Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Milestone report for MRT 8504: Commission EXAFS spectrometer with spectral range of 17.95-18.6 keV design to obtain EXAFS data for Pu L shell experiments

This milestone describes the development and fielding of EXAFS Phase II spectrometer designed to provide high quality (SNR>=5) EXAFS spectra for Plutonium measurements at the National Ignition facility (NIF). Benefits: the EXAFS data will be used by the High Energy Density (HED) Physics and more specifically the Focused Material Science program to measure the thermal state of compressed materials with good temperature sensitivity (~100-1000 Kelvin). Data with good signal to noise ratio (SNR>=5) and good spectral resolution allows the FMS program to fill a gap in diagnosing temperature to completely constrain material properties for weapon physics and Stockpile Stewardship applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delivering Robust Proton-Only Sensing of Hyperpolarized [1,2- 13 C 2 ]-Pyruvate Using Broad-Spectral-Range Nuclear Magnetic Resonance Pulse Sequences

Hyperpolarized [1- 13 C]pyruvate is the leading hyperpolarized injectable contrast agent and is currently under evaluation in clinical trials for molecular imaging of metabolic diseases, including cardiovascular disease and cancer. One aspect limiting broad scalability of the technique is that hyperpolarized 13 C MRI requires specialized 13 C hardware and software that are not generally available on clinical MRI scanners, which employ proton-only detection. Here, we present an approach that uses pulse sequences to transfer 13 C hyperpolarization to methyl protons for detection of the 13 C– 13 C pyruvate singlet, employing proton-only excitation and detection only. The new pulse sequences are robust to the B 1 and B 0 magnetic field inhomogeneities. The work focuses on singlet-to-magnetization (S2M) and rotor-synchronized (R) pulses, both relying on trains of hard pulses with broad spectral width coverage designed to effectively transform hyperpolarized 13 C 2 -singlet hyperpolarization to 1 H polarization on the CH 3 group of [1,2- 13 C 2 ]pyruvate. Finally, this approach may enable a broader adoption of hyperpolarized MRI as a molecular imaging technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Superluminescent diodes in the spectral range of 1.5 – 1.6 μm based on strain-compensated AlGaInAs/InP quantum wells

Superluminescent diodes based on AlGaInAs/InP separate-confinement double heterostructures with strain-compensated quantum wells are investigated. The influence of elastic strains in the active region on the output characteristics of the devices is analysed. It is shown that such a design of a superluminescent diode allows an optical power of more than 5 mW, a radiation spectrum width of more than 60 nm, a degree of output radiation polarisation up to 30 dB to be obtained at the output of a single-mode fibre, and has a great potential for further improvement. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Seasonal variations of the microwave scattering properties of deciduous trees as measured in the 1-18 GHz spectral range

The author has identified the following significant results. Employing two FM-CW radar spectrometers, scattering data were acquired from stands of deciduous trees during the spring and autumn. The data suggest that the trees act as a volume scatter target particularly in the 7-18 GHz region. A comparison of data collected in spring and autumn indicates that the radar scattering coefficient, sigma deg, as measured in spring can be substantially larger (as much as 10 dB) than sigma deg as measured in the autumn.

Ulaby, F. T.↗

Blackbody curves for the IUE spectral range lambda 1150 to lamda 3200 from 6,000 to 200,000 K

Two sets of blackbody curves are presented for the wavelength region covering the international ultraviolet explorer spectrographs. One set is normalized to unity at 3200 A, the other is normalized at 1900 A for those astronomers primarily interested in data for the SWP range. The blackbody curves extend from 1150 to 3200 A and cover the temperature range from 6,000 to 200,000K.

Feibelman, W. A.↗

Large-Scale Structure of the Molecular Gas in Taurus Revealed by High Spatial Dynamic Range Spectral Line Mapping

Viewgraph topics include: optical image of Taurus; dust extinction in IR has provided a new tool for probing cloud morphology; observations of the gas can contribute critical information on gas temperature, gas column density and distribution, mass, and kinematics; the Taurus molecular cloud complex; average spectra in each mask region; mas 2 data; dealing with mask 1 data; behavior of mask 1 pixels; distribution of CO column densities; conversion to H2 column density; variable CO/H2 ratio with values much less than 10(exp -4) at low N indicated by UV results; histogram of N(H2) distribution; H2 column density distribution in Taurus; cumulative distribution of mass and area; lower CO fractional abundance in mask 0 and 1 regions greatly increases mass determined in the analysis; masses determined with variable X(CO) and including diffuse regions agrees well with the found from L(CO); distribution of young stars as a function of molecular column density; star formation efficiency; star formation rate and gas depletion; and enlarged images of some of the regions with numerous young stars. Additional slides examine the origin of the Taurus molecular cloud, evolution from HI gas, kinematics as a clue to its origin, and its relationship to star formation.

