Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Initial Assessment of the Impact of System Spectral Response Parameters on Driving Ocean Color Applications for the GeoXO Ocean Color Instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A dataset of high resolution (1 nm spectral sampling) in-situ spectra of red tide collected with an above water spectrometer, and associated K. brevis cell concentrations, were used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX. Future work will seek to expand this analysis to include a larger dataset that considers additional water cases.

M. Cook↗

Ferromagnetic resonance studies of thermal effects on lunar metallic Fe phases

Ferromagnetic resonance results of annealing experiments are discussed which illustrate the thermal effects on lunar metallic iron phases already present in a lunar fines sample. Spectral features of ferromagnetic resonance produced in the sample by heat treatments at temperatures between 600 and 1025 C are described which resemble those detected in lunar breccias and crystalline rocks. A correlation is shown to exist between these features and the degree of thermal metamorphism. It is noted that this correlation can be used as a built-in geothermometer or probe to investigate the thermal history and degree of metamorphism of a lunar sample containing metallic iron phases. The thermal history of a metaclastic rock is analyzed in this way, and it is shown that thermal metamorphism is an effective process for increasing relaxation times or the stability of the natural remanent magnetization carried by single-domain metallic iron particles.

Tsay, F.-D.↗

Optical Properties of Multi-Layered Insulation

Multi-layer insulation, MLI, is a material used on rocket bodies and satellites mainly for thermal insulation. MLI can be comprised of a variety of materials, layer numbers, and dimensions based on its purpose. A common composition of MLI consists of outer facing copper-colored Kapton with an aluminized backing for the top and bottom layers and the middle consisting of alternating layers of DARCON or Nomex netting with aluminized Mylar. If this material became separated from the spacecraft or rocket body its orbit would vary greatly in eccentricity due to its high area to mass (A/m) and susceptibility to solar radiation pressure perturbations. Recently a debris population was found with high A/m, which could be MLI. Laboratory photometric measurements of one intact piece and three different layers of MLI is presented in an effort to predict the characteristics of a MLI light curve and aid in identifying the source of the new population. For this paper, the layers used will be consistent with the common MLI mentioned in the above paragraph. Using a robotic arm, the piece was rotated from 0-360 degrees in one degree increments along the object s longest axis. Laboratory photometric data was recorded with a CCD camera using various filters (Johnson B, Johnson V and Bessell R). The measurements were taken at an 18 degree (light-object-camera) phase angle. As expected, the MLI pieces showed characteristics similar to a bimodal magnitude plot of a flat plate, but with more photometric features, dependant upon the layer of MLI. Time exposures varied from piece to piece such that the amount of pixels saturated would be minimal. In addition to photometric laboratory measurements, laboratory spectral measurements are shown for the same MLI samples. Spectral data will be combined to match the wavelength region of photometric data so a measure of truth can be established for the photometric measurements. Spectral data shows a strong absorption feature near 4800 angstroms, which is due to the copper color of Kapton. If the debris is MLI and the outer layer of copper coloring of Kapton is present, evidence would be seen spectrally by the specific absorption feature as well as using R-B (red-blue) light curves. Using laboratory photometric measurements and the results from spectral laboratory measurements, an optical property database is provided for an object with a high A/m. The benefits of this database for remote optical measurements of orbital debris are shown by illustrating the optical properties expected for a high A/m object, specifically common satellite and rocket body MLI.

Rodriguez, Heather M.↗

Ultra-Compact Imaging Spectrometer (UCIS) for In-Situ Planetary Mineralogy: Laboratory and Field Calibration

The Ultra-Compact Imaging Spectrometer (UCIS) is a miniature telescope and spectrometer system intended for mapping terrain mineralogy over distances from 1.5 m to infinity with spatial sampling of 1.35 mrad over a 33 deg field, and spectral sampling of 10 nm in the 600-2500 nm range. The core of the system has been designed for operation in a Martian environment, but can also be used in a terrestrial environment when placed inside a vacuum vessel. We report the laboratory and field calibration data that include spatial and spectral calibration, and demonstrate the use of the system.

