Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrum training”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimal design and evaluation criteria for acoustic emission pulse signature analysis

Successful pulse recording and evaluation is strongly dependent on the instrumentation system selected and the method of analyzing the pulse signature. The paper studies system design, signal analysis techniques, and interdependences with a view toward defining optimal approaches to pulse signal analysis. For this purpose, the instrumentation system is modeled, and analytical pulses, representative of the types of acoustic emissions to be distinguished are passed through the system. Particular attention is given to comparing frequency spectrum analysis and deconvolution referred to as time domain reconstruction of the pulse or pulse train. The possibility of optimal transducer-filter system parameters is investigated. Deconvolution of a pulse is shown to be a superior approach for transient pulse analysis. Reshaping of a transducer output back to the original input pulse is possible and gives an accurate representation of the generating pulse in the time domain. Any definable transducer and filter system can be used for measurement of pulses by means of the deconvolution method. Selection of design variables for general usage is discussed.

Houghton, J. R.↗

SETI Pulse Detection Algorithm: Analysis of False-alarm Rates

Some earlier work by the Search for Extraterrestrial Intelligence (SETI) Science Working Group (SWG) on the derivation of spectrum analyzer thresholds for a pulse detection algorithm based on an analysis of false alarm rates is extended. The algorithm previously analyzed was intended to detect a finite sequence of i periodically spaced pulses that did not necessarily occupy the entire observation interval. This algorithm would recognize the presence of such a signal only if all i-received pulse powers exceeded a threshold T(i): these thresholds were selected to achieve a desired false alarm rate, independent of i. To simplify the analysis, it was assumed that the pulses were synchronous with the spectrum sample times. This analysis extends the earlier effort to include infinite and/or asynchronous pulse trains. Furthermore, to decrease the possibility of missing an extraterrestrial intelligence signal, the algorithm was modified to detect a pulse train even if some of the received pulse powers fall below the threshold. The analysis employs geometrical arguments that make it conceptually easy to incorporate boundary conditions imposed on the derivation of the false alarm rates. While the exact results can be somewhat complex, simple closed form approximations are derived that produce a negligible loss of accuracy.

Levitt, B. K.↗

Classification Of Land Cover From Airborne MSS Data

Method for processing images of rural uplands produced by airborne multispectral scanner (MSS), semiautomatically classifies types of land cover, and involves selection of wavelength bands, radiometric calibration, correction for effects of scan angle and atmosphere, training, and assessment of accuracy. Basic version involves classification of each picture element according to spectrum. Augmented with five refinements to increase accuracy: per-field sampling; low-pass filtering; image texture; prior probabilities; and imagery from two dates.

Curran, Paul J.↗

Maintaining Human Health for Humans-Mars

The Human Health Research Program states that Radiation is the most challenging hazard to human spaceflight beyond LEO. The International Space Station provides an analog for evaluating techniques for dealing with Altered Gravity, the Radiation Environment of the ISS is only about 45% of the deep space values where radiation due to Galactic Cosmic Rays (GCR) dominate the spectrum. The Moon and cis-lunar space are being considered as a Mars Analog training ground for preparing crews for human mission to Mars. Spending more than 200 days in deep space is considered unsafe based on our current proxy for lifetime radiation dose. The paper outlines a way forward for spending days training near the Moon and for completing roundtrip missions to Mars while remaining below the current proxy. In the first case, a GCR overcoat shields crews from radiation during cis-lunar activities before making fast transits without in-space GCR overcoats to and from Mars. This case requires continued maturation of low TRL propulsion and power technologies currently around 4 to 5 while depending on repeatable reductions in launch costs by a factor of 6 expected of current reusable rockets. The second case requires no new technology development except for the expectation that the next near-term generation of reusable rockets will reduce launch costs by a factor of around 14. Five trajectories and GCR overcoat sizes for all mission legs are presented herein to illustrate the opportunities to maintain human health for Humans-Mars missions.

