Search NASA⌕ Search

SEARCH · Search NASA

Results for “sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Source Breakup Dynamics in Au+Au Collisions at {radical}(s{sub NN})=200 GeV via Three-Dimensional Two-Pion Source Imaging

A three-dimensional correlation function obtained from midrapidity, low p{sub T}, pion pairs in central Au+Au collisions at {radical}(s{sub NN})=200 GeV is studied. The extracted model-independent source function indicates a long range tail in the directions of the pion pair transverse momentum (out) and the beam (long). A proper breakup time {tau}{sub 0}{approx}9 fm/c and a mean proper emission duration {delta}{tau}{approx}2 fm/c, leading to sizable emission time differences (<|{delta}t{sub LCM}|>{approx_equal}12 fm/c), are required to allow models to be successfully matched to these tails. The model comparisons also suggest an outside-in 'burning' of the emission source reminiscent of many hydrodynamical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

J-type Carbon Stars: A Dominant Source of 14 N-rich Presolar SiC Grains of Type AB

Here, we report Mo isotopic data of 27 new presolar SiC grains, including 12 14 N-rich AB ( 14 N/ 15 N > 440, AB2) and 15 mainstream (MS) grains, and their correlated Sr and Ba isotope ratios when available. Direct comparison of the data for the MS grains, which came from low-mass asymptotic giant branch (AGB) stars with large s-process isotope enhancements, with the AB2 grain data demonstrates that AB2 grains show near-solar isotopic compositions and lack s-process enhancements. The near-normal Sr, Mo, and Ba isotopic compositions of AB2 grains clearly exclude born-again AGB stars, where the intermediate neutron-capture process (i-process) takes place, as their stellar source. On the other hand, low-mass CO novae and early R- and J-type carbon stars show 13 C and 14 N excesses but no s-process enhancements and are thus potential stellar sources of AB2 grains. And because both early R-type carbon stars and CO novae are rare objects, the abundant J-type carbon stars (10%–15% of all carbon stars) are thus likely to be a dominant source of AB2 grains.

58 GEOSCIENCES↗

Fast and efficient charge breeding of the Californium rare isotope breeder upgrade electron beam ion source

The Electron Beam Ion Source (EBIS), developed to breed Californium Rare Isotope Breeder Upgrade (CARIBU) radioactive beams at Argonne Tandem Linac Accelerator System (ATLAS), is being tested off-line. A unique property of the EBIS is a combination of short breeding times, high repetition rates, and a large acceptance. Overall, we have implemented many innovative features during the design and construction of the CARIBU EBIS as compared to the existing EBIS breeders. The off-line charge breeding tests are being performed using a surface ionization source that produces singly charged cesium ions. The main goal of the off-line commissioning is to demonstrate stable operation of the EBIS at a 10 Hz repetition rate and a breeding efficiency into single charge state higher than 15%. These goals have been successfully achieved and exceeded. We have measured (20% ± 0.7%) breeding efficiency into the single charge state of 28+ cesium ions with the breeding time of 28 ms. In general, the current CARIBU EBIS operational parameters can provide charge breeding of any ions in the full mass range of periodic table with high efficiency, short breeding times, and sufficiently low charge-to-mass ratio, 1/6.3 for the heaviest masses, for further acceleration in ATLAS. In this study, we discuss the parameters of the EBIS and the charge breeding results in a pulsed injection mode with repetition rates up to 10 Hz.

43 PARTICLE ACCELERATORS↗

Open-Source Framework for Data Storage and Visualization of Real-Time Experiments

Digital real time simulators (DRTS) are increasingly being used for the evaluation of power hardware and controller hardware in the laboratory prior to field deployment. Although DRTS are capable of simulating large models in real-time, it is challenging to visualize the results of large models without overdrawing or confounding the viewer. This paper provides an open-source framework for users to visualize their DRTS-based hardware-in-the-loop (HIL) experimental results in real-time. This proposed framework can be used by experimental test beds that can push data through an internet protocol based network. The proposed framework includes three main components. First, it includes the DRTS that generates and pushes the data to a relay. Second, it includes an application that serves multiple purposes, from data storage, testing, and translation of the data to a publisher/subscriber protocol. Finally, it includes libraries and applications that can be used to visualize the data by subscribing to the relay. This framework is available in open source, and it is tested using the HIL platform developed for testing advanced distribution management systems.

