Solid state ampere hour integrator
Current to frequency converter solid state ampere hour integrator for evaluation of space satellite batteries
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Current to frequency converter solid state ampere hour integrator for evaluation of space satellite batteries
Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.
Low data rate telemetry radio frequency solid state transmitter for telecommunication system capable of surviving high impact on lunar or planetary surface
We report results with an all-solid-state radiometer for measurements of the ClO molecule at 649 GHz. The project is part of a program to provide low-noise, low-weight, low-power radiometers for space operation, and special effort has been expended on the development of high-efficiency solid-state frequency multipliers and Schottky-barrier mixers with low local oscillator power requirements. The best measured system noise temperature was 1750 K with the mixer and preamplifier cooled to 77 K. The mixer diode was easily pumped into saturation, indicating that the design has excellent prospects of operating at higher frequencies - our present design goal being 1 THz. We comment on the principal design features of such systems and will report on stratospheric measurements performed with this system.
The development of compact spectroscopic gas sensors and their applications to environmental sensing will be described. These sensors employ mid-infrared difference-frequency generation (DFG) in periodically poled lithium niobate (PPLN) crystals pumped by two single-frequency solid state lasers such as diode lasers, diode-pumped solid state, and fiber lasers. Ultrasensitive, highly selective, and real-time measurements of several important atmospheric trace gases, including carbon monoxide, nitrous oxide, carbon dioxide, formaldehyde [correction of formaldehye], and methane, have been demonstrated.
The dependence of the frequency of self-modulation oscillations of the first kind in a solid-state ring laser on its parameters is studied theoretically and experimentally. It is shown that the nonisochronism takes place: the self-modulation oscillation frequency depends on the intracavity field intensity. The influence of the amplitude - phase coupling on the nonlinear frequency shift of self-modulation oscillations, depending on the excess of the pump over the threshold, is studied. Comparison of the experimental results with theoretical data made it possible to determine the amplitude-phase coupling coefficient. (lasers)
The dependence of the radiation frequency of a solid-state laser on the laser radiation field amplitude is studied theoretically. It is shown the non-isochronism of the laser frequency appears only when the contribution of spontaneous emission to the generated resonator mode is taken into account and is manifested most strongly at small excesses of the pump over the threshold. (control of laser radiation parameters)
The homonuclear radio-frequency driven recoupling (RFDR) experiment is commonly used in solid-state NMR spectroscopy to gain insight into the structure of biological samples due to its ease of implementation, stability towards fluctuations/missetting of radio-frequency (rf) field strength, and in general low rf requirements. A theoretical operator-based Floquet description is presented to appreciate the effect of having a temporal displacement of the π-pulses in the RFDR experiment. From this description, we demonstrate improved transfer efficiency for the RFDR experiment by generating an adiabatic passage through the zero-quantum recoupling condition. We have compared the performances of RFDR and the improved sequence to mediate efficient {sup 13}CO to {sup 13}C{sub α} polarization transfer for uniformly {sup 13}C,{sup 15}N-labeled glycine and for the fibril forming peptide SNNFGAILSS (one-letter amino acid codes) uniformly {sup 13}C,{sup 15}N-labeled at the FGAIL residues. Using numerically optimized sweeps, we get experimental gains of approximately 20% for glycine where numerical simulations predict an improvement of 25% relative to the standard implementation. For the fibril forming peptide, using the same sweep parameters as found for glycine, we have gains in the order of 10%–20% depending on the spectral regions of interest.
Solid-state batteries (SSBs) are promising next-generation batteries due to their high energy density and enhanced thermal stability and safety. However, their sluggish kinetics and transport at room temperature result in high internal impedance and critically reduce the attainable discharge energy density. Taking advantage of their strong temperature-dependent ionic conductivity, here we introduce ultra-high-frequency (greater than 105 Hz) self-heating (UHFSH) of SSBs, which can rapidly warm up the batteries from room temperature to operating temperature (∼65°C) in less than a minute. As proof of concept, UHFSH experiments were conducted on symmetric solid-state cells with lithium aluminum germanium phosphate electrolyte in different configurations. Using an experimentally validated model, pack-level simulations predict fast heating (50 K/min) and minimized heating energy consumption (less than 4%). Without any modification of the materials or structure of the batteries, our non-intrusive self-heating strategy potentially enables SSBs to discharge more than 2-fold energy in 25°C ambient.