Robert W Moses↗

Spectral Gap Filling Method Using the Spectral Information from CLARREO-Pathfinder Measured Earth-Reflected Solar Spectra to Support CPF-CERES Intercalibration

The high-accuracy Earth-reflected solar spectral radiances from CLARREO Pathfinder (CPF) will serve as in-orbit benchmark measurements for intercalibrating other satellite imagers. The CPF team is developing a state-of-the-art intercalibration method to calibrate the shortwave channel (300-5000 nm) of the CERES instrument against the CPF reference with an uncertainty of 0.3%. Because the CPF instrument only covers spectral range from 350 nm to 2300 nm, the team has developed a spectral extension method to fill in the gaps between the spectral domains of CPF and the CERES shortwave channel. The method solely relies on using the hyperspectral information from the CPF wavelengths to predict the radiances below 350 nm and above 2300 nm. To quantify the relationship between the CPF spectrum and the non-overlapping portions of the spectrum between CPF and CERES, the team has simulated a large ensemble of spectra that cover the spectral range for both CPF and CERES. A hyperspectral bidirectional reflectance model for land surface based on thousands of measured land surface reflectance has been developed. This land surface model as well as the Cox-Munk model for ocean surface are used in the spectral gap filling. Various water/ice clouds, aerosols, atmosphere profiles and surfaces were used to simulate Earth-reflected radiances from 200 nm to 15 um under different solar and sensor geometries. The targeted uncertainty for the CPF-extended broadband CERES radiances is less than 0.1%. The previously derived training spectra were updated to replace the Kurucz solar irradiance model with the TSIS-1 Hybrid Solar Reference Spectrum. The influence of the scalar assumption in radiative transfer model equations on the uncertainty in estimating the broadband radiances was also investigated.

Hyperspectral↗

Effect of signal jitter on the spectrum of rotor impulsive noise

The effect of randomness or jitter of the acoustic waveform on the spectrum of rotor impulsive noise is studied because of its importance for data interpretation. An acoustic waveform train is modelled representing rotor impulsive noise. The amplitude, shape, and period between occurrences of individual pulses are allowed to be randomized assuming normal probability distributions. Results, in terms of the standard deviations of the variable quantities, are given for the autospectrum as well as special processed spectra designed to separate harmonic and broadband rotor noise components. Consideration is given to the effect of accuracy in triggering or keying to a rotor one per revolution signal. An example is given showing the resultant spectral smearing at the high frequencies due to the pulse signal period variability.

Brooks, Thomas F.↗

Effect of signal jitter on the spectrum of rotor impulsive noise

The effect of randomness or jitter of the acoustic waveform on the spectrum of rotor impulsive noise is studied because of its importance for data interpretation. An acoustic waveform train is modeled representing rotor impulsive noise. The amplitude, shape, and period between occurrences of individual pulses are allowed to be randomized assuming normal probability distributions. Results, in terms of the standard deviations of the variable quantities, are given for the autospectrum as well as special processed spectra designed to separate harmonic and broadband rotor noise components. Consideration is given to the effect of accuracy in triggering or keying to a rotor one per revolution signal. An example is given showing the resultant spectral smearing at the high frequencies due to the pulse signal period variability.

Brooks, Thomas F.↗

On Looking into the Black Box: Prospects and Limits in the Search for Mental Models

To place the arguments advanced in this paper in alternative points of view with regard to mental models are reviewed. Use of the construct in areas such as neural information processing, manual control, decision making, problem solving, and cognitive science are discussed. Also reviewed are several taxonomies of mental models. The available empirical evidence for answering questions concerning the nature and usage of mental models is then discussed. A variety of studies are reviewed where the type and form of humans' knowledge have been manipulated. Also considered are numerous transfer of training studies whose results provide indirect evidence of the nature of mental models. The alternative perspectives considered and the spectrum of empirical evidence are combined to suggest a framework within which research on mental models can be viewed. By considering interactions of dimensions of this framework, the most salient unanswered questions can be identified.

Rouse, W. B.↗

Patterns of Activity in A Global Model of A Solar Active Region

In this work we investigate the global activity patterns predicted from a model active region heated by distributions of nanoflares that have a range of frequencies. What differs is the average frequency of the distributions. The activity patterns are manifested in time lag maps of narrow-band instrument channel pairs. We combine hydrodynamic and forward modeling codes with a magnetic field extrapolation to create a model active region and apply the time lag method to synthetic observations. Our aim is not to reproduce a particular set of observations in detail, but to recover some typical properties and patterns observed in active regions. Our key findings are the following. (1) Cooling dominates the time lag signature and the time lags between the channel pairs are generally consistent with observed values. (2) Shorter coronal loops in the core cool more quickly than longer loops at the periphery. (3) All channel pairs show zero time lag when the line of sight passes through coronal loop footpoints. (4) There is strong evidence that plasma must be re-energized on a timescale comparable to the cooling timescale to reproduce the observed coronal activity, but it is likely that a relatively broad spectrum of heating frequencies are operating across active regions. (5) Due to their highly dynamic nature, we find nanoflare trains produce zero time lags along entire flux tubes in our model active region that are seen between the same channel pairs in observed active regions.

