Search NASA⌕ Search

SEARCH · Search NASA

Results for “single experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Combined Environments: Driving multiple loads on Z

Pulsed power drivers such as the Z generator of Sandia National Laboratories typically deliver high current (>20MA) to single experiments. This project is intended to develop and assess ways to simultaneously drive multiple targets on a single pulsed power driver (specifically a neutron and an x-ray producing target driven in a single experiment). The combined x-ray/neutron environment produced will then be used to investigate potential synergistic effects in integrated circuits. A pre-requisite for being able to design and study multiple targets on Z is first adapting simulation tools to be able to model them effectively. This will enable us to assess the tradeoffs between the different ways multiple targets can be combined, and to better understand how existing and future pulsed power machines can be used to generate combined testing environments. This report is limited to documenting the initial development of a parallel load modeling capability that is presently being applied to design experiments to produce combined neutron/x-ray environments on Z.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Prompt Neutron Decay Constant Measurements to Obtain Additional Kinetics Information

Prompt neutron decay constant measurements are typically used to infer the prompt neutron lifetime in a chain-reacting system, but these measurements include much more information about the kinetics of the system. This work focuses specifically on the Rossi-α method of measuring the prompt neutron decay constant. The Rossi-α system of equations consists of five unknown parameters. With five unknowns and three equations, the system of equations solved by the Rossi-α measurement is under-determined. It has been postulated that a well posed problem can be formulated using independent measurement configurations on a single system. The external source strength, the effective delayed neutron fractions, and Diven’s parameter do not typically change for different configurations of a single experiment. If good detector geometry is chosen, the detector efficiency does not change for multiple measurements of a single experiment using Rossi-α measurements. By making these assumptions, there are only two unique variables. This knowledge can be used to solve for most of the unique parameters using two independent, unique Rossi-α measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation drive designed to extend the pressure ranges measured in Gbar equation of state experiments at the National Ignition Facility

We present the design and demonstration of a Shock-Strengthening hohlraum radiation temperature drive in the Gbar experimental platform at the National Ignition Facility intended to increase the pressure range measured in a single experiment. Previously published experiments by Döppner et al. measured the equation of state in polystyrene from 25 to 60 Mbar. Recent experimental data of the Shock-Strengthening drive initially demonstrated a much larger pressure range from 15 to 110 Mbar using the same peak radiation temperature and experimental platform. The Shock-Strengthening drive starts with a low temperature foot that launches a weak shock into the sample and is followed by a continuous increase in radiation temperature to strengthen the leading shock. The additional strengthening increases the pressure within the sample beyond what is achievable by convergence alone. Design features of the Shock-Strengthening drive and accompanying radiation hydrodynamics simulations are used to illustrate the method by which the pressure range is increased from previous experiments. This method of modifying the radiation temperature drive can be used on the Gbar platform to significantly increase the range for equation of state data collected in a single experiment for many materials.

Physics - Plasma physics↗

Efficient data reduction for time-of-flight neutron scattering experiments on single crystals

Event-mode data collection presents remarkable new opportunities for time-of-flight neutron scattering studies of collective excitations, diffuse scattering from short-range atomic and magnetic structures, and neutron crystallography. In these experiments, large volumes of the reciprocal space are surveyed, often using different wavelengths and counting times. These data then have to be added together, with accurate propagation of the counting errors. This paper presents a statistically correct way of adding and histogramming the data for single-crystal time-of-flight neutron scattering measurements. In order to gain a broader community acceptance, particular attention is given to improving the efficiency of calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of continuous and discontinuous collisional bumpers: Dimensionally scaled impact experiments into single wire meshes

An experimental inquiry into the utility of discontinuous bumpers was conducted to investigate the collisional outcomes of impacts into single grid-like targets and to compare the results with more traditional bumper designs that employ continuous sheet stock. We performed some 35 experiments using 6.3 and 3.2 mm diameter spherical soda-lime glass projectiles at low velocities (less than 2.5 km/s) and 13 at velocities between 5 and 6 km/s, using 3.2 mm spheres only. The thrust of the experiments related to the characterization of collisional fragments as a function of target thickness or areal shield mass of both bumper designs. The primary product of these experiments was witness plates that record the resulting population of collisional fragments. Substantial interpretive and predictive insights into bumper performance were obtained. All qualitative observations (on the witness plates) and detailed measurements of displaced masses seem simply and consistently related only to bumper mass available for interaction with the impactor. This renders the grid bumper into the superior shield design. These findings present evidence that discontinuous bumpers are a viable concept for collisional shields, possibly superior to continuous geometries.

