Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral bands”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Selection of a seventh spectral band for the LANDSAT-D thematic mapper

The author has identified the following significant results. Each of the candidate bands were examined in terms of the feasibility of gathering high quality imagery from space while taking into account solar illumination, atmospheric attenuation, and the signal/noise ratio achievable within the TM sensor constraints. For the 2.2 micron region and the thermal IR region, inband signal values were calculated from representative spectral reflectance/emittance curves and a linear discriminant analysis was employed to predict classification accuracies. Based upon the substantial improvement (from 78 t0 92%) in discriminating zones of hydrothermally altered rocks from unaltered zones, over a broad range of observation conditions, a 2.08-2.35 micron spectral band having a ground resolution of 30 meters was recommended.

Holmes, Q. A.↗

Deep galaxy count predictions in the radio, infrared, and X-ray spectral bands

The existence of a dominant population of strongly evolving starburst sources at moderate redshift is a plausible explanation for the excess number of faint blue galaxies detected in deep sky surveys. Multiwavelength observations at faint magnitudes would allow the existence of such a population to be confirmed. We use observed luminosity correlations and physical properties of known starburst galaxies to predict their contribution to the deep radio, infrared, and X-ray counts, as well as to the diffuse extragalactic background radiation in these various spectral bands.

Treyer, Marie-Agnes↗

Improvements of On-orbit Characterization of Terra MODIS Short-wave Infrared Spectral Bands Out-of-Band Responses

The short-wave infrared (SWIR) bands (5-7, 26) of Terra MODIS, which are co-located with the mid-wav e infrared (MWIR) bands (20-25) on the short and mid-wave infrared (SMIR) Focal Plane Assembly (FPA),have a known issue related to 5.3 μm out-of-band (OOB) thermal leak and electronic crosstalk that was identified prelaunch. As a result, a crosstalk correction algorithm was designed and implemented in the MODIS Level 1B (L1B) calibration. Shortly after the Terra launch, extensive efforts were under taken to help characterize and mitigate the impact due to the OOB response and crosstalk on the SWIR on-orbit calibration and, consequently, the associated L1Bdata products. In addition, special night time day mode (NTDM) operations have been regularly scheduled to derive the crosstalk correction coefficients. Since MODIS does not have a spectral band centered at 5.3 μm, its band 28 (7.325 μm) was chosen as the surrogate sending band to simulate the OOB radiances at 5.3 μm. This was largely based on the measurements from the MODIS Airborne Simulator (MAS) spectrometer field campaigns in the early months after the Terra launch. In the case of Aqua MODIS, the magnitude of the SWIR crosstalk was much smaller and band 25 (4.52 μm) was found to be more effective as the sending band for the crosstalk correction. In recent years, the Terra MODIS photovoltaic (PV) long-wave infrared (LWIR) bands (27-30)electronic crosstalk has increased considerably, especially after the spacecraft safe-mode event occurred in February2016. This accentuated degradation in the PV LWIR performance has also impacted the performance of the SWIR crosstalk correction and thus its calibration and data quality. In this paper, we examine the use of band 25 as the sending band for the Terra MODIS SWIR crosstalk correction and compare its performance with that based on band 28 as the sending band. Results indicate an improvement of on-orbit gain stability for the SWIR calibration and reduced detector to detector and sub-frame to sub-frame striping in the calibrated L1B imagery, especially during the period when the PV LWIR electronic crosstalk has become more severe. This approach has been implemented in the forward production of Terra MODIS Collection 6 and Collection 6.1,starting from July 2019, and is planned to be used for the future reprocessing of MODIS L1B and to help improve the mission-long reflectance calibration and trending stability of the SWIR bands.

MODIS, Terra, Aqua, MODIS, SWIR, calibration, out-↗

Evaluation of Spectral Band Adjustment Factors for Cross-Calibration of Visible Imagers

