Search NASA⌕ Search

SEARCH · Search NASA

Results for “solar absorption cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Solar-powered air-conditioning

Report focuses on recent study on development of solar-powered residential air conditioners and is based on selected literature through 1975. Its purposes are to characterize thermal and mechanical systems that might be useful in development of Rankine-cycle approach to solar cooling and assessment of a Lithium Bromide/Water absorption cycle system.

Clark, D. C.↗

Active Upper-atmosphere Chemistry and Dynamics from Polar Circulation Reversal on Titan

Saturn's moon Titan has a nitrogen atmosphere comparable to Earth's, with a surface pressure of 1.4 bar. Numerical models reproduce the tropospheric conditions very well but have trouble explaining the observed middle-atmosphere temperatures, composition and winds. The top of the middle-atmosphere circulation has been thought to lie at an altitude of 450 to 500 kilometres, where there is a layer of haze that appears to be separated from the main haze deck. This 'detached' haze was previously explained as being due to the colocation of peak haze production and the limit of dynamical transport by the circulation's upper branch. Herewe report a build-up of trace gases over the south pole approximately two years after observing the 2009 post-equinox circulation reversal, from which we conclude that middle-atmosphere circulation must extend to an altitude of at least 600 kilometres. The primary drivers of this circulation are summer-hemisphere heating of haze by absorption of solar radiation and winter-hemisphere cooling due to infrared emission by haze and trace gases; our results therefore imply that these effects are important well into the thermosphere (altitudes higher than 500 kilometres). This requires both active upper-atmosphere chemistry, consistent with the detection of high-complexity molecules and ions at altitudes greater than 950 kilometres, and an alternative explanation for the detached haze, such as a transition in haze particle growth from monomers to fractal structures.

Titan Atmosphere↗

Electrospun Silica Nanofibers as Passive Thermal Control Materials for the Extreme Environment of Low Earth Orbit

Effective thermal management is crucial for maintaining spacecraft and onboard systems at optimal temperatures, ensuring their longevity in space missions. Passive thermal management is particularly promising due to its lower power consumption compared to active systems. This study focuses on developing materials with low solar absorptance and large thermal emittance to facilitate self-cooling under the harsh thermal conditions of space. We employ electrospinning, a nano/micro-manufacturing technique, to create a lightweight, fibrous thermal control material from silica (SiO 2 ). Using scanning electron microscopy (SEM), we examine the nanoporous structure of the electrospun material. Its optical properties, including reflectance, transmittance, and absorptance across ultraviolet, visible, and infrared wavelengths, are assessed using spectrometers interfaced with integrating spheres. To test durability in space, we conduct high temperature endurance and ultraviolet resistance tests to observe changes in optical properties of the materials and evaluate their performance in low Earth orbit (LEO). We also compare the material's solar reflectance and thermal emittance to existing spacecraft materials. The findings suggest that electrospun silica nanofibers presents a new paradigm for passive thermal control in space applications.

thermal emittance↗

Tropical Surface Temperature Response to Vegetation Cover Changes and the Role of Drylands

Vegetation cover creates competing effects on land surface temperature: it typically cools through enhancing energy dissipation and warms via decreasing surface albedo. Global vegetation has been previously found to overall net cool land surfaces with cooling contributions from temperate and tropical vegetation and warming contributions from boreal vegetation. Recent studies suggest dryland vegetation across the tropics strongly contributes to this global net cooling feedback. However, observation-based vegetation-temperature interaction studies have been limited in the tropics, especially in their widespread drylands. Theoretical considerations also call into question the ability of dryland vegetation to strongly cool the surface under low water availability. Here, we use satellite observations to investigate how tropical vegetation cover influences the surface energy balance. We find that while increased vegetation cover would impart net cooling feedbacks across the tropics, net vegetal cooling effects are subdued in drylands. Using observations, we determine that dryland plants have less ability to cool the surface due to their cooling pathways being reduced by aridity, overall less efficient dissipation of turbulent energy, and their tendency to strongly increase solar radiation absorption. As a result, while proportional greening across the tropics would create an overall biophysical cooling feedback, dryland tropical vegetation reduces the overall tropical surface cooling magnitude by at least 14%, instead of enhancing cooling as suggested by previous global studies.

