Search NASA⌕ Search

SEARCH · Search NASA

Results for “shifter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spin waves excitation at micron-sized, anisotropy modified regions in amorphous Fe 80 B 20 stripes: Local properties and inter-regions coupling

We report on the measurement of the local magnetization dynamics occurring, at units of GHz, in large aspect ratio stripes lithographed from reduced damping amorphous Fe 80 B 20 films. The stripes were submitted to local anisotropy modifications by micrometric beam synchrotron X-ray irradiation. Our results include data on the dispersion relationships and group velocities corresponding to spin waves excited at both the non-irradiated and the irradiated regions. Whereas in the former case we observed standing spin waves with transverse-to-the stripe axis wave vector, in the latter one, for which the wave vector of the spin waves was parallel-to-the stripe axis, propagating spin waves were excited. In both regions, we measured the effective propagation distance of the spin waves, which resulted to be independent of the wave vector orientation. In the spin waves excited at the irradiated region, we also measured the decay time and effective damping coefficient, which was in good agreement with previously reported values obtained from FMR measurements in amorphous Fe 80 B 20 continuous films. We show that the interaction of the non-irradiated and irradiated zones results, at the stripe transverse saturation remanence and under an exciting field frequency of 4 GHz, in the introduction of a π phase shift between the standing spin waves excited at both sides of the irradiated region. This result opens the possibility of using the local, transverse to the stripe axis, magnetic anisotropy easy axis induced by the X-ray irradiation as a crucial constituent of a zero-applied field spin wave phase-shifter.

36 MATERIALS SCIENCE↗

Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector

To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and 0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. In order to bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. Overall, this enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tapered helical undulator system for high efficiency energy extraction from a high brightness electron beam

In this work we discuss the design choices and construction strategy of the tapered undulator system designed for a high energy extraction efficiency experiment in the ultraviolet region of the electromagnetic spectrum planned for installation at the Argonne National Laboratory Linac Extension Area (LEA) beamline. The undulator is comprised of 4 sections pure permanent magnet Halbach array separated by short break sections, each one of them housing a focusing quadrupole doublet and a phase shifter. The quadrupoles use a novel hybrid design which allows one to vary the gradient and match the beam transversely. Finally, the undulator tapering profile is optimized to maximize the energy conversion efficiency from a 340 MeV 1 kA beam into coherent 257.5 nm radiation taking into account the longitudinal current profile generated by the linac.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polysiloxane Scintillators for Efficient Neutron and Gamma-Ray Pulse Shape Discrimination

Plastic scintillators based on thermoplastics, such as polystyrene and poly(vinyl toluene) (PVT), are capable of neutron and γ radiation detection via pulse shape discrimination (PSD) when overdoped with select fluorescent molecules. This class of plastic scintillator has been extensively studied but is limited to applications suitable for thermoplastics. For applications requiring flexibility, scintillators composed of elastomers, such as polysiloxanes, offer an alternative to PVT scintillators. Polysiloxane scintillators are inherently flexible and have a short processing time on the order of 3 h in air and equivalent or better detection capability at reduced doping concentration (<5 wt %). This work presents polysiloxane-based scintillators, containing only 1–5 wt % of 2,5 diphenyl-oxazole (PPO) or 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) as primary dopants and 9,9-dimethyl-2,7-distyryl-9H-fluorene (SFS) as a wavelength shifter. A 5 wt % PPO polysiloxane sample had improved neutron and gamma ray PSD and comparable light yield than EJ-299-33 tested under the same conditions, i.e., figure of merit (FoM) of 1.33 ± 0.03 at 450 keV ee and light yield of 94% relative to EJ-299-33. The 5 wt % PhF-polysiloxane sample had a higher light yield, 144% of EJ-299-33 but lower FoM under the same conditions (FoM of 1.09 ± 0.03). Furthermore, this work highlights the potential of polysiloxanes as a matrix for PSD capable plastic scintillators.

