Search NASA⌕ Search

SEARCH · Search NASA

Results for “step test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Transister step stress testing program for JANTX2N3811

The effect was studied of power/temperature step stress when applied to the dual transistor JANTX2N3811 manufactured by Motorola and National Semiconductor. A total of 48 samples from Motorola and 47 from National Semiconductor was submitted to the processes. In addition, two control sample units were maintained for verification of the electrical parametric testing. The tests for determining power/temperature stresses are described, and test results are discussed. Failure analyses for power stress, and temperature stress are presented.

Source record↗

Testing of the anemometer circuit: Data report

The following text discusses results from the electronic step testing and the beginning of velocity step testing in the shock tube. It should be kept in mind that frequency response is always measured as the time from the beginning of the event to the minimum (positive inflection) of the 'bucket' that immediately follows the response. This report is not a complete account of the results from square wave testing. Some data is still in the process of being analyzed and efforts are being made to fit the data to both Freymuth's third order theory and modelled responses from SPICE circuit simulation software.

Moen, Michael J.↗

Space Shuttle Columbia Aging Wiring Failure Analysis

A Space Shuttle Columbia main engine controller 14 AWG wire short circuited during the launch of STS-93. Post-flight examination divulged that the wire had electrically arced against the head of a nearby bolt. More extensive inspection revealed additional damage to the subject wire, and to other wires as well from the mid-body of Columbia. The shorted wire was to have been constructed from nickel-plated copper conductors surrounded by the polyimide insulation Kapton, top-coated with an aromatic polyimide resin. The wires were analyzed via scanning electron microscope (SEM), energy dispersive X-Ray spectroscopy (EDX), and electron spectroscopy for chemical analysis (ESCA); differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA) were performed on the polyimide. Exemplar testing under laboratory conditions was performed to replicate the mechanical damage characteristics evident on the failed wires. The exemplar testing included a step test, where, as the name implies, a person stepped on a simulated wire bundle that rested upon a bolt head. Likewise, a shear test that forced a bolt head and a torque tip against a wire was performed to attempt to damage the insulation and conductor. Additionally, a vibration test was performed to determine if a wire bundle would abrade when vibrated against the head of a bolt. Also, an abrasion test was undertaken to determine if the polyimide of the wire could be damaged by rubbing against convolex helical tubing. Finally, an impact test was performed to ascertain if the use of the tubing would protect the wire from the strike of a foreign object.

McDaniels, Steven J.↗

Transistor step stress testing program for JANTX2N3637

Data for the purpose of evaluating the effect of power/temperature step stress when applied to a variety of semiconductor devices are presented. The transistor JANTX2N3637 manufactured by Transitron and Motorola is studied. A total of 48 samples from Transitron and 41 samples from Motorola were submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. Results are reported.

Source record↗

Diode step stress testing program for JANTX1n5420

Data compiled for the purpose of evaluating the effect of power/temperature step stress when applied to the diode JANTX1N5420 manufactured by Unitrode and Micro-Semiconductor is presented. A total of 48 samples from each manufacturer was submitted to the processes outlined. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

Evaluation by step response tests of prototype relief valves designed for YF-12 inlet stability bleed system

Two stability bleed system relief valves were tested in a special dynamic test facility. These poppet valves are prototypes for a stability bleed system designed for use in a YF-12 flight inlet. One valve is unshielded, while the other has a special shield to eliminate the flow effect pressures on the piston. The tests determined the size of a damping orifice to be used during wind tunnel tests of the bleed system and verified an analog simulation of the valves. The effects of initial pressure level, pressure step size, and spring rate were investigated.

Dustin, M. O.↗

Development and Validation of Sensorimotor Assessment Tasks Using Spaceflight Analogs