Imaging spectroscopy↗

Harnessing CPF Hyperspectral Radiances to Homogenize Earth Observing Systems

Homogenization across Earth observing systems is essential for ensuring consistency in geophysical retrievals over time and enabling the construction of long-term climate records. As the first SI Traceable Satellite (SITSat) for the reflected solar, the CLARREO Pathfinder (CPF) will provide high-accuracy spectrally resolved benchmark measurements of Earth-reflected solar radiation, serving as a standardized in-orbit reference for other reflected solar (RS) instruments. The CPF intercalibration team has developed a state-of-the-art method to intercalibrate the RS channels of the VIIRS instrument onboard the NOAA-20 satellite using CPF benchmark measurements, aiming for a methodology uncertainty of 0.3-0.6% (1-sigma). To achieve this stringent accuracy, the CPF team has devised strategies to mitigate the effects of spatial, spectral, polarization, and angular disparities between the intercalibration footprints of CPF and VIIRS. Despite nearly identical instrument designs, the three VIIRS instruments currently in operation onboard SNPP, NOAA-20, and NOAA-21 platforms exhibit systematic radiometric biases up to 8%. Although each VIIRS sensor’s calibration is independent and traceable to standards maintained by NIST, there is significant concern within the community about which VIIRS sensor most accurately represents the absolute radiometric scale. The precise intercalibration between CPF and NOAA-20 VIIRS will reveal the absolute radiometric accuracy of VIIRS. This accuracy can then be extended to other RS sensors, including MODIS and other VIIRS sensors, via vicarious methods. The 3-nm spectral sampling of CPF measurements will enable users to quantify scene-dependent spectral biases between sensors, thereby aiding in establishing both spectral and radiometric homogenization across these platforms. The CPF mission overview, along with details of its intercalibration capabilities and homogenization approaches, will be discussed at the meeting.

Raj Bhatt↗

Visible and infrared linear detector arrays for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) instrument uses four separate focal plane assemblies consisting of line array detectors that are multiplexed to a common J-FET preamp using a FET switch multiplexing (MUX) technique. A 32-element silicon line array covers the spectral range from 0.41 to 0.70 microns. Three additional 64-element indium antimonide (InSb) line arrays cover the spectral range from 0.68 to 2.45 microns. The spectral sampling interval per detector element is nominally 9.8 nm, giving a total of 224 spectral channels. All focal planes operate at liquid nitrogen temperature and are housed in separate dewars. Electrical performance characteristics include a read noise of less than 1000 e(-) in all channels, response and dark nonuniformity of 5 percent peak to peak, and quantum efficiency of greater than 60 percent.

Bailey, Gary C.↗

Visible and infrared linear detector arrays for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) instrument uses four separate focal plane assemblies consisting of line array detectors that are multiplexed to a common J-FET preamp using a FET switch multiplexing (MUX) technique. A 32-element silicon line array covers the spectral range from 0.41 to 0.70 microns. Three additional 64-element indium antimonide (InSb) line arrays cover the spectral range from 0.68 to 2.45 microns. The spectral sampling interval per detector element is nominally 9.8 nm, giving a total of 224 spectral channels. All focal planes operate at liquid nitrogen temperature and are housed in separate dewars. Electrical performance characteristics include a read noise of less than 1000 e(-) in all channels, response and dark nonuniformity of 5 percent peak to peak, and quantum efficiency of greater than 60 percent.

Bailey, Gary C.↗

Moon Mineral Mapper (M3): A High Uniformity and High Precision Science Imaging Spectrometer in the Solar Reflected Spectrum

The Moon Mineralogy Mapper was selected as a NASA Discovery Mission of Opportunity in February 2005. At the core of this mission is an imaging spectrometer instrument with high spectral-spatial uniformity and high signal-to-noise ratio for the expected illumination conditions. The spectral range of the Moon Mineralogy Mapper is from 430 to 3000 nm with 10 nm spectral sampling. The radiometric range is from 0 to maximum expected radiance with 14 bit sampling. The spatial swath is nominally 40 Ian with 70 m spatial sampling. The Moon Mineralogy Mapper has both a global and target mode of data acquisition. In global spectral and spatial resolution full coverage of the Moon will be acquired. Target mode will be used to examine selected areas a full spectral and spatial resolution. The science objectives and mission and instrument characteristics are presented.

mapping↗

Simultaneous Sampling Of Two Spectral Sources

New technique uses bundle of fiber optics to sample a dye laser and a spectral lamp simultaneously. By use of real-time display with this sampling technique, two signals superimposed, and effect of any spectral adjustments determined immediately. System used to diagnose combustion.

Jarrett, Olin, Jr.↗

Search for evidence of low energy protons in solar flares

We searched for linear polarization in the H alpha line using the Stokes Polarimeter at Mees Solar Observatory and present observations of a flare from NOAA active region 6659 which began at 01:30 UT on 14 Jun. 1991. Our dataset also includes H alpha spectra from the Mees charge coupled device (MCCD) imaging spectrograph as well as hard x ray observations from the Burst and Transient Source Experiment (BATSE) instrument on board the Gamma Ray Observatory (GRO). The polarimeter scanned a 40 x 40 inch field of view using 16 raster points in a 4 x 4 grid. Each scan took about 30 seconds with 2 seconds at each raster point. The polarimeter stopped 8.5 inches between raster points and each point covered a 6 inch region. This sparse sampling increased the total field of view without reducing the temporal cadence. At each raster point, an H alpha spectrum with 20 mA spectral sampling is obtained covering 2.6 A centered on H alpha line center. The preliminary conclusions from the research are presented.