Hoerz, Friedrich↗

Transcatheter Arterial Chemoembolization with Epirubicin-Loaded Superabsorbent Polymer Microspheres for 135 Hepatocellular Carcinoma Patients: Single-Center Experience

Purpose: To evaluate the safety, clinical outcomes, and hepatic artery damage after transcatheter arterial chemoembolization (TACE) with epirubicin-loaded superabsorbent polymer microspheres (ELM-TACE) in patients with hepatocellular carcinoma (HCC) in a single center in Japan. Materials and Methods: This embolic agent is the original form of microspheres, which has the same composition and nature as HepaSpheres. Between May 2007 and June 2009, 135 patients with unresectable HCC who underwent ELM-TACE were enrolled. Embolization through extrahepatic collaterals was performed in 27 (20.0%) patients. Tumor response was evaluated using European Association for the Study of the Liver criteria at 1 and 6 months after initial ELM-TACE. Results: All procedures were successfully performed. The median number of TACE per patient was 1.7 sessions (range 1-5), and the mean epirubicin dose per session was 19.7 mg (range 2.0-60.0). Local pooling within target tumors was observed during TACE in 34 (25.2%) patients, and in 14 (10.4%) of the patients, gelatin sponge particles were added after the microspheres until each pooling disappeared. No serious adverse events associated with TACE occurred, and the incidence of postembolization syndrome was {<=}17.8%. The 1- and 6-month tumor response rates were 56.3 and 52.6%, respectively. The overall 1- and 2-year survival rates were 73.7 and 59.0%, respectively. Among 99 evaluated patients, 90 (90.9%) were found to have no hepatic artery damage after initial ELM-TACE. Conclusion: ELM-TACE is safe and effective treatment for unresectable HCC and is associated with low frequency of postembolization syndrome and minimal damage to the hepatic artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic accuracy of acoustic radiation force impulse elastography (ARFI) in comparison to other non-invasive modalities in staging of liver fibrosis in chronic HCV patients: single-center experience

Purpose: To evaluate the reliability of ARFI elastography for liver fibrosis staging and compare it to other non-invasive assessment of hepatic fibrosis (FIB-4 and APRI) in chronic HCV (CHC) patients. Methods: A single-center, prospective study included 2103 CHC patients. Liver stiffness (LS) was evaluated by TE and ARFI elastography. FIB-4 and APRI were calculated. The area under the receiver-operating characteristic curve (AUROCs) was used to assess the diagnostic performance of ARFI elastography for staging of liver fibrosis using TE as a reference standard. Results: The best cut off values of ARFI elastography for diagnosis of ≥ F2, ≥ F3and F4 were 1.36 m/s, 1.45 m/s, and 1.7 m/s with AUROCs of 0.89, 0.94 and 0.95, respectively. ARFI elastography cut offs are lower in patients with normal ALT level compared to those with ALT level (1.1–< 3 ULN) and those with ALT level ≥ 3ULN (1.35 m/s vs 1.39 m/s vs 1.54 for F ≥ 2, 1.44 m/s vs 1.58 m/s vs 1.6 m/s for F3, 1.69 m/s, 1.84 m/s, 1.86 m/s for F4). FIB-4 (0.82–0.86) and APRI (0.78–0.82) yielded lower AUC in prediction of significant fibrosis and cirrhosis than ARFI elastography (0.89–0.95). Conclusion: ARFI elastography is a reliable method for non-invasive staging of liver fibrosis in CHC patients when compared to TE with a good diagnostic performance comparable to FIB-4 and APRI scores for the prediction of significant fibrosis and cirrhosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The 10-year Trend of Periprocedural Complication Following Carotid Artery Stenting; Single Center Experience

