Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectroscopic methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spectroscopic methods and systems for isotopic analysis

Disclosed are spectroscopy systems and methods. A spectroscopy system can include a reference cell and a multi-pass sample cell. The reference arm can include an etalon and a reference cavity containing a reference gas. A system can include a fractional sublimation cold trap. Detectors of the reference and sample arms can detect both intensity and absorption spectra of impinging beams. A frequency calibration based on a reference absorption spectra can be used to analyze a sample absorption spectrum. The analysis can provide information regarding an absorption band shift of the sample absorption spectrum, said shift being related to the isotope concentration of the sample.

O'Rourke, Patrick E.↗

Analytical Methods for Biomass Characterization and Conversion

Analytical Methods for Biomass Characterization and Conversion is a thorough resource for researchers, students and professors who investigate the use of biomass for fuels, chemicals and products. Advanced analytical chemistry methods and techniques can now provide detailed compositional and chemical measurements of biomass, biomass conversion process streams, intermediates and products. This volume from the Emerging Issues in Analytical Chemistry series brings together the current knowledge on each of these methods, including spectroscopic methods (Fourier Transform Infrared Spectroscopy, Near-infrared Spectroscopy, Solid State Nuclear Magnetic Resonance), pyrolysis (Gas Chromatography/Mass Spectrometry), Liquid Chromatography/High Performance Liquid Chromatography, Liquid Chromatography/Mass Spectrometry, and so on.

09 BIOMASS FUELS↗

Scanning Tunneling Microscopy methods for spectroscopic imaging of subsurface interfaces

A new method for spatially-resolved, spectroscopic investigation of subsurface interface structure has been developed. The method, Ballistic Electron Emission Microscopy (BEEM), is based on Scanning Tunneling Microscopy (STM) techniques. BEEM combines STM vacuum tunneling with unique ballistic electron spectroscopy capabilities. BEEM enables, for the first time, direct imaging of subsurface interface electronic properties with nanometer spatial resolution. STM topographic images of surface structure and BEEM images of subsurface properties are obtained simultaneously. BEEM capabilities are demonstrated by investigation of important metal-semiconductor interfaces.

Bell, L. D.↗

Perturbative theoretical model of electronic transient circular dichroism spectroscopy of molecular aggregates

A chiral analog of transient absorption spectroscopy, transient circular dichroism (TCD) spectroscopy is an emerging time-resolved method. Both spectroscopic methods can probe the electronic transitions of a sample, and TCD is additionally sensitive to the dynamic aspects of chirality, such as those induced by molecular excitons. Here, we develop a theoretical description of TCD for electronic multi-level models in which the pump pulse is linearly polarized and probe pulse is alternately left- and right-circularly polarized. We derive effective response functions analogous to those often used to describe other four-wave mixing methods and then simulate and analyze TCD spectra for three representative multi-level electronic model systems. We elaborate on the presence and detection of the spectral signatures of electronic coherences.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Electronic Structure, Bonding and Reactivity in f-Element Chemistry (Final Technical Report)

The proposed research aims to further develop and apply advanced inorganic spectroscopic methods to f-element systems, including well-defined compounds, in-situ generated complexes (including potentially complex mixtures) and transient species. Our long term goal is to develop and apply advanced inorganic spectroscopic methods in f-element chemistry in order to advance our understanding of electronic structure, bonding and reactivity in f-element systems up to the level currently available for d-block systems. A further goal of our program is the training and development of graduate students in the application of advanced inorganic spectroscopic methods for the study of f-element systems, which is critically underdeveloped at US academic institutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic Chemical Analysis Methods and Apparatus

