Search NASA⌕ Search

SEARCH · Search NASA

Results for “sodium heat pipe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrically Heated Testing of the Kilowatt Reactor Using Stirling Technology (KRUSTY) Experiment Using a Depleted Uranium Core

The Kilopower project aims to develop and demonstrate scalable fission-based power technology for systems capable of delivering 110 kW of electric power with a specific power ranging from 2.5 - 6.5 Wkg. This technology could enable high power science missions or could be used to provide surface power for manned missions to the Moon or Mars. NASA has partnered with the Department of Energys National Nuclear Security Administration, Los Alamos National Labs, and Y-12 National Security Complex to develop and test a prototypic reactor and power system using existing facilities and infrastructure. This technology demonstration, referred to as the Kilowatt Reactor Using Stirling TechnologY (KRUSTY), will undergo nuclear ground testing in the summer of 2017 at the Nevada Test Site. The 1 kWe variation of the Kilopower system was chosen for the KRUSTY demonstration. The concept for the 1 kWe flight system consist of a 4 kWt highly enriched Uranium-Molybdenum reactor operating at 800 degrees Celsius coupled to sodium heat pipes. The heat pipes deliver heat to the hot ends of eight 125 W Stirling convertors producing a net electrical output of 1 kW. Waste heat is rejected using titanium-water heat pipes coupled to carbon composite radiator panels. The KRUSTY test, based on this design, uses a prototypic highly enriched uranium-molybdenum core coupled to prototypic sodium heat pipes. The heat pipes transfer heat to two Advanced Stirling Convertors (ASC-E2s) and six thermal simulators, which simulate the thermal draw of full scale power conversion units. Thermal simulators and Stirling engines are gas cooled. The most recent project milestone was the completion of non-nuclear system level testing using an electrically heated depleted uranium (non-fissioning) reactor core simulator. System level testing at the Glenn Research Center (GRC) has validated performance predictions and has demonstrated system level operation and control in a test configuration that replicates the one to be used at the Device Assembly Facility (DAF) at the Nevada National Security Site. Fabrication, assembly, and testing of the depleted uranium core has allowed for higher fidelity system level testing at GRC, and has validated the fabrication methods to be used on the highly enriched uranium core that will supply heat for the DAF KRUSTY demonstration.

Briggs, Maxwell H.↗

Electrically Heated Testing of the Kilowatt Reactor Using Stirling TechnologY (KRUSTY) Experiment Using a Depleted Uranium Core

The Kilopower project aims to develop and demonstrate scalable fission-based power technology for systems capable of delivering 1 to 10 kW of electric power with a specific power ranging from 2.5 to 6.5 W/kg. This technology could enable high-power science missions or could be used to provide surface power for manned missions to the Moon or Mars. NASA has partnered with the U.S. Department of Energy's National Nuclear Security Administration, Los Alamos National Laboratory, Nevada National Security Site (NNSS), and Y−12 National Security Complex to develop and test a prototypic reactor and power system using existing facilities and infrastructure. This technology demonstration, referred to as the "Kilowatt Reactor Using Stirling TechnologY (KRUSTY)," will undergo nuclear ground testing by the end of calendar year (CY) 2017 at the NNSS. The 1-kWe variation of the Kilopower system was chosen for the KRUSTY demonstration. The concept for the 1-kWe flight system consists of a 4 kWt highly enriched uranium-molybdenum reactor operating at 800 degC coupled to sodium heat pipes. The heat pipes deliver heat to the hot ends of eight 125-W Stirling convertors producing a net electrical output of 1 kW. Waste heat is rejected using titanium-water heat pipes coupled to carbon composite radiator panels. The KRUSTY test, based on this design, uses a prototypic highly enriched uranium-molybdenum core coupled to prototypic sodium heat pipes. The heat pipes transfer heat to two Advanced Stirling Convertors (ASC−E2s) and six thermal simulators, which simulate the thermal draw of full-scale power conversion units. Thermal simulators and Stirling engines are gas cooled. The most recent project milestone was the completion of nonnuclear system-level testing using an electrically heated depleted uranium (DU) (nonfissioning) reactor core simulator at the NASA Glenn Research Center. System-level testing has validated performance predictions and has demonstrated system-level operation and control in a test configuration that replicates the one to be used at the Device Assembly Facility (DAF) at the NNSS. Fabrication, assembly, and testing of the DU core has allowed for higher fidelity system-level testing at Glenn, and has validated the fabrication methods to be used on the highly enriched uranium core that will supply heat for the DAF KRUSTY demonstration.

