Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatio-temporal data fusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 records · Page 2

Final report- UFL - RAPIDS2: A SciDAC Institute for Computer Science, Data, and Artificial Intelligence

The research initiatives supported by the U.S. Department of Energy (DOE) Grant DE-SC0022265 are fundamentally aimed at pioneering advanced machine learning (ML) techniques for scientific data compression within high-performance computing (HPC) environments. This comprehensive body of work addresses the critical challenge posed by the exponential growth of data generated by scientific simulations in domains such as fusion energy, climate modeling, and computational fluid dynamics (CFD). A core objective is to develop compression algorithms that achieve substantial data reduction—often by orders of magnitude—while rigorously ensuring the fidelity of both the primary data (PD) and scientifically crucial derived quantities of interest (QoI). The methodologies deployed under this grant integrate sophisticated deep learning architectures, prominently featuring autoencoders, advanced generative models like conditional diffusion, and hybrid learning techniques. Key innovations include the development of Guaranteed Autoencoders (GAE) and the Guaranteed Conditional Diffusion with Tensor Correction (GCDTC) framework, which provide explicit, instance-level error bounds on reconstructed data. Furthermore, specialized strategies such as nonlinear constraint satisfaction are employed to preserve the integrity of QoI, a vital requirement for the trustworthiness of downstream scientific analyses. This research also focuses on the design and implementation of scalable, GPU-accelerated software pipelines that seamlessly integrate into existing HPC workflows, ensuring both computational efficiency and practical applicability. The CAESAR framework, for example, unifies foundation and generative models to create an adaptive and efficient compression solution for spatio-temporal scientific data. Collectively, these efforts represent a significant advancement in mitigating the scientific data deluge, enabling more effective data management, accelerated scientific discovery, and optimized utilization of HPC resources.

97 MATHEMATICS AND COMPUTING↗

Characterizing magnetized plasmas with dynamic mode decomposition

Accurate and efficient plasma models are essential to understand and control experimental devices. Existing magnetohydrodynamic or kinetic models are nonlinear and computationally intensive and can be difficult to interpret, while often only approximating the true dynamics. In this work, data-driven techniques recently developed in the field of fluid dynamics are leveraged to develop interpretable reduced-order models of plasmas that strike a balance between accuracy and efficiency. In particular, dynamic mode decomposition (DMD) is used to extract spatio-temporal magnetic coherent structures from the experimental and simulation datasets of the helicity injected torus with steady inductive (HIT-SI) experiment. Three-dimensional magnetic surface probes from the HIT-SI experiment are analyzed, along with companion simulations with synthetic internal magnetic probes. A number of leading variants of the DMD algorithm are compared, including the sparsity-promoting and optimized DMD. Optimized DMD results in the highest overall prediction accuracy, while sparsity-promoting DMD yields physically interpretable models that avoid overfitting. These DMD algorithms uncover several coherent magnetic modes that provide new physical insights into the inner plasma structure. These modes were subsequently used to discover a previously unobserved three-dimensional structure in the simulation, rotating at the second injector harmonic. Finally, using data from probes at experimentally accessible locations, DMD identifies a resistive kink mode, a ubiquitous instability seen in magnetized plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FLEET velocimetry measurements in the ONR-UTA arc-jet wind tunnel

This manuscript presents and discusses the very first successful application of the Femtosecond Laser Electronic Excitation Tagging (FLEET) velocimetry technique in an arc-jet flow. Specifically, one-dimensional, quantitative, FLEET velocimetry data were obtained in the effort to characterize the 1.6 MW ONR-UTA arc-jet plasma wind tunnel, Leste, housed at the Aerodynamics Research Center of the University of Texas at Arlington. While the FLEET technique has been used in other types of high-speed wind tunnel facilities, application to flows with high background radiation, such as arc-jets, has never been demonstrated before this work. The high background emissions posed concerns on the feasibility of performing FLEET velocimetry measurements. However, this work demonstrates how these concerns were addressed and presents the first successful application of the FLEET technique in arc-jet flows. The FLEET emissions in the arc-jet plume were successfully imaged, and a significant spatio-temporal variation in the tag’s displacement was observed. For the selected operational condition in this study, the average measured gas velocity in the arc-jet plume was 1.78 km/s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution density pedestal measurements during edge localized modes by short-pulse reflectometry in the TCV tokamak