This invention relates to non-contact spectroscopic methods and apparatus for performing chemical analysis and the ideal wavelengths and sources needed for this analysis. It employs deep ultraviolet (200- to 300-nm spectral range) electron-beam-pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor lightemitting devices, and hollow cathode metal ion lasers. Three achieved goals for this innovation are to reduce the size (under 20 L), reduce the weight [under 100 lb (.45 kg)], and reduce the power consumption (under 100 W). This method can be used in microscope or macroscope to provide measurement of Raman and/or native fluorescence emission spectra either by point-by-point measurement, or by global imaging of emissions within specific ultraviolet spectral bands. In other embodiments, the method can be used in analytical instruments such as capillary electrophoresis, capillary electro-chromatography, high-performance liquid chromatography, flow cytometry, and related instruments for detection and identification of unknown analytes using a combination of native fluorescence and/or Raman spectroscopic methods. This design provides an electron-beampumped semiconductor radiation-producing method, or source, that can emit at a wavelength (or wavelengths) below 300 nm, e.g. in the deep ultraviolet between about 200 and 300 nm, and more preferably less than 260 nm. In some variations, the method is to produce incoherent radiation, while in other implementations it produces laser radiation. In some variations, this object is achieved by using an AlGaN emission medium, while in other implementations a diamond emission medium may be used. This instrument irradiates a sample with deep UV radiation, and then uses an improved filter for separating wavelengths to be detected. This provides a multi-stage analysis of the sample. To avoid the difficulties related to producing deep UV semiconductor sources, a pumping approach has been developed that uses ballistic electron beam injection directly into the active region of a wide bandgap semiconductor material.

Hug, William F.↗

The development and applications of multidimensional biomolecular spectroscopy illustrated by photosynthetic light harvesting

The parallel and synergistic developments of atomic resolution structural information, new spectroscopic methods, their underpinning formalism, and the application of sophisticated theoretical methods have led to a step function change in our understanding of photosynthetic light harvesting, the process by which photosynthetic organisms collect solar energy and supply it to their reaction centers to initiate the chemistry of photosynthesis. The new spectroscopic methods, in particular multidimensional spectroscopies, have enabled a transition from recording rates of processes to focusing on mechanism. We discuss two ultrafast spectroscopies – two-dimensional electronic spectroscopy and two-dimensional electronic-vibrational spectroscopy – and illustrate their development through the lens of photosynthetic light harvesting. Both spectroscopies provide enhanced spectral resolution and, in different ways, reveal pathways of energy flow and coherent oscillations which relate to the quantum mechanical mixing of, for example, electronic excitations (excitons) and nuclear motions. The new types of information present in these spectra provoked the application of sophisticated quantum dynamical theories to describe the temporal evolution of the spectra and provide new questions for experimental investigation. While multidimensional spectroscopies have applications in many other areas of science, we feel that the investigation of photosynthetic light harvesting has had the largest influence on the development of spectroscopic and theoretical methods for the study of quantum dynamics in biology, hence the focus of this review. We conclude with key questions for the next decade of this review.

59 BASIC BIOLOGICAL SCIENCES↗

Rare Earth Nitrate Hybrid Double Perovskites [Me 4 N] 2 [MLn(NO 3 ) 6 ] (M = Na–Cs; Ln = La–Gd, ex. Pm)

An exploration of the synthetic and structural phase space of rare earth hybrid double perovskites A 2 B'BX 6 (A = organocation, B' = M + , B = M 3+ , X = molecular bridging anion) that include X = NO 3 – and B' = alkali metal is reported, complementing earlier studies of the [Me 4 N] 2 [KB(NO 3 ) 6 ] (B = Am, Cm, La–Nd, Sm–Lu, Y) (Me 4 N = (CH 3 ) 4 N + ) compounds. In the present efforts, the synthetic phase space of these systems is explored by varying the identity of the alkali metal ion at the B'-site. Herein, we report three new series of the form [Me 4 N] 2 [B'B(NO 3 ) 6 ] (B = La–Nd, Sm–Gd; B' = Na, Rb, Cs). The early members of the Na-series crystallize in the trigonal space group R3̅ from La to Nd where a phase transition occurs in the phase between 273 and 300 K, going from R3̅ to the high-symmetry, cubic space group Fm3̅m. The preceding trigonal members of the Na-series also undergo phase transitions to cubic symmetry at temperatures above 300 K, establishing a decreasing trend in the phase-transition temperature. The remainder of the Na-series, as well as the Rb- and Cs-series, all crystallize in Fm3̅m at 300 K. The temperature-dependent phase behavior of the synthesized phases is studied via variable-temperature spectroscopic methods and high-resolution powder X-ray diffractometry. All phases were characterized via single-crystal and powder X-ray diffraction and Fourier transform infrared (FT-IR) and Raman spectroscopic methods. These results demonstrate the versatility of the perovskite structure type to include rare earth ions, nitrate ions, and a suite of alkali metal ions and serve as a foundation for the design of functional rare earth hybrid double perovskite materials such as those possessing useful multiferroic, optical, and magnetic properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System and method for assessing spectroscopic sensor accuracy