Briggs, Maxwell H.↗

The design and fabrication of a Stirling engine heat exchanger module with an integral heat pipe

The conceptual design of a free-piston Stirling Space Engine (SSE) intended for space power applications has been generated. The engine was designed to produce 25 kW of electric power with heat supplied by a nuclear reactor. A novel heat exchanger module was designed to reduce the number of critical joints in the heat exchanger assembly while also incorporating a heat pipe as the link between the engine and the heat source. Two inexpensive verification tests are proposed. The SSE heat exchanger module is described and the operating conditions for the module are outlined. The design process of the heat exchanger modules, including the sodium heat pipe, is briefly described. Similarities between the proposed SSE heat exchanger modules and the LeRC test modules for two test engines are presented. The benefits and weaknesses of using a sodium heat pipe to transport heat to a Stirling engine are discussed. Similarly, the problems encountered when using a true heat pipe, as opposed to a more simple reflux boiler, are described. The instruments incorporated into the modules and the test program are also outlined.

Schreiber, Jeffrey G.↗

The design and fabrication of a Stirling engine heat exchanger module with an integral heat pipe

The conceptual design of a free-piston Stirling Space Engine (SSE) intended for space power applications has been generated. The engine was designed to produce 25 kW of electric power with heat supplied by a nuclear reactor. A novel heat exchanger module was designed to reduce the number of critical joints in the heat exchanger assembly while also incorporating a heat pipe as the link between the engine and the heat source. Two inexpensive verification tests are proposed. The SSE heat exchanger module is described and the operating conditions for the module are outlined. The design process of the heat exchanger modules, including the sodium heat pipe, is briefly described. Similarities between the proposed SSE heat exchanger modules and the LeRC test modules for two test engines are presented. The benefits and weaknesses of using a sodium heat pipe to transport heat to a Stirling engine are discussed. Similarly, the problems encountered when using a true heat pipe, as opposed to a more simple reflux boiler, are described. The instruments incorporated into the modules and the test program are also outlined.

Schreiber, Jeffrey G.↗

Stirling engine external heat system design with heat pipe heater

This final report presents the conceptual design of a liquid fueled external heating system (EHS) and the preliminary design of a heat pipe heater for the STM-4120 Stirling cycle engine, to meet the Air Force mobile electric power (MEP) requirement for units in the range of 20 to 60 kW. The EHS design had the following constraints: (1) Packaging requirements limited the overall system dimensions to about 330 mm x 250 mm x 100 mm; (2) Heat flux to the sodium heat pipe evaporator was limited to an average of 100 kW/m and a maximum of 550 kW/m based on previous experience; and (3) The heat pipe operating temperature was specified to be 800 C based on heat input requirements of the STM4-120. An analysis code was developed to optimize the EHS performance parameters and an analytical development of the sodium heat pipe heater was performed; both are presented and discussed. In addition, construction techniques were evaluated and scale model heat pipe testing performed.

Godett, Ted M.↗

Sockeye Code Validation Against UNIST Heat Pipe - Poster - Internship 2025

Sockeye is an engineering level code being developed under the MOOSE framework for modeling heat pipes. A heat pipe is a sealed tube with a wick structure filled with a working fluid that transfers heat efficiently and passively via phase change of the working fluid. Heat applied to the evaporator end creates a pressure gradient which causes vapor to migrate to the condenser end where the vapor deposits its energy and condenses. Capillary force generated by the wick structure then draws the liquid back to the evaporator. A validation study was performed to compare the Sockeye code against data produced at the Ulsan National Institute of Standards and Technology for a slightly overfilled sodium heat pipe. The heat pipe was operated under natural convection cooling and a decreasing inactive length was observed. The experiment was modeled in Sockeye using the condenser pool model, the front non-condensable gas (NCG) model, and the mixture NCG model separately to reproduce the inactive length phenomenon. Also, a new capability was implemented in MOOSE to allow for conjugate heat transfer from the condenser based on the Churchill-Chu correlation for natural convection. The condenser pool model showed an increasing inactive length, demonstrating that the behavior was likely not caused by a pool of excess liquid. The front NCG model was able to show good agreement with the experiment, but it suffered convergence issues at the front. Finally, the mixture NCG model gave good results when the axial mesh was sufficiently refined. This work culminated in additions to the Sockeye documentation and a contribution to a journal article that will be published later. This poster is a summary of my work which I can take back to my university for presentation.