Vegetation↗

Tropical Surface Temperature Response to Vegetation Cover Changes and the Role of Drylands

Vegetation cover creates competing effects on land surface temperature: it typically cools through enhancing energy dissipation and warms via decreasing surface albedo. Global vegetation has been previously found to overall net cool land surfaces with cooling contributions from temperate and tropical vegetation and warming contributions from boreal vegetation. Recent studies suggest dryland vegetation across the tropics strongly contributes to this global net cooling feedback. However, observation-based vegetation-temperature interaction studies have been limited in the tropics, especially in their widespread drylands. Theoretical considerations also call into question the ability of dryland vegetation to strongly cool the surface under low water availability. Here, we use satellite observations to investigate how tropical vegetation cover influences the surface energy balance. We find that while increased vegetation cover would impart net cooling feedbacks across the tropics, net vegetal cooling effects are subdued in drylands. Using observations, we determine that dryland plants have less ability to cool the surface due to their cooling pathways being reduced by aridity, overall less efficient dissipation of turbulent energy, and their tendency to strongly increase solar radiation absorption. As a result, while proportional greening across the tropics would create an overall biophysical cooling feedback, dryland tropical vegetation reduces the overall tropical surface cooling magnitude by at least 14%, instead of enhancing cooling as suggested by previous global studies.

Biophysical Feedbacks↗

A bioinspired approach for adaptive solid-solid phase change material coatings with optimized surface features for passive thermal regulation

The necessity to reduce global energy consumption calls for innovative strategies in building thermal management. Passive thermal regulation, particularly through bio-inspired designs, offers a promising avenue by mimicking nature's efficient control of optical properties. This research introduces a novel, climate-responsive coating that integrates optimized bio-inspired surface features with a solid-solid phase change material (SS-PCM) to dynamically manage solar absorptivity without adding additional thickness, enabling both heating and cooling as needed. Drawing on the photonic architectures of the Saharan silver ant and Morpho Didius butterfly, we employed a modeling and multi-objective optimization framework to tailor these surface features. Simulations reveal that surface texture, rather than the intrinsic phase transition of the SS PCM, dominates optical control. Relative to a flat SS PCM coating, optimized isotropic random roughness and broader range features yielded the highest passive heating power increase of about 144 % and 319 % respectively suitable for cold climates. Saharan ant-inspired features enhanced passive cooling for hot climates, achieving a 21.8 % improvement. For moderate climates, Butterfly-wing-inspired surface features provided a balanced enhancement of 19 % for heating and 7 % for cooling. Across all cases, the optimized surface features reduced combined heating and cooling energy demand more effectively than the baseline coating, while preserving material thickness. These findings demonstrate that climate-adaptive, optimized bio-inspired surface features can unlock the full potential of SS PCM coatings, providing a versatile pathway to significant energy savings in buildings and other applications. The methodology establishes a framework for designing next-generation adaptive envelopes that leverage natural photonic principles for high-impact, low-cost thermal regulation.

36 MATERIALS SCIENCE↗

The zonally averaged circulation of the middle atmosphere

The steady-state, zonally averaged circulation of the middle atmosphere (15-125 km) is studied with a quasigeostrophic, numerical model that explicitly includes a self-consistent calculation of solar radiative heating due to O2 and O3 absorption, Newtonian cooling, Rayleigh friction, tropopause boundary conditions based on climatological averages, and the effects of vertically propagating planetary waves. It is found that the direct, radiatively driven pole-to-pole circulation at solstice is sufficient to account for the cold summer mesopause and warm isothermal winter mesosphere with associated zonal jets of realistic magnitude. The climatological heat and momentum fluxes associated with planetary wavenumber 2 have a negligible effect on the mean circulation. With planetary wavenumber 1, no steady-state solution could be obtained due to the formation of easterlies and hence critical layers in the winter mesosphere. The radiative heating associated with secondary peaks in the O3 density at the mesopause could render the polar mesopause region convectively unstable.

Schoeberl, M. R.↗

Non-LTE models of Titan's upper atmosphere

Models for the thermal structure of Titan's upper atmosphere, between 0.1 mbar and 0.01 nbar are presented. The calculations include non-LTE heating/cooling in the rotation-vibration bands of CH4, C2H2, and C2H6, absorption of solar IR radiation in the near-IR bands of CH4 and subsequent cascading to the nu-4 band of CH4, absorption of solar EUV and UV radiation, thermal conduction and cooling by HCN rotational lines. Unlike earlier models, the calculated exospheric temperature agrees well with observations, because of the importance of HCN cooling. The calculations predict a well-developed mesopause with a temperature of 135-140 K at an altitude of approximately 600 km and pressure of about 0.1 microbar. The mesopause is at a higher pressure than predicted by earlier calculations because non-LTE radiative transfer in the rotation-vibration bands of CH4, C2H2, and C2H6 is treated in an accurate manner. The accuracy of the LTE approximation for source functions and heating rates is discussed.