Metcalf, Thomas R.↗

Technologies for the multispectral mapping of earth resources

The application of solid-state detector array imaging to the remote sensing of the earth as a follow-on to currently planned Landsat missions provides the opportunity to achieve significantly increased performance. First-order advantages to be anticipated are higher sensitivity resulting in greater radiometric accuracies and improved geometric fidelity. The Multispectral Mapper design concept is responsive to a broad range of user needs by incorporating in-flight selection of spectral bands, instantaneous fields of view, and swath width. This versatility is achieved by the use of an imaging spectrometer which permits both spatial and spectral sampling in the image plane using area array detectors. Other improvements over the current Landsat multispectral scanner and Thematic Mapper include higher spatial resolution and inherently precise registration of the spectral bands. The key technologies required in order to realize these improvements include short-wavelength infrared detectors, wide field of view, broad spectral coverage optics, focal plane cooling, and high-speed onboard signal processing. Significant development activities will be required if an advanced remote sensing capability is to be implemented.

Wellman, J. B.↗

An Algorithm for Hyperspectral Remote Sensing of Aerosols: 3. Application to the GEO-TASO Data in KORUS-AQ Field Campaign

This paper describes the third part of a series of investigations to develop algorithms for simultaneous retrieval of aerosol parameters and surface spectral reflectance from the data measured by GEOstationary Trace gas and Aerosol Sensor Optimization (GEO-TASO) instrument. Since the algorithm is designed for future hyperspectral and geostationary satellite sensors, such as Tropospheric Emissions: Monitoring of Pollution (TEMPO), it is applied to GEO-TASO data measured over the same area by different flights as part of the Korea-United Stated Air Quality Study (KORUS-AQ) field campaign in 2016. While GEO-TAOS has a spectral sampling interval of ~0.28 nm in the visible, its data is thinned through a band selection approach with consideration of atmospheric transmittance and different surface types, which yields 20 common spectral bands to be used by the algorithm. The algorithm starts with 4 common principal components (PCs) for surface spectral reflectance extracted from various spectral libraries, and the constraints of surface reflectance parameters and aerosol scattering models respectively from k- means clustering analysis of the Rayleigh-corrected GEO-TASO spectra and AERONET data. The algorithm then proceeds iteratively with an optimal estimation approach to update PCs and retrieve aerosol optical depth (AOD) until the best match between simulated and GEOS-TASO measured spectra is achieved. The spectral AODs are compared between those retrieved from GEO-TASO (x) and 7 AERONETS (y) in 440, 550, 550, 675 nm, respectively. The comparison reveals that iterative updates of surface spectral PCs (and so surface reflectance) yield significant enhancement in AOD retrievals, improving the mean linear fitting equations from y = 0.735x + 0.088 (without update of PCs) to y = 1.055x+ 0.01, and the Pearson correlation coefficient (𝑅𝑅2) from 0.54 to 0.76, respectively. Move case studies are need to further evaluate the algorithm for its application to TEMPO that carries a enhanced version of GEO-TASO instrument.

Tropospheric Emissions: Monitoring of Pollution (T↗

Monitoring Earth's Shortwave Reflectance: GEO Instrument Concept

In this paper we present a GEO instrument concept dedicated to monitoring the Earth's global spectral reflectance with a high revisit rate. Based on our measurement goals, the ideal instrument needs to be highly sensitive (SNR greater than 100) and to achieve global coverage with spectral sampling (less than or equal to 10nm) and spatial sampling (less than or equal to 1km) over a large bandwidth (380-2510 nm) with a revisit time (greater than or equal to greater than or equal to 3x/day) sufficient to fully measure the spectral-radiometric-spatial evolution of clouds and confounding factor during daytime. After a brief study of existing instruments and their capabilities, we choose to use a GEO constellation of up to 6 satellites as a platform for this instrument concept in order to achieve the revisit time requirement with a single launch. We derive the main parameters of the instrument and show the above requirements can be fulfilled while retaining an instrument architecture as compact as possible by controlling the telescope aperture size and using a passively cooled detector.

geoengineering↗

A Multi-Scale Sampling Strategy for Detecting Physiologically Significant Signals in AVIRIS Imagery