PurposeCarotid endarterectomy and stenting are used to treat carotid stenosis, with the volume of carotid artery procedures increasing over the past decade. We investigated the 10-year trend of periprocedural complications with an increasing procedure volume of carotid stenting at a single tertiary hospital.MethodsWe collected 416 consecutive cases (384 patients) of carotid artery stenting performed for either symptomatic (231 cases, 55.5 %) or asymptomatic (185 cases, 44.5 %) internal carotid artery stenosis at a single center. Periprocedural complication was defined as any stroke, myocardial infarction, or death. Procedure-related outcome included any dissection, hemodynamic event, or periprocedural complication.ResultsThe mean age was 68.8 years (82.8 % males; range of 20–89 years); 23.9 % were older than 75 years. Before the procedure, 99.3 and 56.0 % of patients received antiplatelet and lipid-lowering medication, respectively. The overall periprocedural complication rate was 3.6 % (1.6 and 5.2 % in the asymptomatic and symptomatic group, respectively). The composite outcome of any stroke or death was 3.4 %. Periprocedural complication and procedure-related outcome showed a decremental trend with increasing procedure volume, and this trend remained after adjusting for confounders.ConclusionsOur study suggests that carotid stenting at an experienced center might reduce the periprocedural complications. Our periprocedural complication rate of carotid artery stenting may be comparable to, or somewhat lower than, that reported in other clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Behavior of Windblown Sand on Mars: Results from Single-Particle Experiments

Experiments are investigating the behavior of individual sand grains in the high-energy martian aeolian regime. Energy partitioning during impact of a saltating grain determines grain longevity, but it also influences the way in which the bed becomes mobilized by reptation. When single grains of sand are fired into loose beds, the bed can absorb up to 90% of the impact energy by momentum transfer to other grains; it has been discovered that the impacting grains cause circular craters even at low impact angles. Hundreds of grains can be splashed by a single high-velocity (100 m/s) impact causing more bed disturbance through reptation than previously thought. The research is supported by NASA's PG&G Program. Because the martian aeolian environment in both high energy and of long duration, the most mobile fractions of windblown sand should have eradicated themselves by attrition, unless sand supply has kept pace with destruction. It is therefore important to understand the rate of grain attrition in order to make sense of the existence of vast dune fields on Mars. Attrition, has been addressed in other studies, but precise data for a single saltating grain striking a loose bed of sand have not been acquired -- the quintessential case to be understood for dunes on Mars. To acquire these data, we are employing a compound crossbow which has the bolt-firing mechanism replaced with a pneumatically-automated sabot system. The sabot can launch individual grains of sand of any size between several millimeters and about 50 microns, at velocities up to 100m/s. This is around the maximum velocity expected for saltating grains on Mars. The sabot sled is equipped with photoelectric sensors for measuring shot velocity. Baffling of the grain's exit orifice has enabled projection of single grains without significant aerodynamic effects from the sabot. Grains are fired into loose beds of sand at about 15 degrees from the horizontal (typical saltation trajectory at impact) while being filmed on high-speed video. High-intensity pulse illumination for the grains is triggered by the solenoid-operated bow trigger. A 45 degree mirror over the impact site provides simultaneous horizontal and vertical images of the impact on each video frame. UV fluorescence is enabling grain and grain-fragment recovery. At 100 m/s, grains of all sizes shatter into many fragments when the sand is replaced with a solid target. Kinetic energy of the grains at this velocity exceeds the critical energy for catastrophic failure of minerals. Although probably exceptional as a grain speed, it suggests that conditions on Mars might elevate materials into an attrition regime not encountered on other planets; individual grains blown across rock pavements on Mars will have short lifespans. When experimental grains impact loose (dune) sand, much, if not most of the kinetic energy is converted into momentum of other grains. Using high-speed filming, the energy involved in splashing grains at the impact site can be derived from the size of the crater, the speed of the splashed grains, and the rebound speed of the impactor. The amount of energy partitioned into material failure (as opposed to momentum) is too small a fraction of the total to be calculated under these circumstances. This does not necessarily mean that little damage occurs to the grains (the full extent of the damage has yet to be determined) because only a small fraction of the impact energy is required for inducing brittle fracture. Damage is orders of magnitude less than during impact against solid surfaces.