Bradshaw, S. J.↗

Identification and proposed control of helicopter transmission noise at the source

Helicopter cabin interiors require noise treatment which is expensive and adds weight. The gears inside the main power transmission are major sources of cabin noise. Work conducted by the NASA Lewis Research Center in measuring cabin interior noise and in relating the noise spectrum to the gear vibration of the Army OH-58 helicopter is described. Flight test data indicate that the planetary gear train is a major source of cabin noise and that other low frequency sources are present that could dominate the cabin noise. Companion vibration measurements were made in a transmission test stand, revealing that the single largest contributor to the transmission vibration was the spiral bevel gear mesh. The current understanding of the nature and causes of gear and transmission noise is discussed. It is believed that the kinematical errors of the gear mesh have a strong influence on that noise. The completed NASA/Army sponsored research that applies to transmission noise reduction is summarized. The continuing research program is also reviewed.

Coy, John J.↗

Identification and proposed control of helicopter transmission noise at the source

Helicopter cabin interiors require noise treatment which is expensive and adds weight. The gears inside the main power transmission are major sources of cabin noise. Work conducted by the NASA Lewis Research Center in measuring cabin interior noise and in relating the noise spectrum to the gear vibration of the Army OH-58 helicopter is described. Flight test data indicate that the planetary gear train is a major source of cabin noise and that other low frequency sources are present that could dominate the cabin noise. Companion vibration measurements were made in a transmission test stand, revealing that the single largest contributor to the transmission vibration was the spiral bevel gear mesh. The current understanding of the nature and causes of gear and transmission noise is discussed. It is believed that the kinematical errors of the gear mesh have a strong influence on that noise. The completed NASA/Army sponsored research that applies to transmission noise reduction is summarized. The continuing research program is also reviewed.

Coy, John J.↗

Delaying Trains of Short Light Pulses in WGM Resonators

Suitably configured whispering-gallery-mode (WGM) optical resonators have been proposed as delay lines for trains of short light pulses. Until now, it has been common practice to implement an optical delay line as a coiled long optical fiber, which is bulky and tends to be noisy. An alternative has been to implement an optical delay line as a coupled-resonator optical waveguide (a chain of coupled optical resonators), which is compact but limits the width of the pulse spectrum to the width of an optical resonance and thereby places a lower limit on the duration of a pulse. In contrast, a delay line according to the proposal could be implemented as a single WGM resonator, and the pulses delayed by the resonator could be so short that their spectral widths could greatly exceed the spectral width of any single resonance. The proposal emerged from theoretical and experimental studies of the propagation of a pulse train in a WGM resonator. An important element of the theoretical study was recognition that the traditional definition of group velocity in effect, the velocity of a single pulse comprising a packet of waves propagating in a medium, the responsivity of which is a monotonous function of frequency does not necessarily apply in the case of a WGM resonator or other medium having a spectrum consisting of discrete resonance peaks at different frequencies. A new definition of group velocity, applicable to a train of pulses propagating in such a medium, was introduced and found to lead to the discovery of previously unknown features of propagation. Notably, it was found that in a micro - sphere optical resonator that supports a suitable combination of WGM modes, the group velocity for a train of light pulses could be positive, zero, or negative. A positive group velocity could be so small that the delay could be much longer than the ring-down time of the resonator; a delay of such great length is impossible for a single pulse interacting with either a linearly responding lossless resonator or a coupled- resonator optical waveguide.

Matsko, Andrey↗

Study of the development of natural instabilities in a laminar boundary layer in incompressible flow

Natural instabilities which are created in a laminar boundary layer and which consist of intermittent wave trains were studied. The spectral analysis of these fluctuations makes it possible to localize them in terms of frequency and to isolate their spectrum of amplitude modulation. The variation in terms of abscissa value and ordinate value of these instabilities is compared with the results derived from the solution of the Orr-Sommerfeld equation.

