Search NASA⌕ Search

SEARCH · Search NASA

Results for “software skeleton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

30 records · Page 2

Skeletides: A Modular, Simplified Physical Model of Protein Secondary Structure

Three-dimensional (3D) models are essential for visualization and conceptual understanding of complex architectures such as protein structure. Although there is a plethora of software platforms that allow digital depictions of protein structure at an atomic level in silico, physical models are needed to convey an intuitive understanding of biomolecular architecture. However, it is a challenge to represent all the relevant features of proteins in a single physical model due to their sheer structural complexity. Here, we describe a modular protein model that focuses only on representation of the secondary structure—the underlying structural skeleton. The simplified model consists of amino acid units, which can be linked together to reproduce the two most fundamental structural features of protein secondary structure: the relative positions of the amino acid alpha carbon atoms, and the intra-main chain hydrogen bonding pattern. We use 3D printing and magnets to create a set of three modular amino acid building blocks, which when linked together into a chain, can faithfully represent alpha helices, beta sheets, and turns. These simple to make models can be used to quickly assemble the alpha carbon trace of an entire protein domain, which conveys a tactile experience of the complexity of protein skeletal architecture. These models highlight the modularity of protein structure: where a single structural unit, the amino acid, can be linked together to form a larger, regular secondary structure. These models also have a propensity to spontaneously organize into alpha helices and beta sheets, as demonstrated by their ability to autonomously assemble when placed in a circulating water tank. These models provide a missing educational tool to expand knowledge of protein structure, foster deeper insight into protein folding, and inspire greater interest in biomacromolecular architecture.

36 MATERIALS SCIENCE↗

Emulator Generation Gadget

This software automates the production of standalone emulators for complex computer models. The end result of running the software is a piece of code called an emulator, a statistical approximation which predicts the output of complex computer simulation, but at a much faster speed. The emulator is built using a training set of inputs and outputs from the simulations. The input-output pairs are used in a Bayesian scheme to estimate the parameters of a Gaussian process based regression model that learns the input-output relationship. The estimated parameters are combined with a generic C skeleton to produce a compile-able instantiation of the emulator.

Sweeney, Christine↗

VESGEN Software for Mapping and Quantification of Vascular Regulators

VESsel GENeration (VESGEN) Analysis is an automated software that maps and quantifies effects of vascular regulators on vascular morphology by analyzing important vessel parameters. Quantification parameters include vessel diameter, length, branch points, density, and fractal dimension. For vascular trees, measurements are reported as dependent functions of vessel branching generation. VESGEN maps and quantifies vascular morphological events according to fractal-based vascular branching generation. It also relies on careful imaging of branching and networked vascular form. It was developed as a plug-in for ImageJ (National Institutes of Health, USA). VESGEN uses image-processing concepts of 8-neighbor pixel connectivity, skeleton, and distance map to analyze 2D, black-and-white (binary) images of vascular trees, networks, and tree-network composites. VESGEN maps typically 5 to 12 (or more) generations of vascular branching, starting from a single parent vessel. These generations are tracked and measured for critical vascular parameters that include vessel diameter, length, density and number, and tortuosity per branching generation. The effects of vascular therapeutics and regulators on vascular morphology and branching tested in human clinical or laboratory animal experimental studies are quantified by comparing vascular parameters with control groups. VESGEN provides a user interface to both guide and allow control over the users vascular analysis process. An option is provided to select a morphological tissue type of vascular trees, network or tree-network composites, which determines the general collections of algorithms, intermediate images, and output images and measurements that will be produced.

