Search NASA⌕ Search

SEARCH · Search NASA

Results for “single-shot diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

24 records · Page 2

Electron-beam-based Compton scattering x-ray source for probing high-energy-density physics

The physics basis for an electron-beam-based Compton scattering x-ray source is investigated for single-shot experiments at the major high-energy-density facilities, such as the Omega Laser Facility, National Ignition Facility, and Z pulsed power facility. A source of monoenergetic ( δ ε / ε < 5 % ) 10- to 50-keV x rays can be produced by scattering of a short-pulse optical laser by a 23- to 53-MeV electron beam and collimating the scattered photons. The number and spectrum of scattered photons are calculated as a function of electron packet charge, electron and laser pulse duration, laser intensity, and collision geometry. A source delivering greater than 10 10 photons in a 1-mm-radius spot and 100-ps time resolution is plausible with the available electron gun and laser technology. Applications of this source for x-ray diffraction, x-ray imaging, x-ray absorption fine structure, and x-ray absorption spectroscopy in high-energy-density physics experiments are described, demonstrating significant advancements compared to the present state of the art. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Toward monochromated sub-nanometer UEM and femtosecond UED

A preliminary design of a mega-electron-volt (MeV) monochromator with 10 –5 energy spread for ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) is presented. Such a narrow energy spread is advantageous in both the single shot mode, where the momentum resolution in diffraction is improved, and the accumulation mode, where shot-to-shot energy jitter is reduced. In the single-shot mode, we numerically optimized the monochromator efficiency up to 13% achieving 1.3 million electrons per pulse. In the accumulation mode, to mitigate the efficiency degradation caused by the shot-to-shot energy jitter, an optimized gun phase yields only a mild reduction of the single-shot efficiency, therefore the number of accumulated electrons nearly proportional to the repetition rate. Inspired by the recent work of Qi et al. (Phys Rev Lett 124:134803, 2020), a novel concept of applying reverse bending magnets to adjust the energy-dependent path length difference has been successfully realized in designing a MeV monochromator to achieve the minimum energy-dependent path length difference between cathode and sample. Thanks to the achromat design, the pulse length of the electron bunches and the energy-dependent timing jitter can be greatly reduced to the 10 fs level. The introduction of such a monochromator provides a major step forward, towards constructing a UEM with sub-nm resolution and a UED with ten-femtosecond temporal resolution. The one-to-one mapping between the electron beam parameter and the diffraction peak broadening enables a real-time nondestructive diagnosis of the beam energy spread and divergence. The tunable electric–magnetic monochromator allows the scanning of the electron beam energy with a 10 –5 precision, enabling online energy matching for the UEM, on-momentum flux maximizing for the UED and real-time energy measuring for energy-loss spectroscopy. A combination of the monochromator and a downstream chicane enables “two-color” double pulses with femtosecond duration and the tunable delay in the range of 10 to 160 fs, which can potentially provide an unprecedented femtosecond time resolution for time resolved UED.

36 MATERIALS SCIENCE↗

Multiframe X-ray diffraction on the OMEGA EP laser

A method of measuring multiple temporally resolved powder x-ray diffraction measurements during a single dynamic compression laser experiment has been demonstrated on the OMEGA EP laser. Up to four time-gated snapshots of the x-ray diffraction pattern are collected on an ultrafast x-ray framing camera with a 2θ scattering angle coverage of 48°–65° and 400-ps temporal resolution with the potential for 10°–160° and 200-ps resolution. X-ray diffraction snapshots capture the transformation to a high-pressure β phase in ramp-compressed Zr, constraining the atomic structure and pressure–density equation-of-state in a single shot. Here, this platform will be used to constrain transition pressures, understand the role of kinetics, and verify the existence of hysteresis and metastability on phase transformations at the lattice level under single-shot dynamic compression.

47 OTHER INSTRUMENTATION↗

Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering

We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of $T/Θ^2_D$, where Θ D is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-shot magnon interference in a magnon-superconducting-resonator hybrid circuit

Magnon interference is a hallmark of coherent magnon interactions. In this work, we demonstrate single-shot magnon interference using up to four magnon pulses in two remotely coupled yttrium iron garnet spheres mediated by a coplanar superconducting resonator. By exciting one YIG sphere with injected microwave pulses, we achieve coherent energy exchange between the two spheres, facilitating their interference processes, including Rabi-like oscillation with a single pulse, constructive and destructive interference with two pulses, and interference peak sharpening with up to four pulses—analogous to diffraction grating in optical interference. The resulting interference patterns can be precisely controlled by changing the frequency detuning and time delay of the magnon pulses. The demonstration of time-domain coherent control of remote magnon interference opens new pathways for advancing coherent information processing through multi-operation, circuit-integrated hybrid magnonic networks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate prediction of mega-electron-volt electron beam properties from UED using machine learning

To harness the full potential of the ultrafast electron diffraction (UED) and microscopy (UEM), we must know accurately the electron beam properties, such as emittance, energy spread, spatial-pointing jitter, and shot-to-shot energy fluctuation. Owing to the inherent fluctuations in UED/UEM instruments, obtaining such detailed knowledge requires real-time characterization of the beam properties for each electron bunch. While diagnostics of these properties exist, they are often invasive, and many of them cannot operate at a high repetition rate. Here, we present a technique to overcome such limitations. Employing a machine learning (ML) strategy, we can accurately predict electron beam properties for every shot using only parameters that are easily recorded at high repetition rate by the detector while the experiments are ongoing, by training a model on a small set of fully diagnosed bunches. Applying ML as real-time noninvasive diagnostics could enable some new capabilities, e.g., online optimization of the long-term stability and fine single-shot quality of the electron beam, filtering the events and making online corrections of the data for time-resolved UED, otherwise impossible. This opens the possibility of fully realizing the potential of high repetition rate UED and UEM for life science and condensed matter physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