Numerical Simulation and Analytical Study of Instability Growth in Solids
No abstract prepared.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
High temperature polar polymers have demonstrated potential for good thermal stability and high dielectric constant at the same time. However, polarization of contaminated impurity ions in polar polymers, even at the ppm level, can significantly increase the dielectric loss at high temperature and low frequencies. One effective strategy to mitigate this problem is to multilayer them with a high temperature nonpolar dielectric polymer to confine impurity ion transport at the nanometer scale. In this study, confined ion transport in high temperature polycarbonate (HTPC)/poly(vinylidene fluoride) (PVDF) multilayer films under high AC electric fields was studied using a direct analytical simulation method. Different from the ion transport under low fields, the ion diffusion model failed to describe the ion transport under high electric fields. An exponential ion distribution profile, which was observed for the DC poling situation, was employed to implement the direct analytical simulation. Confined impurity ion transport under high AC fields was quantitatively understood. As the AC field increased, the mobile ion concentration decreased whereas the diffusion coefficient increased. The decrease of mobile ion concentration was explained by the blockage of impurity ions by the HTPC layers. This knowledge helped in the determination of optimal conditions to polarize impurity ions from the PVDF layers into the HTPC layers. After cooling below the glass transition temperature of HTPC, polarized impurity ions were locked inside the HTPC layers. As a result, increased discharge efficiency and enhanced electrical insulation (i.e., increased dielectric breakdown strength) were achieved for the polarized multilayer films.
Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicated image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30°, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at ∼0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as incorporated in the forward- and back-projection steps. Meanwhile, the developed MC model and the analytical simulator of the system can be applied for further studies on development and evaluation of the system.
We present an ongoing work in which a surrogate model is being developed to reproduce the response dynamics of the third-integer resonant extraction process in the Delivery Ring (DR) at Fermilab. This is in pursuit of smoothly extracting circulating beam to the Mu2e Experiment’s production target, whereby the goal is to extract a uniform slice of the circulating 1e12 protons in the DR over 25,000 turns (43 ms). The DR contains 3 harmonic sextupoles that excite a third-integer resonance and three fast, tune-ramping quadrupole magnets that drive the horizontal tune towards the 29/3 resonance. In our initial work, the surrogate model trains on a semi-analytical simulation provided in the same format as live data. Using Reinforcement Learning (and other potential ML methods), the trained surrogate acts as the “environment” in which a simple ML control agent could learn to dynamically adjust the quadrupole ramp at 430 break points within the 43 microsecond spill window. The controller will be hosted on a dedicated Arria 10 FPGA. In this work, we report the accuracy and fidelity of the surrogate model in comparison to the response dynamics of the physics simulator.
Not Available
Not provided.
The purpose of this work was to quantify the effects of scatter for inverse-geometry dedicated breast CT compared to cone-beam breast CT through simulations. The inverse geometry was previously proposed as an alternative to cone-beam acquisition for volumetric CT. The inverse geometry consists of a large-area scanned-source opposite a detector array that is smaller in the transverse direction. While the gantry rotates, the x-ray beam is rapidly sequenced through an array of positions, acquiring a truncated projection image at each position. Inverse-geometry CT (IGCT) is expected to detect less scatter than cone-beam methods because only a fraction of the object is irradiated at any time and the fast detector isolates the measurements from sequential x-ray beams. An additional scatter benefit is the increased air gap due to the inverted geometry. In this study, we modeled inverse-geometry and cone-beam dedicated breast CT systems of equivalent resolution, field of view, and photon fluence. Monte Carlo simulations generated scatter and primary projections of three cylindrical phantoms of diameters 10, 14, and 18 cm composed of 50% adipose/50% glandular tissue. The scatter-to-primary ratio (SPR) was calculated for each breast diameter. Monte Carlo simulations were combined with analytical simulations to generate inverse-geometry and cone-beam images of breast phantoms embedded with tumors. Noise representing the photon fluence of a realistic breast CT scan was added to the simulated projections. Cone-beam data were reconstructed with and without an ideal scatter correction. The CNR between