Search NASA⌕ Search

SEARCH · Search NASA

Results for “small sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Superconducting Effects in Optimization of Magnetic Penetration Thermometers for X-ray Microcalorimeters

We have made high resolution x-ray microcalorimeters using superconducting MoAu bilayers and Nb meander coils. The temperature sensor is a Magnetic Penetration Thermometer (MPT). Operation is similar to metallic magnetic calorimeters, but instead of the magnetic susceptibility of a paramagnetic alloy, we use the diamagnetic response of the superconducting MoAu to sense temperature changes in an x-ray absorber. Flux-temperature responsivtty can be large for small sensor heat capacity, with enough dynamic range for applications. We find models of observed flux-temperature curves require several effects to explain flux penetration or expulsion in the microscopic devices. The superconductor is non-local, with large coherence length and weak pinning of flux. At lowest temperatures, behavior is dominated by screening currents that vary as a result of the temperature dependence of the magnetic penetration depth, modified by the effect of the nonuniformity of the applied field occurring on a scale comparable to the coherence length. In the temperature regime where responslvity is greatest, spadal variations in the order parameter become important: both local variations as flux enters/leaves the film and an intermediate state is formed, and globally as changing stability of the electrical circuit creates a Meissner transition and flux is expelled/penetrates to minimize free energy.

Stevenson, Thomas R.↗

Development of Miniaturized Optimized Smart Sensors (MOSS) for space plasmas

The cost of space plasma sensors is high for several reasons: (1) Most are one-of-a-kind and state-of-the-art, (2) the cost of launch to orbit is high, (3) ruggedness and reliability requirements lead to costly development and test programs, and (4) overhead is added by overly elaborate or generalized spacecraft interface requirements. Possible approaches to reducing costs include development of small 'sensors' (defined as including all necessary optics, detectors, and related electronics) that will ultimately lead to cheaper missions by reducing (2), improving (3), and, through work with spacecraft designers, reducing (4). Despite this logical approach, there is no guarantee that smaller sensors are necessarily either better or cheaper. We have previously advocated applying analytical 'quality factors' to plasma sensors (and spacecraft) and have begun to develop miniaturized particle optical systems by applying quantitative optimization criteria. We are currently designing a Miniaturized Optimized Smart Sensor (MOSS) in which miniaturized electronics (e.g., employing new power supply topology and extensive us of gate arrays and hybrid circuits) are fully integrated with newly developed particle optics to give significant savings in volume and mass. The goal of the SwRI MOSS program is development of a fully self-contained and functional plasma sensor weighing 1 lb and requiring 1 W. MOSS will require only a typical spacecraft DC power source (e.g., 30 V) and command/data interfaces in order to be fully functional, and will provide measurement capabilities comparable in most ways to current sensors.

Young, D. T.↗

Global Precipitation Measurement - Report 9 Core Coverage Trade Space Analysis

This paper summarizes the GPM-Core coverage trade space analysis. The goal of this analysis was to determine the GPM-Core sensitivity to changes in altitude and inclination for the three onboard instruments: the radiometer, the KU band radar and the KA band radar. This study will enable a better choice of the nominal GPM-Core orbit as well as the optimal size of the maintenance box (+/-1 km, +/-5 km..). For this work, we used two different figures-of-merit: (1) the time required to cover 100% of the +/-65 deg latitude band and (2) the coverage obtained for a given propagation time (7 days and 30 days). The first figure-of-merit is used for the radiometer as it has a sensor cone half-angle between 3 to 5 times bigger than the radars. Thus, we anticipate that for this instrument the period of the orbit (i.e. altitude) will be the main driver and that the 100% coverage value will be reached within less than a week. The second figure-of-merit is used for the radar instruments as they have small sensor cone half-angle and will, in some cases, never reach the 100% coverage threshold point.

