Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral filter design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spectral and Wavefront Error Performance of WFIRST-AFTA Bandpass Filter Coating Prototypes

The Cycle 5 design baseline for the Wide-Field Infrared Survey Telescope Astrophysics Focused Telescope Assets (WFIRST/AFTA) instrument includes a single wide-field channel (WFC) instrument for both imaging and slit-less spectroscopy. The only routinely moving part during scientific observations for this wide-field channel is the element wheel (EW) assembly. This filter-wheel assembly will have 8 positions that will be populated with 6 bandpass filters, a blank position, and a Grism that will consist of a three-element assembly to disperse the full field with an undeviated central wavelength for galaxy redshift surveys. All filter elements in the EW assembly will be made out of fused silica substrates (110 mm diameter) that will have the appropriate bandpass coatings according to the filter designations (Z087, Y106, J129, H158, F184, W149 and Grism). This paper presents and discusses the performance (including spectral transmission and reflected/transmitted wavefront error measurements) of a subset of bandpass filter coating prototypes that are based on the WFC instrument filter compliment. The bandpass coating prototypes that are tested in this effort correspond to the Z087, W149, and Grism filter elements. These filter coatings have been procured from three different vendors to assess the most challenging aspects in terms of the in-band throughput, out of band rejection (including the cut-on and cutoff slopes), and the impact the wavefront error distortions of these filter coatings will have on the imaging performance of the wide-field channel in the WFIRST/AFTA observatory.

cryogenic temperatures↗

Image science team

A substantial technology base of solid state pushbroom sensors exists and is in the process of further evolution at both GSFC and JPL. Technologies being developed relate to short wave infrared (SWIR) detector arrays; HgCdTe hybrid detector arrays; InSb linear and area arrays; passive coolers; spectral beam splitters; the deposition of spectral filters on detector arrays; and the functional design of the shuttle/space platform imaging spectrometer (SIS) system. Spatial and spectral characteristics of field, aircraft and space multispectral sensors are summaried. The status, field of view, and resolution of foreign land observing systems are included.

Ando, K.↗

Angularly resolved spectral reconstruction of x rays via filter pack attenuation

We have designed a new filter pack array to measure angular variations in x-ray spectra during a single shot. The filter pack was composed of repeating identical columns of aluminum and copper filters of varying thicknesses. These columns were located at different positions to measure the spectrum at each corresponding angle. This array was utilized in an experiment to measure the energy evolution of betatron x rays in a laser wakefield accelerator by curving the wakefield with a transverse density gradient, streaking the x rays across the array in front of an x-ray charge-coupled device (CCD) camera. After subtracting the background and “flattening” the image to remove spatial nonuniformities, a critical energy was calculated for each position that produced the best agreement with the measured signal. There was a clear change in critical energy with angle, shedding light on the dynamics of the electrons that traveled through the accelerator. Furthermore, these angles correspond to distinct emission times, covering a timescale of tens of picoseconds. The filter pack was capable of recovering these angular details without the impact of errors introduced by shot-to-shot variability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Gas Property Measurements By Filtered Rayleigh Scattering: A Review

Filtered Rayleigh scattering (FRS) is a laser-based diagnostic technique used to nonintrusively quantify various thermodynamic properties of a light-scattering gas. The backbone of FRS is the molecular filtering of Rayleigh scattered light. This concept was initially introduced by the atmospheric LIDAR community before being adopted within the aerospace research field in the early 1990s. Since then, FRS has matured into a versatile quantitative diagnostic tool and has found use in a variety of flow regimes ranging from sub- to supersonic speeds in both reacting and nonreacting environments. This adoption can be attributed to the wealth of information that can be obtained via FRS, including the gas density, pressure, temperature, velocity, species composition, or, in some cases, several of these properties at once. This article reviews the current state of FRS methodology in recovering such gas properties. As knowledge of the fundamentals of Rayleigh scattering and spectral light filtering is crucial to the design of an FRS experiment, we begin by briefly reviewing these areas. Subsequently, we conduct a survey of experimental design strategies, assumptions, and data reduction methods used to measure different gas properties using FRS. We conclude the review with a short discussion on quantification of experimental uncertainty and future trends in FRS.

