Search NASA⌕ Search

SEARCH · Search NASA

Results for “slice sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

All optical sampling by slanted light interrogation for cross-correlated encoded recording (slicer)

Single-shot transient optical signals are recorded in a time regime of picoseconds to nanosecond. An auxiliary pump beam is crossed through the signal to sample a diagonal ‘slice’ of space-time, analogous to a rolling shutter. The slice is then imaged onto an ordinary camera, where the recorded spatial trace is a direct representation of the time content of the signal. The pump samples the signal by optically exciting carriers that modify the refractive index in a conventional semiconductor wafer. Through use of birefringent retarders surrounding the wafer, the integrating response of the rapidly excited but persistent carriers is differentiated by probing with two polarization-encoded time-staggered signal replicas that are recombined to interfere destructively.

42 ENGINEERING↗

Single-shot optical recorder with sub-picosecond resolution and scalable record length on a semiconductor wafer

In this study, we demonstrate a novel, single-shot recording technology for transient optical signals. A resolution of 0.4 ps over a record length of 54 ps was demonstrated. Here, a pump pulse crossing through a signal samples a diagonal “slice” of space–time, enabling a camera to record spatially the time content of the signal. Unlike related X (2) -based cross-correlation techniques, here the signal is sampled through optically pumped carriers that modify the refractive index of a silicon wafer. Surrounding the wafer with birefringent retarders enables two time-staggered, orthogonally polarized signal copies to probe the wafer. Recombining the copies at a final crossed polarizer destructively interferes with them, except during the brief stagger window, where a differential phase shift is incurred. This enables the integrating response of the rapidly excited but persistent carriers to be optically differentiated. Lastly, this sampling mechanism has several advantages that enable scaling to long record lengths, including making use of large, inexpensive semiconductor wafers, eliminating the need for phase matching, broad insensitivity to the spectral and angular properties of the pump, and overall hardware simplicity.

42 ENGINEERING↗

HipGISAXS : a high-performance computing code for simulating grazing-incidence X-ray scattering data

This article describes the development of a flexible grazing-incidence small-angle X-ray scattering (GISAXS) simulation code in the framework of the distorted wave Born approximation that effectively utilizes the parallel processing power provided by graphics processors and multicore processors. The code, entitled High-Performance GISAXS , computes the GISAXS image for any given superposition of user-defined custom shapes or morphologies in a material and for various grazing-incidence angles and sample orientations. These capabilities permit treatment of a wide range of possible sample structures, including multilayered polymer films and nanoparticles on top of or embedded in a substrate or polymer film layers. In cases where the material displays regions of significant refractive index contrast, an algorithm has been implemented to perform a slicing of the sample and compute the averaged refractive index profile to be used as the reference geometry of the unperturbed system. A number of case studies are presented, which demonstrate good agreement with the experimental data for a variety of polymer and hybrid polymer/nanoparticle composite materials. The parallelized simulation code is well suited for addressing the analysis efforts required by the increasing amounts of GISAXS data being produced by high-speed detectors and ultrafast light sources.

Chemistry↗

Deciphering mineralogical changes and carbonation development during hydration and ageing of a consolidated ternary blended cement paste

To understand the main properties of cement, a ubiquitous material, a sound description of its chemistry and mineralogy, including its reactivity in aggressive environments and its mechanical properties, is vital. In particular, the porosity distribution and associated sample carbonation, both of which affect cement's properties and durability, should be quantified accurately, and their kinetics and mechanisms of formation known both in detail and in situ . However, traditional methods of cement mineralogy analysis ( e.g. chemical mapping) involve sample preparation ( e.g. slicing) that can be destructive and/or expose cement to the atmosphere, leading to preparation artefacts ( e.g. dehydration). In addition, the kinetics of mineralogical development during hydration, and associated porosity development, cannot be examined. To circumvent these issues, X-ray diffraction computed tomography (XRD-CT) has been used. This allowed the mineralogy of ternary blended cement composed of clinker, fly ash and blast furnace slag to be deciphered. Consistent with previous results obtained for both powdered samples and dilute systems, it was possible, using a consolidated cement paste (with a water-to-solid ratio akin to that used in civil engineering), to determine that the mineralogy consists of alite (only detected in the in situ hydration experiment), calcite, calcium silicate hydrates (C-S-H), ettringite, mullite, portlandite, and an amorphous fraction of unreacted slag and fly ash. Mineralogical evolution during the first hydration steps indicated fast ferrite reactivity. Insights were also gained into how the cement porosity evolves over time and into associated spatially and time-resolved carbonation mechanisms. It was observed that macroporosity developed in less than 30 h of hydration, with pore sizes reaching about 100–150 µm in width. Carbonation was not observed for this time scale, but was found to affect the first 100 µm of cement located around macropores in a sample cured for six months. Regarding this carbonation, the only mineral detected was calcite.