breast tumor and background was compared for the inverse and cone-beam geometries for the three phantom diameters. Results demonstrated an order of magnitude reduction in SPR for the IGCT system compared to the cone-beam system. For example, the peak IGCT SPRs were 0.05 and 0.09 for the 14 and 18 cm phantoms, respectively, compared to 0.42 and 1 for the cone-beam system. For both geometries, the effects of scatter on contrast-to-noise ratio (CNR) were small for the 10 cm diameter phantom. The inverse-geometry improved the CNR by factors of 1.16 for the 14 cm phantom and 1.48 for the 18 cm phantom compared to a cone-beam acquisition without scatter correction. When an ideal scatter correction was applied to the cone-beam acquisition, the IGCT CNR improvements were 1.03 and 1.25 for the 14 and 18 cm phantoms. Overall, the results suggest that the inverse geometry may be advantageous for dedicated breast CT, an application that requires high-contrast resolution, spatial resolution, and dose efficiency.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Purpose: To investigate the feasibility of characterizing the chemical composition of breast tissue, in terms of water and lipid, by using spectral mammography in simulation and postmortem studies. Methods: Analytical simulations were performed to obtain low- and high-energy signals of breast tissue based on previously reported water, lipid, and protein contents. Dual-energy decomposition was used to characterize the simulated breast tissue into water and lipid basis materials and the measured water density was compared to the known value. In experimental studies, postmortem breasts were imaged with a spectral mammography system based on a scanning multi-slit Si strip photon-counting detector. Low- and high-energy images were acquired simultaneously from a single exposure by sorting the recorded photons into the corresponding energy bins. Dual-energy material decomposition of the low- and high-energy images yielded individual pixel measurements of breast tissue composition in terms of water and lipid thicknesses. After imaging, each postmortem breast was chemically decomposed into water, lipid and protein. The water density calculated from chemical analysis was used as the reference gold standard. Correlation of the water density measurements between spectral mammography and chemical analysis was analyzed using linear regression. Results: Both simulation and postmortem studies showed good linear correlation between the decomposed water thickness using spectral mammography and chemical analysis. The slope of the linear fitting function in the simulation and postmortem studies were 1.15 and 1.21, respectively. Conclusion: The results indicate that breast tissue composition, in terms of water and lipid, can be accurately measured using spectral mammography. Quantitative breast tissue composition can potentially be used to stratify patients according to their breast cancer risk.
Purpose: To quantify the accuracy in predicting the Bragg peak position using simulated in-room measurements of prompt gamma (PG) emissions for realistic treatment error scenarios that combine several sources of errors. Methods: Prompt gamma measurements by a knife-edge slit camera were simulated using an experimentally validated analytical simulation tool. Simulations were performed, for 143 treatment error scenarios, on an anthropomorphic phantom and a pencil beam scanning plan for nasal cavity. Three types of errors were considered: translation along each axis, rotation around each axis, and CT-calibration errors with magnitude ranging respectively, between −3 and 3 mm, −5 and 5 degrees, and between −5 and +5%. We investigated the correlation between the Bragg peak (BP) shift and the horizontal shift of PG profiles. The shifts were calculated between the planned (reference) position and the position by the error scenario. The prediction error for one spot was calculated as the absolute difference between the PG profile shift and the BP shift. Results: The PG shift was significantly and strongly correlated with the BP shift for 92% of the cases (p<0.0001, Pearson correlation coefficient R>0.8). Moderate but significant correlations were obtained for all cases that considered only CT-calibration errors and for 1 case that combined translation and CT-errors (p<0.0001, R ranged between 0.61 and 0.8). The average prediction errors for the simulated scenarios ranged between 0.08±0.07 and 1.67±1.3 mm (grand mean 0.66±0.76 mm). The prediction error was moderately correlated with the value of the BP shift (p=0, R=0.64). For the simulated scenarios the average BP shift ranged between −8±6.5 mm and 3±1.1 mm. Scenarios that considered combinations of the largest treatment errors were associated with large BP shifts. Conclusion: Simulations of in-room measurements demonstrate that prompt gamma profiles provide reliable estimation of the Bragg peak position for complex error scenarios. Yafei Xing and Luiza Bondar are funded by BEWARE grants from the Walloon Region. The work presents simulations results for a prompt gamma camera prototype developed by IBA.