The CERES EBAF dataset provides TOA SW and LW fluxes for long-term monitoring of the Earth’s energy balance and to validate climate models. The EBAF products, based on the Terra and Aqua CERES instrument observed radiances, rely on coincident measurements from the onboard MODIS imagers to determine cloud properties that are used in the angular distribution model scene selection required to convert the CERES observed radiances into flux values. Once the Terra and Aqua orbits start drifting outside of their 15-minute window, the CERES project will rely solely on the NOAA-20 CERES observations. A seamless transition of fluxes and clouds can only occur if the analogous MODIS and VIIRS channels are properly inter-calibrated. The visible band (0.65 µm) in MODIS (band 1) and VIIRS (M5 or I1) is critical for retrieving the cloud mask and optical depth. The spectral response functions (SRF) of these bands differ noticeably and will require scene dependent spectral band adjustment factors (SBAF) for proper radiometric scaling between them. Fortunately, the VIIRS I1 and M5 bands are calibrated using the same solar diffuser as a reference, which implies that band reflectance differences must be due to the spectral disparity. The coincident I1 and M5 TOA reflectance measurements provide the optimal opportunity to validate SBAFs over many surface and cloud conditions. The CERES project maintains SCIAMACHY, GOME-2, Hyperion, and radiative transfer model-based scene-stratified hyper-spectral reflectance measurements that can be convolved with sensor pair SRFs to compute the corresponding SBAF. This study will evaluate the SCIAMACHY, GOME-2, Hyperion, and RTM based SBAFs over tropical ocean targets used in SNO inter-calibration of MODIS and VIIRS, including clear-sky ocean, deep convective clouds (DCC), and liquid cloud targets in terms of their applicability to absolute intercomparison of visible imagers. The large SCIAMACHY and GOME-2 footprints and the lack of Hyperion cloudy scenes will impact the resulting SBAFs and necessitates the need for future CLARREO hyper-spectral reflectances to decrease SBAF uncertainties Preliminary results indicate that the SCIAMACHY and GOME-2 based SBAFs for the VIIRS I1 and M5 band pairs may differ by 1.5% for some ATO scene types. Because most of the modern GEOs visible band SRFs encompass the VIIRS I1 band SRF, these evaluations are critical to ensure that the MODIS, VIIRS, and GEO clouds and fluxes are consistent. SBAFs for Libya-4, Dome-C and other Earth invariant target will also be evaluated.

D. R. Doelling↗

Enhancements to the Open Access Spectral Band Adjustment Factor Online Calculation Tool for Visible Channels

With close to 40 years of satellite observations, from which, cloud, land-use, and aerosol parameters can be measured, inter-consistent calibrations are needed to normalize retrievals across satellite records. Various visible-sensor inter-calibration techniques have been developed that utilize radiometrically stable Earth targets, e.g., deep convective clouds and desert/polar ice pseudo-invariant calibration sites. Other equally effective, direct techniques for intercalibration between satellite imagers are simultaneous nadir overpass comparisons and ray-matched radiance pairs. Combining independent calibration results from such varied techniques yields robust calibration coefficients, and is a form of self-validation. One potential source of significant error when cross-calibrating satellite sensors, however, are the often small but substantial spectral discrepancies between comparable bands, which must be accounted for. As such, visible calibration methods rely on a Spectral Band Adjustment Factor (SBAF) to account for the spectral-response function- induced radiance differences between analogous imagers. The SBAF is unique to each calibration method as it is a function of the Earth-reflected spectra. In recent years, NASA Langley pioneered the use of SCIAMACHY-, GOME-2-, and Hyperion-retrieved Earth spectra to compute SBAFs. By carefully selecting hyperspectral footprints that best represent the conditions inherent to an inter-calibration technique, the uncertainty in the SBAF is greatly reduced. NASA Langley initially provided the Global Space-based Inter-calibration System processing and research centers with online SBAF tools, with which users select conditions to best match their calibration criteria. This article highlights expanded SBAF tool capabilities for visible wavelengths, with emphasis on the use of the spectral range filtering for the purpose of separating scene conditions for the channel that the SBAF is needed based on the reflectance values of other bands. In other words, spectral filtering will enable better scene-type selection for bands where scene determination is difficult without information from other channels, which should prove valuable to users in the calibration community.

Scarino, Benjamin↗

Comparative Analysis of Alternative Spectral Bands of CO2 and O2 for the Sensing of CO2 Mixing Ratios

We performed comparative studies to establish favorable spectral regions and measurement wavelength combinations in alternative bands of CO2 and O2, for the sensing of CO2 mixing ratios (XCO2) in missions such as ASCENDS. The analysis employed several simulation approaches including separate layers calculations based on pre-analyzed atmospheric data from the modern-era retrospective analysis for research and applications (MERRA), and the line-byline radiative transfer model (LBLRTM) to obtain achievable accuracy estimates as a function of altitude and for the total path over an annual span of variations in atmospheric parameters. Separate layer error estimates also allowed investigation of the uncertainties in the weighting functions at varying altitudes and atmospheric conditions. The parameters influencing the measurement accuracy were analyzed independently and included temperature sensitivity, water vapor interferences, selection of favorable weighting functions, excitations wavelength stabilities and other factors. The results were used to identify favorable spectral regions and combinations of on / off line wavelengths leading to reductions in interferences and the improved total accuracy.