filtered Rayleigh scattering↗

Acousto-optic infrared spectral imager for Pluto fast flyby

Acousto-optic tunable filters (AOTF's) enable the design of compact, two-dimensional imaging spectrometers with high spectral and spatial resolution and with no moving parts. Tellurium dioxide AOTF's operate from about 400 nm to nearly 5 microns, and a single device will tune continuously over one octave by changing the RF acoustic frequency applied to the device. An infrared (1.2-2.5 micron) Acousto-Optic Imaging Spectrometer (AImS) was designed that closely conforms to the surface composition mapping objectives of the Pluto Fast Flyby. It features a 75-cm focal length telescope, infrared AOTF, and 256 x 256 NICMOS-3 focal plane array for acquiring narrowband images with a spectral resolving power (lambda/delta(lambda)) exceeding 250. We summarize the instrument design features and its expected performance at the Pluto-Charon encounter.

Glenar, D. A.↗

Optimizing structured surfaces for diffractive waveguides

We introduce universal diffractive waveguide designs that can match the performance of conventional dielectric waveguides and achieve various functionalities. Optimized using deep learning, diffractive waveguides can be cascaded to form any desired length and are comprised of transmissive diffractive surfaces that permit the propagation of desired modes with low loss and high mode purity. In addition to guiding the targeted modes through cascaded diffractive units, we also developed various waveguide components and introduced bent diffractive waveguides, rotating the direction of mode propagation, as well as spatial and spectral mode filtering and mode splitting diffractive waveguide designs, and mode-specific polarization control. This framework was experimentally validated in the terahertz spectrum to selectively pass certain spatial modes while rejecting others. Without the need for material dispersion engineering diffractive waveguides can be scaled to operate at different wavelengths, including visible and infrared spectrum, covering potential applications in, e.g., telecommunications, imaging, sensing and spectroscopy.

Applied optics↗

A compact spectroradiometer for solar simulator measurements

Compact spectral irradiance probe has been designed and built which uses wedge filter in conjunction with silicon cell and operational amplifier. Probe is used to monitor spectral energy distribution of solar simulators and other high intensity sources.

Seward, H. H.↗

The Simulation and Design of an On-Chip Superconducting Millimetre Filter-Bank Spectrometer

Abstract Superconducting on-chip filter banks provide a scalable, space saving solution to create imaging spectrometers at millimetre and submillimetre wavelengths. We present an easy to realise, lithographed superconducting filter design with a high tolerance to fabrication error. Using a capacitively coupled $$\lambda /2$$ λ / 2 microstrip resonator to define a narrow ( $$\lambda /\Delta \lambda = 300$$ λ / Δ λ = 300 ) spectral pass band, the filtered output of a given spectrometer channel directly connects to a lumped-element kinetic inductance detector. We show the tolerance analysis of our design, demonstrating $$<11\%$$ < 11 % change in filter quality factor to any one realistic fabrication error and a full filter-bank efficiency forecast to be 50% after accounting for fabrication errors and dielectric loss tangent.

Robson, G. (ORCID:0000000315279326)↗

Solc filter engineering

A Solc (1965) filter configuration is presented which is both tunable and spectrally variable, since it possesses an adjustable bandwidth, and which although less efficient than a Lyot filter is attractive because of its spectral versatility. The lossless design, using only an entrance and exit polarizer, improves throughput generally and especially in the IR, where polarizers are less convenient than dichroic sheet polarizers. Attention is given to the transmission profiles of Solc filters with different numbers of elements and split elements, as well as their mechanical design features.

Rosenberg, W. J.↗

High Efficiency Near Infrared Spectrometer for Zodiacal Light Spectral Study

We are developing a near infrared spectrometer for measuring solar absorption lines in the zodiacal light in the near infrared region. R. Reynolds at el. (2004, ApJ 61 2, 1206) demonstrated that observing single Fraunhofer line can be a powerful tool for extracting zodiacal light parameters based on their measurements of the profile of the Mg I l~neat 5 184 A. We are extending this technique to the near infrared with the primary goal of measuring the absolute intensity of the zodiacal light. This measurement will provide the crucial information needed to accurately subtract zodiacal emission from the DIRBE measurements to get a much higher quality measurement of the extragalactic IR background. The instrument design is based on a dual Fabry-Perot interferometer with a narrow band filter. Its double etalon design allows to achieve high spectral contrast to reject the bright out of band telluric OH emission. High spectral contrast is absolutely necessary to achieve detection limits needed to accurately measure the intensity of the absorption line. We present the design, estimated performance of the instrument with the expected results of the observing program.

