Search NASA⌕ Search

SEARCH · Search NASA

Results for “slice sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of X-ray Microscopy at IPOE

In order to meet the different requirements of applications in synchrotron radiation and plasma diagnosis in China, focusing and imaging optics based on Kirkpatrick-Baez (KB) mirrors, compound refractive lenses (CRLs), and multilayer Laue lenses (MLLs) were studied in our lab. A one-dimensional KB microscope using mirrors with a dual-periodic multilayer coating was developed. The multilayer mirror can reflect both 4.75 keV (Ti K-line) and 8.05 keV (Cu K-line) simultaneously, which makes alignment easier. For hard x-ray microscopy, CRL was studied. Using a SU-8 resist planar parabolic CRL, a focal line of 28.8-{mu}m width was obtained. To focus hard x-rays to nanometer levels efficiently, an MLL was fabricated using a WSi{sub 2}/Si multilayer. The MLL consists of 324 alternating WSi{sub 2} and Si layers with a total thickness of 7.9 {mu}m. (Recently, a much thicker multilayer has been deposited with a layer number of n = 1582 and a total thickness of 27 {mu}m.) After deposition, the sample was sliced and polished into an approximate ideal aspect ratio (depth of the zone plate to outmost layer thickness); the measured results show an intact structure remains, and the surface roughness of the cross section is about 0.4 nm after grinding and polishing processes.

43 PARTICLE ACCELERATORS↗

EPICS Controlled Collimator for Controlling Beam Sizes in HIPPO

Controlling the beam spot size and shape in a diffraction experiment determines the probed sample volume. The HIPPO - High-Pressure-Preferred Orientation– neutron time-offlight diffractometer is located at the Lujan Neutron Scattering Center in Los Alamos National Laboratories. HIPPO characterizes microstructural parameters, such as phase composition, strains, grain size, or texture, of bulk (cm-sized) samples. In the current setup, the beam spot has a 10 mm diameter. Using a collimator, consisting of two pairs of neutron absorbing boron-nitride slabs, horizontal and vertical dimensions of a rectangular beam spot can be defined. Using the HIPPO robotic sample changer for sample motion, the collimator would enable scanning of e.g. cylindrical samples along the cylinder axis by probing slices of such samples. The project presented here describes implementation of such a collimator, in particular the motion control software. We utilized the EPICS (Experimental Physics Interface and Control System) software interface to integrate the collimator control into the HIPPO instrument control system. Using EPICS, commands are sent to commercial stepper motors that move the beam windows.

43 PARTICLE ACCELERATORS↗

Diffusion technique for lithium-doped silicon

Sample is doped by constructing a sandwich of five slices of silicon with lithium dopant deposited on the outside surfaces of the second and fourth slices and placing the sample in the middle. Upon heating, the lithium diffuses through the carrier slices and into the sample wafer.

Kendall, D. L.↗

Artifacts from manganese reduction in rock samples prepared by focused ion beam (FIB) slicing for X-ray microspectroscopy

The spatial distribution oftransition metal valence states is of broad interest in the microanalysis ofgeological and environmental samples. An example is rock varnish, a naturalmanganese (Mn)-rich rock coating, whose genesis mechanism remains a subjectof scientific debate. We conducted scanning transmission X-ray microscopywith near-edge X-ray absorption fine-structure spectroscopy (STXM-NEXAFS)measurements of the abundance and spatial distribution of different Mnoxidation states within the nano- to micrometer thick varnish crusts. Suchmicroanalytical measurements of thin and hard rock crusts require samplepreparation with minimal contamination risk. Focused ion beam (FIB) slicingwas used to obtain ~100–1000 nm thin wedge-shaped slices of thesamples for STXM, using standard parameters. Yet, while this preparationis suitable for investigating element distributions and structures in rocksamples, we observed artifactual modifications of the Mn oxidation states atthe surfaces of the FIB slices. Our results imply that the preparationcauses a reduction of Mn 4+ to Mn 2+ . We draw attention tothis issue, since FIB slicing, scanning electron microscopy (SEM) imaging,and other preparation and visualization techniques operating in thekilo-electron-volt range are well-established in geosciences, but researchersare often unaware of the potential for the reduction of Mn and possibly otherelements in the samples.

