Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral mismatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Interstellar extinction variations in the Large Magellanic Cloud

The properties of ultraviolet extinction in the LMC are reexamined using some of the existing LMC data from the International Ultraviolet Explorer (IUE) satellite and a large number of new observations obtained during the IUE Sixth Episode. The main goal is to determine if the LMC extinction properties are regionally modulated and, if so, to examine the type and range of the variations. Among the new IUE observations presented is a large grid of unreddened LMC flux standards, which will eliminate spectral mismatch effects as complications in the extinction analysis. Eight new reddened stars were observed. The properties of the program stars are summarized; the method for producing the extinction curves (including the criteria for pairing reddened and unreddened stars) is discussed; and the curves themselves are presented and discussed.

Fitzpatrick, E. L.↗

Fiber Optical Solar Simulator

A new solar simulator is described whose output closely matches a desired solar spectrum for testing photovoltaic cells. The accurate simulation of the spectrum is attained by combining three light beams, each tailored to have suitable spectral content. The three light beams, derived from two sources, are filtered and 'mixed' by means of a trifurcated, randomized fiber cable so that when superimposed they add up to the desired solar spectrum. The fiber optic solar simulator (FOSS) simplifies solar cell testing by greatly reducing measurement time, obviating need for spectral mismatch corrections, and improving the accuracy of measurement. Other applications of FOSS are also described.

Sopori, Bhushan L.↗

Transmittance Measurement of a Heliostat Facility used in the Preflight Radiometric Calibration of Earth-Observing Sensors

Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.

Czapla-Myers, J.↗

Spectral Effects in Albedo and Rearside Irradiance Measurment for Bifacial Performance Estimation: Preprint

Albedo data are essential for accurate prediction of bifacial PV module performance. However, spectral response mismatch between PV modules and irradiance sensors used in albedometers can limit the accuracy of performance predictions. In order to provide quantitative assessment of this effect, we investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystallinesilicon PV reference cells in comparison to a representative crystalline-silicon bifacial PV module for nine different representative ground surface materials. Calculations are performed using simulated solar spectra together with catalogued spectral reflectivity data distributed with the SMARTS simulation software. For the specific materials considered, the results show that albedo measurement using thermopile pyranometers could over or under-estimate the ground-reflected radiation usable by a bifacial PV module by up to 10%, versus only approximately 4% total range of variation for a PV reference cell.

Albedo↗

Elastomeric reflection suppressor

Various embodiments of the present technology generally relate to reflection suppressors. More specifically, some embodiments use elastomeric materials doped with optical absorbers for temporary suppression of Fresnel reflections for multiple substrates spanning wide spectral and angular bandwidth. The refractive index of the elastomer can be tuned to match a substrate and thereby minimize reflection. Some embodiments can use the addition of different absorptive dopants to allow for either broadband or wavelength-selective reflection suppression. As performance is limited only by index mismatch, both spectral and angular performance significantly exceed that of anti-reflection coatings. After use, these light traps may be removed and reused without damaging the substrate. These films have uses in spectroscopic ellipsometry, holography, and lithography.

Miller, David↗

Distribution of the Spectral Response of Cells in Silicon Modules - Mechanisms and Implications

Measurements of the spectral response of cells in a PV module can provide important insight into the physics of the device and are also needed for the accurate calibration of the performance of these devices using solar simulators. While techniques for measuring the spectral response of PV cells are well established, measurement of the spectral response of all cells in a module is not straightforward since in this case one has electrical access to a string of cells and not to cells individually. Here we present a new approach for testing the spectral response of individual cells in silicon modules that allows for the fast mapping of the response at different locations of the module. We show that in some cases the spectral response of different cells in a module can vary considerably and propose an underlying mechanism for this variation. We also discuss the implications of this observation for the uncertainty of the spectral correction and of the I SC calibration using a solar simulator.

modules↗

Frequency Domain Reflectometry (FDR) Simulation Techniques for Digital Twin Representation of an Electrical Cable