Parsons-Wingerter, Patricia A.↗

Consistent Space Runtime (CSPACER) v1.0

This software provides a runtime for communication-bound applications, especially with irregular communication patterns. The target programming abstraction for the runtime is the space consistency model, which defines consistency guarantees at the granularity of memory spaces. This model has relaxed consistency semantics that enables a wide range of runtime optimizations. The runtime leverages threading to accelerate communication primitives, especially collective operations. It also allows efficient pipelining of communication operations and enable constructing a consistent state of multiple unordered communication activities targeting a memory space. The runtime uses a reduced API design that decomposes complex communication primitives in traditional general-purpose runtime into a sequence of simpler steps. To improve the productivity of using this runtime, we provide communication patterns commonly used for regular scientific computing applications and irregular data analytics. These communication patterns offer skeletons for the integration with application computation to allow efficient overlap.

Ibrahim, Khaled↗

SU-F-I-14: 3D Breast Digital Phantom for XACT Imaging

Purpose: The X-ray induced acoustic computed tomography (XACT) is a new imaging modality which combines X-ray contrast and high ultrasonic resolution in a single modality. Using XACT in breast imaging, a 3D breast volume can be imaged by only one pulsed X-ray radiation, which could dramatically reduce the imaging dose for patients undergoing breast cancer screening and diagnosis. A 3D digital phantom that contains both X-ray properties and acoustic properties of different tissue types is indeed needed for developing and optimizing the XACT system. The purpose of this study is to offer a realistic breast digital phantom as a valuable tool for improving breast XACT imaging techniques and potentially leading to better diagnostic outcomes. Methods: A series of breast CT images along the coronal plane from a patient who has breast calcifications are used as the source images. A HU value based segmentation algorithm is employed to identify breast tissues in five categories, namely the skin tissue, fat tissue, glandular tissue, chest bone and calcifications. For each pixel, the dose related parameters, such as material components and density, and acoustic related parameters, such as frequency-dependent acoustic attenuation coefficient and bandwidth, are assigned based on tissue types. Meanwhile, other parameters which are used in sound propagation, including the sound speed, thermal expansion coefficient, and heat capacity are also assigned to each tissue. Results: A series of 2D tissue type image is acquired first and the 3D digital breast phantom is obtained by using commercial 3D reconstruction software. When giving specific settings including dose depositions and ultrasound center frequency, the X-ray induced initial pressure rise can be calculated accordingly. Conclusion: The proposed 3D breast digital phantom represents a realistic breast anatomic structure and provides a valuable tool for developing and evaluating the system performance for XACT.

60 APPLIED LIFE SCIENCES↗

Flexible Pilot Jobs Framework for Distributed High Throughput Computing

Experimental particle physics has been at the forefront of analyzing the world’s largest datasets for decades. The high-energy physics (HEP) community was among the first to develop suitable software and computing tools for this purpose. GlideinWMS is a Glidein-based workload management system whose purpose is to provide experiments like CMS at CERN, DUNE at Fermilab, and others, a way to access and efficiently use vast amounts of computing resources. This system wants to provide a simple way to submit jobs to a set of computing resources, that will be provided to users behind the scenes. Glideins are the pilot jobs executed on the worker nodes at the grid sites, performing operations such as hardware detection, environment setup, and error handling. After all these operations, they will launch the actual user job. Many grid sites are supported, such as shared clusters, Google CE, and AWS. My internship aimed to design and code a flexible pilot jobs framework that will replace the one used by GlideinWMS, developing a modular and flexible skeleton of the Glidein and adding further functionalities. My project also focused on the application of machine learning techniques as support to this management system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Human-Computer Interface Concepts for Mission Operations