58 GEOSCIENCES↗

HipGISAXS

Implementation of a flexible Grazing Incidence Small-Angle Scattering (GISAXS). Simulation code based on the Distorted Wave Born Approximation (DWBA) theory that effectively utilizes the parallel processing power provided by graphic processors and multicore processors. This constitutes a handy tool for experimentalists facing a massive flux of data, allowing them to accurately simulate the GISAXS process and analyze the produced data. The software computes the diffraction image for any given super position of custom shapes or morphologies in a user-defined region of the reciprocal space for all possible grazing incidence angles and in-plane sample rotations. This flexibility then allows to easily tackle a wide range of possible sample structures such as nanoparticles o top of or embedded in a substrate or a multilayered structure. In cases where the sample displays regions of significant refractive index contrast, an algorithm has been implemented to perform a slicing of the sample along the vertical direction and compute the averaging refractive index profile to be used as the reference geometry of the unpertubed system. Preliminary tests show good agreement with experimental data for a variety of commonly encountered nanostructures.

Xiaoye, Sherry Li↗

Use of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

The purpose behind this work is to provide NASA Principal Investigators (PI) rapid information, non-destructively, about their samples. This information will be in the form of density values throughout the samples, especially within slices 1 mm high. With correct interpretation and good calibration, these values will enable the PI to obtain macro chemical compositional analysis for his/her samples. Alternatively, the technique will provide information about the porosity level and its distribution within the sample. Experience gained with a NASA MRD-sponsored Advanced Technology Development (ATD) project on this topic has brought the technique to a level of maturity at which it has become a viable characterization tool for many of the Materials Science PIs, but with equipment that could never be supported within their own facilities. The existing computed tomography (CT) facility at NASA's Kennedy Space Center (KSC) is ideally situated to furnish information rapidly and conveniently to PIs, particularly immediately before and after flight missions.

Gillies, Donald C.↗

Use of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

The purpose behind this work is to provide NASA Principal Investigators (PIs) rapid information, nondestructively, about their samples. This information will be in the form of density values throughout the samples, especially within slices 1 mm high. With correct interpretation and good calibration, these values will enable the PI to obtain macro chemical compositional analysis for his/her samples. Alternatively, the technique will provide information about the porosity level and its distribution within the sample. Experience gained with a NASA Microgravity Research Division-sponsored Advanced Technology Development (ATD) project on this topic has brought the technique to a level of maturity at which it has become a viable characterization tool for many of the Materials Science Pls, but with equipment that could never be supported within their own facilities. The existing computed tomography (CT) facility at NASA's Kennedy Space Center (KSC) is ideally situated to furnish information rapidly and conveniently to PIs, particularly immediately before and after flight missions.

Gillies, Donald C.↗

All optical sampling by slanted light interrogation for cross-correlated encoded recording (slicer)

Single-shot transient optical signals are recorded in a time regime of picoseconds to nanosecond. An auxiliary pump beam is crossed through the signal to sample a diagonal ‘slice’ of space-time, analogous to a rolling shutter. The slice is then imaged onto an ordinary camera, where the recorded spatial trace is a direct representation of the time content of the signal. The pump samples the signal by optically exciting carriers that modify the refractive index in a conventional semiconductor wafer. Through use of birefringent retarders surrounding the wafer, the integrating response of the rapidly excited but persistent carriers is differentiated by probing with two polarization-encoded time-staggered signal replicas that are recombined to interfere destructively.

42 ENGINEERING↗

Single-shot optical recorder with sub-picosecond resolution and scalable record length on a semiconductor wafer

In this study, we demonstrate a novel, single-shot recording technology for transient optical signals. A resolution of 0.4 ps over a record length of 54 ps was demonstrated. Here, a pump pulse crossing through a signal samples a diagonal “slice” of space–time, enabling a camera to record spatially the time content of the signal. Unlike related X (2) -based cross-correlation techniques, here the signal is sampled through optically pumped carriers that modify the refractive index of a silicon wafer. Surrounding the wafer with birefringent retarders enables two time-staggered, orthogonally polarized signal copies to probe the wafer. Recombining the copies at a final crossed polarizer destructively interferes with them, except during the brief stagger window, where a differential phase shift is incurred. This enables the integrating response of the rapidly excited but persistent carriers to be optically differentiated. Lastly, this sampling mechanism has several advantages that enable scaling to long record lengths, including making use of large, inexpensive semiconductor wafers, eliminating the need for phase matching, broad insensitivity to the spectral and angular properties of the pump, and overall hardware simplicity.