Kutyrea, A. S.↗

Hemispherical-field-of-view, nonimaging narrow-band spectral filter

Two compound parabolic concentrators are used to create a 180-deg-field-of-view spectral filter. The collection optics are reflective and are designed to collimate the light through a multilayer interference filter and then to refocus it onto an optical detector. Assuming unit reflectance and no loss through the optical filter, this device operates at the thermodynamic collection limit.

Miles, R. B.↗

High Resolution Near Infrared Spectrometer to Study the Zodiacal Light Spectrum

We are developing a near infrared spectrometer for measuring solar absorption lines in the zodiacal light in the near infrared region. R. Reynolds at el. (2004, ApJ 612, 1206) demonstrated that observing single Fraunhofer line can be a powerful tool for extracting zodiacal light parameters based on their measurements of the profile of the Mg I line at 5184 A. We are extending this technique to the near infrared with the primary goal of measuring the absolute intensity of the zodiacal light. This measurement will provide the crucial information needed to accurately subtract zodiacal emission from the DIRBE measurements to get a much higher quality measurement of the extragalactic IR background. The instrument design is based on a dual Fabry-Perot interferometer with a narrow band filter. Its double etalon design allows to achieve high spectral contrast to reject the bright out of band telluric OH emission. High spectral contrast is absolutely necessary to achieve detection limits needed to accurately measure the intensity of the absorption line. We present the design, estimated performance of the instrument with the expected results of the observing program.

Kutyrev, Alexander↗

Reflective Filters Design for Self-Filtering Narrowband Ultraviolet Imaging Experiment Wide-Field Surveys (NUVIEWS) Project

We report the design of multilayer reflective filters for the self-filtering cameras of the NUVIEWS project. Wide angle self-filtering cameras were designed to image the C IV (154.9 nm) line emission, and H2 Lyman band fluorescence (centered at 161 nm) over a 20 deg x 30 deg field of view. A key element of the filter design includes the development of pi-multilayers optimized to provide maximum reflectance at 154.9 nm and 161 nm for the respective cameras without significant spectral sensitivity to the large cone angle of the incident radiation. We applied self-filtering concepts to design NUVIEWS telescope filters that are composed of three reflective mirrors and one folding mirror. The filters with narrowband widths of 6 and 8 rim at 154.9 and 161 nm, respectively, have net throughputs of more than 50 % with average blocking of out-of-band wavelengths better than 3 x 10(exp -4)%.

Park, Jung- Ho↗

Modal Filters for Infrared Interferometry

Modal filters in the approximately equal to 10-micrometer spectral range have been implemented as planar dielectric waveguides in infrared interferometric applications such as searching for Earth-like planets. When looking for a small, dim object ("Earth") in close proximity to a large, bright object ("Sun"), the interferometric technique uses beams from two telescopes combined with a 180 phase shift in order to cancel the light from a brighter object. The interferometer baseline can be adjusted so that, at the same time, the light from the dimmer object arrives at the combiner in phase. This light can be detected and its infrared (IR) optical spectra can be studied. The cancellation of light from the "Sun" to approximately equal to 10(exp 6) is required; this is not possible without special devices-modal filters- that equalize the wavefronts arriving from the two telescopes. Currently, modal filters in the approximately equal to 10-micrometer spectral range are implemented as single- mode fibers. Using semiconductor technology, single-mode waveguides for use as modal filters were fabricated. Two designs were implemented: one using an InGaAs waveguide layer matched to an InP substrate, and one using InAlAs matched to an InP substrate. Photon Design software was used to design the waveguides, with the main feature all designs being single-mode operation in the 10.5- to 17-micrometer spectral range. Preliminary results show that the filter's rejection ratio is 26 dB.