Mailhe, Laurie↗

Autonomous Cryogenic Leak Detector for Improving Launch Site Operations

NASA, military, and commercial satellite users need launch services that are highly reliable, less complex, easier to test, and cost effective. This project has developed a tapered optical fiber sensor for detecting hydrogen. The invention involves incorporating chemical indicators on the tapered end of an optical fiber using organically modified silicate nanomaterials. The Hazardous Gas Detection Lab (HGDL) at Kennedy Space Center is involved in the design and development of instrumentation that can detect and qualify various mission-critical chemicals. Historically, hydrogen, helium, nitrogen, oxygen, and argon are the first five gases of HGDL focus. The use of these cryogenic fluids in the area of propulsion offers challenges. Due to their extreme low temperatures, these fluids induce contraction of the materials they contact, a potential cause of leakage. Among them, hydrogen is of particular concern. Small sensors are needed in multiple locations without adding to the structural weight. The most vulnerable parts of the engine are the connection flanges on the transfer lines, which have to support cycles of large thermal amplitude. The thermal protection of the engine provides a closed area, increasing the likelihood of an explosive atmosphere. Thus, even a small leak represents an unacceptable hazardous condition during loading operations, in flight, or after an aborted launch. Tapered fibers were first fabricated from 1/1.3-mm core/cladding (silica/ plastic) optical fibers. Typically a 1-ft (approx. 30- cm) section of the 1-mm fiber is cut from the bundle and marked with a pen into five 2-.-in. (.5.7-cm) sections. A propane torch is applied at every alternate mark to burn the jacket and soften the glass core. While the core is softening, the two ends of the fiber are pulled apart slowly to create fine tapers of .- to .-in. (.6- to 12-mm) long on the 1-mm optical fiber. Following this, the non-tapered ends of the fibers are polished to a 0.3-micron finish. Then these fibers were coated with indicators sensitive to hydrogen. The tapered hydrogen detection system with its unique flexibility is the only system that can be placed in many locations inside the vehicles and detect the exact location of leaks, saving millions of dollars for launch vehicle industries.

Goswami, Kisholoy↗

Noninvasive Sensor for Measuring Muscle Metabolism During Exercise

The measurement of oxygen uptake (VO2) and lactate threshold (LT) are utilized to assess changes in aerobic capacity and the efficacy of exercise countermeasures in astronauts. During extravehicular activity (EVA), real-time knowledge of VO2 and relative work intensity can be used to monitor crew activity levels and organize tasks to reduce the cumulative effects of fatigue. Currently VO2 and LT are determined with complicated measurement techniques that require sampling of expired ventilatory gases, which may not be accurate in enclosed, oxygen-rich environments such as the EVA suit. The UMMS team has developed a novel near infrared spectroscopic (NIRS) system which noninvasively, simultaneously and continuously measures muscle oxygen tension, oxygen saturation, pH (pHm), and hematocrit from a small sensor placed on the leg. This system is unique in that it allows accurate, absolute measurement of these parameters in the thigh muscle by correcting spectra for the interference from skin pigment and fat. These parameters can be used to estimate VO2 and LT. A preliminary evaluation of the system s capabilities was performed in the NASA JSC Exercise Physiology Lab.

Soller, B. R.↗

Design of High Resolution Soft X-Ray Microcalorimeters Using Magnetic Penetration Thermometers

We have designed high-resolution soft x-ray microcalorimeters using magnetic penetration thermometers (MPTs) in an array of pixels covering a total of 2 square centimeters to have a resolving power of 300 at energies around 300 eV. This performance is desirable for studying the soft x-ray background from the warm hot intergalactic medium. MPT devices have small sensor heat capacity and high responsivities, which makes them excellent detector technology for attempting to attain sub-eV resolution. We are investigating the feasibility of pixels with absorbers that are 625 x 625 square micrometers, up to 1 x 1 square millimeters in area and 0.35 micrometer thick and thinner. Our tests have shown that suspended gold absorbers 0.35 micrometers thick (RRR = 6.7) are feasible to fabricate. We modeled the thermal diffusion from such thin gold over the size of a 625 x 625 square micrometer absorber, and conclude that the effect of the thermalization on the resolution of a 300 eV photon is an additional approximately 0.2 eV FWHM of broadening. We discuss the thermal effects of small absorber attachment sterns on solid substrate, as well as considerations for multiplexed readout. We will present the progress we have made towards building and testing this soft x-ray detector.

Busch. Sarah↗

Lightning detection from Space Science and Applications Team review

The various needs for lightning data that exist among potential users of satellite lightning data were identified and systems were defined which utilize the optical and radio frequency radiations from lightning to serve as the satellite based lightning mapper. Three teams worked interactively with NASA to develop a system concept. An assessment of the results may be summarized as follows: (1) a small sensor system can be easily designed to operate on a geostationary satellite that can provide the bulk of the real time user requirements; (2) radio frequency systems in space may be feasible but would be much larger and more costly; RF technology for this problem lags the optical technology by years; and (3) a hybrid approach (optical in space and RF on the ground) would provide the most complete information but is probably unreasonably complex and costly at this time.

Few, A. A., Jr.↗

Technology Directions for the 21st Century

Data compression is an important tool for reducing the bandwidth of communications systems, and thus for reducing the size, weight, and power of spacecraft systems. For data requiring lossless transmissions, including most science data from spacecraft sensors, small compression factors of two to three may be expected. Little improvement can be expected over time. For data that is suitable for lossy compression, such as video data streams, much higher compression factors can be expected, such as 100 or more. More progress can be expected in this branch of the field, since there is more hidden redundancy and many more ways to exploit that redundancy.