42 ENGINEERING↗

HipGISAXS : a high-performance computing code for simulating grazing-incidence X-ray scattering data

This article describes the development of a flexible grazing-incidence small-angle X-ray scattering (GISAXS) simulation code in the framework of the distorted wave Born approximation that effectively utilizes the parallel processing power provided by graphics processors and multicore processors. The code, entitled High-Performance GISAXS , computes the GISAXS image for any given superposition of user-defined custom shapes or morphologies in a material and for various grazing-incidence angles and sample orientations. These capabilities permit treatment of a wide range of possible sample structures, including multilayered polymer films and nanoparticles on top of or embedded in a substrate or polymer film layers. In cases where the material displays regions of significant refractive index contrast, an algorithm has been implemented to perform a slicing of the sample and compute the averaged refractive index profile to be used as the reference geometry of the unperturbed system. A number of case studies are presented, which demonstrate good agreement with the experimental data for a variety of polymer and hybrid polymer/nanoparticle composite materials. The parallelized simulation code is well suited for addressing the analysis efforts required by the increasing amounts of GISAXS data being produced by high-speed detectors and ultrafast light sources.

Chemistry↗

Deciphering mineralogical changes and carbonation development during hydration and ageing of a consolidated ternary blended cement paste

To understand the main properties of cement, a ubiquitous material, a sound description of its chemistry and mineralogy, including its reactivity in aggressive environments and its mechanical properties, is vital. In particular, the porosity distribution and associated sample carbonation, both of which affect cement's properties and durability, should be quantified accurately, and their kinetics and mechanisms of formation known both in detail and in situ . However, traditional methods of cement mineralogy analysis ( e.g. chemical mapping) involve sample preparation ( e.g. slicing) that can be destructive and/or expose cement to the atmosphere, leading to preparation artefacts ( e.g. dehydration). In addition, the kinetics of mineralogical development during hydration, and associated porosity development, cannot be examined. To circumvent these issues, X-ray diffraction computed tomography (XRD-CT) has been used. This allowed the mineralogy of ternary blended cement composed of clinker, fly ash and blast furnace slag to be deciphered. Consistent with previous results obtained for both powdered samples and dilute systems, it was possible, using a consolidated cement paste (with a water-to-solid ratio akin to that used in civil engineering), to determine that the mineralogy consists of alite (only detected in the in situ hydration experiment), calcite, calcium silicate hydrates (C-S-H), ettringite, mullite, portlandite, and an amorphous fraction of unreacted slag and fly ash. Mineralogical evolution during the first hydration steps indicated fast ferrite reactivity. Insights were also gained into how the cement porosity evolves over time and into associated spatially and time-resolved carbonation mechanisms. It was observed that macroporosity developed in less than 30 h of hydration, with pore sizes reaching about 100–150 µm in width. Carbonation was not observed for this time scale, but was found to affect the first 100 µm of cement located around macropores in a sample cured for six months. Regarding this carbonation, the only mineral detected was calcite.

36 MATERIALS SCIENCE↗

3-dimensional imaging at nanometer resolutions

An apparatus and method for enabling precise, 3-dimensional, photoactivation localization microscopy (PALM) using selective, two-photon activation of fluorophores in a single z-slice of a sample in cooperation with time-gated imaging for reducing the background radiation from other image planes to levels suitable for single-molecule detection and spatial location, are described.

Werner, James H↗

Radiochemical Method for Characterization of the Filter Cartridges from the IEA-R1 Reactor - 16324

The filter cartridges used in water purification system of the IEA-R1 research reactor become radioactive waste after the end of their useful life. The characterization of this waste is one step in their management, which aims at identifying and quantifying the radionuclides present, including those known as 'difficult to measure' (DTM) radionuclides. Wastes from nuclear reactors contain fission and activation products and transuranic elements, only few of them emitting gamma radiation measurable by simple gamma spectrometry methods. In routine waste management activities, the concentrations of the DTM can only be estimated by indirect methods such as scaling factors. The method of the scaling factors uses empirically determined proportions between the concentrations of DTM radionuclides and that of easily measurable gamma emitters called key nuclides (KN), to calculate DTM concentrations. Determining the scaling factors for the filter cartridges is a hard task when the number of samples is large, not only because the preparation of samples is difficult but also because the number of radionuclides to analyze is large. If it can be demonstrated that DTM and KN are both distributed evenly in the filters, less samples from each filter are necessary, reducing lab work. The aim of this paper is to present the results of the assessment of homogeneity along the filter cartridges by gamma spectrometry of chemically reduced samples. Five thin slices of five filters were burnt and the ashes quantitatively dissolved and the activity concentration of the solutions determined by gamma spectrometry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structure from Motion Photogrammetry and Micro X-Ray Computed Tomography 3-D Reconstruction Data Fusion for Non-Destructive Conservation Documentation of Lunar Samples