Yelle, Roger V.↗

Passively Cooled Superconductors Final Report

A highly reflective spray-on coating and tile material has been under development at Kennedy Space Center (KSC) that scatters away most of the Sun’s energy, thereby allowing coated objects to remain cool in space. The best performing tile material has achieved 1% solar absorptivity while the best performing spray-on coating has achieved around 4%. Both versions passively maintain cryogenic temperatures below 120 K at 1 astronomical unit (AU) from the Sun, but the tile material consistently sustains temperatures below 90 K, which is low enough to preserve oxygen and methane in a liquid state. Besides keeping propellants cold, this “solar white” material has the potential to passively maintain high-temperature superconductors (HTS) in a superconducting state without the support of liquid nitrogen cooling. If superconductors can be operated without the added infrastructure of liquid nitrogen cooling, it may enable them to be used in space for applications like magnetic radiation shielding and efficient energy management. Long duration exposure to both galactic cosmic radiation and coronal mass ejections can pose health risks for the astronauts and increase the potential for damage to electronics. This makes shielding essential to accomplish long duration missions, particularly when astronauts are onboard. The objective of this project was to determine the extent we could keep a high-temperature superconducting (HTS) material passively chilled to maintain its superconducting state. Both the tile and spray-on versions of solar white were investigated. We focused on finding a version that could support passive cooling at 1 AU from the Sun and determined the closest operating distances for samples that were unable to perform at 1 AU. Early in the project, we selected bismuth strontium calcium copper oxide (BSCCO) as the HTS to test based on its reputable usage in superconducting wires. The version we selected was Bi-2223, which has a critical temperature of about 108 K. Sample bars with contacts for a four-point probe were obtained from Quantum Levitation: https://quantumlevitation.com/product/superconductor-bar-for-4-point-tc-experiment/.

superconductors↗

Highly ionized gas absorption in the disk and halo toward HD 167756 at 3.5 kilometers per second resolution

High-resolution spectra of interstellar Si IV, C IV, and N V absorption lines along the 4 kpc path to the inner Galaxy star HD 167756 at z = -0.85 kpc are presented. The spectra were obtained with the echelle mode of Goddard High Resolution Spectrograph (GHRS) aboard the Hubble Space Telescope (HST) and have signal-to-noise ratios ranging from 23 to 38. The high resolution of the measurements full width at half maximum (FWHM = 3.5 km/s) results in fully resolved line profiles for the highly ionized gas absorption. The measurements provide information on the column density per unit velocity, N(v), as a function of velocity for Si IV, C IV, and N V. The C IV and N V profiles extend from -70 to +70 km/s, while the Si IV profiles extend from -40 to +70 km/s. The integrated logarithmic column densities are long N(Si IV) = 13.09 +/- 0.02, log N(C IV) = 13.83 +/- 0.02, and log N(N V) = 13.56 +/- 0.03. The N V profile is broad, asymmetric, and featureless, while the Si IV profile contains narrow absorption components near V(sub LSR) = -19, 0, +20, and +52 km/s with Doppler spread parameters, b about = 10-12 km/s. The C IV profile contains both broad and narrow structure. The high ion feature near +52 km/s is also detected in the low-ionization lines of Ca II, O I, Si II, and Fe II. The other narrow Si IV and C IV components occur within several km/s of components seen in low-ionization species. The sight line contains at least two types of highly ionized gas. One type gives rise to a broad N V profile, and the other results in the more structured Si IV profile. The C IV profile contains contributions from both types of highly ionized gas. The broad but asymmetric N V profile is well represented by a large Galactic scale height gas which is participating in Galactic rotation and has a combination of thermal and turbulent broadening with b(sub tot) about = 42 km/s. The C IV to N V abundance ratio of 1.0 +/- 0.3 for the gas implies T about 1.6 x 10(exp 5) K or about 8 x 10(exp 5) K if the gas is in collisional ionization equilibrium and has a solar carbon to nitrogen abundance ratio. This absorption may be associated with cooling hot gas situated in Galactic shells and supershells along the sight line. The gas producing the narrow Si IV and C IV absorption components has line widths that are compatible with origins in conductive interfaces between the warm and hot interstellar medium. Kinematic flows associated with the photoionized edges of clouds might also produce Si IV and C IV lines with Doppler spread parameters similar to those observed, but the C IV to Si IV ratio in this gas is 3.5, which leads us to favor the conductive interface interpretation.

Savage, Blair D.↗

Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

The effect of clouds on the earth's solar and infrared radiation budgets

The effect of global cloudiness on the solar and infrared components of the earth's radiation balance is studied in general circulation model experiments. A wintertime simulation is conducted in which the cloud radiative transfer calculations use realistic cloud optical properties and are fully interactive with model-generated cloudiness. This simulation is compared to others in which the clouds are alternatively non-interactive with respect to the solar or thermal radiation calculations. Other cloud processes (formation, latent heat release, precipitation, vertical mixing) were accurately simulated in these experiments. It is concluded that on a global basis clouds increase the global radiation balance by 40 W/sq m by absorbing longwave radiation, but decrease it by 56 W/sq m by reflecting solar radiation to space. The net cloud effect is therefore a reduction of the radiation balance by 16 W/sq m, and is dominated by the cloud albedo effect. Changes in cloud frequency and distribution and in atmospheric and land temperatures are also reported for the control and for the non-interactive simulations. In general, removal of the clouds' infrared absorption cools the atmosphere and causes additional cloudiness to occur, while removal of the clouds' solar radiative properties warms the atmosphere and causes fewer clouds to form. It is suggested that layered clouds and convective clouds over water enter the climate system as positive feedback components, while convective clouds over land enter as negative components.