Pliutau, Denis↗

Spectral Band Characterization for Hyperspectral Monitoring of Water Quality

A method for selecting the set of spectral characteristics that provides the smallest increase in prediction error is of interest to those using hyperspectral imaging (HSI) to monitor water quality. The spectral characteristics of interest to these applications are spectral bandwidth and location. Three water quality constituents of interest that are detectable via remote sensing are chlorophyll (CHL), total suspended solids (TSS), and colored dissolved organic matter (CDOM). Hyperspectral data provides a rich source of information regarding the content and composition of these materials, but often provides more data than an analyst can manage. This study addresses the spectral characteristics need for water quality monitoring for two reasons. First, determination of the greatest contribution of these spectral characteristics would greatly improve computational ease and efficiency. Second, understanding the spectral capabilities of different spectral resolutions and specific regions is an essential part of future system development and characterization. As new systems are developed and tested, water quality managers will be asked to determine sensor specifications that provide the most accurate and efficient water quality measurements. We address these issues using data from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and a set of models to predict constituent concentrations.

Vermillion, Stephanie C.↗

Spatial distribution and broad-band spectral characteristics of the diffuse X-ray background, 0.1 - 1.0 keV

Preliminary maps covering more than 85% of the sky are presented for three energy bands: 0.1 - 0.188 keV(B-band), 0.15 - 0.284 keV(C-band), and 0.45 - 1.0 keV(M-band). Preliminary analysis finds that: (1) there is no evidence requiring any substantial fraction of the soft X-ray background in this energy range to be extragalactic; (2) although large-scale anticorrelations between the lowest energy X-ray intensity and H(I) column density exist, most of the observed spatial variation cannot be explained by simple photoelectric absorption; and (3) although most of the B and C-band flux has a common origin most of the M-band flux does not come from the same material.

Mccammon, D.↗

Spatial distribution and broad-band spectral characteristics of the diffuse X-ray background, 0.1 - 1.0 keV

Preliminary maps covering more than 85 percent of the sky are presented for three energy bands: the B band, the C band, and the M band. The study was undertaken to find evidence that most of the diffuse X-ray background at energies less than 1 keV is local to the galaxy and that it is most probably due to thermal radiation from a low density plasma which fills a substantial fraction of interstellar space. A preliminary analysis of the data is provided including a report that most of the B and C band flux has a common origin, probably in a 10 to the 6th power K region surrounding the Sun, and that most of the M band flux does not originate from the same material.

Mccammon, D.↗

Dual and Multi-Spectral Band SLS Infrared Camera Systems

Based on the recent success of our strained-layer superlattice (SLS)-based infrared (IR) camera that performed Earth imaging from the International Space Station (ISS) in 2019 we have built, what we consider, to be the next generation multi-band SLS imaging system. The Compact Thermal Imager (CTI) was installed on the Robotic Refueling Mission 3 (RRM3) and attached to the exterior of the ISS. From this location we were able to capture 15 million images of a multitude of fires around the globe in 2019. This unexpected trove of data initiated quite a bit of scientific interest to further utilize this imaging capability but would include features to more precisely monitor terrestrial fires and other surface phenomena. To this end, we developed a technique to install specific bandpass filters directly onto the SLS detector hybrid assembly. Utilizing this technique we have built a CTI-2 camera system with two filters, 4 and 11µm, and have made a second detector assembly with six filter bands from 4-12µm. This second system will also be used to supplement Landsat remote imaging monitoring approximate land surface temperatures, monitor evapotranspiration, sea ice and glacier dynamics. The CTI-2 camera is based on a 1,024x1,024 (1kx1k) format SLS detector hybridized to a FLIR ISC0404 readout integrated circuit (ROIC). The six band SLS focal plane array is based on the 640x512 FLIR ISC 9803 ROIC. This camera system is based on the Landsat 8 and 9 Thermal IR Sensors (TIRS) instrument and one of its purposes is to perform ground truthing for the Landsat 8/9 data at higher spectral resolution. Both Landsat TIRS instruments are dual band thermal IR sensors centered on 11 and 12µm (each with about a 1µm bandpass). Both of our SLS systems utilize a Ricor K548 cryocooler. To streamline costs and development time we used commercial optics and both commercial and custom NASA electronic components. A primary feature of these camera systems is the incorporation of specific filters to collect fire data at ~3.9µm and thermal data at ~11µm. The CTI-2 instrument is designed for 37 m /pixel spatial resolution from 410km orbit (ISS orbit). In this paper, we will present the design and performance of the focal plane, optics, electronics and mechanical structure of the dual‑band CTI-2 and the focal plane performance of the six‑band focal plane.

