Search NASA⌕ Search

SEARCH · Search NASA

Results for “step test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

New insights on carbon black suspension rheology—Anisotropic thixotropy and antithixotropy

We report a detailed experimental study of peculiar thixotropic dynamics of carbon black (CB, Vulcan XC-72) suspensions in mineral oil, specifically the observation of sequential stress increase then decrease at a fixed shear rate in a step-down test. We verify that such dynamics, though peculiar, come from a true material response rather than experimental artifacts. We also reveal how this long-time stress decay is associated with antithixotropic structural change rather than viscoelastic stress relaxation by using orthogonal superposition (OSP) rheometry to probe viscoelastic moduli during the step-down tests. The orthogonal storage and loss moduli are present, showing this two-timescale recovery then decay response, which demonstrates that this response is antithixotropic, and it involves shear-induced structuring. We further show a mechanical anisotropy in the CB suspension under shear using OSP. Based on the rheological results, a microstructural schematic is proposed, considering qualitatively thixotropic structure build-up, antithixotropic densification, and anisotropic structure evolution. Our observation for these CB suspensions is outside the standard paradigm of thixotropic structure-parameter models, and the elastic response provides us with new insight into the transient dynamics of CB suspensions.

Mechanics↗

A Graphical User Interface for the Deep Underground Neutrino Experiment Robotic Test Stand

In preparation for DUNE, Fermilab along with six other institutions are testing cold electronics for quality control before components placed in the far detector. We test them by using a robotic arm that places these chips into sockets on a computer board that will test their functionality. Up until now, the chips have been tested using a command line script that drives a state machine to conduct tests step-by-step. In order to lower the skill barrier to conduct tests and to speed up the quality control process, I was tasked to create a graphical user interface that would allow users to use buttons, text boxes, and drop-down menus to input information and tell the testing state machine how to operate. I had to learn about the Python package Tkinter to start the process of widget placement. I further developed a pause feature unused in the previous command line script that would allow the user to shut down testing gracefully, bring the robotic arm to go back to ground state, and go forward or backward a step in the testing process. After completing the basic functionality of the GUI, I started testing production chips with the GUI to debug. Some issues were found, which required me to further develop parts of the inherited state machine code. The code for the GUI has now been pushed into the copy the DUNE/FD_CE git repository and will soon be merged with the official DUNE/FD_CE repository so that the other institutions testing DUNE cold electronics can use and expand upon it.

Gutierrez Villanueva, Jaziel [Fermilab]↗

In-Situ Stress Measurements at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

A scientific injection campaign was conducted at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site in 2017 and 2019. The testing included pump-in/shut-in, pump-in/flowback, and step rate tests. Various methods have been employed to interpret the in-situ stress from the test dataset. This study focuses on methods to interpret the minimum in-situ stress from step rate, pump-in/extended shut-in tests data obtained during the stimulation of two zones in Well 58-32. This well was drilled in low-permeability granitoid. A temperature of 199 °C was recorded at the well’s total depth of 2297 m relative to the rotary Kelly bushing (RKB). The lower zone (Zone 1) consisted of 46 m of the openhole at the toe of the well. Fractures in the upper zone (Zone 2) were stimulated between 2123–2126 m measured depths (MD) behind the casing. The closure stress gradient variation depended on the depth and the injection chronology. The closure stress was found to increase with the pumping rate/volume. This stress variation could indicate that poroelastic effects (“back stress”) and the presence of adjacent natural fractures may play an important role in the interpretation of fracture closure stress. Further, progressively increasing local total stresses may, consequently, have practical applications when moderate volumes of fluid are injected in a naturally fractured or high-temperature reservoir. The alternative techniques that use pump-in/flowback tests and temperature signatures provide a valuable perspective view of the in-situ stress measurements.

15 GEOTHERMAL ENERGY↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Wells RWM 6 and RWM 7

Hydrologic tests were conducted on the Lost Lake Aquifer Zone (LLAZ) at recovery wells RWM 6 and RWM 7 in accordance with the approved test plan (Dixon, 2023). The objective of the testing was to determine well performance parameters of RWM 6 and aquifer hydraulic properties near RWM 6 and RWM 7. Tests at RWM 6 consisted of a step-drawdown test to determine well performance parameters, a constant rate pump test to determine aquifer hydraulic properties, and an aquifer recovery test also used to determine aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. Prior to testing at RWM 6, a constant rate pump test was conducted at RWM 7. Data from this testing was used to determine aquifer hydraulic properties near RWM 7.

