Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulation and field testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Potential benefits and optimization of cool-coated office buildings: A case study in Chongqing, China

Increasing envelope facet albedos considerably reduces solar heat gain, thus yielding building cooling energy savings. Few studies have explored the potential benefits of utilizing cool coatings on building envelopes (“cool-coated buildings”) based on life-cycle cost analysis. A holistic approach integrating the field testing, building energy simulation, and a 20-year life-cycle-based optimization was developed to explore cool-coated building performance and the maximum net savings of optimal building envelope retrofit and design. Experimental results showed that applying cool coatings to a west wall of an office building in Chongqing, China reduced its exterior surface temperature by up to 9.3 °C in summer. Additionally, simulation results showed that in Chongqing, making the roof and walls cool could reduce annual HVAC electricity use by up to 11.9% in old buildings (with poorly insulated envelopes) and up to 5.9% in new buildings. Retrofitting old buildings with a cool roof provided the net savings per modified area with present values up to 42.8 CNY/m2; retrofitting a new building with a cool roof or cool walls was not cost-effective. Optimizing both envelope insulation and envelope albedo can achieve 5.6 times the net savings of optimizing the insulation only, and 1.6 times that of optimizing albedo only.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient Data Library of Solar Grid Integrated Distributed System

This submission contains an open-source library of transient events in distributed system with high solar PV. The library includes the collected data, related documents and scripts for loading the data. The data library is built for transient event detection and machine learning based analysis algorithm development. The data was collected via both field test and software simulation. The units for the data are included in the data file headers for each data series. A text editor or spreadsheet software, such as Excel, and Matlab is required to view the data.

algorithms↗

Dendrite-resolved, full-melt-pool phase-field simulations to reveal non-steady-state effects and to test an approximate model

In this report we study the epitaxial, columnar growth of (multiply oriented) dendrites/cells for a spot melt in a polycrystalline Al–Cu substrate using two-dimensional, phase-field, direct numerical simulations (DNS) at the full-melt-pool scale. Our main objective is to compare the expensive DNS model to a much cheaper but approximate “line” model in which a single-crystal phase-field simulation is confined to a narrow rectangular geometry. To perform this comparison, we develop algorithms that automatically extract quantities of interest (QoIs) from both DNS and line models. These QoIs allow us to quantitatively assess the assumptions in the line model and help us analyze its discrepancy with the DNS model. We consider four sets of heat source parameters, mimicking welding and additive manufacturing conditions, that create a combination shallow and deep melt pools. Our largest DNS simulation used 16K x 14K grid points in space. Our main findings can be summarized as follows. Under AM conditions, the QoIs of line models are in excellent agreement with the full DNS results for both shallow and deep melt pools. Under welding conditions, the primary spacing of the DNS model is smaller than the prediction of line model. We identify a geometric crowding effect that accounts for the discrepancies between the DNS and line models. We propose two potential mechanisms that determine the response of the microstructure to geometric crowding.

36 MATERIALS SCIENCE↗

The EGS Collab Project – Stimulations at Two Depths

The EGS Collab project, supported by the US Department of Energy, is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory to address challenges in implementing enhanced geothermal systems (EGS). Data and observations from the field tests are compared to simulations to understand processes and build confidence in numerical modeling of the processes. We have completed Experiment 1 (of 3), which examined hydraulic fracturing in a well-characterized underground fractured phyllite test bed at a depth of approximately 1.5 km at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. Testbed characterization included fracture mapping, borehole acoustic and optical televiewers, full waveform sonic, conductivity, resistivity, temperature, campaign p- and s-wave investigations and electrical resistance tomography. Borehole geophysical techniques including passive seismic, continuous active source seismic monitoring, electrical resistance tomography, fiber-based distributed strain, distributed temperature, and distributed acoustic monitoring, were used to carefully monitor stimulation events and flow tests. More than a dozen stimulations and nearly one year of flow tests were performed. Quality data and detailed observations were collected and analyzed during stimulation and water flow tests using ambient temperature and chilled water. We achieved adaptive control of the tests using real-time monitoring and rapid dissemination of data and near-real-time simulation. More detailed numerical simulation was performed to answer key experimental design questions, forecast fracture propagation trajectories and extents, and analyze and evaluate results. Data are freely available from the Geothermal Data Repository. Experiment 2 examines the potential for hydraulic shearing in amphibolite at a depth of about 1.25 km at SURF. This site has a different set of stress and fracture conditions than Experiment 1. The Experiment 2 testbed consists of nine subhorizontal boreholes configured in two fans of two boreholes which surround the testbed and contain grouted-in electrical resistance tomography, seismic sensors, active seismic sources and distributed fiber sensors. A “five-spot” set of test wells that extends from a custom mined alcove includes an injection well and four production/monitoring wells. The testbed was characterized geophysically and hydrologically, and three stimulations have been performed using the Step-Rate Injection Method for Fracture In-Situ Properties (SIMFIP) tool to measure strains, and a new strain quantifying tool (downhole robotic strain analysis tool -DORSA) was deployed in a monitoring hole during stimulation. Real-time data were broadcast during stimulations to allow real-time response to arising issues.