advanced distribution management systems↗

Relative Source Time Functions, Spectral Ratios, and Near‐Source Spallation in the Source Physics Experiment Phase I Chemical Explosions

The Source Physics Experiment (SPE) Phase I was composed of six chemical explosions at the Nevada National Security Sites (NNSS) between 2011 and 2016. The experiment provided a robust set of dense, local to regional distance observations suitable for characterizing shallow chemical explosions located within the same borehole. We investigate the time-dependent source processes of each chemical explosion using Relative Source Time Function (RSTF) estimation, derived from five linear seismometer profiles located between 100 and 2000 m of the shot location. The RSTF estimate provide a detailed characterization of each chemical explosion's time-history. Subsequent modeling efforts suggest these measurements may be useful for precise characterization of explosion processes and spallation. RSTF estimation allows us to expand our understanding of the SPE Phase I chemical explosion series. Application of these techniques contributes to our understanding of explosion source physics and facilitates future applications to additional seismic source experiments and characterization of explosion phenomenology.

58 GEOSCIENCES↗

Enabling instrumentation and technology for 21st century light sources

We present the summary from the Accelerator Instrumentation and Technology working group, one of the five working groups that participated in the BES-sponsored Workshop on Accelerator Physics of Future Light Sources held in Gaithersburg, MD September 15–17, 2009. We describe progress and potential in three areas: attosecond instrumentation, photon detectors for user experiments, and insertion devices.

Instrumentation↗

Collaborative development of diffraction-limited beamline optical systems at US DOE light sources

An ongoing collaboration among four US Department of Energy National Laboratories has demonstrated key technology prototypes and software modeling tools required for new high-coherent flux beamline optical systems. New free electron laser (FEL) and diffraction-limited storage ring (DLSR) light sources demand wavefront preservation from source to sample to achieve and maintain optimal performance. Fine wavefront control was achieved using a novel, roomtemperature cooled mirror system called REAL (resistive element adjustable length) that combines cooling with applied, spatially variable auxiliary heating. Single-grating shearing interferometry (also called Talbot interferometry) and Hartmann wavefront sensors were developed and used for optical characterization and alignment on several beamlines, across a range of photon energies. Demonstrations of non-invasive hard x-ray wavefront sensing were performed using a thin diamond single-crystal as a beamsplitter.

Goldberg, Kenneth A.↗

Laser ion source for isobaric heavy ion collider experiment

Heavy-ion collider experiment in isobaric system is under investigation at Relativistic Heavy Ion Collider. For this experiment, ion source is required to maximize the abundance of the intended isotope. The candidate of the experiment is {sup 96}Ru + {sup 96}Zr. Since the natural abundance of particular isotope is low and composition of isotope from ion source depends on the composites of the target, an isotope enriched material may be needed as a target. We studied the performance of the laser ion source required for the experiment for Zr ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open-source MFIX-DEM software for gas–solids flows: Part I—Verification studies

With rapid advancements in computer hardware, it is now possible to perform large simulations of granular flows using the Discrete Element Method (DEM). As a result, solids are increasingly treated in a discrete Lagrangian fashion in the gas–solids flow community. In this paper, the open-source MFIX-DEM software is described that can be used for simulating the gas–solids flow using an Eulerian reference frame for the continuum fluid and a Lagrangian discrete framework (Discrete Element Method) for the particles. This method is referred to as the continuum discrete method (CDM) to clearly make a distinction between the ambiguity of using a Lagrangian or Eulerian reference for either continuum or discrete formulations. This freely available CDM code for gas–solids flows can accelerate the research in computational gas–solids flows and establish a baseline that can lead to better closures for the continuum modeling (or traditionally referred to as two fluid model) of gas–solids flows. In this paper, a series of verification cases is employed which tests the different aspects of the code in a systematic fashion by exploring specific physics in gas–solids flows before exercising the fully coupled solution on simple canonical problems. It is critical to have an extensively verified code as the physics is complex with highly-nonlinear coupling, and it is difficult to ascertain the accuracy of the results without rigorous verification. These series of verification tests set the stage not only for rigorous validation studies (performed in part II of this paper) but also serve as a procedure for testing any new developments that couple continuum and discrete formulations for gas–solids flows.