Ksendzov, Alexander↗

A robust pseudo-inverse spectral filter applied to the Earth Radiation Budget Experiment (ERBE) scanning channels

Computer simulations of a least squares estimator operating on the ERBE scanning channels are discussed. The estimator is designed to minimize the errors produced by nonideal spectral response to spectrally varying and uncertain radiant input. The three ERBE scanning channels cover a shortwave band a longwave band and a ""total'' band from which the pseudo inverse spectral filter estimates the radiance components in the shortwave band and a longwave band. The radiance estimator draws on instantaneous field of view (IFOV) scene type information supplied by another algorithm of the ERBE software, and on a priori probabilistic models of the responses of the scanning channels to the IFOV scene types for given Sun scene spacecraft geometry. It is found that the pseudoinverse spectral filter is stable, tolerant of errors in scene identification and in channel response modeling, and, in the absence of such errors, yields minimum variance and essentially unbiased radiance estimates.

Avis, L. M.↗

Acousto-optic filtering of lidar signals

The predominant part of the noise in lidar receivers is created by the background radiation; therefore, one of the most important elements of the receiving optics is a spectrally selecting filter placed in front of the photodetector. Interference filters are usually used to transmit a given wavelength. Specific properties of the interference filters, such as simple design, reliability, small size, and large aperture, combined with high transmission coefficient and narrow spectral band, make them the preferred spectral device in many cases. However, problems arise in applications such as the Differential Absorption Lidar (DIAL) technique, where fast tuning within a wide spectral region is necessary. Tunable acousto-optical filters (TAOF), used recently in astrophysical observations to suppress the background radiation, can be employed with success in lidar sounding. They are attractive due to the possibility for fast spectral scanning with a narrow transmission band. The TAOF's advantages are fully evident in DIAL lidars where one must simultaneously receive signals at two laser frequencies.

Kolarov, G.↗

Solar CIV Vacuum-Ultraviolet Fabry-Perot Interferometers

Aims: A tunable, high spectral resolution, high effective finesse, vacuum ultraviolet (VUV) Fabry-Perot interferometer (PPI) is designed for obtaining narrow-passband images, magnetograms, and Dopplergrams of the transition region emission line of CIV (155 nm). Methods: The integral part of the CIV narrow passband filter package (with a 2-10 pm FWHM) consists of a multiple etalon system composed of a tunable interferometer that provides high-spectral resolution and a static low-spectral resolution interferometer that allows a large effective free spectral range. The prefilter for the interferometers is provided by a set of four mirrors with dielectric high-reflective coatings. A tunable interferometer, a VUV piezoelectric-control etalon, has undergone testing using the surrogate F2 eximer laser line at 157 nm for the CIV line. We present the results of the tests with a description of the overall concept for a complete narrow-band CIV spectral filter. The static interferometer of the filter is envisioned as being hudt using a set of fixed MgF2 plates. The four-mirror prefilter is designed to have dielectric multilayer n-stacks employing the design concept used in the Ultraviolet Imager of NASA's Polar Spacecraft. A dual etalon system allows the effective free spectral range to be commensurate with the prefilter profile. With an additional etalon, a triple etalon system would allow a spectrographic resolution of 2 pm. The basic strategy has been to combine the expertise of spaceflight etalon manufacturing with VUV coating technology to build a VUV FPI which combines the best attributes of imagers and spectrographs into a single compact instrument. Results. Spectro-polarimetry observations of the transition region CIV emission can be performed to increase the understanding of the magnetic forces, mass motion, evolution, and energy release within the solar atmosphere at the base of the corona where most of the magnetic field is approximately force-free. The 2D imaging of the full vector magnetic field at the height of maximum magnetic influence (minimum plasma beta) can be accomplished, albeit difficult, by measuring the Zeeman splitting of the CIV resonance pair. Designs of multiple VUV FPIs can be developed for integration into future orbiting solar observatories to obtain rapid cadence, spectral imaging of the transition region.

Gary, G. Allen↗

Photo sensor array technology development

The development of an improved capability photo sensor array imager for use in a Viking '75 type facsimile camera is presented. This imager consists of silicon photodiodes and lead sulfide detectors to cover a spectral range from 0.4 to 2.7 microns. An optical design specifying filter configurations and convergence angles is described. Three electronics design approaches: AC-chopped light, DC-dual detector, and DC-single detector, are investigated. Experimental and calculated results are compared whenever possible using breadboard testing and tolerance analysis techniques. Results show that any design used must be forgiving of the relative instability of lead sulfide detectors. A final design using lead sulfide detectors and associated electronics is implemented by fabrication of a hybrid prototype device. Test results of this device show a good agreement with calculated values.

Rossman, M. W.↗