Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral filter design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Chromatic effects on the PSF and shear measurement for the Roman Space Telescope High-Latitude Wide Area Survey

Weak gravitational lensing (WL) is a key cosmological probe that requires precise measurement of galaxy images to infer shape distortions, or shear, and constrain cosmology. Accurate estimation of the point spread function (PSF) is crucial for shear measurement, but the wavelength dependence of the PSF introduces chromatic biases that can systematically impact shear inference. We focus on biases arising from spectral energy distribution (SED) differences between stars, used for PSF modelling, and galaxies, used for shear measurement. We investigate these effects in Roman’s four design reference mission WL bands (Y106, J129, H158, F184) and wide filter (W146). Using Roman-like image simulations, we quantify the induced shear biases and compare them to requirements on those biases. Multiplicative biases over all galaxies hover around ~0.2 per cent in the WL bands and 2 per cent in the wide filter, exceeding the mission requirement of |m| < 0.032 per cent and relaxed requirement of |m| < 0.1 per cent⁠. In individual redshift bins, biases can reach 0.4–0.9 per cent for the WL bands and 3–6 per cent for the wide filter. Additive biases remain acceptable in the WL bands but exceed systematic limits in the wide filter. We develop and test PSF-level corrections, showing that a first-order correction reduces biases within survey requirements for the WL bands; however, higher-order terms are necessary for the wide filter. Our results highlight the necessity of chromatic corrections for precision WL with Roman and provide a framework for mitigating these biases. Finally, we compare analytical colour-based corrections to self-organizing maps and find that both methods effectively reduce biases.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.

47 OTHER INSTRUMENTATION↗

Spectral Element Applications in Complex Nuclear Reactor Geometries: Tet-to-Hex Meshing

The spectral element code Nek5000 is an open-source, higher-order computational fluid dynamics code developed at Argonne National Laboratory. It is designed to solve incompressible Navier-Stokes equations, but it also has a low-Mach-number approximation feature available. Large eddy simulation is approached by explicit filtering of the velocity field (and other fields) to mimic the effect of dissipation due to the unresolved scale. The computational domain is decomposed into second-order hexahedral elements that conform to the boundaries. However, generating a high-quality pure-hexahedral mesh can be challenging for some problems. For simple geometries, traditional blocking methods can be used to decompose the domain into smaller blocks to generate a so-called structural mesh. A structural mesh can maintain good orthogonality but can have a highly skewed mesh to conform to the geometry, as well as unnecessary refinement in the far field. Moreover, for geometries with relative complexity, blocking the geometry becomes impossible. To address these issues, we adopted a let-to-hex strategy to generate a pure hexahedral mesh for Nek5000. First, we generate a pure tetrahedral mesh for the geometry; then we divide one tetrahedral element into four hexahedral elements. A pure tetrahedral mesh could be easily generated for complex geometries by using many current meshing codes. In this paper, we use the commercial codes ANSYS meshing and ANSYSICEM to generate the pure tetrahedral mesh and then convert it to a pure hexahedral mesh. Boundary layers are extruded in ANSYSICEM to maintain near-wall resolution.

ANSYS ICEM↗

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

microstrip resonators↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co-designing Spectral Transformation Oracles with Hybrid Oscillator-Qubit Quantum Processors: From Algorithms to Compilation

We co-design a family of quantum eigenvalue transformation oracles that can be efficiently implemented on hybrid discrete- or continuous-variable (qubit or qumode) hardware. To illustrate the oracle’s representation-theoretic power and near-term experimental accessibility, we encode a Gaussian imaginary time-evolution spectral filter. As a result, we define a continuous linear combination of unitaries block encoding. Due to the ancillary qumode’s infinite-dimensional nature, continuous-variable qumodes constitute a powerful compilation tool for encoding continuous spectral functions without discretization errors while minimizing resource requirements. We then focus on the ubiquitous task of preparing eigenstates in quantum spin models. For completeness, we provide an end-to-end compilation which expresses high-level oracles in terms of an experimentally realizable instruction set architecture in both 1D and 2D. Finally, we examine the leading-order effects of physical errors and highlight open research directions. Our algorithms scale linearly with the spatial extent of the target system and are applicable to both near-term and large-scale quantum processors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A versatile high-average-power ultrafast infrared driver tailored for high-harmonic generation and vibrational spectroscopy

We report on an ultrafast infrared optical parametric chirped-pulse amplifier (OPCPA), pumped by a 200-W thin-disk Yb-based regenerative amplifier at a repetition rate of 100 kHz. The OPCPA is tunable in the spectral range 1.4–3.9 μm, generating up to 23 W of < 100-fs signal and 13 W of < 200-fs idler pulses for infrared spectroscopy, with additional spectral filtering capabilities for Raman spectroscopy. The OPCPA can also yield 19 W of 49-fs 1.75- μm signal or 5 W of 62-fs 2.8- μm idler pulses with active carrier-to-envelope-phase (CEP) stabilisation for high-harmonic generation (HHG). We illustrate the versatility of the laser design, catering to various experimental requirements for probing ultrafast science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

The Spectroscopic Classification of Astronomical Transients (SCAT) Survey: Overview, Pipeline Description, Initial Results, and Future Plans