Computational fluid dynamics↗

Developing a bright 17 keV x-ray source for probing high-energy-density states of matter at high spatial resolution

A set of experiments were performed on the National Ignition Facility (NIF) to develop and optimize a bright, 17 keV x-ray backlighter probe using laser-irradiated Nb foils. High-resolution one-dimensional imaging was achieved using a 15 μm wide slit in a Ta substrate to aperture the Nb He{sub α} x-rays onto an open-aperture, time integrated camera. To optimize the x-ray source for imaging applications, the effect of laser pulse shape and spatial profile on the target was investigated. Two laser pulse shapes were used—a “prepulse” shape that included a 3 ns, low-intensity laser foot preceding the high-energy 2 ns square main laser drive, and a pulse without the laser foot. The laser spatial profile was varied by the use of continuous phase plates (CPPs) on a pair of shots compared to beams at best focus, without CPPs. A comprehensive set of common diagnostics allowed for a direct comparison of imaging resolution, total x-ray conversion efficiency, and x-ray spectrum between shots. The use of CPPs was seen to reduce the high-energy tail of the x-ray spectrum, whereas the laser pulse shape had little effect on the high-energy tail. The measured imaging resolution was comparably high for all combinations of laser parameters, but a higher x-ray flux was achieved without phase plates. This increased flux was the result of smaller laser spot sizes, which allowed us to arrange the laser focal spots from multiple beams and produce an x-ray source which was more localized behind the slit aperture. Our experiments are a first demonstration of point-projection geometry imaging at NIF at the energies (>10 keV) necessary for imaging denser, higher-Z targets than have previously been investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National Synchrotron Light Source II storage ring vacuum systems

The National Synchrotron Light Source II, completed in 2014, is a 3-GeV synchrotron radiation (SR) facility at Brookhaven National Laboratory and has been in steady operation since. With a design electron current of 500 mA and subnanometer radians horizontal emittance, this 792-m circumference storage ring is providing the highest flux and brightness x-ray beam for SR users. The majority of the storage ring vacuum chambers are made of extruded aluminium. Chamber sections are interconnected using low-impedance radiofrequency shielded bellows. SR from the bending magnets is intercepted by water-cooled compact photon absorbers resided in the storage ring chambers. This paper presents the design of the storage ring vacuum system, the fabrication of vacuum chambers and other hardware, the installation, the commissioning, and the continuing beam conditioning of the vacuum systems.

43 PARTICLE ACCELERATORS↗

{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design

Purpose: A new type of{sup 103}Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains {sup 103}Pd and Au radio-opaque marker(s), all contained within low-Z{sub eff} organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional {sup 103}Pd seeds. Methods: The MCNP5 radiation transport code was used to estimate air-kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG-43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: The normalized air-kerma rate was not highly dependent onL or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L. The air-kerma strength was also weakly dependent on L. The uncertainty analysis established a standard uncertainty of 1.3% for the dose-rate constant Λ, where the largest contributors were μ{sub en}/ρ and μ/ρ. The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r < 1 cm indicated that the Au marker(s) shielded radiation for the sources having L = 10, 30, and 50 mm. The 2D anisotropy function exhibited peaks and valleys that corresponded to positions adjacent to {sup 103}Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional {sup 103}Pd seeds. Contributions by 2.7 keV photons comprised ≤0.1% of the dose from all photons at positions farther than 0.13 mm from the polymer source surface. Differences between absorbed dose to water and prostate became more substantial as distance from the sources increased, with prostate dose being about 13% lower for r = 5 cm. Using a cylindrical coordinate system, dose superposition of small length sources to replicate the dose distribution for a long length source proved to be a robust technique; a 2.0% tolerance compared with the reference dose distribution did not exceed 0.1 cm{sup 3} for any of the examined source combinations. Conclusions: By design, the CivaString and CivaThin sources have novel dosimetric characteristics in comparison to Ti-encapsulated{sup 103}Pd seeds. The dosimetric characterization has determined the reasons for these differences through analysis using Monte Carlo-based radiation transport simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