Marshall, J. R.↗

High-pressure high-temperature phase diagram of gadolinium studied using a boron-doped heater anvil

A boron-doped designer heater anvil is used in conjunction with powder x-ray diffraction to collect structural information on a sample of quasi-hydrostatically loaded gadolinium metal up to pressures above 8 GPa and 600 K. The heater anvil consists of a natural diamond anvil that has been surface modified with a homoepitaxially grown chemical-vapor-deposited layer of conducting boron-doped diamond, and is used as a DC heating element. Internally insulating both diamond anvils with sapphire support seats allows for heating and cooling of the high-pressure area on the order of a few tens of seconds. This device is then used to scan the phase diagram of the sample by oscillating the temperature while continuously increasing the externally applied pressure and collecting in situ time-resolved powder diffraction images. In the pressure-temperature range covered in this experiment, the gadolinium sample is observed in its hcp, αSm, and dhcp phases. Under this temperature cycling, the hcp → αSm transition proceeds in discontinuous steps at points along the expected phase boundary. From these measurements (representing only one hour of synchrotron x-ray collection time), a single-experiment equation of state and phase diagram of each phase of gadolinium is presented for the range of 0–10 GPa and 300–650 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-large-scale cosmology in next-generation experiments with single tracers

Future surveys of large-scale structure will be able to measure perturbations on the scale of the cosmological horizon, and so could potentially probe a number of novel relativistic effects that are negligibly small on sub-horizon scales. These effects leave distinctive signatures in the power spectra of clustering observables and, if measurable, would open a new window on relativistic cosmology. We quantify the size and detectability of the effects for the most relevant future large-scale structure experiments: spectroscopic and photometric galaxy redshift surveys, intensity mapping surveys of neutral hydrogen, and radio continuum surveys. Our forecasts show that next-generation experiments, reaching out to redshifts z≃4, will not be able to detect previously undetected general-relativistic effects by using individual tracers of the density field, although the contribution of weak lensing magnification on large scales should be clearly detectable. We also perform a rigorous joint forecast for the detection of primordial non-Gaussianity through the excess power it produces in the clustering of biased tracers on large scales, finding that uncertainties of σ(f{sub NL})∼1−2 should be achievable. We study the level of degeneracy of these large-scale effects with several tracer-dependent nuisance parameters, quantifying the minimal priors on the latter that are needed for an optimal measurement of the former. Finally, we discuss the systematic effects that must be mitigated to achieve this level of sensitivity, and some alternative approaches that should help to improve the constraints. The computational tools developed to carry out this study, which requires the full-sky computation of the theoretical angular power spectra for O(100) redshift bins, as well as realistic models of the luminosity function, are publicly available at http://intensitymapping.physics.ox.ac.uk/codes.html.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of conventional versus liposomal irinotecan in combination with fluorouracil for advanced pancreatic cancer: a single-institution experience

The majority of pancreatic cancers are diagnosed at an advanced stage, when surgical options are limited and treatment relies on systemic chemotherapy. In the NAPOLI-1 trial, liposomal irinotecan in combination with fluorouracil (nal-iri/5FU) was shown to improve overall survival when compared to fluorouracil alone for metastatic pancreatic cancer. Other retrospective studies have shown the combination of fluorouracil and conventional irinotecan (FOLFIRI) to be a viable option, though no randomized trials have compared nal-iri/5FU to FOLFIRI. The purpose of this single-center, retrospective, cohort study was to determine if nal-iri/5FU and FOLFIRI are similarly effective for the treatment of advanced pancreatic cancer. Due to the potential for treatment bias, inverse probability of treatment weighting was utilized to correct for baseline differences between the groups. The primary outcome of progression-free survival was similar at 4.1 months for nal-iri/5FU and 3.1 months for FOLFIRI. Overall survival and adverse effect frequency were also similar. Pegfilgrastim was used in 16% and 15% of patients, respectively, and nal-iri/5FU patients required significantly less atropine during treatment (36 vs. 70%). A cost analysis was conducted and concluded that the treatment with nal-iri/5FU was nearly 30 times more expensive than FOLFIRI treatment. Together, these data suggest a potential role for FOLFIRI for the treatment of advanced pancreatic cancer in the absence of clear benefits in effectiveness, toxicity, or cost for nal-iri/5FU.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-284: Dose Plan Optimization When Using Hydrogel Prostate-Rectum Spacer: A Single Institution Experience