This publication presents high spatio-temporal resolution (mm/μs) density profile measurements of the pedestal top during type I, III, and small edge localized mode (ELM) H-mode plasmas in the Tokamak à Configuration Variable (TCV). These measurements were performed using a novel short-pulse reflectometer. Average inter-ELM density profiles are obtained via conditional averaging using the Dα trace as ELM indicator. Changes to the pedestal density profile gradients prior to type-III ELMs reveal unique pedestal dynamics leading to the ELM crash which can provide important experimental data for validation of non-linear MHD ELM simulations. The small-ELM scenario is found to feature a ∼25-35 kHz quasi-coherent density fluctuation near the separatrix rho_psi ∼0.993-1.05 not observed during a similar type-I ELM discharge. This oscillation is also found in low-field-side magnetic pick- up probes displaying a ballooning character and n=+1 toroidal mode number. This oscillation could help explain the markedly different pedestal dynamics observed in the small-ELM regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution density pedestal measurements during edge localized modes by short-pulse reflectometry in the TCV tokamak

Here, this publication presents high spatio-temporal resolution (mm µs -1 ) density profile measurements of the pedestal top during type I, III, and small edge localized mode (ELM) H-mode plasmas in the tokamak à configuration variable (TCV). These measurements were performed using a novel short-pulse reflectometer. Average inter-ELM density profiles are obtained via conditional averaging using the D α trace as ELM indicator. Changes to the pedestal density profile gradients prior to type-III ELMs reveal unique pedestal dynamics leading to the ELM crash which can provide important experimental data for validation of non-linear MHD ELM simulations. The small-ELM scenario is found to feature a ~25–35 kHz quasi-coherent density fluctuation near the separatrix ρ ψ 0.993–1.05 not observed during a similar type-I ELM discharge. This oscillation is also found in low-field-side magnetic pick-up probes displaying a ballooning character and n = +1 toroidal mode number. This oscillation could help explain the markedly different pedestal dynamics observed in the small-ELM regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and computational study of complex shockwave dynamics in laser ablation plumes in argon atmosphere

We investigated spatio-temporal evolution of ns laser ablation plumes at atmospheric pressure, a favored condition for laser-induced breakdown spectroscopy and laser-ablation inductively coupled plasma mass-spectrometry. The 1064 nm, 6 ns pulses from a Nd:YAG laser were focused on to an Al target and the generated plasma was allowed to expand in 1 atm Ar. The hydrodynamic expansion features were studied using focused shadowgraphy and gated 2 ns self-emission visible imaging. Shadowgram images showed material ejection and generation of shock fronts. A secondary shock is observed behind the primary shock during the time window of 100-500 ns with instabilities near the laser cone angle. By comparing the self-emission images obtained using fast photography, it is concluded that the secondary shocks observed in the shadowgraphy were generated by fast moving target material. The plume front estimates using fast photography exhibited reasonable agreement with data obtained from shadowgraphy at early times {<=}400 ns. However, at later times, fast photography images showed plume confinement while the shadowgraphic images showed propagation of the plume front even at greater times. The structure and dynamics of the plume obtained from optical diagnostic tools were compared to numerical simulations. We have shown that the main features of plume expansion in ambient Ar observed in the experiments can be reproduced using a continuum hydrodynamics model which provided valuable insight into the expansion dynamics and shock structure of the plasma plume.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-modal dynamic radiography using short-pulse laser-generated probe beams