The current climate of budget cuts has forced the space mission operations community to reconsider how it does business. Gone are the days of building one-of-kind control centers with teams of controllers working in shifts 24 hours per day, 7 days per week. Increasingly, automation is used to significantly reduce staffing needs. In some cases, missions are moving towards lights-out operations where the ground system is run semi-autonomously. On-call operators are brought in only to resolve anomalies. Some operations concepts also call for smaller operations teams to manage an entire family of spacecraft. In the not too distant future, a skeleton crew of full-time general knowledge operators will oversee the operations of large constellations of small spacecraft, while geographically distributed specialists will be assigned to emergency response teams based on their expertise. As the operations paradigms change, so too must the tools to support the mission operations team's tasks. Tools need to be built not only to automate routine tasks, but also to communicate varying types of information to the part-time, generalist, or on-call operators and specialists more effectively. Thus, the proper design of a system's user-system interface (USI) becomes even more importance than before. Also, because the users will be accessing these systems from various locations (e.g., control center, home, on the road) via different devices with varying display capabilities (e.g., workstations, home PCs, PDAS, pagers) over connections with various bandwidths (e.g., dial-up 56k, wireless 9.6k), the same software must have different USIs to support the different types of users, their equipment, and their environments. In other words, the software must now adapt to the needs of the users! This paper will focus on the needs and the challenges of designing USIs for mission operations. After providing a general discussion of these challenges, the paper will focus on the current efforts of creatin(y an effective USI for one specific suite of tools, SERS (The Spacecraft Emergency Response System), which has been built to enable lights-out operations. SERS is a Web-based collaborative environment that enables secure distributed fault management.

Fox, Jeffrey A.↗

Generating MCNP Input Files for Unstructured Mesh Geometries

The Los Alamos National Laboratory’s (LANL) Monte Carlo N-Particle (MCNP)1 transport code version 6.3 (also known as MCNP6.3) has the capability for tracking particles on unstructured mesh (UM) geometry models embedded into constructive solid geometry (CSG) cells. This feature has been developed for performing calculations of complex geometry models because manually creating CSG models is time-consuming and error-prone as the complexities of geometries increase. A UM geometry model is a collection of finite elements representing a solid geometry. The first step of the MCNP UM calculation is using other software packages to create a finite element mesh representation of a solid 3D geometry because the MCNP code cannot be used to generate a UM model. Computer-aided design (CAD) software is typically used to create a solid geometry model, which is later imported into mesh generation software to create a UM model. Some mesh generation software packages may also be used to create solid geometries and thus CAD files are not needed. The MCNP UM feature was originally designed for models generated by the Abaqus/CAE software suite. The MCNP code version 6.0 and later can process UM models formatted as Abaqus input files. Starting with a 6.3 version, the MCNP code can process HDF5 mesh input files. We only focus on the UM models formatted as Abaqus input files in this report since currently no external software can be used to generate HDF5 mesh input files for MCNP UM calculations. The MCNP code version 6.3 can be used to convert the Abaqus mesh input files into the HDF5 mesh input files, but this option is typically used by the MCNP code development team to test the HDF5 mesh input file feature. Several software packages (such as Abaqus, Attila4MC, or Cubit) can be used to create the Abaqus input files for MCNP UM calculations. An MCNP UM calculation using an Abaqus model requires two input file types: MCNP and Abaqus input files. The Abaqus input files needed for MCNP UM calcu lations must have the correct Abaqus syntax and meet the additional requirements by the MCNP code. The MCNP code can process only Abaqus input files that make use of part and assembly definitions, where elements in each part must be grouped into one or more element sets (i.e., elset) using *Elset keyword lines with specified naming formats. The MCNP and Abaqus input files required for MCNP UM simulations must be related; pseudo-cells in an MCNP input file must be constructed from mesh model data from an Abaqus input file. For large complex UM models, it is tedious to manually create MCNP UM input files. The um pre op (unstructured mesh pre operations) program with the -m option can be used to create a skeleton MCNP input file from an Abaqus input file [6]. Since the um pre op program was written in Fortran and was not written for optimized performance, this program is a deprecated feature in the MCNP code version 6.3 and may be removed in the next release of the code. To improve calculation flow of multiphysics calculations, a Python3 code called write mcnp um input has been developed to generate an MCNP input file instead of using the um_pre_op -m option. This Python code was initially released to the public in 2020. We have updated this Python code for MCNP6.3 and it was used to generate the MCNP input files used to verify the MCNP6.3 code. The write_mcnp_um_input code is included with the MCNP6.3 code package which will be released to the public through the Radiation Safety Information Computational Center (RSICC) at Oak Ridge National Laboratory. This report is a revision of LA-UR-20-27139 report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ambient occlusion – A powerful algorithm to segment shell and skeletal intrapores in computed tomography data

