boundary conditions shows that one is allowed to use vacuum simulations without plasma present in the cylinder, or approximate the plasma as a column of gyrotropic material with a tensor dielectric permittivity and with a sheath of a few millimeters in order to qualitatively predict the electric field distribution, thus avoiding a full plasma simulation. This way the analysis of the full problem is much faster and allows an optimal shield design. A detailed study of various shields shows that one can reduce the radial and axial fields by more than 1 order of magnitude compared to the unshielded antenna, while the azimuthal field is reduced only by a factor of 2. Optimal shield design in terms of pitch and spacing of openings is determined. Finally, an experimental proof of concept of the effect of shielding on reduced wall sputtering is provided, by monitoring the roughness created during oxygen plasma etching of an organic polymer.

42 ENGINEERING↗

A preliminary shield design for a SNAP-8 power system

A preliminary shield design for a nuclear power system utilizing a SNAP-8 reactor for space base application is presented. A representative space base configuration was selected to set the geometry constraints imposed on the design. The base utilizes two independent power packages each with a reactor operating at 600 kwt and each producing about 50 kwe. The crew compartment is located about 200 feet from each reactor and is large enough in extent to intercept a total shadow angle of 60 deg measured about the center line of each reactor.

Karp, I. M.↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

25 ENERGY STORAGE↗

Multifaceted Considerations for Fission Surface Power Radiation Shielding Design

The purpose of the Fission Surface Power (FSP) nuclear system is to provide energy on the Moon and Mars for supporting their exploration and colonization. The FSP design and deployment can leverage the past research and development work in areas, such as reactor design, but such crucial components as radiation shielding and instrumentation still need material and manufacturing studies, modeling, and testing. The shielding components are needed for the protection of humans, electronics, and sensitive components. They are essential system components, but they are often the heaviest components of the system for which each kilogram matters. Different material combinations and layouts are possible. The studies presented were focused on the evaluation of several options. The initial analysis included their performance assessment, initial temperature distribution evaluation and manufacturability considerations. Several feasible shield design options were identified and discussed in this paper, as well.

Fission Surface Power↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

Zhang, Bo↗

Observations Regarding Face Shield Designs Using Commonly Available Materials

A Sandia COVID-19 LDRD effort, the Sandia E-PiPEline Team, systematically evaluated design options for face shields constructed from commonly available materials (CAMs). This study is not focused on face shields for medical applications, and as such, has excluded labeling and flammability considerations suggested by the FDA. Design options for face shields were analyzed with subject matter expert input considering the design's effectiveness (seal around face), reusability (compatibility with solvents, degree of inertness), producibility (ability to obtain materials, build time), cost, and comfort (fit around head, contact surface interface). Observations for the design of face shields using CAMS are provided here.

59 BASIC BIOLOGICAL SCIENCES↗

Longwall shield design: is bigger better?

This article evaluates the bigger is better design philosophy for longwall shields. The conventional support design approach based on simplistic models of supporting the full dead weight detached rock masses is replaced by a ground reaction design approach. Here, the goal is to match the support characteristics to the ground response, and not to try and overpower the ground forces with some massive support capability. The ground reaction concept embodies both the force and displacement controlled loading aspects, and therefore provides a more accurate representation of the support loading requirements. 7 figs.

01 COAL, LIGNITE, AND PEAT↗

SU-E-T-474: Improvements to Intra-Oral Shield Design for Electron Beam Treatments: Use of Multi-Layered Metal Foils

Purpose: Intraoral electron shields used in radiotherapy are designed to minimize radiation exposure to non-treatment tissue. Sites where shields are used include but are not limited to, the treatment of lips, cheeks and ears whilst shielding the underlying oral cavity, tongue, gingival or temporal region. However their use produces an enhancement in dose on the beam side caused by an increase in electron backscatter radiation. This work designs a new shield incorporating copper, aluminium and wax in a step down filter arrangement to minimise backscatter whilst minimizing overall shield thickness. Methods: For electron beams ranging from 6 MeV to 10 MeV, shields of varying designs and thicknesses were assessed to determine the thinnest shield design that could be produced whilst minimising backscattered radiation to a clinically acceptable level. This was performed with conventional lead and wax shields as well as varying quantities of aluminium and copper foils. Results: From tested shield designs, a new shield design of 4 mm lead, 0.6 mm copper, 1.0 mm aluminium and 1.5 mm wax (3.1 mm added filtration, 7.1 mm total thickness) provided a clinically acceptable (no greater than 110% dose) backscatter and transmission reduction and matched a standard 4.5 mm lead and 10 mm wax (total thickness 14.5 mm) electron shield. Dose enhancement values of no more than 10 % were measured utilising this shield design with a 50 % reduction in shield thickness. Conclusion: The thinner layered shield reduced backscattered radiation dose to less than 10% enhancement for beam energies on 10 MeV and less and will allow easier patient set up. The thinner shields are tolerated better by patients when mucosal reactions occur as they place less physical pressure on these sites during treatment due to their smaller size and thickness.