Radiography is an important tool for the interrogation of dynamic experiments in the fields of dynamic properties of materials, and in condensed matter, high explosive, and high-energy-density physics. Multi-modal radiography advances the hypothesis that combining the information delivered by multiple radiographic modalities can lead to more constrained (improved) “reconstruction” of the scene than can be obtained from a single probe. We identify four modalities: multi-probe, time sequence, multi-view, and multi-messenger. Multi-probe radiography is a promising candidate for a next-generation dynamic radiographic facility. High-energy X-rays are the most frequently used probe for dynamic radiography, although recent developments show the utility of proton (pRad), electron (eRad), and neutron probe beams. Because each probing species interacts with material in the radiographic scene through quantitatively different mechanisms, each returns independent information about the scene, which can add extra constraints to the reconstruction process. How to conduct detailed, quantitative “co-analysis” of multiple data streams remains an area of active research. Multi-beam, short-pulse, laser-generated probes offer sufficient dose, an appropriate spectrum, and appropriate spatio-temporal resolution to produce high-quality dynamic radiographs. This paper reports on technology development to advance the state of the art of multi-modal/multi-probe radiography and the pursuit of both deterministic and inferential (AI/ML assisted) co-analysis methodologies to produce more constrained reconstructions from multi-modal data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benchmarking a novel ultrasound-CT fusion system for respiratory motion management in radiotherapy: Assessment of spatio-temporal characteristics and comparison to 4DCT

Management of respiratory motion during radiation therapy requires treatment planning and simulation using imaging modalities that possess sufficient spatio-temporal accuracy and precision. An investigation into the use of a novel ultrasound (United States) imaging system for assessment of respiratory motion is presented, exploiting its good soft tissue contrast and temporal precision. The system dynamically superimposes the appropriate image plane sampled from a reference CT data set with the corresponding US B-mode image. An articulating arm is used for spatial registration. While the focus of the study was to quantify the system's ability to track respiratory motion, certain unique spatial calibration procedures were devised that render the software potentially valuable to the general research community. These include direct access to all transformation matrix elements and image scaling factors, a manual latency correction function, and a three-point spatial registration procedure that allows the system to be used in any room possessing a traditional radiotherapy laser localization system. Counter-intuitively, it was discovered that a manual procedure for calibrating certain transformation matrix elements produced superior accuracy to that of an algorithmic Levenberg-Marquardt optimization method. The absolute spatial accuracy was verified by comparing the physical locations of phantom test objects measured using the spatially registered US system, and using data from a 3DCT scan of the phantom as a reference. The spatial accuracy of the display superposition was also tested in a similar manner. The system's dynamic properties were then assessed using three methods. First, the overall system response time was studied using a programmable motion phantom. This included US video update, articulating arm update, CT data set resampling, and image display. The next investigation verified the system's ability to measure the range of motion of a moving anatomical test phantom that possessed both high and low contrast test objects. Finally, the system's performance was compared to that of a four-dimensional CT (4DCT) data set. The absolute spatial and display superposition accuracy was found to be better than 2 mm and typically 1 mm. Overall dynamic system response was adequate to produce a mean relative positional error of less than 1 mm if an empiric latency correction of 3 video frames was incorporated. The dynamic CT/US display mode was able to assess phantom motion for both high and low contrast test objects to within 1 mm, and compared favorably to the 4DCT data. The 4DCT movie loop accurately assessed the target motion for both of the high and low contrast objects tested, but the minimum intensity and average intensity reconstructions did not. This investigation demonstrated that this US system possesses sufficient spatio-temporal accuracy to properly assess respiratory motion. Future work will seek to demonstrate efficacy in its clinical application to respiratory motion assessment, particularly for sites in the upper abdomen, where low tissue contrast is evident.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Matching high resolution satellite data and flux tower footprints improves their agreement in photosynthesis estimates