42 - ENGINEERING↗

A Conceptual Design Study on the Application of Liquid Metal Heat Transfer Technology to the Solar Thermal Power Plant

Alkali metal heat transfer technology was used in the development of conceptual designs for the transport and storage of sensible and latent heat thermal energy in distributed concentrator, solar Stirling power conversion systems at a power level of 15 kWe per unit. Both liquid metal pumped loop and heat pipe thermal transport were considered; system configurations included: (1) an integrated, focal mounted sodium heat pipe solar receiver (HPSR) with latent heat thermal energy storage; (2) a liquid sodium pumped loop with the latent heat storage, Stirling engine-generator, pump and valves located on the back side of the concentrator; and (3) similar pumped loops serving several concentrators with more centralized power conversion and storage. The focus mounted HPSR was most efficient, lightest and lowest in estimated cost. Design confirmation testing indicated satisfactory performance at all angles of inclination of the primary heat pipes to be used in the solar receiver.

Zimmerman, W. F.↗

Sodium Based Heat Pipe Modules for Space Reactor Concepts: Stainless Steel SAFE-100 Core

A heat pipe cooled reactor is one of several candidate reactor cores being considered for advanced space power and propulsion systems to support future space exploration applications. Long life heat pipe modules, with designs verified through a combination of theoretical analysis and experimental lifetime evaluations, would be necessary to establish the viability of any of these candidates, including the heat pipe reactor option. A hardware-based program was initiated to establish the infrastructure necessary to build heat pipe modules. This effort, initiated by Los Alamos National Laboratory and referred to as the Safe Affordable Fission Engine (SAFE) project, set out to fabricate and perform non-nuclear testing on a modular heat pipe reactor prototype that can provide 100 kilowatt from the core to an energy conversion system at 700 C. Prototypic heat pipe hardware was designed, fabricated, filled, closed-out and acceptance tested.

Martin, James J.↗

Thermostructural applications of heat pipes

The feasibility of integrating heat pipes in high temperature structure to reduce local hot spot temperature was evaluated for a variety of hypersonic aerospace vehicles. From an initial list of twenty-two potential applications, the single stage to orbit wing leading edge showed the greatest promise and was selected for preliminary design of an integrated heat pipe thermostructural system. The design consisted of a Hastelloy X assembly with sodium heat pipe passages aligned normal to the wing leading edge. A d-shaped heat pipe cross section was determined to be optimum from the standpoint of structural weight.

Peeples, M. E.↗

Modeling heat pipe startup and noncondensable gases in Sockeye

For this work, a one-dimensional gas mixture flow model was developed and implemented in the heat pipe code Sockeye to model the effects of noncondensable gases. Additionally, a startup model based on the dusty gas model was implemented to model the transition from rarefied gas dynamics to continuum flow, which occurs during the frozen startup of high-temperature heat pipes. Multiple startup and noncondensable gas models were tested against experimental data for sodium heat pipes, showing excellent agreement. Additionally, the newly developed gas mixture model for modeling noncondensable gas is further tested with a theoretical case study with arbitrary heating configurations. Finally, several recommendations and conclusions are made from the studies in this work to guide future heat pipe modeling efforts.

97 - MATHEMATICS AND COMPUTING↗

Stirling Space Engine Program: Final Report - Volume 1

The objective of this program was to develop the technology necessary for operating Stirling power converters in a space environment and to demonstrate this technology in full-scale engine tests. Hardware development focused on the Component Test Power Converter (CTPC), a single cylinder, 12.5-kWe engine. Design parameters for the CTPC were 150 bar operating pressure, 70 Hz frequency, and hot-and cold-end temperatures of 1050 K and 525 K, respectively. The CTPC was also designed for integration with an annular sodium heat pipe at the hot end, which incorporated a unique "Starfish" heater head that eliminated highly stressed brazed or weld joints exposed to liquid metal and used a shaped-tubed electrochemical milling process to achieve precise positional tolerances. Selection of materials that could withstand high operating temperatures with long life were another focus. Significant progress was made in the heater head (Udimet 700 and Inconel 718 and a sodium-filled heat pipe); the alternator (polyimide-coated wire with polyimide adhesive between turns and a polyimide-impregnated fiberglass overwrap and samarium cobalt magnets); and the hydrostatic gas bearings (carbon graphite and aluminum oxide for wear couple surfaces). Tests on the CTPC were performed in three phases: cold end testing (525 K), engine testing with slot radiant heaters, and integrated heat pipe engine system testing. Each test phase was successful, with the integrated engine system demonstrating a power level of 12.5 kWe and an overall efficiency of 22 percent in its maiden test. A 1500-hour endurance test was then successfully completed. These results indicate the significant achievements made by this program that demonstrate the viability of Stirling engine technology for space applications.

