Modernizing Accelerator Responsiveness and Controls in Operations

Accelerators increasingly use artificial intelligence (AI) and machine learning (ML) software and workflows for a variety of tasks, from optimization to fault detection and recovery. Efficient and sustainable application of these technologies necessitates specialized and facility-specific infrastructure commitments. Accelerator facilities also introduce unique radiation and security hazards, placing additional demands on operational infrastructure. These needs further escalate the prioritization of effective collaboration models and associated funding mechanisms and legal frameworks.

43 PARTICLE ACCELERATORS

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling

SWARM: Reimagining scientific workflow management systems in a distributed world

Modern scientific workflows process massive amounts of data from diverse instruments and sensors, leveraging geographically distributed, heterogeneous compute and storage resources—from leadership-class systems to edge devices—connected by high-performance networks. The diversity of resources introduces challenges in harnessing their full potential, with resilience issues arising across applications, system software, networks, storage, and hardware. Today, workflow management systems (WMS) coordinate the execution of computation and data management tasks across target resources. However, WMS’s centralized nature makes them vulnerable to faults and scalability issues that may result in failures of entire computational campaigns. In conclusion, this paper introduces a novel agentic framework for workflow management, fully distributing and decentralizing the WMS functions and modeling them as swarm intelligence agents infused with advanced artificial intelligence solutions and traditional distributed computing algorithms that can make coordinated decisions in the presence of failures of the underlying cyberinfrastructure.

Swarm intelligence

nrelWattileExt (SkySpark Wattile Extension) [SWR-24-73]

The NREL Wattile extension, nrelWattileExt, provides an interface between SkySpark, an energy management and analytics software, and Wattile, an NREL-developed Python package for probabilistic prediction of building energy consumption. Wattile models predict discrete quantiles of the probability distribution of a target quantity (typically energy consumption) using the historical time series data from one or more predictors (typically weather data). Within SkySpark, predictions from Wattile models can be used for measurement & verification of building performance, detection of energy anomalies, and fault detection. Related to: https://github.com/NREL/Wattile

Frank, Stephen

Visualizing a Vulnerability: Its Connections to Hardware and Software

All Hazards Analysis (AHA) is a framework developed by Idaho National Laboratory that provides capabilities to collect, store, analyze, and visualize critical infrastructure information. A core function of AHA is its ability to simulate faults or outages in networks of infrastructure originating from a plethora of causes, ranging from natural disasters to cyberattacks. AHA utilizes Hardware and Software Bills of Material (HBOM and SBOM, respectively) along with Known Exploited Vulnerabilities (KEVs) to document the potential attack vectors for each piece of infrastructure. The objective of this contribution to AHA was to create a visualization tool that could capture the small details held in each individual artifact as well as preserve the large-scale connections that link them together to aid threat modeling.

58 GEOSCIENCES

Transient Stability Analysis of Direct Droop-Controlled Grid-Forming Inverter with Current Clipping as Current Limiting Control

This paper investigates the transient stability of the direct droop-controlled grid-forming (GFM) inverter which employs the current clipping-based approach for overcurrent limitation. An equivalent circuit model of the direct-droop GFM inverter with current clipping is developed for this purpose. It is shown that during overcurrent conditions, the GFM inverter with current clipping acts as a voltage source with a virtual resistance behind the inverter filters. To compute the parameters of this virtual resistance an analytical expression is given in the paper. Then utilizing the developed circuit, a criteria to exit current limiting during post-fault conditions is given. The developed analytical approaches are then validated through electromagnetic transient (EMT) simulation results in PSCAD software and finally concluding remarks are drawn.

Mohiuddin, Sheik Mohammad

The SAS4A/SASSYS-1 Version 5.8 Safety Analysis Code System

SAS4A/SASSYS-1 is a software simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced nuclear reactors. Detailed, mechanistic models of steady-state and transient thermal, hydraulic, kinetic, and mechanical phenomena are employed to describe the response of the reactor core, the reactor primary and secondary coolant loops, the reactor control and protection systems, and the balance-of-plant to accidents caused by changes in coolant flow, loss of heat rejection, or reactivity insertion. The consequences of single and double-fault accidents can be modeled, including fuel and coolant heating, fuel and cladding mechanical behavior, core reactivity feedbacks, coolant loop performance including natural circulation, and decay heat removal. Analyses are typically terminated upon demonstration of reactor and plant shutdown to permanently coolable conditions, or upon violation of design basis margins. The objective of the analysis is to quantify accident consequences as measured by the transient behavior of system performance parameters, such as fuel and cladding temperatures, reactivity, and cladding strain. Originally developed for analysis of sodium cooled reactors with oxide fuel clad by stainless steel, the models were subsequently extended and specialized to metallic fuel clad with advanced alloys and to several other coolant options, including lead, LBE, and water.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Testing convolutional neural network based deep learning systems: a statistical metamorphic approach