Mapping canopy photosynthesis in both high spatial and temporal resolution is essential for carbon cycle monitoring in heterogeneous areas. However, well established satellites in sun-synchronous orbits such as Sentinel-2, Landsat and MODIS can only provide either high spatial or high temporal resolution but not both. Recently established CubeSat satellite constellations have created an opportunity to overcome this resolution trade-off. In particular, Planet Fusion allows full utilization of the CubeSat data resolution and coverage while maintaining high radiometric quality. In this study, we used the Planet Fusion surface reflectance product to calculate daily, 3-m resolution, gap-free maps of the near-infrared radiation reflected from vegetation (NIRvP). We then evaluated the performance of these NIRvP maps for estimating canopy photosynthesis by comparing with data from a flux tower network in Sacramento-San Joaquin Delta, California, USA. Overall, NIRvP maps captured temporal variations in canopy photosynthesis of individual sites, despite changes in water extent in the wetlands and frequent mowing in the crop fields. When combining data from all sites, however, we found that robust agreement between NIRvP maps and canopy photosynthesis could only be achieved when matching NIRvP maps to the flux tower footprints. In this case of matched footprints, NIRvP maps showed considerably better performance than in situ NIRvP in estimating canopy photosynthesis both for daily sum and data around the time of satellite overpass (R2 = 0.78 vs. 0.60, for maps vs. in situ for the satellite overpass time case). This difference in performance was mostly due to the higher degree of consistency in slopes of NIRvP-canopy photosynthesis relationships across the study sites for flux tower footprint-matched maps. Our results show the importance of matching satellite observations to the flux tower footprint and demonstrate the potential of CubeSat constellation imagery to monitor canopy photosynthesis remotely at high spatio-temporal resolution.

54 ENVIRONMENTAL SCIENCES↗

Temporally-consistent koopman autoencoders for forecasting dynamical systems

Absence of sufficiently high-quality data often poses a key challenge in data-driven modeling of high-dimensional spatio-temporal dynamical systems. Koopman Autoencoders (KAEs) harness the expressivity of deep neural networks (DNNs), the dimension reduction capabilities of autoencoders, and the spectral properties of the Koopman operator to learn a reduced-order feature space with simpler, linear dynamics. However, the effectiveness of KAEs is hindered by limited and noisy training datasets, leading to poor generalizability. To address this, we introduce the Temporally-Consistent Koopman Autoencoder (tcKAE), designed to generate accurate long-term predictions even with limited and noisy training data. This is achieved through a consistency regularization term that enforces prediction coherence across different time steps, thus enhancing the robustness and generalizability of tcKAE over existing models. We provide analytical justification for this approach based on Koopman spectral theory and empirically demonstrate tcKAE’s superior performance over state-of-the-art KAE models across a variety of test cases, including simple pendulum oscillations, kinetic plasma, and fluid flow data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fully Convolutional Spatio-Temporal Models for Representation Learning in Plasma Science

We have trained a fully convolutional spatio-temporal model for fast and accurate representation learning in the challenging exemplar application area of fusion energy plasma science. The onset of major disruptions is a critically important fusion energy science issue that must be resolved for advanced tokamak plasmas such as the $25B burning plasma international thermonuclear experimental reactor (ITER) experiment. While a variety of statistical methods have been used to address the problem of tokamak disruption prediction and control, recent approaches based on deep learning have proven particularly compelling. In the present paper, we introduce further improvements to the fusion recurrent neural network (FRNN) software suite, which delivered cross-machine disruption predictions with unprecedented accuracy using a large database of experimental signals from two major tokamaks. Up to now, FRNN was based on the long short-term memory (LSTM) variant of recurrent neural networks to leverage the temporal information in the data. Here, we implement and apply the "temporal convolutional neural network (TCN)" architecture to the time-dependent input signals. Furthermore, this allows highly optimized convolution operations to carry the majority of the computational load of training, thus enabling a reduction in training time, and the effective use of high-performance computing resources for hyperparameter tuning. At the same time, the TCN-based architecture achieves better predictive performance when compared with the LSTM architecture for various tasks for a representative fusion database.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