INTRODUCTION Exploration class missions will require a new level of crew autonomy to self-assess and treat their sensorimotor dysfunction around periods of gravitational transition, where sensorimotor disturbances are at their highest. There is a need to define sensorimotor assessment thresholds that indicate when performance in early extravehicular activities (EVAs) might be impacted or unsafe. The purpose of this study was to develop and validate a set of assessment tasks using sensorimotor spaceflight analogs including the Sensorimotor Disorientation Analog (SDA) and +3G x sustained centrifugation. METHODS For the SDA, forty-one healthy non-astronaut subjects (21 males, 20 females; Mean ± SD, Age: 34.0 ± 7.8 years) volunteered to participate in this study. Subjects attended two testing sessions: 1) familiarization to the tasks and baseline data collection, and 2) tasks completed under two levels of sensorimotor disorientation. Subjects performed a series of seven sensorimotor assessment tasks followed by two operationally relevant EVA analog tasks. The sensorimotor assessments tasks, ordered from least to most provocative of the sensorimotor system, included: postural stability, step test, prone/supine recovery from fall (RFF), four-square-step-test, obstacle negotiation with turns (OTT), kneel-and-reach, and augmented reality full-body coordination. The operational analog tasks included a top-hatch capsule egress and a 5-minute EVA traversal. Disorientation was applied via the SDA which utilized galvanic vestibular stimulation and weighted trunk, wrists, and ankles to target the vestibular and proprioceptive systems such that performance while wearing the SDA mimicked astronaut postflight performance at R+0 and R+1. Sixteen healthy non-astronaut subjects (10 males, 6 females; Age: 35.0 ± 9.5 years) completed +3G x 60-minute sustained centrifugation as an established spaceflight analog replicating the vestibular disruptions seen postflight. Subjects completed a pre-session which included familiarization to the tasks and a 5-minute centrifuge spin. The data collection session included, in order, a baseline data collection, 60-minute centrifuge spin, immediate post-centrifuge data collection, 45-minute seated recovery, and a final data collection. The same assessment and operational analog tasks were conducted as described above. RESULTS Pearsons’ correlation r-values were calculated between assessment and operational analog tasks. The two assessment tasks with the strongest correlations to the operational analog tasks were the RFF (SDA: r≥ 0.57, Centrifuge: r ≥0.55) and OTT (SDA: r≥ 0.66, Centrifuge: r ≥ 0.49). For brevity, repeated measures ANOVA with follow-up paired t-tests are discussed for these two assessment tasks. The SDA found significant differences between all three levels of disorientation for both RFF and OTT (p < 0.001). Significant differences were also found between baseline and immediate post centrifuge testing for both the RFF (p≤ 0.011) and OTT (p = 0.001). Additional results are forthcoming for both disorientation paradigms. DISCUSSION These validation studies provide evidence for down-selection of the assessment tasks that were able to distinguish between levels of sensorimotor disorientation and correlate to performance in operationally relevant tasks for use in upcoming Artemis missions.

S C Moudy↗

Optic Flow Dominates Visual Scene Polarity in Causing Adaptive Modification of Locomotor Trajectory

Locomotion and posture are influenced and controlled by vestibular, visual and somatosensory information. Optic flow and scene polarity are two characteristics of a visual scene that have been identified as being critical in how they affect perceived body orientation and self-motion. The goal of this study was to determine the role of optic flow and visual scene polarity on adaptive modification in locomotor trajectory. Two computer-generated virtual reality scenes were shown to subjects during 20 minutes of treadmill walking. One scene was a highly polarized scene while the other was composed of objects displayed in a non-polarized fashion. Both virtual scenes depicted constant rate self-motion equivalent to walking counterclockwise around the perimeter of a room. Subjects performed Stepping Tests blindfolded before and after scene exposure to assess adaptive changes in locomotor trajectory. Subjects showed a significant difference in heading direction, between pre and post adaptation stepping tests, when exposed to either scene during treadmill walking. However, there was no significant difference in the subjects heading direction between the two visual scene polarity conditions. Therefore, it was inferred from these data that optic flow has a greater role than visual polarity in influencing adaptive locomotor function.

Nomura, Y.↗

Optic Flow Dominates Visual Scene Polarity in Causing Adaptive Modification of Locomotor Trajectory

Locomotion and posture are influenced and controlled by vestibular, visual and somatosensory information. Optic flow and scene polarity are two characteristics of a visual scene that have been identified as being critical in how they affect perceived body orientation and self-motion. The goal of this study was to determine the role of optic flow and visual scene polarity on adaptive modification in locomotor trajectory. Two computer-generated virtual reality scenes were shown to subjects during 20 minutes of treadmill walking. One scene was a highly polarized scene while the other was composed of objects displayed in a non-polarized fashion. Both virtual scenes depicted constant rate self-motion equivalent to walking counterclockwise around the perimeter of a room. Subjects performed Stepping Tests blindfolded before and after scene exposure to assess adaptive changes in locomotor trajectory. Subjects showed a significant difference in heading direction, between pre and post adaptation stepping tests, when exposed to either scene during treadmill walking. However, there was no significant difference in the subjects heading direction between the two visual scene polarity conditions. Therefore, it was inferred from these data that optic flow has a greater role than visual polarity in influencing adaptive locomotor function.