Our team is developing a modern, cross-disciplinary approach to documentation and preservation of astromaterials, specifically lunar and meteorite samples stored at the Johnson Space Center (JSC) Lunar Sample Laboratory Facility. Apollo Lunar Sample 60639, collected as part of rake sample 60610 during the 3rd Extra-Vehicular Activity of the Apollo 16 mission in 1972, served as the first NASA-preserved lunar sample to be examined by our team in the development of a novel approach to internal and external sample visualization. Apollo Sample 60639 is classified as a breccia with a glass-coated side and pristine mare basalt and anorthosite clasts. The aim was to accurately register a 3-dimensional Micro X-Ray Computed Tomography (XCT)-derived internal composition data set and a Structure-From-Motion (SFM) Photogrammetry-derived high-fidelity, textured external polygonal model of Apollo Sample 60639. The developed process provided the means for accurate, comprehensive, non-destructive visualization of NASA's heritage lunar samples. The data products, to be ultimately served via an end-user web interface, will allow researchers and the public to interact with the unique heritage samples, providing a platform to "slice through" a photo-realistic rendering of a sample to analyze both its external visual and internal composition simultaneously.

Beaulieu, K. R.↗

Monte Carlo Simulation of Electron Interactions in an MeV-STEM for Thick Frozen Biological Sample Imaging

A variety of volume electron microscopy techniques have been developed to visualize thick biological samples. However, the resolution is limited by the sliced section thickness (>30–60 nm). To preserve biological samples in a hydrated state, cryo-focused ion beam scanning electron microscopy has been developed, providing nm resolutions. However, this method is time-consuming, requiring 15–20 h to image a 10 μm thick sample with an 8 nm slice thickness. There is a pressing need for a method that allows the rapid and efficient study of thick biological samples while maintaining nanoscale resolution. The remarkable ability of mega-electron-volt (MeV) electrons to penetrate thick biological samples, even exceeding 10 μm in thickness, while maintaining nanoscale resolution, positions MeV-STEM as a suitable microscopy tool for such applications. Our research delves into understanding the interactions between MeV electrons and frozen biological specimens through Monte Carlo simulations. Single elastic scattering, plural elastic scattering, single inelastic scattering, and plural inelastic scattering events have been simulated. The electron trajectories, the beam profile, and the intensity change of electrons in each category have been investigated. Additionally, the effects of the detector collection angle and the focal position of the electron beam were investigated. As electrons penetrated deeper into the specimen, single and plural elastic scattered electrons diminished, and plural inelastic scattered electrons became dominant, and the beam profile became wider. Even after 10 μm of the specimen, 42% of the MeV electrons were collected within 10 mrad. This confirms that MeV-STEM can be employed to study thick biological samples.

electron specimen interaction↗

Imprints of gravitational lensing in the Planck cosmic microwave background data at the location of W I S E × SCOS galaxies

We detect weak gravitational lensing of the cosmic microwave background at the location of the WISE × SuperCOSMOS (WISE × SCOS) galaxies using the publicly available Planck lensing convergence map. By stacking the lensing convergence map at the position of 12.4 million galaxies in the redshift range 0.1 ≤ $\mathscr{z}$ ≤ 0.345, we find the average mass of the galaxies to be $M_{200_{crit}}$ = 6.25 ± 0.6 × 10 12 M$_⊙$. The null hypothesis of no lensing is rejected at a significance of 17$σ$ . We split the galaxy sample into three redshift slices, each containing ~4.1 million objects, and obtain lensing masses in each slice of 4.18 ± 0.8, 6.93 ± 0.9, and 18.84 ± 1.2 × 10 12 M$_⊙$. Our results suggest a redshift evolution of the galaxy sample masses, but this apparent increase might be due to the preferential selection of intrinsically luminous sources at high redshifts. The recovered mass of the stacked sample is reduced by 28% when we remove the galaxies in the vicinity of galaxy clusters with mass $M_{200_{crit}}$ = 2 × 10 14 M ⊙ . We forecast that upcoming CMB surveys can achieve 5% galaxy mass constraints over sets of 12.4 million galaxies with $M_{200_{crit}}$ = 1 × 10 12 M ⊙ at $z$ = 1 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Redshifts for a sample of fainter galaxies in the first CfA survey slice

Redshifts were measured for 93 of the 94 galaxies in the Zwicky-Nilson merged catalog with the value of m(B/01) between 15.5 and 15.7 and with right ascension alpha between 8(h) and 17(h) and declination delta between 29 and 30 deg. This region is within the one covered by the first slice of the CfA (Center for Astrophysics) survey. The galaxies reinforce features already visible in the earlier survey.

Thorstensen, J. R.↗