EGS Collab, Enhanced Geothermal Systems, EGS, fiel↗

Oil Recovery Prediction for Polymer Flood Field Test of Heavy Oil on Alaska North Slope Via Machine Assisted Reservoir Simulation

The first ever polymer flood field pilot to enhance the recovery of heavy oils on the Alaska North Slope is ongoing. This study constructs and calibrates a reservoir simulation model to predict the oil recovery performance of the pilot through machine-assisted reservoir simulation techniques. To replicate the early water breakthrough observed during waterflooding, transmissibility contrasts are introduced into the simulation model, forcing viscous fingering effects. In the ensuing polymer flood, these transmissibility contrasts are reduced to replicate the restoration of injection conformance during polymer flooding, as indicated by a significant decrease in water cut. Later, transmissibility contrasts are reinstated to replicate a water surge event observed in one of the producing wells during polymer flooding. This event may represent decreased injection conformance from fracture overextension; its anticipated occurrence in the other production well is included in the final forecast. The definition of polymer retention in the simulator incorporates the tailing effect reported in laboratory studies; this tailing effect is useful to the simultaneous history match of producing water cut and produced polymer concentration. The top 24 best-matched simulation models produced at each stage of the history matching process are used to forecast oil recovery. The final forecast clearly demonstrates that polymer flooding significantly increases the heavy oil production for this field pilot compared to waterflooding alone. This exercise displays that a simulation model is only valid for prediction if flow behavior in the reservoir remains consistent with that observed during the history matched period. Critically, this means that a simulation model calibrated for waterflooding may not fully capture the benefits of an enhanced oil recovery process such as polymer flooding. Therefore, caution is recommended in using basic waterflood simulation models to scope potential enhanced oil recovery projects.

Keith, Cody Douglas↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

Computational study of runaway electrons in MST tokamak discharges with applied resonant magnetic perturbation

A numerical study of magnetohydrodynamics (MHD) and tracer-particle evolution investigates the effects of resonant magnetic perturbations (RMPs) on the confinement of runaway electrons (REs) in tokamak discharges conducted in the Madison Symmetric Torus. In computational results of applying RMPs having a broad toroidal spectrum but a single poloidal harmonic, m = 1 RMP does not suppress REs, whereas m = 3 RMP achieves significant deconfinement but not the complete suppression obtained in the experiment. MHD simulations with the NIMROD code produce sawtooth oscillations, and the associated magnetic reconnection can affect the trajectory of REs starting in the core region. Simulations with m = 3 RMP produce chaotic magnetic topology over the outer region, but the m = 1 RMP produces negligible changes in field topology, relative to applying no RMP. Using snapshots of the MHD simulation fields, full-orbit relativistic electron test particle computations with KORC show ≈50% loss from the m = 3 RMP compared to the 10%–15% loss from the m = 1 RMP. Here, test particle computations of the m = 3 RMP in the time-evolving MHD simulation fields show correlation between MHD activity and late-time particle losses, but total electron confinement is similar to computations using magnetic-field snapshots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Statistics-Based Threshold for the RMS-Energy Oscillation Detector

System operators and reliability coordinators currently rely on extensive baselining studies to set thresholds for their oscillation detectors. The resulting thresholds are based largely on engineering judgment and may vary significantly between organizations. In this paper, statistical distribution theory is used to derive a detection threshold for the widely deployed root-mean-square (RMS)-energy detector. This expression provides a theoretical basis for the detector's configuration, simplifies the process of selecting the threshold, and enables improved consistency among organizations that need to coordinate during system-wide events. Three methods for calculating the threshold using synchrophasor measurements are also proposed. These methods ensure that the threshold can be calculated reliably for various applications. Tests with simulated and field-measured data demonstrate that the statistics-based threshold provides consistent detection of grid disturbances while maintaining a low probability of false alarm.