Nomura, Y.↗

Semiconductor step-stress testing

Report describes extensive program to test behavior of discrete diodes and transistors subjected to power and temperature overstress. Commercially available bipolar and field effect transistors and diodes were stressed between 0.5 and 1.75 times maximum rated power. Two groups were temperature stressed: 160 hour steps starting at 75 C to maximum of 300 C. Cumulative failures and changes in device parameters were monitored and reasons for failures presented.

Source record↗

Semiconductor step-stress testing

Report documents behavior of discrete diodes and transistors in extensive power and temperature overstress tests. Thirty nine devices were tested in groups designated: (1) power overstress, and (2) and (3) temperature overstress. Results are of interest to users of tested components and engineers in conduction of similar tests.

Meeks, H. B.↗

Space Active Modular Materials Experiments (SAMMES): Low Earth Orbital mission aboard the Space Test Experiments STEP-3 platform

The requirement of satellite systems to survive in the space environment for 5 to 10 years to achieve greater cost effectiveness is discussed. Characterization of the orbital space environment and its effects on spacecraft systems have received considerable research attention. Instrumentation for long term measurement of key physical parameters characterizing the low Earth orbit (LEO) environment and its effects on degradation of spacecraft materials and solar arrays is reported. These measurements enable active, real time monitoring of the health of spacecraft and payload systems. SAMMES is designed to be autonomous, compact, low power, and lightweight.

Joshi, P.↗

Neuro-Vestibular Examination During and Following Spaceflight (Vestibular Health)

BACKGROUND Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances could include space motion sickness, spatial disorientation, and cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflexes, and control of posture and locomotion. Otolith-mediated reflex gains appear to adapt rapidly during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex. OBJECTIVES We will investigate temporal vestibular changes in crewmembers of short, 6-month, and one-year missions to identify trends in adaptation of vestibular health and performance in orbit and after landing. We will also determine whether the vestibular organs and/or the central vestibular system undergo structural changes during long-duration exposure to microgravity, which could cause vestibular disorders when transitioning to a different gravitational environment. METHODS Recordings of eye, head, and body movements, as well as subjective reports of perception of motion, will be used to determine the presence of abnormal eye movements, dysmetria, motion sickness symptoms, and illusions of motion during head or body movements. This includes characterization of temporal trends in central compensation for vestibular (otolith) asymmetry. Pre-flight data will be collected 90 days before the flight. In-flight tests will be performed early in the mission and once every one or two months thereafter. Post-flight examinations will be performed on the following days after return (R) from the mission: R+0, R+4, R+9, and R+30. Ground-based control tests will be performed on healthy volunteers in the laboratory to estimate mean normative responses. CONTROL RESULTS Thirty-two healthy (non-astronaut) control subjects performed the same ground test procedures as planned for crewmembers. In addition to establishing a normative database, these data were used to calculate vestibular asymmetries from perceptual reports during unilateral centrifugation, oculomotor responses during visual-alignment tasks, vestibulo-ocular reflex gain during head-impulse tests, and body rotation during stepping tests. A significant correlation was observed between asymmetries of subjective visual vertical and verbal report during unilateral centrifugation. Another significant correlation was observed between the asymmetries of ocular alignment, vestibulo-ocular reflex gain, and body rotation. These findings in a healthy cohort may help us better understand changes in vestibular asymmetries in crewmembers during and following spaceflight. RELEVANCE If the observed symptoms in crewmembers are more deleterious after the year-long missions than those documented after 6-month missions, then relevant countermeasures will be required to maintain the health and operational performance of astronauts during longer missions. Depending on the etiology of the vestibular syndrome revealed by these tests, countermeasures will be proposed based on vestibular rehabilitation therapies currently used in patients with vestibular disorders, such as habituation, gaze stabilization, and/or balance training exercises. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element.

