Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid scintillation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The University of Chicago cosmic ray electrons and nuclei experiment on the H spacecraft

The University of Chicago instrument on the Heliocentric spacecraft (MEH experiment) will measure the energy spectrum of cosmic electrons in the range 5-400 MeV. In addition, the energy spectra and relative abundances of nuclei from protons to the iron group, with energies ranging from 30 MeV/n to 15 GeV/n, will be determined. Primary scientific objectives involve the study of the long and short term variability of these components as a probe of the structure of the heliosphere. Particles are identified by multiparameter analysis using the pulse height analyzed signals from eight active detectors - silicon solid state, plastic and crystal scintillators are solid and gas Cerenkov counters. Data return is optimized by a three level priority logic scheme.

Meyer, P.↗

The Majorana Demonstrator readout electronics system

The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Observation of Reactor Antineutrinos with a Rapidly Deployable Surface-Level Detector

We deploy a small 80 kg antineutrino detector, called MiniCHANDLER, based on a solid plastic scintillator, for nearly three months at a distance of 25 m from a 2.9 GW thermal-power-reactor core at the North Anna Nuclear Generating Station. We report the detection of an antineutrino signal resulting from inverse beta decay at 5.5σ significance with no overburden and minimal shielding. This result also demonstrates that three-dimensional segmentation can be used to significantly improve the signal-to-noise ratio, in this case by a factor of 4. Finally, in addition, this measurement represents an observation of a positron spectrum in a small surface-deployed detector; this observation of reactor antineutrinos is achieved with a mobile neutrino detector mounted in an ordinary small trailer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Individual and Simultaneous Imaging of ⁹⁹mTc and ¹⁷⁷Lu With a Preclinical Broad Energy-Spectrum CZT-Based SPECT

Radiopharmaceutical therapy has demonstrated a high efficacy in the treatment of various tumor types. One of the radionuclides already used in the clinic is 177Lu, a beta emitter that also emits several photons imageable with SPECT. Quantitative imaging of 177Lu is critical for developing new radiopharmaceuticals. Energy resolution is an important factor when imaging multiple photon emissions. Solid-state detectors offer a superior performance over scintillators, that are commonly used in commercially-available preclinical SPECT scanners. This study demonstrates the feasibility of 99m Tc and 177Lu quantitative imaging in mouse phantoms, individually and simultaneously, with a SPECT prototype built with four CdZnTe (CZT) detector heads and a custom-designed and energy-optimized parallel-hole tungsten collimator. With a custom implementation of the one-step late (OSL) image reconstruction algorithm, the system is capable of imaging energies from ~70 keV to 250 keV. Above 250 keV, images were significantly affected by septal penetration, consistent with the collimator design. A recovery coefficient within 25% was obtained for activities as low as 2 kBq/mL for 99m Tc and 45% for 177Lu. Compared to a commercial NaI-based preclinical SPECT (VECTor4/CT), our prototype showed a superior energy resolution (< 5% at 140 keV), a similar uniformity with a high-compact design.

Encarnação, Pedro M C C↗

Performance of a ton-scale water-based liquid scintillator detector

This study reports the performance and light yield of 1% concentration water-based liquid scintillator (WbLS) deployed in a 1000-liter detector. A light yield of 99± 15 photons per MeV is determined by comparing data with simulation. This result aligns with our previous light yield determination using smaller detectors, thus establishing a solid foundation for the ongoing development and deployment of WbLS in larger-scale detectors. In conclusion, the feasibility of in situ preparation and the stability of light yield in WbLS are demonstrated, reinforcing its suitability for long-term experimental endeavors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HEAO gamma-ray astronomy experiments

Two gamma ray experiments designed to measure and map the cosmic gamma ray spectrum in the 0.1 to 10 MeV region are outlined. The sensitivity and capability of the instruments- a high resolution gamma ray spectrometer that uses solid state detectors and a combined UCSD-MIT scintillation system are also given. These experiment were designed for the HEAO program.

Metzger, A. E.↗

Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment

During grant NAG5-5064, Louisiana State University (LSU) led the ATIC team in the development, construction, testing, accelerator validation, pre-deployment integration and flight operations of the Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment. This involved interfacing among the ATIC collaborators (UMD, NRL/MSFC, SU, MSU, WI, SNU) to develop a new balloon payload based upon a fully active calorimeter, a carbon target, a scintillator strip hodoscope and a pixilated silicon solid state detector for a detailed investigation of the very high energy cosmic rays to energies beyond 10(exp 14) eV/nucleus. It is in this very high energy region that theory predicts changes in composition and energy spectra related to the Supernova Remnant Acceleration model for cosmic rays below the "knee" in the all-particle spectrum. This report provides a documentation list, details the anticipated ATIC science return, describes the particle detection principles on which the experiment is based, summarizes the simulation results for the system, describes the validation work at the CERN SPS accelerator and details the balloon flight configuration. The ATIC experiment had a very successful LDB flight from McMurdo, Antarctica in 12/00 - 1/01. The instrument performed well for the entire 15 days. Preliminary data analysis shows acceptable charge resolution and an all-particle power law energy deposition distribution not inconsistent with previous measurements. Detailed analysis is underway and will result in new data on the cosmic ray charge and energy spectra in the GeV - TeV energy range. ATIC is currently being refurbished in anticipation of another LDB flight in the 2002-03 period.