Follum, James D.↗

Factors Influencing Building Demand Flexibility

The U.S. Department of Energy’s National Roadmap for Grid-interactive Efficient Buildings (GEB) acknowledged that building demand flexibility (DF) is both an important strategy to decarbonizing the buildings sector and an important resource for meeting the changing needs of the electrical grid such as improving grid reliability. However, understanding the complexity and uncertainties in real building field performance of DF strategies is a large gap hindering stakeholders on both grid and buildings side to make investments on deploying such strategies. The research work in this report intended to advance understanding of the variability and influential factors in building demand flexibility. Adding such knowledge based on lab testing results and measured performance data from real buildings is an important contribution. The report uses standardized metrics and methods to quantify DF performance from field-measured DF datasets of two significant building groups of big-box retail and medium office buildings to present the challenge of building DF variability in multiple dimensions. The report presents findings related to how several key factors influence building demand flexibility from implementing a common, cost-effective DF control strategy (i.e., adjusting zone temperatures). The findings are supported by full-scale lab testing, field data analysis and simulation research. The authors also provided application-oriented recommendations to stakeholders such as building aggregators, utility program design professionals, sophisticated building portfolio owners, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generalizable Web User Interface for Scalable and Streamlined Deployment of Building Energy Management Systems in Small and Medium-Sized Commercial Buildings

Small and medium-sized commercial buildings (SMCBs) comprise 94% of US commercial buildings yet face significant barriers to implementing building energy management systems despite advances in smart device technology. Existing solutions present critical limitations: cloud-based API solutions simplify deployment but create vendor lock-in constraints; commercial integrated software solutions ensure compatibility via standardized protocols but require substantial cost and technical expertise; open-source IoT platforms offer cost-effective vendor independence but provide insufficient standardized protocol support for commercial building automation. This research presents a generalizable web user interface framework that bridges the gap between evolving smart device capabilities and lagging software infrastructure for SMCBs. The proposed system integrates VOLTTRON open-source middleware with an automated configuration converter that transforms unified specifications written in YAML, a human-readable data-serialization format, into system-specific files, streamlining manual setup processes. The vendor-agnostic architecture supports industry-standard protocols (BACnet and Modbus) and semantic building models while providing adaptive web interfaces that dynamically adjust to various building configurations. Demonstrations through simulation-based testing and a field deployment show automatic interface adaptation across heterogeneous HVAC systems and multizone monitoring. The automated configuration converter also substantially reduces labor-intensive setup.

Chung, Jihoon [ORNL] (ORCID:0000000184880815)↗

Enabling AI in synthetic biology through Construction File specification

The Construction File (CF) specification establishes a standardized interface for molecular biology operations, laying a foundation for automation and enhanced efficiency in experiment design. It is implemented across three distinct software projects: PyDNA_CF_Simulator, a Python project featuring a ChatGPT plugin for interactive parsing and simulating experiments; ConstructionFileSimulator, a field-tested Java project that showcases 'Experiment' objects expressed as flat files; and C6-Tools, a JavaScript project integrated with Google Sheets via Apps Script, providing a user-friendly interface for authoring and simulation of CF. The CF specification not only standardizes and modularizes molecular biology operations but also promotes collaboration, automation, and reuse, significantly reducing potential errors. The potential integration of CF with artificial intelligence, particularly GPT-4, suggests innovative automation strategies for synthetic biology. While challenges such as token limits, data storage, and biosecurity remain, proposed solutions promise a way forward in harnessing AI for experiment design. This shift from human-driven design to AI-assisted workflows, steered by high-level objectives, charts a potential future path in synthetic biology, envisioning an environment where complexities are managed more effectively.