Machine learning technology spans many areas and today plays a significant role in addressing a wide range of problems in critical domains,i.e., healthcare, autonomous driving, finance, manufacturing, cybersecurity,etc. Metamorphic testing (MT) is considered a simple but very powerful approach in testing such computationally complex systems for which either an oracle is not available or is available but difficult to apply. Conventional metamorphic testing techniques have certain limitations in verifying deep learning-based models (i.e., convolutional neural networks (CNNs)) that have a stochastic nature (because of randomly initializing the network weights) in their training. In this article, we attempt to address this problem by using a statistical metamorphic testing (SMT) technique that does not require software testers to worry about fixing the random seeds (to get deterministic results) to verify the metamorphic relations (MRs). We propose seven MRs combined with different statistical methods to statistically verify whether the program under test adheres to the relation(s) specified in the MR(s). We further use mutation testing techniques to show the usefulness of the proposed approach in the healthcare space and test two CNN-based deep learning models (used for pneumonia detection among patients). The empirical results show that our proposed approach uncovers 85.71% of the implementation faults in the classifiers under test (CUT). Furthermore, we also propose an MRs minimization algorithm for the CUT, thus saving computational costs and organizational testing resources.

Computer Science

Efficient Routing of Quantum LDPC Codes on Programmable 2D Toric Architectures

Quantum low-density parity-check codes are promising candidates towards scalable fault-tolerant quantum computation. Among these, bivariate bicycle (BB) codes offer superior encoding rates and large code distance compared to surface codes. However, their requirement on long-range stabilizer measurements poses significant challenges for implementation on realistic hardware with limited connectivity, such as superconducting circuit platforms. In this work, we introduce a novel hardware-software co-design that leverages a programmable communication network architecture to address these limitations. Our approach utilizes a 2D toric network of oscillators as a flexible communication fabric linking qubits at each site. Such architecture significantly reduces the number of long-range couplers required from O ( n ) to O (√ n ). Dual-rail qubits, along with native gates including Swap-Wait-Swap gates and beamsplitter SWAPs, ensure that long-range two-qubit gates can be executed with high fidelity and low latency. To further enhance performance, our qubit layout and routing algorithm utilize symmetries of the codes and enable maximum parallelism for long-range two-qubit gates, maintaining a low syndrome extraction cycle duration and scalability over the code length. We perform circuit-level simulation with realistic noise modeling based on experimental hardware parameters, observing an logical error rate per logical qubit per cycle of 3.06% for [[18,4,4]] BB code, 2.6× less than the existing experimental result. These findings provide a practical roadmap and identify key technological advancements needed to achieve low-overhead fault-tolerant quantum computing at scale.

Liu, Kun [Yale Univ., New Haven, CT (United States

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]

An open-access simulated earthquake ground-motion database for an M7 Hayward Fault earthquake in the San Francisco Bay Region

Comprehensive understanding of earthquake ground motions, particularly in the near-fault region of large-magnitude events, is limited by gaps in strong-motion data. This challenge is prominent in areas with high seismic hazard but infrequent large earthquakes where data is sparse and difficult to interpret. These data limitations lead to uncertainties in the development of site-specific ground motions, which are crucial for engineering risk assessments. To address these challenges, physics-based regional-scale ground-motion simulations have been developed. With the emergence of exaflop-scale computing ecosystems, it is now possible to simulate regional earthquake processes at unprecedented fidelity and generate the large number of fault rupture realizations necessary to characterize both intra- and inter-event ground-motion variability. This article introduces a new database of simulated earthquake ground motions, created for applications in earthquake engineering, earthquake planning, and emergency response. The inaugural version of the database features simulated ground motions for a magnitude 7 Hayward Fault earthquake in the San Francisco Bay Region (SFBR), using the EarthQuake SIMulation (EQSIM) simulation framework and the Graves–Pitarka kinematic rupture model. The aim is to provide high-fidelity, spatially dense, three-component motions generated on the Department of Energy’s (DOE) newest generation of graphics processing unit (GPU)-accelerated supercomputers. These motions are being made openly available to the engineering, scientific, and disaster planning communities. In addition, this work develops protocols for the efficient dissemination of these large data sets and emphasizes community engagement to build confidence in their application. This article discusses the methodology behind the data, underlying software verification and validation, scalable data management, and a user interface for data access. The goal is to facilitate widespread use and elicit expert feedback to maximize the utility and exploitation of simulated motions. While the initial focus is on the San Francisco Region, simulations for additional regions will be added as the DOE program progresses.