A method for assessing spectroscopic sensor accuracy, includes building an a priori simulation of generalized etalon drift. A spectroscopic sensor is tested to determine use parameters. A specific drift model is generated by applying the determined use parameters to the built a priori simulation of generalized etalon drift. The specific drift model is analyzed to determine whether the spectroscopic sensor is satisfactory.

Green, William J.↗

The chemRIXS Instrument for Solution-Phase Resonant Inelastic X-ray Scattering at the Linac Coherent Light Source

The chemRIXS instrument at the Linac Coherent Light Source (LCLS) offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopic methods such as resonant inelastic X-ray scattering (RIXS) using the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and RIXS to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopic methods on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental determination of electron attenuation lengths in complex materials by means of epitaxial film growth: advantages and challenges

Accurate electron attenuation lengths are of critical importance in using electron spectroscopic methods to quantitatively characterize complex materials. Here we show that analysis of core-level and valence-band x-ray photoelectron spectra excited with monochromatic AlK? x-rays from the substrate and measured as a function of film thickness can be used to determine electron attenuation lengths in epitaxial SrTiO3 films on Ge(001). Closely lattice-matched epitaxial heterojunctions are ideal systems for determining attenuation lengths provided the films grow in a layer-by-layer fashion, leading to atomically flat surfaces, and the buried interfaces are atomically abrupt. In principle, either the rate of attenuation of substrate peak intensities or the rate of increase of film peak intensities can be used for this purpose. However, we find that structural nonuniformities in the films reduce the accuracy of electron attenuation lengths determined from photoelectrons that originate within the films. A more reliable source of information is found in photoelectrons from the substrate which traverse the film. By using the energy dependence of calculated electron attenuation lengths from the NIST database in combination with Ge 3d core and Ge-derived valence band intensities, we determine electron attenuation length as a function of kinetic energy for SrTiO3.

Chambers, Scott A.↗

H β and H γ Absorption-line Profile Inconsistencies in Laboratory Experiments Performed at White Dwarf Photosphere Conditions

The spectroscopic method relies on hydrogen Balmer absorption lines to infer white dwarf (WD) masses. These masses depend on the choice of atmosphere model, hydrogen atomic line shape calculation, and which Balmer series members are included in the spectral fit. In addition to those variables, spectroscopic masses disagree with those derived using other methods. Here we present laboratory experiments aimed at investigating the main component of the spectroscopic method: hydrogen line shape calculations. These experiments use X-rays from Sandia National Laboratories’ Z-machine to create a uniform ~15 cm 3 hydrogen plasma and a ~4 eV backlighter that enables recording high-quality absorption spectra. The large plasma, volumetric X-ray heating that fosters plasma uniformity, and the ability to collect absorption spectra at WD photosphere conditions are improvements over past laboratory experiments. Analysis of the experimental absorption spectra reveals that electron density (n e ) values derived from the Hγ line are ~34% ± 7.3% lower than from Hβ. Two potential systematic errors that may contribute to this difference were investigated. A detailed evaluation of self-emission and plasma gradients shows that these phenomena are unlikely to produce any measurable Hβ–Hγ n e difference. WD masses inferred with the spectroscopic method are proportional to the photosphere density. Hence, the measured Hβ–Hγ n e difference is qualitatively consistent with the trend that WD masses inferred from their Hβ line are higher than that resulting from the analysis of Hβ and Hγ. In conclusion, this evidence may suggest that current hydrogen line shape calculations are not sufficiently accurate to capture the intricacies of the Balmer series.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