Simulation of cable system response to frequency domain reflectometry (FDR) tests can be instrumental to understanding these tests and the nature and influence of various cable anomalies on test signatures. Reflectometry simulations are based upon a finite element representation of cable conductors and insulation to produce an S-parameter at each evaluated frequency. The aggregate collection of cable model S-parameters can simulate the influence on a test signal injected into a physical cable. Such an approach was undertaken in this work to produce a digital twin simulation of a low-voltage electrical cable. The electrical cable digital twin examined the influence of test simulation parameters and the relative influence of cable anomalies, including thermal aging, water or moisture exposure, water or moisture ingress, and other anomalies. The digital twin in this work included modeling of the conductors, insulation, jacket, and surrounding environment (air, water, etc.). The digital twin could be expanded to include cable bends, junctions and splices, branch or T systems, and termination impedances of motors or instruments. Observations and conclusions of this work include: 1. Fully 3D digital twin simulation of an electrical cable using an FDR approach is possible. However, there are tradeoffs between simulation fidelity and solution time, which must be balanced to ensure the simulation solves in an adequate amount of time (e.g., less than 20 minutes). Simulation parameters to balance include frequency bandwidth, number of frequencies, mesh density, connection impedance, and permittivity tolerance. 2. The digital twin simulation can explain FDR sensitivity to various cable anomalies, including entry and exit from an oven or water bath. 3. The digital twin simulation FDR response attenuates with distance along the cable and is further affected by the frequency bandwidth, which is similar to that observed with physical measurements. 4. The resolution of the digital twin FDR peaks increased with increasing bandwidth and with increasing number of frequencies, again similar to physical measurements. 5. The presence of multiple anomalies in the digital twin does not substantially attenuate the FDR response to anomalies located beyond the first encountered anomaly and impedance mismatch. 6. Spectral variation of the permittivity did not have a significant effect on the FDR response compared to a fixed nominal value. 7. Extension of the digital twin to 1000 ft still allowed for detection of distal anomalies near the far end of the electrical cable from the instrument connection point. 8. The ARENA test bed facilitates efficient NDE evaluations of well understood cable anomalies with various NDE methods without risking actual plant damage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cross-Calibration of the Oceansat-2 Ocean Colour Monitor (OCM) with Terra and Aqua MODIS

The Ocean Colour Monitor (OCM) sensor on-board the Oceansat-2 spacecraft has been operational since its launch in September, 2009. The Oceansat 2 OCM primary design goal is to provide continuity to Oceansat-1 OCM to obtain information regarding various ocean-colour variables. OCM acquires Earth scene measurements in eight multi-spectral bands in the range from 402 to 885 nm. The MODIS sensor on the Terra and Aqua spacecraft has been successfully operating for over a decade collecting measurements of the earth's land, ocean surface and atmosphere. The MODIS spectral bands, designed for land and ocean applications, cover the spectral range from 412 to 869 nm. This study focuses on comparing the radiometric calibration stability of OCM using near-simultaneous TOA measurements with Terra and Aqua MODIS acquired over the Libya 4 target. Same-day scene-pairs from all three sensors (OCM, Terra and Aqua MODIS) between August, 2014 and September, 2015 were chosen for this analysis. On a given day, the OCM overpass is approximately an hour after the Terra overpass and an hour before the Aqua overpass. Due to the orbital differences between Terra and Aqua, MODIS images the Libya 4 site at different scan-angles on a given day. Some of the high-gain ocean bands for MODIS tend to saturate while viewing the bright Libya 4 target, but bands 8-10 (412 nm - 486 nm) provide an unsaturated response and are used for comparison with the spectrally similar OCM bands. All the standard corrections such as bidirectional reflectance factor (BRDF), relative spectral response mismatch, and impact for atmospheric water-vapor are applied to obtain the reflectance differences between OCM and the two MODIS instruments. Furthermore, OCM is used as a transfer radiometer to obtain the calibration differences between Terra and Aqua MODIS reflective solar bands.

Angal, Amit↗

Comparison of the MODIS and VIIRS Thermal Emissive Band Radiometric Calibration

Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) are major instruments for Earth science observations.Nearly 40 MODIS scientific products and a wide range of VIIRS environmental data records are produced using their global observations. The consistency of the MODIS and VIIRS calibrated data is important for the study of Earth science. This article assesses the calibration consistency of the Aqua MODIS and VIIRS thermal emissive band (TEB) data. To remove the impact of the mismatched relative spectral response (RSR) on the comparisons, the simultaneous nadir observation data from the cross-track infrared sounder (CrIS) and the infrared atmospheric sounding interferometer (IASI) are used as references in two different methods to independently verify the consistency. The comparisons of the MODIS and VIIRS TEB calibrated data show that the brightness temperature (BT) differences for comparable bands between MODIS and VIIRS are in general within 0.2 K for BT larger than 230 K. The differences of all comparable MODIS and VIIRS TEBs are consistent over time. MODIS measurements agree better with N20 VIIRS than with Suomi National Polar-orbiting Partnership (S-NPP) VIIRS. The S-NPP VIIRS measurements are higher than N20 VIIRS, within 0.1 Kfor long-wave infrared (LWIR) bands and 0.3 K for band M13.