Frequency-modulation telemetry transmitter configurations for use in 1-GHZ to 2-GHZ FREQUENCY range - solid state integrated microwave circuits
Solid-state thorium-229 ( 229 Th) nuclear clocks are set to provide new opportunities for precision metrology and fundamental physics. Taking advantage of inherent low sensitivity of a nuclear transition to its environment, orders of magnitude more emitters can be hosted in a solid-state crystal compared with current optical lattice atomic clocks. Furthermore, solid-state systems needing only simple thermal control are key to the development of field-deployable compact clocks. Here we explore and characterize the frequency reproducibility of the 229 Th:CaF 2 nuclear clock transition, a key performance metric for all clocks. We measure the transition linewidth and centre frequency as a function of the doping concentration, temperature and time. We report the concentration-dependent inhomogeneous linewidth of the nuclear transition, limited by the intrinsic host crystal properties. We determine an optimal working temperature for the 229 Th:CaF 2 nuclear clock at 196(5) K, at which the first-order thermal sensitivity vanishes. This would enable in situ temperature co-sensing using different quadrupole-split lines, reducing the temperature-induced systematic shift below the 10 −18 fractional frequency uncertainty level. At 195 K, the reproducibility of the nuclear transition frequency is 220 Hz (fractionally 1.1 × 10 −13 ) for two differently doped 229 Th:CaF 2 crystals over 7 months. Furthermore, these results form the foundation for understanding, controlling and harnessing the coherent nuclear excitation of 229 Th in solid-state hosts and for their applications in constraining temporal variations of fundamental constants.
A primary limitation of many solid-state photodetectors used in electro-optical systems such as the facsimile camera is their slow response in converting light intensities into electrical signals. An optical feedback technique is presented which can extend the frequency response of systems that use these detectors by orders of magnitude without significantly degrading their signal-to-noise performance. This technique is analyzed to predict improvement, implemented, and evaluated to verify analytical results.
Solid state laser sources, such as diode-pumped Nd:YAG lasers, have given us CW laser light of high power with unprecedented stability and low noise performance. In these lasers most of the technical sources of noise can be eliminated allowing them to be operated close to the theoretical noise limit set by the quantum properties of light. The next step of reducing the noise below the standard limit is known as squeezing. We present experimental progress in generating reliably squeezed light using the process of frequency doubling. We emphasize the long term stability that makes this a truly practical source of squeezed light. Our experimental results match noise spectra calculated with our recently developed models of coupled systems which include the noise generated inside the laser and its interaction with the frequency doubler. We conclude with some observations on evaluating quadrature squeezed states of light.
Research on very low frequency propagation, solid state and electron physics, automatic control, communications and networks, microwave materials, and electromagnetic radiation
Design, packaging, circuitry, and testing of solid state superhigh frequency transmitter using step recovery diode frequency multiplier
A solid state device chip including diodes (generating a higher frequency output through frequency multiplication of the input frequency) and a novel on-chip power combining design. Together with the on-chip power combining, the chip has increased efficiency because the diodes' anodes, being micro-fabricated simultaneously on the same patch of a GaAs wafer under identical conditions, are very well balanced. The diodes' GaAs heterostructure and the overall chip geometry are designed to be optimized for high power operation. As a result of all these features, the device can generate record-setting power having a signal frequency in the F-band and W-band (30% conversion efficiency).
TOPEX/POSEIDON is the first space mission specifically designed and conducted for studying the circulation of the world's oceans. A state-of-the-art radar altimetry system is used to measure the precise height of sea level, from which information on the ocean circulation is obtained. The satellite, launched on August 10, 1992, has been making observations of the global oceans with unprecedented accuracy since late September 1992. To meet the stringent measurement accuracy required for ocean circulation studies, a number of innovative improvements have been made to the mission design, including the first dual-frequency space-borne radar altimeter capable of retrieving the ionospheric delay of the radar signal, a three-frequency microwave radiometer for retrieving the signal delay caused by the water vapor in the troposphere, an optimal model of the Earth's gravity field and multiple satellite tracking systems for precision orbit determination. Additionally, the satellite also carries two experimental instruments to demonstrate new technologies: a single-frequency solid-state altimeter for the technology of low-power, low-weight altimeter and a Global Positioning System receiver for continuous,precise satellite tracking. The performance of the mission's measurement system has been tested by numerous verification studies. The results indicate that the root-sum-square accuracy of a single-pass sea level measurement is 4.7 cm for the TOPEX system and 5.1 cm for the POSEIDON system; both are more than a factor of 2 better than the requirement of 13.7 cm. This global data set is being analyzed to improve understanding of the global ocean circulation as well as the ocean tides, geodesy, and geodynamics, and ocean wind and waves. The mission is designed to last for at least 3 years with a possible extension to 6 years. The multiyear global data set will go a long way toward understanding the ocean circulation and its variability in relation to climate change. A summary of the mission's systems and their performance as well as the mission's science team is presented.
Design and operational performance of solid state ultrahigh frequency prototype telemetry transmitter