Wefel, John P.↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Overview of fast particle experiments in the first MAST Upgrade experimental campaigns

Abstract MAST-U is equipped with on-axis and off-axis neutral beam injectors (NBI), and these external sources of super-Alfvénic deuterium fast-ions provide opportunities for studying a wide range of phenomena relevant to the physics of alpha-particles in burning plasmas. The MeV range D-D fusion product ions are also produced but are not confined. Simulations with the ASCOT code show that up to 20% of fast ions produced by NBI can be lost due to charge exchange (CX) with edge neutrals. Dedicated experiments employing low field side (LFS) gas fuelling show a significant drop in the measured neutron fluxes resulting from beam-plasma reactions, providing additional evidence of CX-induced fast-ion losses, similar to the ASCOT findings. Clear evidence of fast-ion redistribution and loss due to sawteeth (ST), fishbones (FB), long-lived modes (LLM), Toroidal Alfvén Eigenmodes (TAE), Edge Localised Modes (ELM) and neoclassical tearing modes (NTM) has been found in measurements with a Neutron Camera (NCU), a scintillator-based Fast-Ion Loss Detector (FILD), a Solid-State Neutral Particle Analyser (SSNPA) and a Fast-Ion Deuterium- α (FIDA) spectrometer. Unprecedented FILD measurements in the range of 1–2 MHz indicate that fast-ion losses can be also induced by the beam ion cyclotron resonance interaction with compressional or global Alfvén eigenmodes (CAEs or GAEs). These results show the wide variety of scenarios and the unique conditions in which fast ions can be studied in MAST-U, under conditions that are relevant for future devices like STEP or ITER.

Physics↗

Advanced Radiation Panel design for applications in National Security and Food Safety

We describe a new concept for a basic radiation detection panel based on conventional scintillator technology and commercially available solid-state photo-detectors. The panels are simple in construction, robust, very efficient and cost-effective and are easily scalable in size, from tens of cm 2 to tens of m 2 . We describe two possible applications: flagging radioactive food coontamination and detection of illicit radio nucleides, such as those potentially used in a terrorist attack with a dirty bomb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigation of backgrounds from cosmogenic 137 Xe in xenon gas experiments using 3 He neutron capture

136 Xe is used as the target medium for many experiments searching for 0νββ. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137 Xe created by the capture of neutrons on 136 Xe. This isotope decays via beta decay with a half-life of 3.8 minutes and a Q β of ~4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3 He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137 Xe activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Scintillator ageing of the T2K near detectors from 2010 to 2021

The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9–2.2% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator. The long component of the attenuation length of the wavelength shifting fibres was observed to degrade by 1.3–5.4% per year, while the short component of the attenuation length did not show any conclusive degradation.

47 OTHER INSTRUMENTATION↗

The acrylic vessel for JSNS 2 -II neutrino target

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS 2 -II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. Here, the specifications, design, and measured properties of the acrylic vessel are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deployment of Water-based Liquid Scintillator in the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water Cherenkov neutrino detector installed on the Booster Neutrino Beam (BNB) at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is the research and development of new detector technologies and target media. Specifically, water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of Cherenkov light and scintillation. This paper presents the deployment of a 366 L WbLS vessel in ANNIE in March 2023 and the subsequent detection of both Cherenkov light and scintillation from the WbLS. Finally, this proof-of-concept allows for the future development of reconstruction and particle identification algorithms in ANNIE, as well as dedicated analyses within the WbLS volume, such as the search for neutral-current events and the hadronic scintillation component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a bi-solvent liquid scintillator with slow light emission

One of the most promising approaches for the next generation of neutrino experiments is the realization of large hybrid Cherenkov/scintillation detectors made possible by recent innovations in photodetection technology and liquid scintillator chemistry. The development of a potentially suitable future detector liquid with particularly slow light emission is discussed in the present publication. This cocktail is compared with respect to its fundamental characteristics (scintillation efficiency, transparency, and time profile of light emission) with liquid scintillators currently used in large-scale neutrino detectors. In addition, the optimization of the admixture of wavelength shifters for a scintillator with particularly high light emission is presented. Furthermore, the pulse-shape discrimination capabilities of the novel medium was studied using a pulsed particle accelerator driven neutron source. Beyond that, purification methods based on column chromatography and fractional vacuum distillation for the co-solvent DIN (Diisopropylnaphthalene) are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