Search NASA⌕ Search

SEARCH · Search NASA

Results for “squids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SQUIDs De-fluxing Using a Decaying AC Magnetic Field

Flux trapping is the Achilles’ heel of all superconductor electronics. The most direct way to avoid flux trapping is a prevention of superconductor circuits from exposure to magnetic fields. Unfortunately this is not feasible if the circuits must be exposed to a strong DC magnetic field even for a short period of time. For example, such unavoidable exposures take place in superparamagnetic relaxation measurements (SPMR) and ultra-low field magnetic resonance imaging (ULF MRI) using unshielded thin-film SQUID-based gradiometers. Unshielded SQUIDs stop working after being exposed to DC magnetic fields of only a few Gauss in strength. In this paper we present experimental results with de-fluxing of planar thin-film LTS SQUID-based gradiometers using a strong decaying AC magnetic field. We used four commercial G136 gradiometers for SPMR measurements with up to a 10 mT magnetizing field. Strong 12.9 kHz decaying magnetic field pulses reliably return SQUIDs to normal operation 50 ms after zeroing the DC magnetizing field. This new AC de-fluxing method was also successfully tested with seven other different types of LTS SQUID sensors and has been shown to dissipate extremely low energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of high field SQUID magnetometer for magnetization studies up to 7 T and temperatures in the range from 4.2 to 300 K

We present the design, fabrication, integration, testing, and calibration of a high field superconducting quantum interference device (SQUID) magnetometer. The system is based on dc SQUID sensor with flux locked loop readout electronics. The design is modular and all the subsystems have been fabricated in the form of separate modules in order to simplify the assembly and for ease of maintenance. A novel feature of the system is that the current induced in the pickup loop is distributed as inputs to two different SQUID sensors with different strengths of coupling in order to improve the dynamic range of the system. The SQUID magnetometer has been calibrated with yttrium iron garnet (YIG) sphere as a standard reference material. The calibration factor was determined by fitting the measured flux profile of the YIG sphere to that expected for a point dipole. Gd{sub 2}O{sub 3} was also used as another reference material for the calibration and the effective magnetic moment of the Gd{sup 3+} could be evaluated from the temperature dependent magnetization measurements. The sensitivity of the system has been estimated to be about 10{sup -7} emu at low magnetic fields and about 10{sup -5} emu at high magnetic fields {approx}7 T.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning SQUID susceptometers with sub-micron spatial resolution

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ{sub 0}/Hz{sup 1/2}. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogen-free variable temperature scanning SQUID microscope

Scanning Superconducting QUantum Interference Device (SQUID) microscopy is a powerful tool for imaging local magnetic properties of materials and devices, but it requires a low-vibration cryogenic environment, traditionally achieved by thermal contact with a bath of liquid helium or the mixing chamber of a “wet” dilution refrigerator. We mount a SQUID microscope on the 3 K plate of a Bluefors cryocooler and characterize its vibration spectrum by measuring SQUID noise in a region of sharp flux gradient. By implementing passive vibration isolation, we reduce relative sensor-sample vibrations to 20 nm in-plane and 15 nm out-of-plane. A variable-temperature sample stage that is thermally isolated from the SQUID sensor enables measurement at sample temperatures from 2.8 K to 110 K. We demonstrate these advances by imaging inhomogeneous diamagnetic susceptibility and vortex pinning in optimally-doped YBCO above 90 K.

47 OTHER INSTRUMENTATION↗

Measurement of SQUID noise levels for SuperCDMS SNOLAB detectors (Final Paper)

SuperCDMS SNOLAB is a second generation direct dark matter search. In the SuperCDMS SNOLAB experiment, detectors are able to pick up from signals from dark matter nuclear recoil interactions which occur inside the bulk of the detectors. These interactions produce both phonon and charge signals. HEMTs read out charge signals whereas TES are used to detect phonon signals which are then read out by SQUID amplifiers. SQUID amplifiers must add negligible noise to the TES intrinsic noise which has been previously measured and is approximately 50pA/√Hz down to 100Hz for ease of signal distinguishability in dark matter nuclear interactions. The intrinsic noise level of the SQUID was tested in the SLAC 300mK fridge and determined to provide adequately low levels of noise with a floor of approximately 3pA/√Hz. Furthermore, a 10x amplifier was tested for addition of extraneous noise. This noise was investigated with and without this amplifier, and it was found that it did not add a significant amount of noise to the intrinsic SQUID noise.