T R Macaulay↗

Testing and Analysis of Composite Skin/Stringer Debonding Under Multi-Axial Loading

A consistent step-wise approach is presented to investigate the damage mechanism in composite bonded skin/stringer constructions under uniaxial and biaxial (in-plane/out-of-plane) loading conditions. The approach uses experiments to detect the failure mechanism, computational stress analysis to determine the location of first matrix cracking and computational fracture mechanics to investigate the potential for delamination growth. In a first step, tests were performed on specimens, which consisted of a tapered composite flange, representing a stringer or frame, bonded onto a composite skin. Tests were performed under monotonic loading conditions in tension, three-point bending, and combined tension/bending to evaluate the debonding mechanisms between the skin and the bonded stringer. For combined tension/bending testing, a unique servohydraulic load frame was used that was capable of applying both in-plane tension and out-of-plane bending loads simultaneously. Specimen edges were examined on the microscope to document the damage occurrence and to identify typical damage patterns. For all three load cases, observed failure initiated in the flange, near the flange tip, causing the flange to almost fully debond from skin. In a second step, a two dimensional plane-strain finite element model was developed to analyze the different test cases using a geometrically nonlinear solution. For all three loading conditions, computed principal stresses exceeded the transverse strength of the material in those areas of the flange where the matrix cracks had developed during the tests. In a third step, delaminations of various lengths were simulated in two locations where delaminations were observed during the tests. The analyses showed that at the loads corresponding to matrix ply crack initiation computed strain energy release rates exceeded the values obtained from a mixed mode failure criterion in one location, Hence. Unstable delamination propagation is likely to occur as observed in the experiments.

Krueger, Ronald↗

Testing and Analysis of Composite Skin/Stringer Debonding under Multi-Axial Loading

A consistent step-wise approach is presented to investigate the damage mechanism in composite bonded skin/stringer constructions under uniaxial and biaxial (in-plane/out-of-plane) loading conditions. The approach uses experiments to detect the failure mechanism, computational stress analysis to determine the location of first matrix cracking and computational fracture mechanics to investigate the potential for delamination growth. In a first step, tests were performed on specimens, which consisted of a tapered composite flange, representing a stringer or frame, bonded onto a composite skin. Tests were performed under monotonic loading conditions in tension, three-point bending, and combined tension/bending to evaluate the debonding mechanisms between the skin and the bonded stringer. For combined tension/bending testing, a unique servohydraulic load frame was used that was capable of applying both in-plane tension and out-of-plane bending loads simultaneously. Specimen edges were examined on the microscope to document the damage occurrence and to identify typical damage patterns. For all three load cases, observed failure initiated in the flange, near the flange tip, causing the flange to almost fully debond from the skin. In a second step, a two-dimensional plane-strain finite element model was developed to analyze the different test cases using a geometrically nonlinear solution. For all three loading conditions, computed principal stresses exceeded the transverse strength of the material in those areas of the flange where the matrix cracks had developed during the tests. In a third step, delaminations of various lengths were simulated in two locations where delaminations were observed during the tests. The analyses showed that at the loads corresponding to matrix ply crack initiation computed strain energy release rates exceeded the values obtained from a mixed mode failure criterion in one location. Hence, unstable delamination propagation is likely to occur as observed in the experiments.

Krueger, Ronald↗

The STEP mission - Satellite test of the equivalence principle

The STEP experiment is a joint ESA/NASA mission candidate for selection as the next medium science project in the ESA scientific program. ESA and NASA have undertaken a joint feasibility study of STEP. The principles of STEP and details of the mission are presented and the mission and spacecraft are described. The primary objective of STEP is to measure differences in the rate of fall of test masses of different compositions to one part in 10 exp 17 of the total gravitational acceleration, a factor of 10 exp 8 improvement in sensitivity over previous experiments. STEP constitutes a comparison of gravitational and inertial mass or a test of the weak equivalence principle (WEP). A test of WEP that is six orders of magnitude more accurate than previous tests will reveal whether the underlying structure of the universe is filled with undiscovered small forces, necessitating a fundamental change in our theories of matter on all scales.

Atzei, A.↗