Crimi, Giles↗

Optical Scattering Characterization for the Glennan Microsystems Microscale Particulate Classifier

Small sensors that are tolerant to mechanically and thermally harsh environments present the possibility for in-situ particle characterization in propulsion, industrial, and planetary science applications. Under a continuing grant from the Glennan Microsystems Initiative to the Microgravity Fluids Physics Branch of the NASA-Glenn Research Center, a Microscale Particle Classifier (MiPAC) instrument is being developed. The MiPAC instrument will be capable of determining the size distribution of airborne particles from about 1 nm to 30 micrometers, and will provide partial information as to the concentration, charge state, shape, and structure of the particles, while being an order of magnitude smaller in size and lighter in weight than presently commercially available instruments. The portion of the instrument that will characterize the nm-range particles will employ electrical mobility techniques and is being developed under a separate grant to Prof. David Pui of the University of Minnesota. The portion of the instrument that will characterize the micrometer-size particles such as dirt, pollens, spores, molds, soot, and combustion aerosols will use light scattering techniques. The development of data analysis techniques to be employed in the light scattering portion of the instrument is covered by this grant.

Lock, James A.↗

Two Years of Chemical Sampling on Meridiani Planum by the Alpha Particle X-Ray Spectrometer Onboard the Mars Exploration Rover Opportunity

For over two terrestrial years, the Mars Exploration Rover Opportunity has been exploring the martian surface at Meridiani Planum using the Athena instrument payload [1], including the Alpha Particle X-Ray Spectrometer (APXS). The APXS has a small sensor head that is mounted on the robotic arm of the rover. The chemistry, mineralogy and morphology of selected samples were investigated by the APXS along with the Moessbauer Spectrometer (MB) and the Microscopic Imager (MI). The Rock Abrasion Tool (RAT) provided the possibility to dust and/or abrade rock surfaces down to several millimeters to expose fresh material for analysis. We report here on APXS data gathered along the nearly 6-kilometers long traverse in craters and plains of Meridiani.

Bruckner, J.↗

Active Piezoelectric Vibration Control of Subscale Composite Fan Blades

As part of the Fundamental Aeronautics program, researchers at NASA Glenn Research Center (GRC) are investigating new technologies supporting the development of lighter, quieter, and more efficient fans for turbomachinery applications. High performance fan blades designed to achieve such goals will be subjected to higher levels of aerodynamic excitations which could lead to more serious and complex vibration problems. Piezoelectric materials have been proposed as a means of decreasing engine blade vibration either through a passive damping scheme, or as part of an active vibration control system. For polymer matrix fiber composite blades, the piezoelectric elements could be embedded within the blade material, protecting the brittle piezoceramic material from the airflow and from debris. To investigate this idea, spin testing was performed on two General Electric Aviation (GE) subscale composite fan blades in the NASA GRC Dynamic Spin Rig Facility. The first bending mode (1B) was targeted for vibration control. Because these subscale blades are very thin, the piezoelectric material was surface-mounted on the blades. Three thin piezoelectric patches were applied to each blade two actuator patches and one small sensor patch. These flexible macro-fiber-composite patches were placed in a location of high resonant strain for the 1B mode. The blades were tested up to 5000 rpm, with patches used as sensors, as excitation for the blade, and as part of open- and closed-loop vibration control. Results show that with a single actuator patch, active vibration control causes the damping ratio to increase from a baseline of 0.3% critical damping to about 1.0% damping at 0 RPM. As the rotor speed approaches 5000 RPM, the actively controlled blade damping ratio decreases to about 0.5% damping. This occurs primarily because of centrifugal blade stiffening, and can be observed by the decrease in the generalized electromechanical coupling with rotor speed.

Duffy, Kirsten P.↗

Feasibility Assessment of an EVA Glove Sensing Platform to Evaluate Potential Hand Injury Risk Factors

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals that 58% of total astronaut hand and arm injuries from NBL training between 1993 and 2010 occurred either to the fingernail, MCP, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure force acting on the fingers and hand within pressurized gloves and other variables such as blood perfusion, skin temperature, humidity, fingernail strain, skin moisture, among others. Tasks were performed gloved and ungloved in a pressurizable glove box. The test demonstrated that fingernails saw greater transverse strain levels for tension or compression than for longitudinal strain, even during axial fingertip loading. Blood perfusion peaked and dropped as the finger deformed during finger presses, indicating an initial dispersion and decrease of blood perfusion levels. Force sensitive resistors to force plate comparisons showed similar force curve patterns as fingers were depressed, indicating suitable functionality for future testing. Strategies for proper placement and protection of these sensors for ideal data collection and longevity through the test session were developed and will be implemented going forward for future testing.