42 ENGINEERING↗

Iodine Capture Studies of Silver Mordenite and Novel Alternative Metal Sorbents

Radioiodine is one of the radionuclides of concern when considering reprocessing of used nuclear fuel (UNF). It is expected to be released primarily in the dissolver off-gas (DOG) stream. Sorbents that target I 2 removal from a UNF processing off gas must perform efficiently under elevated temperatures in the presence of water vapor and nitrogen oxide gasses (NOx). Many studies have been conducted that examine the adsorption of iodine species in the presence of NOx gases through reduced silver-exchanged mordenite (Ag 0 Z), a zeolite mineral. This study characterizes the effects of iodine, water vapor, and nitrogen dioxide on the adsorption of I 2 by Ag 0 Z at lower temperatures suitable for comparison with novel Cu- and Bi- bearing sorbents which offer a non-RCRA alternative. When exposed to ‘harsh’ conditions such as I 2 , H 2 O, and NO 2 vapors carried by air, Cu 2 S-polyacrylonitrile (PAN) is more efficient than Ag 0 Z and all other novel sorbents, providing with 11% I capture efficiency. However, under ‘ideal’ conditions in which I 2 is carried by dry air), Ag 0 Z is more efficient than Cu 2 S-PAN and other novel sorbents, providing 74% I capture efficiency. To investigate this result and the overall performance of all sorbents tested, several characterization techniques were employed, including thermal gravimetric analysis, scanning electron microscopy – electron dispersion X-Ray spectroscopy, powder X-ray diffraction, and X-ray photoelectron spectroscopy. These techniques are discussed within this report. This document also includes a design and test plan update from Idaho National Laboratory as the next step in testing the high performing sorbents from thin-bed tests carried out by Oak Ridge National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerated Creep Testing of Inconel 718 Using the Stepped Isostress Method (SSM)

This paper demonstrates the stepped isostress method (SSM); an accelerated creep test (ACT) for the rapid assessment of metallic materials. The SSM test is based on the time-temperature-stress superposition principle (TTSSP) where temperature and/or stress are step increased to accelerate the time-to-rupture. The SSM test has proven successful for the ACT of polymers and polymeric composites but has yet to be proven for metallic materials. In this study, new test matrix design rules for the SSM of metals are established based on deformation mechanism, time-temperature transformation, and time-temperature precipitation maps. A test matrix of SSM and conventional creep tests (CCTs) are executed for alloy Inconel 718 at 750°C (1382°F) with stress levels ranging from 100 to 350 MPa. Validation CCT data is gathered from the Japan National Institute of Material Science (NIMS). Material constants for the Sine-hyperbolic (Sinh) constitutive model are calibrated using the SSM data and employed to predict the conventional creep response. Here, when blindly compared to the CCT data, the SSM calibrated Sinh model can accurately predict the conventional creep response across logarithmic decades and thus accelerate the capture of conventional creep data. Fractography indicates ductile fracture by transgranular microvoid coalescence (TMVC) with the same fracture mode observed in both SSM and CCT specimens. Creep cavitation is indicated by the population, smoothness, and size of microvoids.

36 MATERIALS SCIENCE↗

Design and Evaluation of a Model-Free Frequency Control Strategy in Islanded Microgrids with Power-Hardware-in-the-Loop Testing

The deterioration of inertial and primary frequency response of islanded microgrids has been a crucial issue for the proper operation of such microgrids. Several approaches, including inertia emulation strategies, have been proposed to improve the primary frequency response. However, the demonstrations of most inertia emulation research works are based on simulation-only testing which hinder their applicability in the field. In this paper, a novel model-free control (MFC) strategy for frequency response support in a diesel-wind microgrid system is presented, and it is tested for evaluation using a power-hardware-in-the-Ioop (PHIL) platform. The PHIL testing is one step closer to field testing since it allows real-time verification and accounts for the nonlinear grid dynamics, noise, and time delays that are usually ignored in simulation-only environments. The proposed MFC strategy is fully distributed, has low computational requirements, and can be easily implemented in resource constrained devices such as smart inverters. A PHIL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed MFC strategy.