Burnel, S.↗

Wavelength independent interferometer

A polychromatic interferometer utilizing a plurality of parabolic reflective surfaces to properly preserve the fidelity of light wavefronts irrespective of their wavelengths as they pass through the instrument is disclosed. A preferred embodiment of the invention utilizes an optical train which comprises three off-axis parabolas arranged in conjunction with a beam-splitter and a reference mirror to form a Twyman-Green interferometer. An illumination subsystem is provided and comprises a pair of lasers at different preselected wavelengths in the visible spectrum. The output light of the two lasers is coaxially combined by means of a plurality of reflectors and a grating beam combiner to form a single light source at the focal point of the first parabolic reflection surface which acts as a beam collimator for the rest of the optical train. By using visible light having two distinct wavelengths, the present invention provides a long equivalent wavelength interferogram which operates at visible light wherein the effective wavelength is equal to the product of the wavelengths of the two laser sources divided by their difference in wavelength. As a result, the invention provides the advantages of what amounts to long wavelength interferometry but without incurring the disadvantage of the negligible reflection coefficient of the human eye to long wavelength frequencies which would otherwise defeat any attempt to form an interferogram at that low frequency using only one light source.

Hochberg, Eric B.↗

Doppler lidar processing for atmospheric turbulence measurements

A Doppler lidar is described, its processing methods are characterized, and two alternate techniques are considered. The described system uses a CO2 laser transmitting at 10.6 microns and a bank of narrow band filters for the spectrum analysis. Typical results obtained with this system are presented. The two alternate techniques involve computation of the discrete spectrum by use of the discrete Fourier transform. The first technique involves single-pulse processing and incoherent integration, while the second technique performs coherent processing on the train of received pulses.

Polge, R. J.↗

Fiber-optic thermometer using temperature dependent absorption, broadband detection, and time domain referencing

A fiber-optic thermometer based on temperature dependent absorption in Nd(3+) doped glass is demonstrated over the 298-573 K range. A broadband detection technique allows the use of the complete spectrum of a pulse modulated light emitting diode. A fiber-optic recirculating loop is employed to construct a reference channel in the time domain by generating a train of pulses from one initial pulse. A theoretical model is developed, and experimental data are shown to compare well with the theory. Possible sources of error and instability are identified, and ways to enhance the performance of the system are proposed.

Adamovsky, Grigory↗

NASA Report to Education, Volume 9

This is an edition of 'NASA Report to Education' covering NASA's Educational Workshop, Lewis Research Center's T-34 and the Space Exploration Initiative. The first segment shows NASA Education Workshop program (NEWEST - NASA Educational Workshops for Elementary School Teachers). Highlights of the 14 days of intense training, lectures, fieldtrips and simple projects that the educators went through to teach the program are included. Participants are shown working on various projects such as the electromagnetic spectrum, living in Space Station Freedom, experience in T-34, tour of tower at the Federal Aviation Administrative Facilities, conducting an egg survival system and an interactive video conference with astronaut Story Musgrave. Participants share impressions of the workshop. The second segment tells how Lewis Research Center's T-34 aircraft is used to promote aerospace education in several Cleveland schools and excite students.

Source record↗

Medical Decision Making in the Physician Hierarchy: A Pilot Pedagogical Evaluation

Context: Recently, The American College of Graduate Medical Education (ACGME) has included the medical decision making as a core competency in several specialties. To date, the ability to demonstrate and measure a pedagogical evolution of medical judgment in a medical education program has been limited. Objective: In this study we hope to examine differences in medical decision making ability of different physicians across their various stages of post-graduate hierarchy. Method: Physcians spanning a wide spectrum of scientific disciplines were recruited for three catagories: administrative physicians(AP) representing physcians with the most experience but mostly practice administratively; resident physicians completing their postgraduate medical training (RP) and seasoned attending physicians with mastery level experience (MP). Participants completed four medical simulations focused on abdominal pain: cholecystitis (CH) and renal colic(RC) and chest pain; Cardiac ischemia (STEMI) and pneumothorax (PX). Simulation were ordered randomly so that there was no systematic bias due to learning or to fatigue. The Medical judgment metric (MJM) was used to evaluate medical decision-making. Results: There were no significant differences between the AP, RP, and MP groups in the gender, race, ethnicity, education, and baseline heart rate. There was a significant (p=0.002) interaction effect for simulation time and RP group, 6.2 minutes (+/-1.58); MP group, 8.7 minutes (+/-2.46); and AP group, 10.3 minutes (+/-2.78). The RC MJM scores were significantly (P=0.10) worse in the AP group 12.3 (+/-2.66) then the RP 14.7(+/-1.15) and MP17.7 (+/-1.15) groups. In every simulation, the AP group MJM scores were worse on average (no significantly) compared to the MP and RP groups. The AP group was significantly (P=0.040) less likely to stabilize the subject in the RC simulation than MP and RP groups. Conclusion: There remains significant variability in the medical education and skill retention influences medical decision making throughout a physician's career.

Rosasco, John↗