During the last decades, X-ray (micro-)computed tomography has gained increasing attention for the description of porous skeletal and shell structures of various organism groups. However, their quantitative analysis is often hampered by the difficulty to discriminate cavities and pores within the object from the surrounding region.Herein, we test the ambient occlusion (AO) algorithm and newly implemented optimisations for the segmentation of cavities (implemented in the software Amira). The segmentation accuracy is evaluated as a function of (i) changes in the ray length input variable, and (ii) the usage of AO (scalar) field and other AO-derived (scalar) fields. The results clearly indicate that the AO field itself outperforms all other AO-derived fields in terms of segmentation accuracy and robustness against variations in the ray length input variable. The newly implemented optimisations improved the AO field-based segmentation only slightly, while the segmentations based on the AO-derived fields improved considerably.Additionally, we evaluated the potential of the AO field and AO-derived fields for the separation and classification of cavities as well as skeletal structures by comparing them with commonly used distance-map-based segmentations. For this, we tested the zooid separation within a bryozoan colony, the stereom classification of an ophiuroid tooth, the separation of bioerosion traces within a marble block and the calice (central cavity)-pore separation within a dendrophyllid coral. The obtained results clearly indicate that the ideal input field depends on the three-dimensional morphology of the object of interest The segmentations based on the AO-derived fields often provided cavity separations and skeleton classifications that at were superior to or impossible to obtain with commonly used distance-map-based segmentations. The combined usage of various AO-derived fields by supervisd or unsupervised segmentation algorithms might provide a promising target for future research to further improve the results for this kind of high-end data segmentation and classification. Furthermore, the application of the developed segmentation algorithm is not restricted to X-ray (micro-)computed tomographic data but may potentially be useful for the segmentation of 3D volume data from other sources.

Computed tomography, Micro-computed tomography, Po↗

SU-C-207B-05: Tissue Segmentation of Computed Tomography Images Using a Random Forest Algorithm: A Feasibility Study

Purpose: Develop an automated Random Forest algorithm for tissue segmentation of CT examinations. Methods: Seven materials were classified for segmentation: background, lung/internal gas, fat, muscle, solid organ parenchyma, blood/contrast, and bone using Matlab and the Trainable Weka Segmentation (TWS) plugin of FIJI. The following classifier feature filters of TWS were investigated: minimum, maximum, mean, and variance each evaluated over a pixel radius of 2n, (n = 0–4). Also noise reduction and edge preserving filters, Gaussian, bilateral, Kuwahara, and anisotropic diffusion, were evaluated. The algorithm used 200 trees with 2 features per node. A training data set was established using an anonymized patient’s (male, 20 yr, 72 kg) chest-abdomen-pelvis CT examination. To establish segmentation ground truth, the training data were manually segmented using Eclipse planning software, and an intra-observer reproducibility test was conducted. Six additional patient data sets were segmented based on classifier data generated from the training data. Accuracy of segmentation was determined by calculating the Dice similarity coefficient (DSC) between manual and auto segmented images. Results: The optimized autosegmentation algorithm resulted in 16 features calculated using maximum, mean, variance, and Gaussian blur filters with kernel radii of 1, 2, and 4 pixels, in addition to the original CT number, and Kuwahara filter (linear kernel of 19 pixels). Ground truth had a DSC of 0.94 (range: 0.90–0.99) for adult and 0.92 (range: 0.85–0.99) for pediatric data sets across all seven segmentation classes. The automated algorithm produced segmentation with an average DSC of 0.85 ± 0.04 (range: 0.81–1.00) for the adult patients, and 0.86 ± 0.03 (range: 0.80–0.99) for the pediatric patients. Conclusion: The TWS Random Forest auto-segmentation algorithm was optimized for CT environment, and able to segment seven material classes over a range of body habitus and CT protocol parameters with an average DSC of 0.86 ± 0.04 (range: 0.80–0.99).