Dhar, Manmohan↗

Design optimization of gap distance for the capillary limitation of a heat pipe with annular-type wick structure

In this study, an experimental investigation was conducted on the rising height and contact angle of fluid in an annular wick-type heat pipe. The annular wick-type heat pipe was characterized by a small gap between the wick structure and tube wall, which compensated for the pressure drop along the porous media and created additional capillary force. To describe and model the advantage of this gap, the rising of a wetting liquid in the gap between a vertical solid plate and a mesh (with a small angle between them) was experimentally measured and analyzed. An additional experiment was performed to investigate the effect of curvature on the capillary rise using tubes and meshes of varying radii. Resultantly, we confirmed that the linear combination of the contact angles of the solid plate and mesh could be applied to calculate the rising height from the Laplace–Young equation. Furthermore, the effect of curvature on the rising height of the liquid was negligible. These results were extended to the investigation of finding the optimal gap distance for the annular wick-type heat pipe by referring to previous studies. We observed that a gap distance of 1.27 mm provided the largest permeability (K) over the effective pore radius (r eff ) value for a heat pipe with ethanol, which in turn resulted in the highest capillary limitation. For a sodium heat pipe, a gap distance of 0.84 mm resulted in the highest capillary limitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristic features of the operation of high-temperature heat pipes with a noncondesable gas

The principal concepts related to the nature of the processes occurring in high-temperature heat pipes with a noncondensable gas are examined, and guidelines for the development of such heat pipes are presented. The discussion is illustrated by experimental results obtained for a horizontal sodium heat pipe (diameter, 18/1 mm; length, 710 mm). In particular, attention is given to the starting dynamics and mechanisms, the shape of the vapor-gas front, and the vapor-gas front velocity.

Tolubinskiy, V. I.↗

Modeling Heat Pipe Startup And Noncondensable Gases In Sockeye

A one-dimensional gas mixture flow model was developed and implemented in the heat pipe code Sockeye to model the effects of non-condensable gases. Additionally a startup model based on the dusty gas model was implemented to model the transition from rarefied gas dynamics to continuum flow, which occurs during the frozen startup of high-temperature heat pipes. Multiple startup models and non-condensable gas models were tested against experimental data for sodium heat pipes, showing excellent agreement. Additionally, the newly developed gas mixture model for modeling non-condensable gas is further tested with a theoretical case study with arbitrary heating configurations. Finally, several recommendations and conclusions are made from the studies in this work to guide future heat pipe modeling efforts.

97 - MATHEMATICS AND COMPUTING↗

Model Validation and Uncertainty Quantification on the KRUSTY Microreactor Design Using GRIFFIN Neutron Transport Code [Poster]

Argonne National Laboratory (ANL) and INL have developed a GRIFFIN steady state neutronics model for the multiphysics simulations of the Kilopower Reactor Using Sterling TechnologY (KRUSTY) microreactor in the Multiphysics Object Oriented Simulation Environment (MOOSE). The reliability of such deterministic neutronics models can be validated by comparing with computations from Monte Carlo codes (e.g. MCNP, SERPENT, OpenMC, Shift, etc). Furthermore, potential modeling/design improvements can be identified by incorporating uncertainty quantification (UQ), which can be performed by MOOSE’s Stochastic Tools Module (STM). KRUSTY is a prototype for a 5-kW thermal nuclear-powered space reactor. Its primary components consist of nuclear fuel, heat pipes, a control rod, a reflector, and the shielding. The fuel consists of 3 stacked U-7.65Mo cylinders with a hole in the center for the control rod. 8 liquid sodium heat pipes transfer fission energy from the solid fuel block to the Sterling power conversion system where the energy is extracted, and the cooled sodium flows back to the core via capillary action . The movable Boron Carbide control rod regulates the neutron population during startup or when a reactor temperature boost is needed . The beryllium oxide reflector is in 3 places in the reactor; it surrounds the core axially, it lies beneath the core on a platen, and it is present in the shim. The axial and lower reflectors rest on an adjustable stainless-steel platen that moves upward to cover the fuel and help the reactor reach criticality. Lastly, radial stainless steel surrounds the core offering protection from radiation exposure .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Closeout Report for the Refractory Metal Accelerated Heat Pipe Life Test Activity