36 MATERIALS SCIENCE↗

Synchronous micromechanically resonant programmable photonic circuits

Abstract Programmable photonic integrated circuits (PICs) are emerging as powerful tools for control of light, with applications in quantum information processing, optical range finding, and artificial intelligence. Low-power implementations of these PICs involve micromechanical structures driven capacitively or piezoelectrically but are often limited in modulation bandwidth by mechanical resonances and high operating voltages. Here we introduce a synchronous, micromechanically resonant design architecture for programmable PICs and a proof-of-principle 1×8 photonic switch using piezoelectric optical phase shifters. Our design purposefully exploits high-frequency mechanical resonances and optically broadband components for larger modulation responses on the order of the mechanical quality factor Q m while maintaining fast switching speeds. We experimentally show switching cycles of all 8 channels spaced by approximately 11 ns and operating at 4.6 dB average modulation enhancement. Future advances in micromechanical devices with high Q m , which can exceed 10000, should enable an improved series of low-voltage and high-speed programmable PICs.

42 ENGINEERING↗

Millimeter-wave dielectric tunability driven by topological polar structure switching in PbTiO 3 /SrTiO 3 superlattices

Dielectric tunability induced by an external electric field in materials underpins radio frequency signal modulation devices such as phase shifters, which are critical components in wireless communication and sensing systems. However, the tunability and integrability of current devices have yet to be enhanced for emerging applications, particularly at millimeter-wave frequencies. Here, we demonstrate that topological polar structures formed in PbTiO 3 /SrTiO 3 superlattices exhibit large tunable in-plane dielectric properties, as determined by their multiscale structural configurations and polarization switching behaviors. Under a moderate field of 30 kV cm −1 , the dipole wave structure maintains a tunability exceeding 15% at 70 GHz and above 8% over the measured range up to 110 GHz, contrasting with the weakly tunable flux closure structure. Based on in situ structural characterizations and molecular dynamics simulations, we delineate the polarization switching processes and elucidate the mechanisms underlying the observed tunable millimeter-wave dielectric responses. Our results provide new insights into the high-frequency dielectric properties of topological polar phases, potentially broadening the versatility of these materials in next-generation integrated electronic applications.

36 MATERIALS SCIENCE↗

Heisenberg-limited Hamiltonian learning for interacting bosons

We develop a protocol for learning a class of interacting bosonic Hamiltonians from dynamics with Heisenberg-limited scaling. For Hamiltonians with an underlying bounded-degree graph structure, we can learn all parameters with root mean square error ϵ using ${\mathcal{O}}(1/\epsilon )$ total evolution time, which is independent of the system size, in a way that is robust against state-preparation and measurement error. In the protocol, we only use bosonic coherent states, beam splitters, phase shifters, and homodyne measurements, which are easy to implement on many experimental platforms. A key technique we develop is to apply random unitaries to enforce symmetry in the effective Hamiltonian, which may be of independent interest.

computer science↗

High-speed programmable photonic circuits in a cryogenically compatible, visible–near-infrared 200 mm CMOS architecture

Abstract Recent advances in photonic integrated circuits have enabled a new generation of programmable Mach–Zehnder meshes (MZMs) realized by using cascaded Mach–Zehnder interferometers capable of universal linear-optical transformations on N input/output optical modes. MZMs serve critical functions in photonic quantum information processing, quantum-enhanced sensor networks, machine learning and other applications. However, MZM implementations reported to date rely on thermo-optic phase shifters, which limit applications due to slow response times and high power consumption. Here we introduce a large-scale MZM platform made in a 200 mm complementary metal–oxide–semiconductor foundry, which uses aluminium nitride piezo-optomechanical actuators coupled to silicon nitride waveguides, enabling low-loss propagation with phase modulation at greater than 100 MHz in the visible–near-infrared wavelengths. Moreover, the vanishingly low hold-power consumption of the piezo-actuators enables these photonic integrated circuits to operate at cryogenic temperatures, paving the way for a fully integrated device architecture for a range of quantum applications.

47 OTHER INSTRUMENTATION↗

Phase estimation algorithm for the multibeam optical metrology

Unitary Fourier transform lies at the core of the multitudinous computational and metrological algorithms. Here we show experimentally how the unitary Fourier transform-based phase estimation protocol, used namely in quantum metrology, can be translated into the classical linear optical framework. The developed setup made of beam splitters, mirrors and phase shifters demonstrates how the classical coherence, similarly to the quantum coherence, poses a resource for obtaining information about the measurable physical quantities. Our study opens route to the reliable implementation of the small-scale unitary algorithms on path-encoded qudits, thus establishing an easily accessible platform for unitary computation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highly efficient photon detection systems for noble liquid detectors based on perovskite quantum dots