47 OTHER INSTRUMENTATION↗

SQUID Noise Measurements for CDMS Detectors

The Cryogenic Dark Matter Search is the second iteration of SuperCDMS dark matter experiments with an increase in sensitivity to low mass dark matter particles. The experiment uses germanium and silicon crystals which are capable of detecting both the charges and phonon signals produced from dark matter interactions. Detectors are housed in towers which are then housed in a cryogenics system able to cool down to 15 mK. The experiment will be installed in an underground lab in Sudbury, Ontario in order to shield from cosmic rays and background radiation. SQUIDs are an acronym for superconducting quantum interference devices that are capable of detecting extremely small magnetic fields. A typical dark matter nuclear recoil interaction can be detected by a TES (transition edge sensor). SQUIDs are then used to read out and amplify the signals generated by the TES. It is essential that these SQUIDS add negligible noise to the intrinsic noise of the TES to be able to distinguish the internal circuit noise from a true dark matter interaction signal. The noise was measured while varying several parameters. Both an Agilent and an SRS785 spectrum analyzer were used. Furthermore, an amplifier which amplified the signal 10x was tested. The Agilent machine produced more noticeably greater noise in the region from 100-1000 Hz, whereas the SRS785 did not. Next, the amplifier was tested and the signal generated was analyzed in comparison to the original signal. The amplifier did not produce any noticeable additional noise over the intrinsic noise of the SQUID. Further work includes testing to see if detectors with higher voltage sources can also be used with negligible noise.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronics for a Next-Generation SQUID-Based Time-Domain Multiplexing System

A decade has elapsed since the design, development and realization of a SQUID-based time-division multiplexer at NIST. During this time the system has been used extensively for low-temperature-detector-array measurements. Concurrently, there have been substantial advancements both in detector array and commercial electronic component technology. The relevance and applicability of the technology has blossomed as well, often accompanied by more demanding measurement requirements. These factors have motivated a complete redesign of the NIST room-temperature read-out electronics. The redesign has leveraged advancements in component technology to achieve new capabilities better suited to the SQUID multiplexers and detector arrays being realized today. As examples of specific performance enhancements, the overall system bandwidth has been increased by a factor of four (a row switching rate of 6.24 MHz), the compactness has been increased by over a factor of two (a higher number of detector columns and rows per circuit board), and there are two high speed outputs per column (allowing fast switching of SQUID offsets in addition to digital feedback). The system architecture, design implementations, and performance advantages of the new system will be discussed. As an application example, the science chain flight electronics for the Micro-X High Resolution Microcalorimeter X-ray Imaging Rocket will be described as both a motivation for, and a direct implementation of the new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication and characterization of shunted μ-SQUID

In order to eliminate hysteresis, we have fabricated and characterized niobium based shunted micron size superconducting quantum interference devices (μ-SQUIDs). We find a wide temperature range where these μ-SQUIDs are non-hysteretic in nature and show a very good I{sub c} vs. B oscillations in hysteretic regime and V vs. B oscillations in non-hysteretic regime. Here we report the characteristics of a shunted- μ-SQUID (Wf38LS72D5). In this device we have achieved a large voltage modulation, in non-hysteretic regime, at various temperatures including such as 1.1 mV at 6.62 K with a transfer function V{sub Φ} = 7.2mV/Φ{sub 0}. The figures within the original article PDF file, as supplied to AIP Publishing, were affected by a PDF-processing error. Consequently, the article re-flowed and pagination increased from 3 to 4 pages. This article was updated on 14 May 2014 to correct the PDF-processing error, with the scientific content remaining unchanged. Readers are advised that the replacement article PDF file contains an additional blank page to preserve the original pagination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging collective behavior in an rf-SQUID metamaterial tuned by DC and RF magnetic fields

In this study, we examine the collective behavior of two-dimensional nonlinear superconducting metamaterials using a non-contact spatially resolved imaging technique. The metamaterial is made up of sub-wavelength nonlinear oscillators in a strongly coupled 27x27 planar array of radio-frequency Superconducting QUantum Interference Devices (rf SQUIDs). By using low-temperature laser scanning microscopy we image microwave currents in the driven SQUIDs while in non-radiating dark modes and identify the clustering and uniformity of like-oscillating meta-atoms. We follow the rearrangement of coherent patterns due to meta-atom resonant frequency tuning as a function of external dc and rf magnetic flux bias. We find that the rf current distribution across the SQUID array at zero dc flux and small rf flux reveals a low degree of coherence. By contrast, the spatial coherence improves dramatically upon increasing of rf flux amplitude, in agreement with simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonance detection of dark matter axions using a DC SQUID

A method for detecting dark matter axions in which a dc SQUID serves as a detector is proposed. The SQUID is shown to be able to detect the magnetic field perturbations induced by its interaction with axions. The resonance signal appears as a current step in the SQUID current–voltage characteristic. The voltage of the step corresponds to the axion mass, while its height depends on the axion energy density in near-Earth space. The proposed method is aimed at detecting axions with masses m{sub a} ≲ 10{sup –4} eV, which are of interest for both cosmology and particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SQUIDs vs. Faraday coils for ultlra-low field nuclear magnetic resonance: experimental and simulation comparison

Nuclear magnetic resonance (NMR) methods are widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging or MRI. Recently it has become possible to perform NMR and MRI in ultra-low field (ULF) regime that requires measurement field strengths only of the order of 1 Gauss. These techniques exploit the advantages offered by superconducting quantum interference devices or SQUIDs. Our group at LANL has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airports security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers provide enough sensitivity in the 3-10 kHz range and can be used for fast liquid explosives detection based on ULF NMR/MRI technique. We describe an experimental and computer simulation comparison of the world's first multichannel SQUID based and Faraday coils based instruments that are capable of performing ULF MRI for liquids identification.