The formation, evolution, and detailed structure of accretion disks remain poorly understood, with wide implications across a variety of astrophysical disciplines. While the most pressing question – what causes the high angular momentum fluxes that are necessary to explain observations? – is nicely answered by the idea that the disk is turbulent, a more complete grasp of the fundamental processes is necessary to capture the wide variety of behaviors observed in the night sky. This thesis studies the turbulence in ionized accretion disks from a theoretical standpoint, in particular focusing on the generation of magnetic fields in these processes, known as dynamo. Such fields are expected to be enormously important, both by enabling the magnetorotational instability (which evolves into virulent turbulence), and through large-scale structure formation, which may transport angular momentum in different ways and be fundamental for the formation of jets. The central result of this thesis is the suggestion of a new large-scale dynamo mechanism in shear flows – the “magnetic shear-current effect” – which relies on a positive feedback from smallscale magnetic fields. As well as being a very promising candidate for driving field generation in the central regions of accretion disks, this effect is interesting because small-scale magnetic fields have historically been considered to have a negative effect on the large-scale dynamo, damping growth and leading to dire predictions for final saturation amplitudes. Given that small-scale fields are ubiquitous in plasma turbulence above moderate Reynolds numbers, the finding that they could instead have a positive effect in some situations is interesting from a theoretical and practical standpoint. The effect is studied using direct numerical simulation, analytic techniques, and novel statistical simulation methods. In addition to the dynamo, much attention is given to the linear physics of disks and its relevance to turbulence. This is studied using nonmodal stability theory, which both provides a highly intuitive connection between global domains and the commonly studied shearing box, and suggests that transient linear growth can often be more important than spectral instability. These realizations motivate the use of the quasi-linear models that are applied extensively throughout the turbulence and dynamo studies later in the thesis.
The wettability of graphitic carbon and silicon surfaces was numerically and theoretically investigated. A multi-response method has been developed for the analysis of conventional molecular dynamics (MD) simulations of droplets wettability. The contact angle and indicators of the quality of the computations are tracked as a function of the data sets analyzed over time. This method of analysis allows accurate calculations of the contact angle obtained from the MD simulations. Analytical models were also developed for the calculation of the work of adhesion using the mean-field theory, accounting for the interfacial entropy changes. A calibration method is proposed to provide better predictions of the respective contact angles under different solid-liquid interaction potentials. Estimations of the binding energy between a water monomer and graphite match those previously reported. In addition, a breakdown in the relationship between the binding energy and the contact angle was observed. The macroscopic contact angles obtained from the MD simulations were found to match those predicted by the mean-field model for graphite under different wettability conditions, as well as the contact angles of Si(100) and Si(111) surfaces. Finally, an assessment of the effect of the Lennard-Jones cutoff radius was conducted to provide guidelines for future comparisons between numerical simulations and analytical models of wettability.
An improved electrical contact resistance (ECR) model for elastic rough electrode contact is proposed, incorporating the effects of asperity interactions and temperature rise by frictional and joule heating. The analytical simulation results show that the ECR decreases steeply at the beginning of the contact between Al and Cu. However, it becomes stabilized after reaching a specific contact force. It is also found that the longer elapsed sliding contact time, the higher ECR due to the increase in electrical resistivity of electrode materials by the frictional temperature rise at the interface. The effects of surface roughness parameters on ECR are studied through the 3 2 full-factorial design-of-experiment analysis. Based on the two representative roughness parameters, i.e., root-mean-square (rms) roughness and asperity radius, their individual and coupled effects on the saturated ECR are examined. The saturated ECR increases with the rms roughness for a rough machined surface condition, but it is hardly affected by the asperity radius. On the other hand, the saturated ECR increases with both the rms roughness and the asperity radius under a smooth thin film surface condition.