Models of photosynthetic production at ecosystem and global scales require multiple input parameters specifying physical and physiological surface features. While certain physical parameters (e.g., absorbed photosynthetically active radiation) can be derived from current satellite sensors, other physiologically relevant measures (e.g., vegetation type, water status, carboxylation capacity, or photosynthetic light-use efficiency), are not generally directly available from current satellite sensors at the appropriate geographic scale. Consequently, many model parameters must be assumed or derived from independent sources, often at an inappropriate scale. An abundance of ecophysiological studies at the leaf and canopy scales suggests strong physiological control of vegetation-atmosphere CO2 and water vapor fluxes, particularly in evergreen vegetation subjected to diurnal or seasonal stresses. For example hot, dry conditions can lead to stomatal closure, and associated "downregulation" of photosynthetic biochemical processes, a phenomenon often manifested as a "midday photosynthetic depression". A recent study with the revised simple biosphere (SiB2) model demonstrated that photosynthetic downregulation can significantly impact global climate. However, at the global scale, the exact significance of downregulation remains unclear, largely because appropriate physiological measures are generally unavailable at this scale. Clearly, there is a need to develop reliable ways of extracting physiologically relevant information from remote sensing. Narrow-band spectrometers offer many opportunities for deriving physiological parameters needed for ecosystem and global scale photosynthetic models. Experimental studies on the ground at the leaf- to stand-scale have indicated that several narrow-band features can be used to detect plant physiological status. One physiological signal is caused by xanthophyll cycle pigment activity, and is often expressed as the Photochemical Reflectance Index (PRI). Because the xanthophyll cycle pigments are photoregulatory pigments closely linked to photosynthetic function, this index can be used to derive relative photosynthetic rates. An additional signal with physiological significance is the 970 nm water absorption band, which provides a measure of liquid water content. This feature has been quantified both using a simple 2-band ratio (900/970 nm, here referred to as the "Water Band Index" or WBI;), and using the "continuum removal" method. Current atmospheric correction methods for AVIRIS imagery also obtain quantitative expressions of surface liquid water absorption based on the 970 nm water band and may be comparable to ground-based estimates of water content using this feature. However, physiological interpretations of both the PRI and the WBI are best understood at the leaf and canopy scales, where complications of atmospheric interference and complex stand and landscape features can be minimized, and where experimental manipulations can be readily applied. Currently it is not known whether these physiological indices can be used to derive meaningful physiological information from AVIRIS imagery. In addition to the problem of atmospheric interference, another challenge is that any simple physiological index can be confounded by multiple factors unrelated to physiology, and this problem can become more severe at progressively larger spatial scales. For example, previous work has suggested that both the PRI and the WBI, are strongly correlated with other optical measures of canopy structure (e.g., the Normalized Difference Vegetation Index or green vegetation fraction), indicating a confounding effect of structure on physiological signals at the larger, landscape scale. Furthermore, the normal operating mode of most imaging spectrometers does not allow simultaneous, ground truthing at a level of detail needed for physiological sampling. Additionally, manipulative experiments of physiology are difficult to apply at a geographic scale suitable for comparison with remote imagery, which often works at spatial scales that are several orders of magnitude larger than those typically used for physiological studies. These limitations require the consideration of alternative approaches to validating physiological information derived from AVIRIS data. In this report, we present a multi-scale sampling approach to detecting physiologically significant signals in narrow-band spectra. This approach explores the multi-dimensional data space provided by narrow-band spectrometry, and combines AVIRIS imagery at a large scale, with ground spectral sampling at an intermediate scale, and detailed ecophysiological measurements at a fine scale, to examine seasonally and spatially changing relationships between multiple structural and physiological variables. Examples of this approach are provided by simultaneous sampling of the Normalized Difference Vegetation Index (NDVI), an index of fractional PAR interception and green vegetation cover, the Water Band Index (WBI, an index of liquid water absorption, and the Photochemical Reflectance Index (PRI, an index of xanthophyll cycle pigment activity and photosynthetic light-use efficiency. By directly linking changing optical properties sampled on the ground with measurable physiological states, we hope to develop a basis for interpreting similar signals in AVIRIS imagery.