60 APPLIED LIFE SCIENCES↗

Local Radiation Shielding Design Methodology

The NSLS-II accelerators are housed within a radiation enclosure of normal concrete (and in some places high density concrete) that has been designed to reduce the radiation generated from an assumed operational beam loss or bulk shielding current (BCS) from each accelerator. The beam loss model used to estimate the thickness of this bulk shielding, assumed a beam energy at the expected operating energy and a current loss based on reasonable assumptions for the fraction of the expected operating current. The thickness of the shield was determined to be the amount required to reduce the radiation outside the shield to a maximum dose rate of <0.5mrem/hr. for occupied areas for these normal operational losses. These assumed beam losses and the bulk shielding thicknesses required are given in reference [1]. Abnormal operating conditions generating higher than normal beam losses must also be considered, and additional engineering controls will be required depending on the magnitude of the radiation levels generated during the abnormal condition. Additional local shielding subject to configuration control may be utilized to reduce radiation levels associated with these abnormal loss conditions. Interlocked area radiation monitors are another means to prevent continued operation with higher than an acceptable level. The NSLS-II Shielding Policy requires that an engineered system be utilized to mitigate an abnormal condition producing radiation levels greater than 100 mR/h, and that two systems are required if the projected radiation levels during a fault condition are > 2000 mR/h. It is intended that shielding limits the dose rate to < 0.5 mR/h in occupied areas for normal operational losses, and the combination of administrative and engineered controls for abnormal losses will maintain radiation exposure to trained personnel working at the NSLS-II facility to as low as reasonably achievable. It is anticipated that all individual exposures will be well within the planned administrative control level of 100mrem/year. This technical note presents the method used to identify these potential high beam loss locations, evaluate the potential radiation risk these losses create outside the enclosure shield and the design process that specifies the required local radiation shielding needed to reduce this risk below the maximum dose rate of the bulk shield design, listed above. If shielding can’t be adequately provided or if other fault initiated losses could occur, then the necessary engineering controls will be indicated that will limit the energy, current or duration of the beam transport that constitute this high beam loss risk.

36 MATERIALS SCIENCE↗

Monte Carlo Studies for the Radiation Shielding Design of LCLS-II

Intensive Monte Carlo simulations performed with state-of-the-art computation codes are applied to the radiation shielding design of LCLS-II, which will be the extension of Linac Coherent Light Source (LCLS) at SLAC and will use the middle one-third of SLAC two-mile Linac. This paper describes the Monte Carlo studies of the first and last system where electron beams are involved, namely the LCLS-II Injector and the X-ray Transport and Diagnostics System (XTOD).

43 PARTICLE ACCELERATORS↗

Standardized Radiation Shield Design Methods: 2005 HZETRN

Research committed by the Langley Research Center through 1995 resulting in the HZETRN code provides the current basis for shield design methods according to NASA STD-3000 (2005). With this new prominence, the database, basic numerical procedures, and algorithms are being re-examined with new methods of verification and validation being implemented to capture a well defined algorithm for engineering design processes to be used in this early development phase of the Bush initiative. This process provides the methodology to transform the 1995 HZETRN research code into the 2005 HZETRN engineering code to be available for these early design processes. In this paper, we will review the basic derivations including new corrections to the codes to insure improved numerical stability and provide benchmarks for code verification.

Wilson, John W.↗

Verification of the prompt radiation shielding design of the ESS Accelerator (Stage 2)

The purpose of this CRADA is to perform additional analyses using MARS Monte-Carlo calculations code for verification of the prompt radiation shielding design of the ESS Accelerator. Stage 2 includes the following activities: 1.Activation assessment of the soil surrounding the wall of the ESS accelerator that maymigrate with the groundwater 2.Shielding assessment of the HVAC exhaust duct The existing ESS accelerator model (with possible minor modifications) shall be used in calculations. This work builds on the analysis originally performed under agreement CRADA FRA-2015-0302.