36 MATERIALS SCIENCE↗

3-dimensional imaging at nanometer resolutions

An apparatus and method for enabling precise, 3-dimensional, photoactivation localization microscopy (PALM) using selective, two-photon activation of fluorophores in a single z-slice of a sample in cooperation with time-gated imaging for reducing the background radiation from other image planes to levels suitable for single-molecule detection and spatial location, are described.

Werner, James H↗

Radiochemical Method for Characterization of the Filter Cartridges from the IEA-R1 Reactor - 16324

The filter cartridges used in water purification system of the IEA-R1 research reactor become radioactive waste after the end of their useful life. The characterization of this waste is one step in their management, which aims at identifying and quantifying the radionuclides present, including those known as 'difficult to measure' (DTM) radionuclides. Wastes from nuclear reactors contain fission and activation products and transuranic elements, only few of them emitting gamma radiation measurable by simple gamma spectrometry methods. In routine waste management activities, the concentrations of the DTM can only be estimated by indirect methods such as scaling factors. The method of the scaling factors uses empirically determined proportions between the concentrations of DTM radionuclides and that of easily measurable gamma emitters called key nuclides (KN), to calculate DTM concentrations. Determining the scaling factors for the filter cartridges is a hard task when the number of samples is large, not only because the preparation of samples is difficult but also because the number of radionuclides to analyze is large. If it can be demonstrated that DTM and KN are both distributed evenly in the filters, less samples from each filter are necessary, reducing lab work. The aim of this paper is to present the results of the assessment of homogeneity along the filter cartridges by gamma spectrometry of chemically reduced samples. Five thin slices of five filters were burnt and the ashes quantitatively dissolved and the activity concentration of the solutions determined by gamma spectrometry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monte Carlo Simulation of Electron Interactions in an MeV-STEM for Thick Frozen Biological Sample Imaging

A variety of volume electron microscopy techniques have been developed to visualize thick biological samples. However, the resolution is limited by the sliced section thickness (>30–60 nm). To preserve biological samples in a hydrated state, cryo-focused ion beam scanning electron microscopy has been developed, providing nm resolutions. However, this method is time-consuming, requiring 15–20 h to image a 10 μm thick sample with an 8 nm slice thickness. There is a pressing need for a method that allows the rapid and efficient study of thick biological samples while maintaining nanoscale resolution. The remarkable ability of mega-electron-volt (MeV) electrons to penetrate thick biological samples, even exceeding 10 μm in thickness, while maintaining nanoscale resolution, positions MeV-STEM as a suitable microscopy tool for such applications. Our research delves into understanding the interactions between MeV electrons and frozen biological specimens through Monte Carlo simulations. Single elastic scattering, plural elastic scattering, single inelastic scattering, and plural inelastic scattering events have been simulated. The electron trajectories, the beam profile, and the intensity change of electrons in each category have been investigated. Additionally, the effects of the detector collection angle and the focal position of the electron beam were investigated. As electrons penetrated deeper into the specimen, single and plural elastic scattered electrons diminished, and plural inelastic scattered electrons became dominant, and the beam profile became wider. Even after 10 μm of the specimen, 42% of the MeV electrons were collected within 10 mrad. This confirms that MeV-STEM can be employed to study thick biological samples.

electron specimen interaction↗

Imprints of gravitational lensing in the Planck cosmic microwave background data at the location of W I S E × SCOS galaxies