Calibration↗

Developing a Spectral Correlation based Method for mitigating Angular Mismatch Effects in Intercalibration Using a Benchmark Hyperspectral Sensor

The CLARREO Pathfinder (CPF) mission will implement a state-of-the-art intercalibration method for transferring CPF’s in-orbit Système Internationale (SI)-traceable reference to the shortwave channel of the Clouds and the Earth’s Radiance Energy System (CERES) and the reflective solar bands of the Visible Infrared Imaging Radiometer Suite (VIIRS) aboard the NOAA-20 satellite platform with a targeted intercalibration methodology uncertainty of 0.3% (k=1). In order to achieve such a high intercalibration accuracy, the CPF intercalibration measurements to be scheduled need to closely match those from CERES and VIIRS in time, space, angles, and wavelength. Despite’s CPF’s two-axis pointing capability to match its boresight line of sight to that of a target sensor, there will be finite residual differences in angular samplings of the two instruments. The potential angular mismatch between CPF and the target sensors can introduce systematic errors in the intercalibration results, and therefore needs to be corrected using a rigorously designed algorithm. The CPF intercalibration team has been developing a correction method for mitigating the impact of these angular anisotropic effects in the CPF-VIIRS and CPF-CERES intercalibration. The method explores the spectral correlation relationship between the reflected solar radiances from the same surface target that would be measured by CPF at two adjacent angles. Our studies have shown that the spectral information based on CPF measurements can be used to accurately predict the spectral radiance or reflectance difference due to a given mismatch in the viewing and solar geometry. The hyper-spectral information can also be used to provide scene stratification without using any auxiliary data, which is critical to reduce the angular correction uncertainty. The angular correction relationship can be well established using simulated CPF-like top-of-atmosphere spectral radiances observed at all sorts of viewing geometry and solar angles and for different scenes. Intensive radiative transfer simulations have been completed using a state-of-art radiative transfer model developed by the CPF team members. The implementation of the algorithm on high-fidelity event simulation data and the characterization for the angular adjustment uncertainty will be presented.

Wan Wu↗

Assessing the Calibration Differences in the Reflective Solar Bands of Terra MODIS and Landsat-7 Enhanced Thematic Mapper Plus

Long-term data records obtained from Earth observing sensors depend not only onthe calibration accuracy of individual sensors but also on the consistency across instruments andplatforms. Hence, sensor calibration intercomparison plays a vital role for a better understandingof various science products. The Moderate Resolution Imaging Spectroradiometer (MODIS)and enhanced thematic mapper plus (ETM+) on the Terra and Landsat 7 platforms have operatedsuccessfully since their launch, collecting measurements in the reflective solar and infrared partsof the spectrum. Terra MODIS has employed a reflectance-based calibration since beginning itsmission. In the case of ETM+, a radiance-based calibration was employed until recent years,when a reflectance-based calibration was introduced. Being in the AM constellation with lessthan 30 min difference in overpass times, near-simultaneous Earth scene measurements can beeffectively used to assess the calibration differences between the spectrally matching bands ofthese two instruments. The pseudoinvariant calibration sites (PICS) in the North African desertare widely used for on-orbit calibration and validation of satellite sensors. Four PICS from thisregion have been employed to assess the multitemporal reflectance differences. Correction forbidirectional reflectance, spectral response function mismatch, and impacts of atmosphericwater-vapor have been incorporated to provide an assessment of the long-term stability ofeach spectral band and reflectance differences amongst them. Results indicate that the spectralbands of both instruments show a long-term stability to within 2% from 2000 to 2017. Thetop-of-atmosphere reflectances between the two instruments postcorrection agree to within 4%.Also included in this paper is a detailed discussion of various parameters contributing to theuncertainties of this cross-calibration. The techniques presented in this paper can be furtherextended to perform similar intercomparison between Landsat 8 Operational Land Imager, AquaMODIS, and Suomi-NPP VIIRS.