Abstract Wavelength shifting photon detection systems (PDS) are the critical functioning components in noble liquid detectors used for high energy physics (HEP) experiments and dark matter search. The vacuum ultraviolet (VUV) scintillation light emitted by these Liquid argon (LAr) and liquid Xenon (LXe) detectors are shifted to higher wavelengths resulting in its efficient detection using the state-of-the-art photodetectors such as silicon photomultipliers (SiPM). The currently used organic wavelength shifting materials [such as 1,1,4,4 Tetraphenyl Butadiene (TPB)] have several disadvantages and are unreliable for longterm use. In this study, we demonstrate the application of the inorganic perovskite cesium lead bromide (CsPbBr 3 ) quantum dots (QDs) as highly efficient wavelength shifters. The absolute photoluminescence quantum yield of the PDS fabricated using these QDs exceeds 70%. CsPbBr 3 -based PDS demonstrated an enhancement in the SiPM signal enhancement by up to 3 times when compared to a 3 µm-thick TPB-based PDS. The emission spectrum from the QDs was optimized to match the highest quantum efficiency region of the SiPMs. In addition, we have demonstrated the deposition of the QD-based wavelength shifting material on a large area PDS substrate using low capital cost and widely scalable solution-based techniques providing a pathway appropriate for meter-scale PDS fabrication and widespread use for other wavelength shifting applications.

47 OTHER INSTRUMENTATION↗

Spin wave interference detection via inverse spin Hall effect

Here, in this Letter, we present experimental data that demonstrate a spin wave interference detection using an inverse spin Hall effect (ISHE). Two coherent spin waves are excited in a yttrium-iron garnet waveguide by continuous microwave signals. The initial phase difference between the spin waves is controlled by the external phase shifter. The ISHE voltage is detected at a distance of 2 and 4 mm away from the spin wave generating antennas by an attached Pt layer. Experimental data show ISHE voltage oscillation as a function of the phase difference between the two interfering spin waves. This experiment demonstrates an intriguing possibility of using ISHE in a spin wave logic circuit converting a spin wave phase into an electric signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Piezo-optomechanical cantilever modulators for VLSI visible photonics

Visible-wavelength very large-scale integration photonic circuits have a potential to play important roles in quantum information and sensing technologies. The realization of scalable, high-speed, and low-loss photonic mesh circuits depends on reliable and well-engineered visible photonic components. Here, we report a low-voltage optical phase shifter based on piezo-actuated mechanical cantilevers, fabricated on a CMOS compatible, 200 mm wafer-based visible photonics platform. We show linear phase and amplitude modulation with 6 V π cm in differential operation, −1.5 to −2 dB insertion loss, and up to 40 dB contrast in the 700–780 nm range. By adjusting selected cantilever parameters, we demonstrate a low-displacement and a high-displacement device, both exhibiting a nearly flat frequency response from DC to a peak mechanical resonance at 23 and 6.8 MHz respectively, which, through resonant enhancement of Q ∼ 40, further decreases the operating voltage down to 0.15 V π cm.

Dong, Mark↗

Acousto-optic modulators for fibre-optic lines

The specific features of efficient matching of acousto-optic devices with single-mode fibres for the cases of isotropic and anisotropic diffraction are considered. The acousto-optic interaction geometry, optimal for modulating an arbitrarily polarised light beam with a possibility of tuning its frequency shift in the range up to ∼10 MHz, is chosen. Acousto-optic modulators/frequency shifters based on paratellurite (TeO{sub 2}), pigtailed with polarisation-maintaining and non-polarisation-maintaining fibres, have been developed for wavelengths of 1064 and 1550 nm, and their main technical parameters are investigated. (paper)

36 MATERIALS SCIENCE↗

Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

A sub-picosecond digitally-controlled phase delay

The use of precision timing measurements will be a major tool at the HL-LHC, where it will be used to suppress pile-up and to search for long-lived particles. To control a reference clock with sub-picosecond accuracy, we have fabricated in the TSMC 65 nm process a digitally controlled phase shifter. It is composed of a chain of 66 cells, each with a digitally controlled planar wave guide with either a short or long delay. With this a reference clock’s phase can be controlled to a precision of 200 fs with dynamic range of 12 ps.

Instruments & Instrumentation↗