Purpose: To describe rectal dose reduction achieved and techniques used to take advantage of the increased peri-rectal spacing provided by injected polyethylene-glycol. Methods: Thirty prostate cancer patents were 2:1 randomized during a clinical trial to evaluate the effectiveness of injected poly-ethylene glycol hydrogel (SpaceOAR System) in creating space between the prostate and the anterior rectal wall. All patients received a baseline CT/MR scan and baseline IMRT treatment plan. Patients were randomized to receive hydrogel injection (n=20) or Control (n=10), followed by another CT/MR scan and treatment plan (single arc VMAT, 6 MV photons, 79.2 Gy, 44 fractions). Additional optimization structures were employed to constrain the dose to the rectum; specifically an avoidance structure to limit V75 <15%, and a control structure to limit the maximum relative dose <105% in the interface region of the anterior rectal wall and the prostate planning target volume. Dose volumetric data was analyzed for rectal volumes receiving 60 through 80 Gy. Results: Rectal dose reduction was observed in all patients who received the hydrogel. Volumetric analysis indicates a median rectal volume and (reduction from baseline plan) following spacer application of 4.9% (8.9%) at V60Gy, 3.8% (8.1%) at V65Gy, 2.5% (7.2%) at V70Gy, 1.6% (5.8%) at V75Gy, and 0.5% (2.5%) at V80Gy. Conclusion: Relative to planning without spacers, rectal dose constraints of 5%, 4%, 3%, 2%, 1% for V60, V65, V70, V75, and V80, should be obtainable when peri-rectal spacers are used. The combined effect of increased peri-rectal space provided by the hydrogel, with strict optimization objectives, resulted in reduced dose to the rectum. To maximize benefit, strict optimization objectives and reduced rectal dose constraints should be employed when creating plans for patients with perirectal spacers. Clinical Trial for SpaceOAR product conducted by Augmenix,Inc. The research site was paid to be a participating site.

60 APPLIED LIFE SCIENCES↗

Intraoperative Radiotherapy for Parotid Cancer: A Single-Institution Experience

Purpose: Our practice policy has been to provide intraoperative radiotherapy (IORT) at resection to patients with head-and-neck malignancies considered to be at high risk of recurrence. The purpose of the present study was to review our experience with the use of IORT for primary or recurrent cancer of the parotid gland. Methods and Materials: Between 1982 and 2007, 96 patients were treated with gross total resection and IORT for primary or recurrent cancer of the parotid gland. The median age was 62.9 years (range, 14.3-88.1). Of the 96 patients, 33 had previously undergone external beam radiotherapy as a component of definitive therapy. Also, 34 patients had positive margins after surgery, and 40 had perineural invasion. IORT was administered as a single fraction of 15 or 20 Gy with 4-6-MeV electrons. The median follow-up period was 5.6 years. Results: Only 1 patient experienced local recurrence, 19 developed regional recurrence, and 12 distant recurrence. The recurrence-free survival rate at 1, 3, and 5 years was 82.0%, 68.5%, and 65.2%, respectively. The 1-, 3-, and 5-year overall survival rate after surgery and IORT was 88.4%, 66.1%, and 56.2%, respectively. No perioperative fatalities occurred. Complications developed in 26 patients and included vascular complications in 7, trismus in 6, fistulas in 4, radiation osteonecrosis in 4, flap necrosis in 2, wound dehiscence in 2, and neuropathy in 1. Of these 26 patients, 12 had recurrent disease, and 8 had undergone external beam radiotherapy before IORT. Conclusions: IORT results in effective local disease control at acceptable levels of toxicity and should be considered for patients with primary or recurrent cancer of the parotid gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A general mechanism for gel layer formation on borosilicate glass under aqueous corrosion