59 BASIC BIOLOGICAL SCIENCES↗

Adjusting the Energy Profile for CH–O Interactions Leads to Improved Stability of RNA Stem-Loop Structures in MD Simulations

The role of ribonucleic acid (RNA) in biology continues to grow, but insight into important aspects of RNA behavior is lacking, such as dynamic structural ensembles in different environments, how flexibility is coupled to function, and how function might be modulated by small molecule binding. In the case of proteins, much progress in these areas has been made by complementing experiments with atomistic simulations, but RNA simulation methods and force fields are less mature. It remains challenging to generate stable RNA simulations, even for small systems where well-defined, thermostable structures have been established by experiments. Further many different aspects of RNA energetics have been adjusted in force fields, seeking improvements that are transferable across a variety of RNA structural motifs. In this work, the role of weak CH···O interactions is explored, which are ubiquitous in RNA structure but have received less attention in RNA force field development. By comparing data extracted from high-resolution RNA crystal structures to energy profiles from quantum mechanics and force field calculations, it is shown that CH···O interactions are overly repulsive in the widely used Amber RNA force fields. A simple, targeted adjustment of CH···O repulsion that leaves the remainder of the force field unchanged was developed. Then, the standard and modified force fields were tested using molecular dynamics (MD) simulations with explicit water and salt, amassing over 300 μs of data for multiple RNA systems containing important features such as the presence of loops, base stacking interactions as well as canonical and noncanonical base pairing. In this work and others, standard force fields lead to reproducible unfolding of the NMR-based structures. Including a targeted CH···O adjustment in an otherwise identical protocol dramatically improves the outcome, leading to stable simulations for all RNA systems tested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Impact of the 8–10 March 2012 Geomagnetic Storm on Inner Zone Protons as Measured by Van Allen Probes

The Relativistic Electron Proton Telescope (REPT) instrument on the Van Allen Probes observed a double-peaked inner zone proton population throughout the 7 year lifetime of the mission. M. Hudson et al. (2023) showed that a strong SEP event accompanied by a CME-shock in early March 2012 provided the Solar Energetic Proton (SEP) source for the higher L trapped proton population, which then diffused radially inward to be observed by REPT at L = 2. The study followed trajectories of SEP protons launched isotropically from a sphere at 7 Re for 2.5 hr in fields calculated by the LFM-RCM global MHD model, which includes electric fields needed to model the transport and trapping of the protons by the shock, and then a radial diffusion simulation was run for 2 years using the result from the test-particle simulation as the initial condition. The simulation result was compared with REPT measurement in November 2013 and showed reasonable agreement. However, the simulation overestimated the Phase Space Density by a factor of four due to lack of field line curvature scattering during the storm in the model. In this study, a test-particle simulation is performed for 2 days following the injection and trapping of protons in March 2012 using TS05 fields to simulate the field line curvature scattering of the trapped SEP due to the buildup of the ring current during the geomagnetic storm. The resulting sample distribution was then weighted using the flux at the end of the two-hour MHD-test particle simulation. A radial diffusion simulation is then run using the initial profile that included the loss effect, with improved comparison with REPT measurements after 2 years.

79 ASTRONOMY AND ASTROPHYSICS↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

Zhang, Bo↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

25 ENERGY STORAGE↗

Sensitivity and history match analysis of a carbon dioxide “huff-and-puff” injection test in a horizontal shale gas well in Tennessee

Due to improvements in well development, shale gas production has gained importance recently, especially in the United States. To improve gas production and develop a better understanding of shale reservoirs, researchers are conducting field tests to monitor CO 2 storage and enhanced gas recovery. Reservoir simulations can then utilize these field results for sensitivity studies, uncertainty analysis, history matching, gas production forecasts, and CO 2 storage capacity estimations. One such field test was performed for the Chattanooga Shale formation in Morgan County, Tennessee. Approximately 463 tonnes (510 tons) of CO 2 was successfully injected into a hydraulically fractured horizontal well over a thirteen-day period in March 2014. The injection test was achieved in four steps: pre-injection, injection, soaking, and flowback. In this paper, those steps were modeled with a reservoir simulator to match the historic production and injection rates with gas component compositions and forecast the production for five years. The reservoir fluid was modeled as a multi-component gas, including CH 4 , C 2 H 6 , C 3 H 8 , N 2 , and CO 2 . Langmuir constants, reservoir pressure, and fracture network volume were adjusted to match simulation results with observed production rates and gas composition. Results showed that, under the same reservoir conditions, each gas component behaves differently by way of compositional changes in production. CH4 behaves like N2, while CO 2 behaves like heavier hydrocarbons such as C 2 H 6 and C 3 H 8 . CO 2 plume results showed that, after injection, the produced CO 2 is mostly derived from fractured limestone (i.e., Fort Payne Formation) because the injected CO 2 is not adsorbed in limestone but rather by shale formations.

03 NATURAL GAS↗