43 PARTICLE ACCELERATORS↗

Magnetic Shield Design Modeling and Validation on SWOT Spacecraft Applied to Mars Flux Pinning Orbiting Sample Design

A modeling methodology was developed for use on the Surface Water and Ocean Topography (SWOT) mission for the computational modeling and design of a magnetic shield for a 63 A-sq m source. Shield options were modeled and tested across various design parameters and validated with measurement. Measurement results fell within 10% of simulation in most cases of concern with sources of error well understood. These methods results informed a subsequent modeling activity for a future Mars Sample Return (MSR) mission concept with stringent magnetic cleanliness requirements to retain geologic integrity of the samples. One option for capturing the sample from orbit requires rare earth magnets in close proximity to the Martian samples. Magnetic modeling with a finite-element method solver estimated the magnetic environment and established the need for shielding. Further modeling then determined the shielding necessary to meet magnetic requirements, followed by the design of a mass-optimized solution.

Gonzales, Edward↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shielding Design for Prototype Generation-IV Sodium-Cooled Fast Reactor

A Prototype Generation-IV Sodium-cooled Fast Reactor (PGSFR) with 150 MWe power rating is being developed jointly by the Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL). KAERI is responsible for the overall project with the ANL contributions integrated into the KAERI activities. Shielding concept of PGSFR was developed to ensure that the safety limit on internal structural damage and working personnel received dose is not exceeded. The first part evaluated the Displacement Per Atoms (DPA) and fast neutron fluence on the structures inside the reactor vessel, such as lower grid, Upper Internal Structure (UIS), barrel, Redan, and reactor vessels. The analysis determined the thickness of shields required to satisfy the DPA and fast fluence limit. The second part of the shielding analysis evaluated the radiation dose rate above the reactor head due to the primary sodium activation inside the reactor vessel. The analysis determined the necessary thickness of reactor head and additional shield to ensure that the dose rate received by personnel working on top of the reactor is below the safety limit. The last part of the shielding analysis investigated the dose rate received by personnel working near the secondary loop. The secondary sodium is activated inside the Intermediate heat exchanger (IHX). The activated secondary sodium flows out of the reactor vessel and emits high energy photons along the way. The shielding designs both inside the reactor vessel and around the pipes of the secondary loop were investigated. The shielding concept for the PGSFR was developed to minimize radiation exposure to plant personnel and the irradiation damage of the internal structural components. The damage of the internal structural components are mainly due to the loss of the ductility by the neutron irradiation, and the activated gammas of primary and secondary sodium coolants are the major radiation sources that are required to be shielded. Thicker and denser shielding structures are favorable to reduce the radiation dose and protect personnel who work in the plant; however, which enlarges the in-vessel space to accommodate the shielding structures. Thus, in order to install the shielding structures in a reasonable reactor to satisfy the DPA or dose rate limit size, the PGSFR shielding parameters were determined from the sensitivity study, which includes the compositions of the shielding materials and dimensions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Accelerator shield design of KIPT neutron source facility

Argonne National Laboratory (ANL) of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of a neutron source facility at KIPT utilizing an electron-accelerator-driven subcritical assembly. Electron beam power is 100 kW, using 100 MeV electrons. The facility is designed to perform basic and applied nuclear research, produce medical isotopes, and train young nuclear specialists. The biological shield of the accelerator building is designed to reduce the biological dose to less than 0.5-mrem/hr during operation. The main source of the biological dose is the photons and the neutrons generated by interactions of leaked electrons from the electron gun and accelerator sections with the surrounding concrete and accelerator materials. The Monte Carlo code MCNPX serves as the calculation tool for the shield design, due to its capability to transport electrons, photons, and neutrons coupled problems. The direct photon dose can be tallied by MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is less than 0.01 neutron per electron. This causes difficulties for Monte Carlo analyses and consumes tremendous computation time for tallying with acceptable statistics the neutron dose outside the shield boundary. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were developed for the study. The generated neutrons are banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron and secondary photon doses. The weight windows variance reduction technique is utilized for both neutron and photon dose calculations. Two shielding materials, i.e., heavy concrete and ordinary concrete, were considered for the shield design. The main goal is to maintain the total dose outside the shield boundary at less than 0.5-mrem/hr. The shield configuration and parameters of the accelerator building have been determined and are presented in this paper. (authors)

43 PARTICLE ACCELERATORS↗