Simulated ground-motion database

High-Performance Computing Based EMT Simulation: Power Grid with IBRs

Electromagnetic transient (EMT) simulation of power grids with high-fidelity models of inverter-based resources (IBRs) is time-consuming and difficult to scale. The necessity for high-fidelity models of IBRs that incorporate the dynamics of individual inverters within IBRs has been showcased in recent studies. These studies focused on events with partial power reduction in each IBR during a transmission line fault in the power grid. These types of events have been documented in multiple North American Electric Reliability Council (NERC) reports in the past decade. It is imperative then to find solutions to speed-up EMT simulations and scale the size of the region with IBRs studied in EMT simulations. In this paper, a combination of numerical simulation algorithms with high-performance computing techniques are employed in discretization and linear solvers employed in the proposed RE-INTEGRATE EMT simulation platform for power grid with IBRs. For ease of scalability, modular and object-oriented programming is used as these techniques are implemented. Additionally, automation software is developed to convert legacy software codes to the proposed RE-INTEGRATE EMT simulation platform. Thereafter, this platform is evaluated on multi-core central processing units (CPUs). Finally, scale-up tests are performed to showcase the scalability that is possible.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000

Digitizing Today’s Buildings in the Real World: Lessons from Field Demonstrations

Digital twins, created by generating a virtual replica of a building, enable safe evaluation of operational scenarios and applications like fault detection and diagnosis and advanced controls. However, a prerequisite is the creation of a machine-readable digital representation of a building, currently hindered by fragmented information scattered across mechanical drawings, point lists, and natural language sequences. As a result, digital twin development remains labor-intensive, error-prone, and difficult to validate. To address these challenges, two efforts from ASHRAE aim to support the digitalization of buildings. ASHRAE s223 establishes a semantic model of buildings, representing system components, configuration, and data sources. ASHRAE s231 defines a vendor-neutral programming language for expressing their control logic. As the industry evaluates implementing them in their products, understanding the challenges that vendors and implementers may face is crucial. In this paper, we present findings and lessons learned from field demonstrations in five buildings that implemented control applications using ASHRAE s223 and s231. The demonstrations highlight how semantic modeling and formalized control descriptions can significantly reduce software development time, manual point mapping, and hard-coding. Beyond time efficiency, they enable reliable automation by minimizing human interpretation and providing a means for consistency across projects. We describe the processes and best practices for model creation and model usage, from translating heterogeneous building documentation into semantic representations to implementing control logic in real-world systems. Finally, we discuss the challenges that persist, including integration with legacy software environments, gaps in interoperability, and the level of expertise still required to effectively leverage semantic models.

Prakash, Anand Krishnan

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter

Leveraging Qubit Loss Detection in Fault-Tolerant Quantum Algorithms

Qubit loss errors constitute a dominant source of noise in many quantum hardware systems, particularly in neutral-atom quantum computers. We develop a theoretical framework to effectively detect and correct loss errors in logical algorithms and leverage such loss information in decoding. Considering general quantum error correction codes and logical circuits, we introduce a delayed-erasure decoder for experimentally motivated error models which leverages information from delayed loss detection to accurately correct loss errors, even when the precise moment of the error is unknown. Using this decoder, we identify strategies for detecting and correcting loss errors based on the logical circuit structure. For deep circuits prior to logical measurement, we explore methods to integrate loss detection into syndrome extraction with minimal overhead, identifying optimal strategies depending on the qubit loss fraction in the noise and hardware capabilities. In contrast, we find that many key algorithmic subroutines involve frequent gate teleportation, shortening the circuit depth before logical measurement and naturally replacing qubits with no additional experimental overhead. We simulate this setting using a toy model algorithm for small-angle synthesis and find a significant performance improvement as the loss fraction increases. These results provide a path forward for advancing large-scale fault-tolerant quantum computation in systems with loss error detection.

atoms

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando

Logical error rates for the surface code under a mixed coherent and stochastic circuit-level noise model inspired by trapped ions

With fault-tolerant quantum computing (FTQC) on the horizon, it is critical to understand sources of logical errors in plausible hardware implementations of quantum error-correcting codes. Detailed error modeling of computational instructions on particular FTQC architectures will enable the better prediction of error propagation in FT-encoded quantum circuits while revealing where greater attention is needed in hardware design. In this work, we consider logical error rates for the surface code implemented on a hypothetical grid-based trapped-ion quantum charge-coupled device architecture. Specifically, we construct logical channels for the idling surface code and examine its diamond error under a mixed coherent and stochastic circuit-level noise model inspired by trapped ions. We include the coherent dephasing noise that is known to accumulate during physical qubit idling and transport in these systems, determining idling and transport durations using the time-resolved output of an open-source trapped-ion surface code compiler. To estimate expectation values of logical Pauli observables following hardware circuits containing non-Clifford sources of noise, we utilize a Monte Carlo technique to sample from an underlying quasiprobability distribution of Clifford circuits that we independently simulate in a phase-sensitive fashion. We verify error suppression up to code distance 𝑑 = 11 at coherent dephasing rates near and below those of current-generation trapped-ion quantum computers and find that logical error rates align with those of analogous fully stochastic simulations in this regime. Exploring higher dephasing rates at 𝑑 = 3−5, we find evidence for growing coherent rotations about all three logical Pauli axes, increased diagonal logical error process matrix elements relative to those of stochastic simulations, and a reduced dephasing rate threshold. Overall, our work paves a way toward realistic hardware emulation of small fault-tolerant quantum processes, e.g., members of an FTQC instruction set.

Quantum benchmarking