60 APPLIED LIFE SCIENCES↗

SU-F-R-55: Early Detection of Treatment Induced Bone Marrow Injury During Chemoradiation Therapy Using Quantitative CT

Purpose: Acute hematologic toxicity associated with bone marrow injury is a common complication of chemoradiation therapy (CRT) for pelvic malignancies. In this work, we investigate the feasibility of using quantitative CT to detect bone marrow injury during CRT. Methods: Daily CTs were acquired during routine CT-guided radiation therapy using a CT-on-rails for 15 cervical cancer patients. All patients treated with a radiation dose of 45.0 to 50.4 Gy in 1.8 Gy/fraction along with chemotherapy. For each patient, the contours of bone marrow were generated in L4, L5 and sacrum on the first daily CT and then populated to other daily CTs by rigid registration using MIM (MIM Software Inc., Cleveland, OH) with manual editing if possible. A series of CT texture parameters, including Hunsfield Unit (HU) histogram, mean HU, entropy, energy, in bone marrow contours were calculated using MATLAB on each daily CT and were correlated with the completed blood counts (CBC) collected weekly for each patient. The correlations were analyzed with Pearson correlation tests. Results: For all patient data analyzed, mean HU in bone marrow decreased during CRT delivery. From the first to the last fraction the average mean HU reduction is 58.1 ± 13.6 HU (P<0.01). This decrease can be observed as early as after first 5 fractions and is strongly associated with the changes of most CBC quantities, such as the reductions of white and blood cell counts (r=0.97, P=0.001). The reduction of HU is spatially varied. Conclusion: Chemoradiation induced bone marrow injury can be detected during the delivery of CRT using quantitative CT. Chemoradiation results in reductions in mean HU, which are strongly associated with the change in the pretrial blood cell counts. Early detection of bone marrow injury with commonly available CT opens a door to improve bone marrow sparing, reducing risk of hematologic toxicity.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-06: Dosimetric and Workflow Evaluation of First Commercial Synthetic CT Software for Clinical Use in Pelvis

Purpose: evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy Methods: Twenty prostate patients underwent CT and MR simulation scans in treatment position on a 3T Philips scanner. The MR protocol consisted of a T2w turbo spin-echo for soft tissue contrast, a 2D balanced-fast field echo (b-FFE) for fiducial identification, a dual-echo 3D FFE B0 map for distortion analysis and a 3D mDIXON FFE sequence to generate syn-CT. Two echoes are acquired during mDIXON scan, allowing water, fat, and in-phase images to be derived using the frequency shift of the fat and water protons. Tissues were classified as: air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned specific bulk HU values. Bone structures are segmented based on a pelvis bone atlas. Accuracy of syn-CT for patient treatment planning was analyzed by transferring the original plan and structures from the CT to syn-CT via rigid registration and recalculating dose. In addition, new IMRT plans were generated on the syn-CT using structures contoured on MR and transferred to the syn-CT. Accuracy of fiducial-based localization at the treatment machine performed using syn-CT or DRRs generated from syn-CT was assessed by comparing to orthogonal kV radiographs or CBCT. Results: Dosimetric comparison between CT and syn-CT was within 0.5% for all structures. The de-novo optimized plans generated on the syn-CT met our institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B0 maps was within 1mm and 0.4 mm in the body and prostate. The rectal and bladder outlines on the syn-CT were deemed sufficient for assessing rectal and bladder filling on the CBCT at the time of treatment. CBCT localization showed a median error of < ±1 mm in LR, AP and SI direction. Conclusion: MRI derived syn-CT can be used clinically in MR-alone planning and treatment process for prostate. Drs. Deasy, Hunt and Tyagi have Master research agreement with Philips healthcare.

60 APPLIED LIFE SCIENCES↗