Angal, Amit↗

Atomistic insights into the heat conductance across the interfaces between erythritol and different metals: A non-equilibrium molecular dynamics study

The heat conductance across the interface between a phase change material (PCM) and the metal shell is important for thermal design of latent heat storage systems. Non-equilibrium molecular dynamics simulations were carried out in this work to unravel, at the atomistic level, the interfacial heat conductance mechanisms between erythritol (the most promising medium-temperature polyol PCM) and two different metals (i.e., copper and aluminum). The interfacial contact ratio was introduced as a parameter to represent different contact conditions at the interfaces, for example, different surface roughness levels of the metals. It was found that with the increase of interfacial contact ratio, the temperature difference between the erythritol/metal interfaces decreases, whereas the interfacial heat transfer coefficient increases gradually. At the perfect contact condition, i.e., the interfacial contact ratio reaches 100%, the interfacial heat transfer coefficients across the erythritol/Cu and erythritol/Al interfaces were predicted to be 398 ± 26 MW/m 2 K and 544 ± 11 MW/m 2 K, respectively. The interfacial heat conductance of erythritol/Al is better than that of erythritol/Cu. The mismatch of atomic spectral density across the interfaces between erythritol and the two metals was analyzed and distinguished. These results could guide the selection of packaging materials and the thermal design of erythritol-based latent heat storage systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fermi-LAT View on Three Ultra-high-energy 1LHAASO Sources in the 52° < l < 55° Region

Using more than 17 yr of Fermi-LAT data, we performed a detailed investigation of the complex 52° < l < 55° region, which encompasses the three ultra-high-energy sources 1LHAASO J1928+1746u, 1LHAASO J1928+1813u, and 1LHAASO J1929+1846u. This region hosts multiple supernova remnants (SNRs), pulsars, GeV and TeV sources. Our analysis resolves the GeV emission into three pointlike sources (J1925+1729P, J1930+1851P, and J1932+1916P) and two extended sources (J1929+1732E and J1930+1826E), and improves significantly on the description based on the 4FGL-DR4 catalog. Source J1932+1916P is identified as the known gamma-ray pulsar PSR J1932+1916, while J1925+1729P may be a new gamma-ray pulsar candidate distinct from the known gamma-ray pulsar PSR J1925+1720. This warrants future investigation and a search for pulsations. Source J1930+1851P coincides with the TeV source PWN/SNR G54.1+0.3, and its GeV−TeV spectrum is consistent with both leptonic and hadronic interpretations, although a leptonic origin in relation to the known pulsar wind nebula (PWN) is more likely. The GeV−TeV spectrum of J1929+1732E is consistent with a hybrid lepto-hadronic scenario in which the TeV emission traces the PWN powered by the pulsar PSR J1928+1746, while the GeV emission may result from interactions between particles escaped from the parent SNR and illuminating the gas environment. Similarly, J1930+1826E is likely connected to PWN/SNR G54.1+0.3 under a hadronic scenario involving escaped particles in their early propagation stage. Owing to spectral and/or morphological mismatches, the connection of these five GeV sources to the three LHAASO sources is not clear. This warrants deeper observations with HAWC and LHAASO, and a dedicated study of the modeling of the Galactic diffuse emission. Future CTAO observations with higher angular resolution are expected to deliver crucial information for the study of this region.

Liu, Linjie [Chinese Academy of Sciences (CAS), Ku↗

DNA CTG triplet repeats involved in dynamic mutations of neurologically related gene sequences form stable duplexes

DNA triplet repeats, 5'-d(CTG)n and 5'-d(CAG)n, are present in genes which have been implicated in several neurodegenerative disorders. To investigate possible stable structures formed by these repeating sequences, we have examined d(CTG)n, d(CAG)n and d(CTG).d(CAG)n (n = 2 and 3) using NMR and UV optical spectroscopy. These studies reveal that single stranded (CTG)n (n > 2) forms stable, antiparallel helical duplexes, while the single stranded (CAG)n requires at least three repeating units to form a duplex. NMR and UV melting experiments show that the Tm increases in the order of [(CAG)3]2 < [(CTG)3]2 << (CAG)3.(CTG)3. The (CTG)3 duplex is stable and exhibits similar NMR spectra in solutions containing 0.1-4 M NaCl and at a pH range from 4.6 to 8.8. The (CTG)3 duplex, which contains multiple-T.T mismatches, displays many NMR spectral characteristics similar to those of B-form DNA. However, unique NOE and 1H-31P coupling patterns associated with the repetitive T.T mismatches in the CTG repeats are discerned. These results, in conjunction with recent in vitro studies suggest that longer CTG repeats may form hairpin structures, which can potentially cause interruption in replication, leading to dynamic expansion or deletion of triplet repeats.