molecular clouds↗

Mapping minerals, amorphous materials, environmental materials, vegetation, water, ice and snow, and other materials: The USGS tricorder algorithm

One of the challenges of Imaging Spectroscopy is the identification, mapping and abundance determination of materials, whether mineral, vegetable, or liquid, given enough spectral range, spectral resolution, signal to noise, and spatial resolution. Many materials show diagnostic absorption features in the visual and near infrared region (0.4 to 2.5 micrometers) of the spectrum. This region is covered by the modern imaging spectrometers such as AVIRIS. The challenge is to identify the materials from absorption bands in their spectra, and determine what specific analyses must be done to derive particular parameters of interest, ranging from simply identifying its presence to deriving its abundance, or determining specific chemistry of the material. Recently, a new analysis algorithm was developed that uses a digital spectral library of known materials and a fast, modified-least-squares method of determining if a single spectral feature for a given material is present. Clark et al. made another advance in the mapping algorithm: simultaneously mapping multiple minerals using multiple spectral features. This was done by a modified-least-squares fit of spectral features, from data in a digital spectral library, to corresponding spectral features in the image data. This version has now been superseded by a more comprehensive spectral analysis system called Tricorder.

Clark, Roger N.↗

Ground state rotational and kinetic temperatures of C 2 molecules in a laser-produced plasma

This study presents an experimental comparison between rotational and kinetic temperatures of molecular species in a laser-produced plasma, utilizing tunable laser absorption spectroscopy. We analyzed high-resolution and time-resolved absorption spectra of 31 rotational transitions within the Phillips A 1 II u –X 1 Σ g 3-0 band of the C 2 molecule, measured from a laser-produced graphite plasma in ~2 Torr argon, within the 771–781 nm spectral range. Spectral fitting provided quantitative state column densities of C 2 rotational energy levels in the ground electronic and vibrational states. Boltzmann analysis revealed thermalized rotational distributions showing rotational temperatures decreasing from 3000 to 600 K within 5–500 μs following the onset of the laser plasma. The measured kinetic and rotational temperatures of C 2 molecules are comparable, suggesting that collisional processes in the laser-produced plasma are sufficient to maintain thermal equilibrium between the C 2 molecules and the Ar background gas.

Absorption spectroscopy↗

Spectroscopy in the 10 keV to 10 MeV range

Spectral lines in the 10 keV to 1 MeV range carry information of fundamental importance on many astronomical objects. Since the lines are directly related to specific physical processes this information is model independent and gives the physical conditions in the objects. At the sensitivities achieved to date, approximately 0.0001 to 0.001 phsq cm. sec for steady sources and approximately 0.01 to 1 ph/sq cm sec for transient sources, lines were detected from the galactic center, gamma-ray bursts and transients, X-ray pulsators, the Crab pulsar and solar flares. Future instruments with a factor of approximately 100 sensitivity improvement will allow detailed spectroscopic study of these classes of objects as well as supernova remnants, active galaxies and the interstellar medium. This sensitivity improvement can be obtained through the use of detector technology already proven in balloon and satellite instruments.

Matteson, J. L.↗

Broadband nonreciprocal thermal emissivity and absorptivity

A body that violates Kirchhoff’s law of thermal radiation exhibits an inequality in its spectral directional absorptivity and emissivity. Achieving such an inequality is of fundamental interest as well as a prerequisite for achieving thermodynamic limits in photonic energy conversion and radiative cooling. Thus far, inequalities in the spectral directional emissivity and absorptivity have been limited to narrow spectral resonances, or wavelengths well beyond the infrared regime4. Bridging the gap from basic demonstrations to practical applications requires control over a broad spectral range of the unequal spectral directional absorptivity and emissivity. In this work, we demonstrate broadband nonreciprocal thermal emissivity and absorptivity by measuring the thermal emissivity and absorptivity of gradient epsilon-near-zero InAs layers of subwavelength thicknesses (50 nm and 150 nm) with an external magnetic field. The effect occurs in a spectral range (12.5–16 μm) that overlaps with the infrared transparency window and is observed at moderate (1 T) magnetic fields.

42 ENGINEERING↗

Evaluation of an LED Simulator for Single- and Multi-Junction PV Cell Performance Testing

We present the evaluation of a solar simulator comprising a Light Emitting Diode (LED) array as its light source. While multiple applications can be envisioned for such a light source, here we focus on its use for performance testing of solar cells at Standard Test Conditions. With this in mind, we present characterization of the spatial uniformity of the irradiance and its temporal stability as well as the spectral range and spectral class. For a multisource simulator, the spectral uniformity across the test plane should also be evaluated and we discuss a method for performing this evaluation that is well suited to a solar cell performance testing application. One major advantage of this simulator is the ability to easily adjust the spectral output as needed in multijunction PV cell measurements and we also discuss this application here.

LED↗