Gamon, John A.↗

Optical Design of a Compact Imaging Spectrometer for Planetary Mineralogy

We present the design of a compact, wide-angle pushbroom imaging spectrometer suitable for exploration of solar system bodies from low orbit. The spectrometer is based on a single detector array with a broadband response that covers the range 400 to 3000 nm and provides a spectral sampling of 10 nm. The telescope has a 24-deg field of view with 600 spatially resolved elements (detector pixels). A specially designed convex diffraction grating permits optimization of the signal-to-noise ratio through the entire spectral band. Tolerances and design parameters permit the achievement of high uniformity of response through field and wavelength. The spectrometer performance is evaluated in terms of predicted spectral and spatial response functions and from the point of view of minimizing their variation through field and wavelength. The design serves as an example for illustrating the design principles specific to this type of system.

space optics↗

Evaluation of the airborne visible-infrared imaging spectrometer for mapping subtle lithological variation

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), flown aboard the NASA ER-2 aircraft in 1987 and 1989, used four linear arrays and four individual spectrometers to collect data simultaneously from the 224 bands in a scanned 614 pixel-wide swath perpendicular to the aircraft direction. The research had two goals. One was to evaluate the AVIRIS data. The other was to look at the subtle lithological variation at the two test sites to develop a better understanding of the regional geology and surficial processes. The geometric characteristics of the data, adequacy of the spatial resolution, and adequacy of the spectral sampling interval are evaluated. Geologic differences at the test sites were mapped. They included lithological variation caused by primary sedimentary layering, facies variation, and weathering; and subtle mineralogical differences caused by hydrothermal alterations of igneous and sedimentary rocks. The investigation used laboratory, field, and aircraft spectral measurements; known properties of geological materials; digital image processing and spectrum processing techniques; and field geologic data to evaluate the selected characteristics of the AVIRIS data.

Kruse, Fred A.↗

Remote spectral identification of surface aggregates by thermal imaging techniques - Progress report

The NASA Thermal Infrared Multispectral Scanner (TIMS) has been successfully used for the remote identification of a variety of soil and aggregate deposits in vegetated areas of two states. Over three million cubic meters of gravel deposits were identified from the imagery during a two year period. Verification was accomplished by ground reconnaissance using drilling machinery and by ground instrumentation. The method has been used to differentiate between fine and coarse grained soils, and gravel deposits. The deposits were found to have been naturally sorted according to grain size by depositional processes, providing each deposit with distinct spectral qualities. It was found that the masking effects of relatively dense vegetation were largely overcome by using imagery acquired at higher altitudes above terrain than 9000 meters, due to loss of resolution of the finer detail. The mechanics of image resolution are discussed, a method of data analysis used is described, and sample spectral signatures are illustrated.

Scholen, Douglas E.↗

Discriminating Phytoplankton Functional Types (PFTs) in the Coastal Ocean Using the Inversion Algorithm Phydotax and Airborne Imaging Spectrometer Data

There is a need in the Biological Oceanography community to discriminate among phytoplankton groups within the bulk chlorophyll pool to understand energy flow through ecosystems, to track the fate of carbon in the ocean, and to detect and monitor-for harmful algal blooms (HABs). The ocean color community has responded to this demand with the development of phytoplankton functional type (PFT) discrimination algorithms. These PFT algorithms fall into one of three categories depending on the science application: size-based, biogeochemical function, and taxonomy. The new PFT algorithm Phytoplankton Detection with Optics (PHYDOTax) is an inversion algorithm that discriminates taxon-specific biomass to differentiate among six taxa found in the California Current System: diatoms, dinoflagellates, haptophytes, chlorophytes, cryptophytes, and cyanophytes. PHYDOTax was developed and validated in Monterey Bay, CA for the high resolution imaging spectrometer, Spectroscopic Aerial Mapping System with On-board Navigation (SAMSON - 3.5 nm resolution). PHYDOTax exploits the high spectral resolution of an imaging spectrometer and the improved spatial resolution that airborne data provides for coastal areas. The objective of this study was to apply PHYDOTax to a relatively lower resolution imaging spectrometer to test the algorithm's sensitivity to atmospheric correction, to evaluate capability with other sensors, and to determine if down-sampling spectral resolution would degrade its ability to discriminate among phytoplankton taxa. This study is a part of the larger Hyperspectral Infrared Imager (HyspIRI) airborne simulation campaign which is collecting Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) imagery aboard NASA's ER-2 aircraft during three seasons in each of two years over terrestrial and marine targets in California. Our aquatic component seeks to develop and test algorithms to retrieve water quality properties (e.g. HABs and river plumes) in both marine and in-land water bodies. Results presented are from the 10 April 2013 overflight of the Monterey Bay region and focus primarily on the first objective - sensitivity to atmospheric correction. On-going and future work will continue to evaluate if PHYDOTax can be applied to historical (SeaWiFS and MERIS), existing (MODIS, VIIRS, and HICO), and future (PACE, GEO-CAPE, and HyspIRI) satellite sensors. Demonstration of cross-platform continuity may aid in calibration and validation efforts of these sensors.

Biological Oceanography↗