A series of batch contact tests were conducted to evaluate the exchange behavior of Ba, Ca, Pb, and Sr onto crystalline silicotitanate (CST) in support of an expedited Cs removal and pretreatment system at the Hanford site. Binary Na/M 2+ and ternary Na/Cs/M 2+ isotherms were generated to understand selectivity, capacity, and competitive impact of each analyte on Cs uptake from a simple 1 M NaOH/4.6 M NaNO 3 simulant. Analyte loading from a 0.1 M NaOH/5.5 M NaNO 3 simulant was assessed to determine the effect of hydroxide concentration on binary Na/M 2+ isotherms. Finally, results from binary and ternary isotherms indicated that group II metals, and Pb do not impact CST performance toward CST at concentrations expected in Hanford tank waste supernate.
Thickness dependent photocurrent density in active layer of graphene/Si based solar cell has been investigated via analytical – simulation study. This report is a preliminary comparison of experimental and analytical investigation of graphene/Si based solar cell. Graphene sheet was interfaced with Si thin film forming heterojunction solar cell that was treated as a device model for photocurrent generator. Such current can be enhanced by optimizing active layer thickness and involving metal oxide as supporting layer to shift photons absorption. In this case there are two type of devices model with and without TiO{sub 2} in which the silicon thickness varied at 20 – 100 nm. All of them have examined and also compared with each other to obtain an optimum value. From this calculation it found that generated currents almost linear with thickness but there are saturated conditions that no more enhancements will be achieved. Furthermore TiO{sub 2} layer is effectively increases photon absorption but reducing device stability, maximum current is fluctuates enough. This may caused by the disturbance of excitons diffusion and resistivity inside each layer. Finally by controlling active layer thickness, it is quite useful to estimate optimization in order to develop the next solar cell devices.
In this paper, we examine the behaviour of basic autocatalytic feedback modules involving a species catalyzing its own production, either directly or indirectly. We first perform a systematic study of the autocatalytic feedback module in isolation, examining the effect of different factors, showing how this module is capable of exhibiting monostable threshold and bistable switch-like behaviour. We then study the behaviour of this module embedded in different kinds of basic networks including (essentially) irreversible cycles, open and closed reversible chains, and networks with additional feedback. We study the behaviour of the networks deterministically and also stochastically, using simulations, analytical work, and bifurcation analysis. We find that (i) there are significant differences between the behaviour of this module in isolation and in a network: thresholds may be altered or destroyed and bistability may be destroyed or even induced, even when the ambient network is simple. The global characteristics and topology of this network and the position of the module in the ambient network can play important and unexpected roles. (ii) There can be important differences between the deterministic and stochastic dynamics of the module embedded in networks, which may be accentuated by the ambient network. This provides new insights into the functioning of such enzymatic modules individually and as part of networks, with relevance to other enzymatic signalling modules as well.
Previous analytical and simulation-based analyses suggest that deeper land surface models are needed to realistically simulate the terrestrial thermal state in climate models, with implications for land-atmosphere interactions. Analytical approaches mainly focused on the subsurface propagation of harmonics such as the annual temperature signal, and a direct comparison with climate-change model output has been elusive. Here, this study addresses the propagation of a harmonic pulse fitted to represent the timescale and amplitude of anthropogenic warming. Its comparison to land model simulations with stepwise increased bottom boundary depth leads to an agreement between the simulation-based and analytical frameworks for long-term climate trends. Any depth increase gradually decreases the relative error in the subsurface thermodynamics, and a minimum depth of 170 m is recommended to simulate the ground climate adequately. The approach provides an accurate estimate of the required land-model depth for climate-change simulations and assesses the relative bias in insufficiently deep land models.