We detect weak gravitational lensing of the cosmic microwave background at the location of the WISE × SuperCOSMOS (WISE × SCOS) galaxies using the publicly available Planck lensing convergence map. By stacking the lensing convergence map at the position of 12.4 million galaxies in the redshift range 0.1 ≤ $\mathscr{z}$ ≤ 0.345, we find the average mass of the galaxies to be $M_{200_{crit}}$ = 6.25 ± 0.6 × 10 12 M$_⊙$. The null hypothesis of no lensing is rejected at a significance of 17$σ$ . We split the galaxy sample into three redshift slices, each containing ~4.1 million objects, and obtain lensing masses in each slice of 4.18 ± 0.8, 6.93 ± 0.9, and 18.84 ± 1.2 × 10 12 M$_⊙$. Our results suggest a redshift evolution of the galaxy sample masses, but this apparent increase might be due to the preferential selection of intrinsically luminous sources at high redshifts. The recovered mass of the stacked sample is reduced by 28% when we remove the galaxies in the vicinity of galaxy clusters with mass $M_{200_{crit}}$ = 2 × 10 14 M ⊙ . We forecast that upcoming CMB surveys can achieve 5% galaxy mass constraints over sets of 12.4 million galaxies with $M_{200_{crit}}$ = 1 × 10 12 M ⊙ at $z$ = 1 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SHAPE EVOLUTION OF MASSIVE EARLY-TYPE GALAXIES: CONFIRMATION OF INCREASED DISK PREVALENCE AT z > 1

We use high-resolution K-band VLT/HAWK-I imaging over 0.25 deg{sup 2} to study the structural evolution of massive early-type galaxies since z {approx} 2. Mass-selected samples, complete down to log(M/M {sub Sun }) {approx} 10.7 such that 'typical' (L*) galaxies are included at all redshifts, are drawn from pre-existing photometric redshift surveys. We then separate the samples into different redshift slices and classify them as late- or early-type galaxies on the basis of their specific star formation rate. Axis-ratio measurements for the {approx}400 early-type galaxies in the redshift range 0.6 < z < 1.8 are accurate to 0.1 or better. The projected axis-ratio distributions are then compared with lower redshift samples. We find strong evidence for evolution of the population properties: early-type galaxies at z > 1 are, on average, flatter than at z < 1 and the median projected axis ratio at a fixed mass decreases with redshift. However, we also find that at all epochs z {approx}< 2, the most massive early-type galaxies (log(M/M {sub Sun }) > 11.3) are the roundest, with a pronounced lack of galaxies that are flat in projection. Merging is a plausible mechanism that can explain both results: at all epochs, merging is required for early-type galaxies to grow beyond log(M/M {sub Sun }) {approx} 11.3, and all early types over time gradually and partially lose their disk-like characteristics.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-System Verification of Registrations for Image-Guided Radiotherapy in Clinical Trials

Purpose: To provide quantitative information on the image registration differences from multiple systems for image-guided radiotherapy (IGRT) credentialing and margin reduction in clinical trials. Methods and Materials: Images and IGRT shift results from three different treatment systems (Tomotherapy Hi-Art, Elekta Synergy, Varian Trilogy) have been sent from various institutions to the Image-Guided Therapy QA Center (ITC) for evaluation for the Radiation Therapy Oncology Group (RTOG) trials. Nine patient datasets (five head-and-neck and four prostate) were included in the comparison, with each patient having 1-4 daily individual IGRT studies. In all cases, daily shifts were re-calculated by re-registration of the planning CT with the daily IGRT data using three independent software systems (MIMvista, FocalSim, VelocityAI). Automatic fusion was used in all calculations. The results were compared with those submitted from institutions. Similar regions of interest (ROIs) and same initial positions were used in registrations for inter-system comparison. Different slice spacings for CBCT sampling and different ROIs for registration were used in some cases to observe the variation of registration due to these factors. Results: For the 54 comparisons with head-and-neck datasets, the absolute values of differences of the registration results between different systems were 2.6 {+-} 2.1 mm (mean {+-} SD; range 0.1-8.6 mm, left-right [LR]), 1.7 {+-} 1.3 mm (0.0-4.9 mm, superior-inferior [SI]), and 1.8 {+-} 1.1 mm (0.1-4.0 mm, anterior-posterior [AP]). For the 66 comparisons in prostate cases, the differences were 1.1 {+-} 1.0 mm (0.0-4.6 mm, LR), 2.1 {+-} 1.7 mm (0.0-6.6 mm, SI), and 2.0 {+-} 1.8 mm (0.1-6.9 mm, AP). The differences caused by the slice spacing variation were relatively small, and the different ROI selections in FocalSim and MIMvista also had limited impact. Conclusion: The extent of differences was reported when different systems were used for image registration. Careful examination and quality assurance of the image registration process are crucial before considering margin reduction using IGRT in clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regularization approach for tomosynthesis X-ray inspection