NASA Discipline Exobiology↗

GEO-LEO Reflective Band Inter-Comparison with BRDF and Atmospheric Scattering Corrections

The inter-comparison of the reflective solar bands (RSB) between the instruments onboard a geostationary orbit satellite and a low Earth orbit satellite is very helpful in assessing their calibration consistency. Himawari-8 was launched 7 October 2014 and GOES-R was launched on 19 November 2016. Unlike previous GOES instruments, the Advanced Himawari Imager (AHI) on Himawari-8 and the Advanced Baseline Imager (ABI) on GOES-R have onboard calibrators for the RSB. Independent assessment of calibration is nonetheless important to enhance their product quality. MODIS (Moderate Resolution Imaging Spectroradiometer) and VIIRS (Visible Infrared Imaging Radiometer Suite) can provide good references for sensor calibration. In this work, the inter-comparison between AHI and VIIRS is performed over a pseudo-invariant target. The use of stable and uniform calibration sites provides comparison with accurate adjustment for band spectral difference, reduction of impact from pixel mismatching, and consistency of BRDF (Bidirectional Reflectance Distribution Function) and atmospheric correction. The site used is the Strzelecki Desert in Australia. Due to the difference in solar and view angles, two corrections must be applied in order to compare the measurements. The first is the atmospheric scattering correction applied to the top of atmosphere reflectance measurements. The second correction is applied to correct the BRDF effect. The atmospheric correction is performed using a vector version of the Second Simulation of a Satellite Signal in the Solar Spectrum (6SV) model and the BRDF correction is performed using a semi-empirical model. Our results show that AHI band 1 (0.47 microns) has a good agreement with VIIRS band M3 within 0.15 percent. AHI band 5 (1.61 microns) shows the largest difference (5.09 percent) with VIIRS band M10, while AHI band 5 shows the least difference (1.87 percent) in comparison with VIIRS band I3. The methods developed in this work can also be directly applied to assess GOES-16/ABI (Geostationary Operational Environment Satellite16 / Advanced Baseline Imager) calibration consistency, a topic we will address in the future.

The inter-comparison of the reflective solar bands↗

The Spectral Information Based Angular Correction Methodology for Satellite Intercalibration Applications

Satellite inter-calibration often requires collocated observations with minimized discrepancies in sun-view angles, observation times, and sensor characteristics. The collocation criteria directly impact achievable inter-calibration accuracy. Addressing potential angular mismatches in inter-calibration samples is critical but not as fully recognized and addressed as spatial-temporal mismatches in many studies. To achieve high-accuracy corrections for errors due to mismatched sun-view geometry angles, an angular correction algorithm has been developed for the Climate Absolute Radiance and Refractivity Observatory Pathfinder (CPF) mission. This algorithm uses spectral correlation relationships to estimate differences in spectral radiances measured at different angles. This methodology can be extended for inter-calibrations between sensors measuring band radiances across a broad spectral region. We demonstrate its application in reducing angular mismatch errors between collocated measurements of multi-spectral imaging sensors, using the inter-calibration between the Moderate Resolution Imaging Spectrometer (MODIS) and the Visible Infrared Imaging Radiometer Suite (VIIRS) as an example. The angular correction allows for more relaxed collocation criteria so that more satellite-based inter-calibration samples can be utilized. Furthermore, implementing the angular correction algorithm improves inter-calibration accuracy in applications where angular mismatch errors have not been explicitly addressed previously.

Wan Wu↗

Statistical method for the prediction of matching results in spectral file searching

In file-search techniques, the distribution of mismatches quantitatively measures the fit of a particular unknown against a given library. A simple theoretical method is developed to predict, a priori, this distribution. With this procedure, for any unknown code and library, the mean number of mismatches can be calculated exactly. For a given library and coding scheme, the mismatch distribution for most unknown codes closely follows a common curve which is easily calculated from statistical properties of the library. When this common curve is normalized to a constant mean, the observed matching behavior is well predicted. The theory should permit the user to more clearly assess the effects of errors on file search performance and suggest techniques by which recognition performance may be optimized.

Grotch, S. L.↗