With the selection of a gas-cooled reactor, this heat pipe accelerated life test activity was closed out and its resources redirected. The scope of this project was to establish the long-term aging effects on Mo-44.5%Re sodium heat pipes when subjected to space reactor temperature and mass fluences. To date, investigators have demonstrated heat pipe life tests of alkali metal systems up to .50,000 hours. Unfortunately, resources have not been available to examine the effect of temperature, mass fluence, or impurity level on corrosion or to conduct post-test forensic examination of heat pipes. The key objective of this effort was to establish a cost/time effective method to systematically test alkali metal heat pipes with both practical and theoretical benefits. During execution of the project, a heat pipe design was established, a majority of the laboratory test equipment systems specified, and operating and test procedures developed. Procurements for the heat pipe units and all major test components were underway at the time the stop work order was issued. An extremely important outcome was the successful fabrication of an annular wick from Mo-5%Re screen (the single, most difficult component to manufacture) using a hot isostatic pressing technique. This Technical Publication (TP) includes specifics regarding the heat pipe calorimeter water-cooling system, vendor design for the radio frequency heating system, possible alternative calorimeter designs, and progress on the vanadium equilibration technique. The methods provided in this TP and preceding project documentation would serve as a good starting point to rapidly implement an accelerated life test. Relevant test data can become available within months, not years, and destructive examination of the first life test heat pipe might begin within 6 months of test initiation. Final conclusions could be drawn in less than a quarter of the mission duration for a long-lived, fission-powered, deep space probe.

Martin, J.↗

Vacuum Operation of Consolidated Heat Pipe (CHP) for Fission Surface Power

Consolidated Heat Pipe (CHP) is a new technology that enables direct thermal power delivery to the hot-end of a Stirling engine using a heat pipe--a two phase passive heat transfer device. CHP was developed after the efforts of the Kilopower Using Stirling TechnologY (KRUSTY) test where a heat pipe was used to deliver thermal power from a fission-basedreactor to a Stirling engine to produce 1 kWe of useable electrical power in 2018. Large thermal losses were noted during the KRUSTY test where a temperature drop of 145 °C was measured between the heat pipe’s condenser and the engine’s hot-end. The Consolidated Heat Pipe was designed to address and mitigate this temperature loss. CHP was designed, built and tested at the Glenn Research Center (GRC). The initial test was performed in ambient air conditions, and the results were presented in “Consolidation of a Sodium Heat Pipe and Stirling Engine for Fission Surface Power” at the Thermal Fluids Analysis Workshop in 2023. Researchers at GRC have tested this technology again in a vacuum environment in 2024. Results show that the heat pipe and the hot-end of the Stirling engine are isothermal with a minimal temperature differential of approximately 2.5 °C in varying operational states. The Consolidated Heat Pipe technology has proven to be an efficient way of delivering thermal power directly to Stirling engines.

Greeta J Thaikattil↗

Liquid fueled external heating system for STM4-120 Stirling engine

The STM4-120 Stirling engine, currently under development at Stirling Thermal Motors, Inc., is a 40 kW variable stroke engine with indirect heating using a sodium heat pipe. The engine is functionally separated into an application independent Energy Conversion Unit (ECU) consisting of the Stirling cycle and drive heated by condensing sodium and the application dependent External Heating System (EHS), designed to supply the ECU with sodium vapor heated by the particular energy source, connected by tubes with mechanical couplings. This paper describes an External Heating System for the STM4-120 ECU designed for the combustion of liquid fuel, comprised of a recuperative preheater, a combustion chamber, and a heat exchanger/evaporator where heat is transferred from the flue gas to the sodium causing it to evaporate. The design concept and projected performance are described and discussed.

Meijer, R. J.↗