X-ray inspection is intended to be used as an escalation technique for inspection of carbon fiber reinforced plastics (CFRP) in aerospace applications, especially in case of unclear indications from ultrasonic or other NDT modalities. Due to their large dimensions, most aerospace components cannot be scanned by conventional computed tomography. In such cases, X-ray Laminography may be applied, allowing a pseudo 3D slice-by-slice reconstruction of the sample with Tomosynthesis. However, due to the limited angle acquisition geometry, reconstruction artifacts arise, especially at surfaces parallel to the imaging plane. To regularize the Tomosynthesis approach, we propose an additional prescan of the object to detect outer sample surfaces. We recommend the use of contrasted markers which are temporarily attached to the sample surfaces. The depth position of the markers is then derived from that prescan. As long as the sample surface remains simple, few markers are required to fit the respective object surfaces. The knowledge about this surface may then be used to regularize the final Tomosynthesis reconstruction, performed with markerless projections. Eventually, it can also serve as prior information for an ART reconstruction or to register a CAD model of the sample. The presented work is carried out within the European FP7 project QUICOM. We demonstrate the proposed approach within a simulation study applying an acquisition geometry suited for CFRP part inspection. A practical verification of the approach is planned later in the project.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distribution of Te inclusions in a CdZnTe wafer and their effects on the electrical properties of fabricated devices

We quantified the size and concentration of Te-inclusions along the lateral- and the growth-directions of a {approx}6 mm thick wafer cut axially along the center of a CdZnTe ingot. We fabricated devices, selecting samples from the center slice outward in both directions, and then tested their response to incident x-rays. We employed, in concert, an automated IR transmission microscopic system and a highly collimated synchrotron X-ray source that allowed us to acquire and correlate comprehensive information on Te inclusions and other defects to assess the material factors limiting the performance of CdZnTe detectors.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Resolving 500 nm axial separation by multi-slice X-ray ptychography

Multi-slice X-ray ptychography offers an approach to achieve images with a nanometre-scale resolution from samples with thicknesses larger than the depth of field of the imaging system by modeling a thick sample as a set of thin slices and accounting for the wavefront propagation effects within the specimen. Here, we present an experimental demonstration that resolves two layers of nanostructures separated by 500 nm along the axial direction, with sub-10 nm and sub-20 nm resolutions on two layers, respectively. Fluorescence maps are simultaneously measured in the multi-modality imaging scheme to assist in decoupling the mixture of low-spatial-frequency features across different slices. The enhanced axial sectioning capability using correlative signals obtained from multi-modality measurements demonstrates the great potential of the multi-slice ptychography method for investigating specimens with extended dimensions in 3D with high resolution.

36 MATERIALS SCIENCE↗

Formation of novel morphologies of aragonite induced by inorganic template

Graphical abstract: Glass-slices were used as a template to induce formation and assembly of aragonite. Different morphologies, such as hemisphere, twinborn hemisphere and flower-shaped particles, were produced by direction of the glass-slices. Highlights: {yields} Glass-slices were used as a template to induce formation and assembly of aragonite. {yields} Hemisphere, twinborn hemisphere and flower-shaped particles were produced by direction of the glass-slices. {yields} Planes were always appeared in these as-synthesized samples. {yields} Thermodynamic theory was applied to explain the production of the aragonite. -- Abstract: A glass-slice was used as a template to induce formation and assembly of aragonite. Thermodynamic theory was applied to explain the production of the aragonite. Transformation of three-dimensional nucleation to template-based two-dimensional surface nucleation caused the production of aragonite. Hemisphere, twinborn hemisphere and flower-shaped particles were produced by direction of the glass-slices. Planes were always appeared in these as-synthesized samples because the nucleation and the growth of these samples were adsorbed at the surfaces of the glass-slices. The formation mechanism of the as-formed sample was proposed. Compared with organic template, the present study provides a facile method to apply inorganic template to prepare functional materials.