Mineral and glass dissolution is a scientific topic deeply investigated but incompletely understood and of a great interest for the geochemical and materials science communities. If the interfacial dissolution/reprecipitation mechanism seems to be applicable to most of silicate minerals, the debate remains open concerning glass. Here we studied two model glasses, a ternary borosilicate (CJ1) and the same glass doped with 4.1 mol% of Al2O3 (CJ2). The two glasses were altered at 90°C, pH 9, and in conditions far and close to saturation with respect to amorphous silica, to determine the initial and residual rates. Moreover, a specific experiment was conducted for a short duration with a solution highly enriched with 18O and 29Si isotopes to understand how passivating gels form. SEM, TEM and ToF-SIMS characterization, along with Monte Carlo simulations were used to understand the rate limiting reactions at play and infer the role of Al. We show that Al yields a slower matrix dissolution in dilute conditions. However, it slows down he formation and the maturation of the passivating gel and favors alteration by partial hydrolysis of Si and Al entities followed by in-situ reorganization/relaxation into a porous network. Unexpectedly, CJ1 experienced both interfacial dissolution/reprecipitation and partial hydrolysis followed by in situ reorganization of the silicate network during the course of a single experiment. This study offers a unified concept that can pave the way for the future development of a predictive kinetic model based on a detailed description of bond breaking and bond forming as a function of glass composition and alteration conditions.

Gin, Stephane↗

OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients

We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9). Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of High-Power, Reversed-Cherenkov Wakefield Radiation in a Metamaterial Structure

Here, we present the first demonstration of high-power, reversed-Cherenkov wakefield radiation by electron bunches passing through a metamaterial structure. The structure supports a fundamental transverse magnetic mode with a negative group velocity leading to reversed-Cherenkov radiation, which was clearly verified in the experiments. Single 45 nC electron bunches of 65 MeV traversing the structure generated up to 25 MW in 2 ns pulses at 11.4 GHz, in excellent agreement with theory. Two bunches of 85 nC with appropriate temporal spacing generated up to 80 MW by coherent wakefield superposition, the highest rf power that metamaterial structures ever experienced without damage. These results demonstrate the unique features of metamaterial structures that are very attractive for future high-gradient wakefield accelerators, including two-beam and collinear accelerators. Advantages include the high shunt impedance for high-power generation and high-gradient acceleration, the simple and rugged structure, and a large parameter space for optimization.

43 PARTICLE ACCELERATORS↗

LABORATORY MEASUREMENTS OF WHITE DWARF PHOTOSPHERIC SPECTRAL LINES: Hβ

We spectroscopically measure multiple hydrogen Balmer line profiles from laboratory plasmas to investigate the theoretical line profiles used in white dwarf (WD) atmosphere models. X-ray radiation produced at the Z Pulsed Power Facility at Sandia National Laboratories initiates plasma formation in a hydrogen-filled gas cell, replicating WD photospheric conditions. Here we present time-resolved measurements of Hβ and fit this line using different theoretical line profiles to diagnose electron density, n{sub e}, and n = 2 level population, n{sub 2}. Aided by synthetic tests, we characterize the validity of our diagnostic method for this experimental platform. During a single experiment, we infer a continuous range of electron densities increasing from n{sub e} ∼ 4 to ∼30 × 10{sup 16} cm{sup −3} throughout a 120-ns evolution of our plasma. Also, we observe n{sub 2} to be initially elevated with respect to local thermodynamic equilibrium (LTE); it then equilibrates within ∼55 ns to become consistent with LTE. This supports our electron-temperature determination of T{sub e} ∼ 1.3 eV (∼15,000 K) after this time. At n{sub e} ≳ 10{sup 17} cm{sup −3}, we find that computer-simulation-based line-profile calculations provide better fits (lower reduced χ{sup 2}) than the line profiles currently used in the WD astronomy community. The inferred conditions, however, are in good quantitative agreement. This work establishes an experimental foundation for the future investigation of relative shapes and strengths between different hydrogen Balmer lines.

79 ASTRONOMY AND ASTROPHYSICS↗