Here, we present the Spectroscopic Classification of Astronomical Transients (SCAT) survey, which is dedicated to spectrophotometric observations of transient objects such as supernovae and tidal disruption events. SCAT uses the SuperNova Integral-Field Spectrograph (SNIFS) on the University of Hawai’i 2.2 m (UH2.2m) telescope. SNIFS was designed specifically for accurate transient spectrophotometry, including absolute flux calibration and host-galaxy removal. We describe the data reduction and calibration pipeline including spectral extraction, telluric correction, atmospheric characterization, nightly photometricity, and spectrophotometric precision. We achieve ≲5% spectrophotometry across the full optical wavelength range (3500–9000 Å) under photometric conditions. The inclusion of photometry from the SNIFS multi-filter mosaic imager allows for decent spectrophotometric calibration (10%–20%) even under unfavorable weather/atmospheric conditions. SCAT obtained ≈640 spectra of transients over the first 3 yr of operations, including supernovae of all types, active galactic nuclei, cataclysmic variables, and rare transients such as superluminous supernovae and tidal disruption events. These observations will provide the community with benchmark spectrophotometry to constrain the next generation of hydrodynamic and radiative transfer models.

79 ASTRONOMY AND ASTROPHYSICS↗

Blue Canyon Dome Emplacement Artifacts

The Blue Canyon Dome (BCD) experiments are a series of intermediate scale subsurface chemical explosions designed to explore the geophysical relationship between scaled yields and formation damage. Phase 2 of this experiment involved explosions designed to evaluate the effect of damage, demonstrating the effect of geologic features and previous damage on the near field seismic signatures, not just in amplitude, but also in spectral content. Based on the emplacement effect on the seismic signature, the moment-based yield estimates showed error between 10s-1000s of percent. This report details an alternative approach to emplacement-based filtering techniques of the seismic signatures to improve yield estimates for explosions in damaged rock. The results will be used to develop an improved inverse yield model that leverages the information in the seismic signature for each source based on emplacement type.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Challenges and Solutions for Fast Neutron Irradiation of Bulk Material Specimens

Reactor developers continue to recognize opportunities for further enhancing fast spectrum reactor designs with advanced core materials, but all the material test reactors currently available to the United States are thermal spectrum designs. Fortunately, the Advanced Test Reactor and High Flux Isotope Reactor are versatile high flux facilities where spectral modification strategies can be used to reduce undesirable thermal neutron capture transmutation damage and augment fast flux delivered to specimens. New opportunities to leverage high flux regions and specially designed fast flux boosting experiment configurations can be used to achieve meaningful fast fluences on large specimens in ATR. New optimization potentials can be employed to achieve even higher fluences, albeit for smaller specimens, using thermal neutron filters in HFIR test positions. These capabilities, while not true fast reactors, can provide highly relevant environments for researchers needing to study the effects of fast neutron damage in bulk material specimens.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Atmospheric Modeling and Denoising for Millimeter-Wave Line Intensity Mapping

Line-intensity mapping (LIM) offers a promising approach to mapping large-scale cosmic structure, and the greatest obstacle for ground-based observations at millimeter wavelengths is foreground contamination from atmospheric emission. In this work, we present a simulation and denoising framework designed to isolate and subtract atmospheric fluctuations from LIM data, modeled after the instrument parameters of the South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM). We generate mock observations spanning 125-175 GHz containing cosmic signals, precipitable water vapor screens, ice crystal fluctuations, and photon noise. We then implement a spatial-spectral atmospheric removal pipeline combining per-pixel linear template regression with a two-dimensional Fourier-domain filter. The framework is evaluated under simulated conditions in the South Pole and the Atacama Desert across three key metrics: cosmic signal preservation, foreground subtraction efficiency, and instrument noise injection. Our pipeline achieves atmospheric suppression at large spatial scales, and these results establish a physically grounded foundation for atmosphere removal in ground-based LIM data collection.

Saye, Laney [UC, Berkeley (main)] (ORCID:000900078↗

Atmospheric Modeling and Denoising for Millimeter-Wave Line Intensity Mapping

Line-intensity mapping (LIM) offers a promising approach to mapping large-scale cosmic structure, and the greatest obstacle for ground-based observations at millimeter wavelengths is foreground contamination from atmospheric emission. In this work, we present a simulation and denoising framework designed to isolate and subtract atmospheric fluctuations from LIM data, modeled after the instrument parameters of the South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM). We generate mock observations spanning 125-175 GHz containing cosmic signals, precipitable water vapor screens, ice crystal fluctuations, and photon noise. We then implement a spatial-spectral atmospheric removal pipeline combining per-pixel linear template regression with a two-dimensional Fourier-domain filter. The framework is evaluated under simulated conditions in the South Pole and the Atacama Desert across three key metrics: cosmic signal preservation, foreground subtraction efficiency, and instrument noise injection. Our pipeline achieves atmospheric suppression at large spatial scales, and these results establish a physically grounded foundation for atmosphere removal in ground-based LIM data collection.

Saye, L. K. [UC, Berkeley (main)] (ORCID:000900078↗

Phase-shifted Bragg gratings in a foundry silicon nitride platform

Bragg gratings are key optical elements for applications in communications, sensing, and lasers. Phase-shifted Bragg gratings are a special case where the simple periodic structure is altered to allow a narrow spectral passband within the optical bandgap. Here, we demonstrate phase-shifted silicon nitride gratings fabricated using 193 nm deep ultraviolet lithography (DUV) on the AIM Photonics 300 mm silicon photonics foundry line. We measure the grating properties and verify the results with a transfer-matrix method (TMM) model. The standard grating expressions for extracting the coupling coefficient κ and bandwidth do not apply and are updated to account for the phase shift. These results inform future designs for on-chip grating filters and distributed feedback (DFB) lasers.

Husko, Chad (ORCID:0000000271252518)↗