36 MATERIALS SCIENCE↗

13 TeV pp collisions, SM type, PYTHIA8 generator: tev13pp_pythia8_qcd_jz

Filtered QCD multijet events (2->2 process) using antiKT6 filters. PDF: LHAPDF6:NNPDF23_lo_as_0130_qed. The sample was created using the Pythia8 tune Tune:pp = 14, similar to ATLAS. The sample recreates ATLAS JZ1-JZ8 slices (without re-weighting). The cross sections are reported inside the files. Pythia8 corresponds to the ATLAS version used to create such samples.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetoelastic transition and magnetocaloric effect in induction melted Fe 100-x Rh x bulk alloys with x = 50, 51

Magnetoelastic transitions (METs) in bulk in nearly equiatomic Fe-Rh alloys produced by arc melting may show poor reproducibility related to insufficient chemical homogeneity and presence of impurity phases in variable concentrations. To better understand the synthesis conditions that reliably yield bulk FeRh materials with reproducible MET characteristics, Fe 100-x Rh x alloys with x = 50, 50.5 and 51 at. % were prepared by induction melting and thermal annealing under identical conditions. The fabricated samples were cut into several slices, followed by characterization of METs in each of the slices using isothermal and isofield magnetization measurements, differential scanning calorimetry, and direct measurements of the magnetocaloric effect. All of the slices exhibit METs between the AFM and FM states, but the transitions are abrupt with nearly the same change of magnetization, ΔM, when x = 50.5 and 51, whereas for the x = 50 alloy the transition spreads over a wide temperature interval and ΔM may fluctuate by as much as 10 % from one specimen to another. A comparison of the magnetocaloric responses of x = 50 and 51 materials is presented. The clearly different effect of the magnetic field on the transition in both directions leads to significant differences in the reversibility and maximum values of the magnetic field-induced entropy and adiabatic temperature changes, as well as average hysteresis losses. In terms of reproducibility, our results suggest that induction melting is a more appropriate technique to prepare these binary alloys.

36 MATERIALS SCIENCE↗

Effect of nanoscale flows on the surface structure of nanoporous catalysts

Here, the surface structure and composition of a multi-component catalyst are critical factors in determining its catalytic performance. The surface composition can depend on the local pressure of the reacting species, leading to the possibility that the flow through a nanoporous catalyst can affect its structure and reactivity. Here, we explore this possibility for oxidation reactions on nanoporous gold, an AgAu bimetallic catalyst. We use microscopy and digital reconstruction to obtain the morphology of a two-dimensional slice of a nanoporous gold sample. Using lattice Boltzmann fluid dynamics simulations along with thermodynamic models based on first-principles total-energy calculations, we show that some sections of this sample have low local O 2 partial pressures when exposed to reaction conditions, which leads to a pure Au surface in these regions, instead of the active bimetallic AgAu phase. We also explore the effect of temperature on the surface structure and find that moderate temperatures (≈300–450 K) should result in the highest intrinsic catalytic performance, in apparent agreement with experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The clustering of galaxies in the completed SDSS-III Baryon Oscillation Spectroscopic Survey: tomographic BAO analysis of DR12 combined sample in configuration space

We perform a tomographic baryon acoustic oscillations (BAOs) analysis using the two-point galaxy correlation function measured from the combined sample of Baryon Oscillation Spectroscopic Survey Data Release 12 (BOSS DR12), which covers the redshift range of 0.2 < z < 0.75. Upon splitting the sample into multiple overlapping redshift slices to extract the redshift information of galaxy clustering, we obtain a measurement of DA(z)/r d and H(z)r d at nine effective redshifts with the full covariance matrix calibrated using MultiDark-Patchy mock catalogues. Using the reconstructed galaxy catalogues, we obtain the precision of 1.3–2.2 percent for DA(z)/r d and 2.1–6.0 percent for H(z)r d . To quantify the gain from the tomographic information, we compare the constraints on the cosmological parameters using our nine-bin BAO measurements, the consensus three-bin BAO and redshift space distortion measurements at three effective redshifts in Alam et al., and the non-tomographic (one-bin) BAO measurement at a single effective redshift. Comparing the nine-bin with one-bin constraint result, it can improve the dark energy Figure of Merit by a factor of 1.24 for the Chevallier–Polarski–Linder parametrization for equation-of-state parameter w DE . The errors of w 0 and w a from nine-bin constraints are slightly improved when compared to the three-bin constraint result.

79 ASTRONOMY AND ASTROPHYSICS↗