Herman, G. F.↗

Solar heating and cooling buildings

Sunshine is available in differing amounts everywhere in the world and the easiest method of capturing it is by absorption in the form of thermal energy (heat). Therefore, it is logical to utilize it directly in the heating and cooling of buildings and avoid losses that would occur by conversion to some other form. It may be emphasized that of the total energy consumed annually in the U.S., about 25% is used for heating and cooling in buildings. It is generally agreed that of all the possible widespread uses of solar energy, this application has the highest probability of success in the near term. Although there are significant uncertainties associated with some technological and economic aspects, they do not loom as large as those associated with other potentially significant applications, such as electrical power generation. It may, however, be noted that solar electrical power generation at the building site, or at a centralized station is an excellent long term prospect. Approximately 25 experimental solar heated structures have been built in various parts of the world.

Source record↗

The development of a solar residential heating and cooling system

The MSFC solar heating and cooling facility was assembled to demonstrate the engineering feasibility of utilizing solar energy for heating and cooling buildings, to provide an engineering evaluation of the total system and the key subsystems, and to investigate areas of possible improvement in design and efficiency. The basic solar heating and cooling system utilizes a flat plate solar energy collector, a large water tank for thermal energy storage, heat exchangers for space heating, and an absorption cycle air conditioner for space cooling. A complete description of all systems is given. Development activities for this test system included assembly, checkout, operation, modification, and data analysis, all of which are discussed. Selected data analyses for the first 15 weeks of testing are included, findings associated with energy storage and the energy storage system are outlined, and conclusions resulting from test findings are provided. An evaluation of the data for summer operation indicates that the current system is capable of supplying an average of 50 percent of the thermal energy required to drive the air conditioner. Preliminary evaluation of data collected for operation in the heating mode during the winter indicates that nearly 100 percent of the thermal energy required for heating can be supplied by the system.

Source record↗

Measured performance of a 3 ton LiBr absorption water chiller and its effect on cooling system operation

A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Strong Local Evaporative Cooling Over Land Due to Atmospheric Aerosols

Abstract Aerosols can enhance terrestrial productivity through increased absorption of solar radiation by the shaded portion of the plant canopy—the diffuse radiation fertilization effect. Although this process can, in principle, alter surface evaporation due to the coupling between plant water loss and carbon uptake, with the potential to change the surface temperature, aerosol‐climate interactions have been traditionally viewed in light of the radiative effects within the atmosphere. Here, we develop a modeling framework that combines global atmosphere and land model simulations with a conceptual diagnostic tool to investigate these interactions from a surface energy budget perspective. Aerosols increase the terrestrial evaporative fraction, or the portion of net incoming energy consumed by evaporation, by over 4% globally and as much as ∼40% regionally. The main mechanism for this is the increase in energy allocation from sensible to latent heat due to global dimming (reduction in global shortwave radiation) and slightly augmented by diffuse radiation fertilization. In regions with moderately dense vegetation (leaf area index >2), the local surface cooling response to aerosols is dominated by this evaporative pathway, not the reduction in incident radiation. Diffuse radiation fertilization alone has a stronger impact on gross primary productivity (+2.18 Pg C y −1 or +1.8%) than on land evaporation (+0.18 W m −2 or +0.48%) and surface temperature (−0.01 K). Our results suggest that it is important for land surface models to distinguish between quantity (change in total magnitude) and quality (change in diffuse fraction) of radiative forcing for properly simulating surface climate.

Chakraborty, TC↗

An Accurate Method for Computing the Absorption of Solar Radiation by Water Vapor

The method is based upon molecular line parameters and makes use of a far wing scaling approximation and k distribution approach previously applied to the computation of the infrared cooling rate due to water vapor. Taking into account the wave number dependence of the incident solar flux, the solar heating rate is computed for the entire water vapor spectrum and for individual absorption bands. The accuracy of the method is tested against line by line calculations. The method introduces a maximum error of 0.06 C/day. The method has the additional advantage over previous methods in that it can be applied to any portion of the spectral region containing the water vapor bands. The integrated absorptances and line intensities computed from the molecular line parameters were compared with laboratory measurements. The comparison reveals that, among the three different sources, absorptance is the largest for the laboratory measurements.

Chou, M. D.↗