42 ENGINEERING↗

Low Noise Frequency-Domain Multiplexing of TES Bolometers Using SQUIDs at Sub-Kelvin Temperature

Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of transition edge sensors. DfMux has been used by several Cosmic Microwave Background experiments, including most recently POLARBEAR-2 and SPT-3 G with multiplexing factors as high as 68, and is the baseline readout technology for the planned satellite mission LiteBIRD. Here, we present recent work focused on improving DfMux readout noise, reducing parasitic impedance, and improving sensor operation. We have achieved a substantial reduction in stray impedance by integrating the sensors, resonators, and SQUID array onto a single-carrier board operated at 250 mK. This also drastically simplifies the packaging of the cryogenic components and leads to better-controlled crosstalk. We demonstrate a low readout noise level of 8.6 pA/Hz1 1/2 , which was made possible by operating the SQUID array at a reduced temperature and with a low dynamic impedance. This is a factor of two improvement compared to the achieved readout noise level in currently operating Cosmic Microwave Background experiments using DfMux and represents a critical step toward maturation of the technology for the next generation of instruments.

47 OTHER INSTRUMENTATION↗

Tuning the inductance of Josephson junction arrays without SQUIDs

It is customary to use arrays of superconducting quantum interference devices (SQUIDs) for implementing magnetic field-tunable inductors. Here, we demonstrate an equivalent tunability in a (SQUID-free) array of single Al/AlOx/Al Josephson tunnel junctions. With the proper choice of junction geometry, a perpendicularly applied magnetic field bends along the plane of the superconductor and focuses into the tunnel barrier region due to a demagnetization effect. Consequently, the Josephson inductance can be efficiently modulated by the Fraunhofer-type supercurrent interference. The elimination of SQUIDs not only simplifies the device design and fabrication but also facilitates a denser packing of junctions, and, hence, a higher inductance per unit length. As an example, we demonstrate a transmission line, the characteristic impedance of which is field-tuned in the range of 4–8 kΩ, centered around the important value of the resistance quantum h/(2e)2≈6.5 kΩ.

Physics↗

A SQUID-based microwave cavity search for dark-matter axions

Axions in the {mu}eV mass range are a plausible cold dark matter candidate and may be detected by their conversion into microwave photons in a resonant cavity immersed in a static magnetic field. The first result from such an axion search using a superconducting first-stage amplifier (SQUID) is reported. The SQUID amplifier, replacing a conventional GaAs field-effect transistor amplifier, successfully reached axion-photon coupling sensitivity in the band set by present axion models and sets the stage for a definitive axion search utilizing near quantum-limited SQUID amplifiers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SQUID magnetometry from nanometer to centimeter length scales

The development of Superconducting QUantum Interference Device (SQUID)-based magnetometer for two applications, in vivo prepolarized, ultra-low field MRI of humans and dispersive readout of SQUIDs for micro- and nano-scale magnetometery, are the focus of this thesis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Readout of X-ray Pulses from a Single-pixel TES Microcalorimeter with Microwave Multiplexer Based on SQUIDs Directly Coupled to Resonators

We have first demonstrated the cooperation between an X-ray TES and a directly coupled microwave SQUID multiplexer (D-coup. MW-Mux) in which SQUIDs are directly coupled to resonators. Using D-coup. MW-Mux, we successfully detected the X-ray pulses from a single-pixel TES and evaluated the energy resolution of 11.8 eV FWHM at 5.9 keV. We found this preliminary energy resolution is attributed to non-optimum bias point of the present TES, which can be improved by the future reduction of readout noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

A simplified HTc rf SQUID to analyze the human cardiac magnetic field

We have developed a four-channel high temperature radio-frequency superconducting quantum interference device (HT{sub c} rf SQUID) in a simple magnetically shielded room (MSR) that can be used to analyze the cardiac magnetic field. It is more robust and compact than existing systems. To achieve the high-quality magnetocardiographic signal, we explored new adaptive software gradiometry technology constructed by the first-order axial gradiometer with a baseline of 80mm, which can adjust its performance timely with the surrounding conditions. The magnetic field sensitivity of each channel was less than 100fT/√Hz in the white noise region. Especially, in the analysis of MCG signal data, we proposed the total transient mapping (TTM) technique to visualize current density map (CDM), then we focused to observe the time-varying behavior of excitation propagation and estimated the underlying currents at T wave. According to the clear 3D imaging, isomagnetic field and CDM, the position and distribution of a current source in the heart can be visualized. It is believed that our four-channel HT{sub c} rf SQUID magnetometer based on biomagnetic system is available to detect MCG signals with sufficient signal-to-noise (SNR) ratio. In addition, the CDM showed the macroscopic current activation pattern, in a way, it has established strong underpinnings for researching the cardiac microscopic movement mechanism and opening the way for its use in clinical diagnosis.

36 MATERIALS SCIENCE↗