Murzy Jhabvala↗

A Broad-band Spectral and Timing Study of the X-Ray Binary System Centaurus X-3

This dissertation describes a multi-mission investigation of the high mass X-ray binary pulsar Centaurus X-3. Cen X-3 was observed with the Broad Band X-Ray Telescope (BBXRT) in December 1990. This was the first high-resolution solid state X-ray spectrometer to cover the iron K fluorescence region. The Fe K emission feature was resolved into two components for the first time. A broad 6.7 keV feature was found to be a blend of lines from Fe XXI-Fe XXVI with energies ranging from 6.6 to 6.9 keV due to photoionization of the companion's stellar wind. A narrow line at 6.4 keV due to fluorescence of iron in relatively low ionization states was also found. The quasi-periodic oscillations (QPO) at about 40 mHz were used to estimate the surface magnetic field of Cen X-3 as approx. 2.6 x 10(exp 12) G and to predict that there should be a cyclotron scattering resonance absorption feature (CSRF) near 30 keV. In order to further resolve the iron line complex and to investigate the pulse-phase dependence of the iron line intensities, Cen X-3 was observed with the Advanced Satellite for Cosmology and Astrophysics (ASCA). Using ASCA's state-of-the-art non-dispersive X-ray spectrometers the 6.4 keV fluorescent iron line was found to be pulsing while the intensities of the 6.7 and 6.9 keV recombination lines do not vary with pulse phase. This confirms that the 6.4 keV line is due to reflection by relatively neutral matter close to the neutron star while the recombination lines originate in the extended stellar wind. The continuum spectrum was found to be modified by reflection from matter close to the neutron star. Observations with the EXOSAT GSPC were used to search for a CSRF. The EXOSAT spectra were consistent with the presence of a CSRF but an unambiguous detection was not possible because of a lack of sensitivity at energies higher than the cyclotron energy. Cen X-3 was then observed with the Rossi X-Ray Timing Explorer (RXTE) and evidence for a CSRF at 25.1 +/- 0.3 keV was found. This corresponds to a magnetic field of (2.16 +/- 0.03) X 10(exp 12) G and is consistent with the value obtained from the QPO analysis.

Audley, Michael Damian↗

Some observations about the components of transonic fan noise from narrow-band spectral analysis

Qualitative and quantitative spectral analyses are presented that give the broadband-noise, discrete-tone, and multiple-tone properties of the noise generated by a full-scale high-bypass single-stage axial-flow transonic fan (fan B, NASA Quiet Engine Program). The noise components were obtained from narrow-band spectra in conjunction with 1/3-octave-band spectra. Variations in the pressure levels of the noise components with fan speed, forward-quadrant azimuth angle, and frequency are presented and compared. The study shows that much of the apparent broadband noise on 1/3-octave-band plots consists of a complex system of shaft-order tones. The analyses also indicate the difficulties in determining or defining noise components, especially the broadband level under the discrete tones. The sources which may be associated with the noise components are discussed.

Saule, A. V.↗

Thematic mapper - An overview of spectral band registration

The Thematic Mapper (TM) is a high-resolution radiometer designed for earth resources classification and mapping. The TM employs multispectral scanning in a near polar orbit to sweep a 185-km swath. Data are obtained through a combination of spacecraft motion and the sweeping action of the scan mirror. These data are transmitted either directly to ground stations around the world or through a relay to the central data processing facility at White Sands, NM. Seven spectral passbands are employed, and applications include coastal water mapping, soil vegetation differentiation, biomass surveys, water body delineation, vegetation moisture measurement, plant heat stress management, and hydrothermal mapping. Attention is given to the scan mirror assembly, scan nonlinearities, the characterization and compensation of scan profiles, experimental performance, and a procedure for midscan correction.

Freudenstein, W. H.↗

Spectral band passes for a high precision satellite sounder

Atmospheric temperature soundings with significantly improved vertical resolution can be obtained from carefully chosen narrow band-pass measurements in the 4.3-micron band of CO2 by taking advantage of the variation of the absorption coefficients, and thereby the weighting functions, with pressure and temperature. A set of channels has been found in the 4.2-micron region that is capable of yielding about 2-km vertical resolution in the troposphere. The concept of a complete system is presented for obtaining high resolution retrievals of temperature and water vapor distribution, as well as surface and cloud top temperatures, even in the presence of broken clouds.

Kaplan, L. D.↗