Reid, Christopher R.↗

Analysis of Potential Glove-Induced Hand Injury Metrics During Typical Neutral Buoyancy Training Operations

Injuries to the hands are common among astronauts who train for extravehicular activity. When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of NASA's Lifetime Surveillance of Astronaut Health's injury database reveals that 76 percent of astronaut hand and arm injuries from training between 1993 and 2010 occurred either to the fingernail, finger crotch, metacarpophalangeal joint, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure forces acting on the fingers and hand within pressurized gloves and other variables such as skin temperature, humidity, and fingernail strain of a NASA crewmember during typical NBL (Neutral Buoyancy Laboratory) training activity. During the 5-hour exercise, the crewmember seemed to exhibit very large forces on some fingers, resulting in higher strain than seen in previous glove-box testing. In addition, vital information was collected on the glove cavity environment with respect to temperature and humidity. All of this information gathered during testing will be carried forward into future testing, potentially in glove-box- or 1G- (1 gravitational force) or NBL-suited environments, to better characterize and understand the possible causes of hand injury amongst NASA crew.

McFarland, Shane↗

Characterizing Spatio-Temporal Ozone Gradients Along Coastal Boundaries: Sondes and Mobile Measurements from OWLETS-2

One of the major difficulties for the modeling and satellite communities is the validation of O3 levels in sharp coastal transition regions within metropolitan areas. Land-water gradients of ozone as well as its precursors can be significant due to differences in emissions, land use, surface deposition, boundary layer height, and mesoscale wind patterns. The Ozone Water-Land Environmental Transition Study (OWLETS-2) was a follow-on field campaign spearheaded by NASA GSFC and LaRC's Tropospheric Ozone Lidar Network (TOLnet) conducted in the summer of 2018 within the Upper Chesapeake region to better characterize spatial and vertical distribution of various pollutants across the coastal boundary. Supporting this campaign, 40 ozonesondes were simultaneously launched directly in the marine environment on Hart Miller Island (HMI) and on two land sites: both the University of Maryland, Baltimore County (UMBC) and Howard University-Beltsville (HUBV). In addition, Personal Ozone Monitors (POMs) - small sensors - were deployed in a variety of environments - car, boat, and drone, to name a few - to quantify ozone across fine spatial and temporal thresholds. The purpose of these measurements is multifaceted: to provide both ozone pollution information to coastal metropolitan communities and validation to satellite, modeling, and forecasting communities, especially in current and future satellite endeavors such as TROPOMI and TEMPO.

coastal pollution↗

TPSAS-NF1676L-30290-DND

The Summer 2017 Ozone Water Land Environmental Transition Study (OWLETS) mission set out to compare the differences in ozone concentrations between inland measurements of air quality, specifically at Langley Research Center (LaRC), and measurements taken over water, specifically on the Chesapeake Bay Bridge Tunnel (CBBT), as well as the vertical profiles above each location. Current weather models often predict a gradient in ozone concentration between land and ocean and this campaign attempted to capture this difference using hand-held Personal Ozone Monitors (POMs) in correspondence to ozonesondes and LIDAR measurements. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) is the first geostationary satellite that will take hourly measurements to monitor air pollutants across North America using solar backscatter. The small footprint allows for higher spatial resolution readings of many parameters including O3, NO2 , and aerosol. TEMPO’s higher resolution readings would benefit from validation techniques on the ground. Validation methods usually include comparison to air quality monitoring stations, but they could also incorporate other forms of validation such as comparison to small sensors. In cooperation with TEMPO, OWLETS aims to provide the user community high resolution temporal and spatial, both horizontal and vertical, variability of O3 simultaneously over the land and water during various air quality events to improve forecast models and air quality satellite retrievals. Together, these missions will improve spatial resolution and capture temporal variability of air quality over North America.

Emily Gargulinski↗

TPSAS-NF1676L-28489-DND

This presentation describes the integration of small sensor systems with sUAS vehicles that will better quantify emissions from hard-to-sample area sources, introduces current capabilities, highlights recent OWLETS missions, and discusses future campaigns.

Edward E Adcock↗

Multi-Source Sensor Fusion for Small Unmanned Aircraft Systems Using Fuzzy Logic

As the applications for using small Unmanned Aircraft Systems (sUAS) beyond visual line of sight (BVLOS) continue to grow in the coming years, it is imperative that intelligent sensor fusion techniques be explored. In BVLOS scenarios the vehicle position must accurately be tracked over time to ensure no two vehicles collide with one another, no vehicle crashes into surrounding structures, and to identify off-nominal scenarios. Therefore, in this study an intelligent systems approach is used to estimate the position of sUAS given a variety of sensor platforms, including, GPS, radar, and on-board detection hardware. Common research challenges include, asynchronous sensor rates and sensor reliability. In an effort to realize these challenges, techniques such as a Maximum a Posteriori estimation and a Fuzzy Logic based sensor confidence determination are used.

fuzzy logic↗