Ferrari Maglia, Max↗

Thermal Stimulation and Injectivity Testing at Raft River, ID EGS Site

The Raft River geothermal field is the site of an innovative Department of Energy Enhanced Geothermal System (EGS) project to determine the viability of using combined thermal and hydraulic stimulation techniques to improve energy production. Well RRG-9 is currently undergoing a stimulation program using injectate from the US Geothermal Raft River Power Plant and cold water from a cooling tower make-up water well. The stimulation began on 13 June 2013 with injection from the power plant at a temperature of about 39 °C and a pressure of 275 psig. Next, two positive displacement plunger type pumps were used to increase the injection pressure and flow rate for about one month. The highest rate achieved was 258 gpm at a pressure of 741 psig. During this time, fluid from the cooler water well was injected for about 2 weeks at various pressures. Then, the pumps were removed and plant injection resumed on 25 September. Plant injection will continue until the spring of 2014, when a high pressure hydraulic stimulation will be conducted. A series of seismic monitoring stations deployed around the well are providing data on seismic events occurring at the site. Over the past year, 51 microseismic events have been recorded, all less than Magnitude 1. During injection, several diagnostic tests were conducted to gain a better understanding of the well and reservoir. A step-rate test was performed on 22 August to measure the in-situ stress and aid in modeling in-situ fractures. A tracer was injected into the well on 9 September. No tracer was detected in adjacent production wells after several months. A second borehole televiewer survey was conducted for comparison to pre-stimulation images. Here, a third borehole televiewer survey is planned after the high pressure stimulation. Injection test data is evaluated in real time. A modified Hall plot analysis indicates the effective permeability is increasing. The injectivity index supports the results of the modified Hall plot analysis. As the thermal stimulation has continued, the injectivity index has consistently followed an upward trend from 0.1 gpm/psi to 0.53 gpm/psi.

enhanced geothermal systems↗

Extended Low Load Boiler Operation to Improve Performance and Economics of an Existing Coal Fired Power Plant (Final Report)

The overall goal is to improve the performance and economics of existing coal fired power plants by extending low load boiler operation to lower loads than is currently achievable. The objective of this program is to develop and validate sensor hardware and analytical algorithms to lower plant operating expenses (OPEX) for the currently operating pulverized coal utility boiler fleet. Coal fired utility boilers are increasingly under grid dispatch pressure. In some cases, the coal fired cost of generation is noncompetitive with respect to natural gas generation and subsidized renewable sources. To remain profitable and remain fully compliant with existing environmental regulations, the installed coal fired fleet must find technologies which allow it to move into a more flexible cyclic load dispatch model. Today the installed coal fired utility fleet must be cost of generation competitive, fully emissions compliant, and responsive to the variability inherent in renewable energy generation sources. In the Phase I of the project, GE Steam Power, Inc. (GE) performed modeling of different operating scenarios for low load operation using an existing full plant dynamic model developed for a 660MW steam power plant. Sensors and analytic algorithms to enable a stable and steady coal supply for low load pulverizer operation were identified and tested at the Pulverizer Development Facility (PDF) at GE’s Clean Energy Center in Bloomfield, Connecticut. Sensors and analytic algorithms to enable stable combustion for low load operation were identified and tested at the 15 MWth Industrial Scale Burner facility (ISBF) at GE’s Clean Energy Center. A concept was developed to test the sensors and control algorithms, down selected after testing, at a full-scale coal fired power plant. A budget estimate was then developed, and the concept was implemented at an existing utility power plant. The specific objectives of the experimental work were to: • Identify and select sensors and analytic algorithms for monitoring coal pulverizer operation at lower loads to provide stable operation and appropriate coal fineness at lower coal throughput; Identify and select sensors and analytic algorithms for a Boiler Flame Stability Monitor to better balance air and fuel at each burner. This enables a reduction in a coal boiler’s safe low load power level while maintaining stable flame characteristics; Develop a concept in Phase I for low load operation of a full-scale power plant and develop a budget estimate for testing and execute the test plan at an existing plant in Phase II; Validate the capability of the extended low load boiler system to extend the minimum load operating point in a safe and reliable manner on an existing full-scale utility boiler. At the completion of this experimental study, GE has developed a set of sensors and analytic algorithms, down selected after testing, that have the potential to enable safe low load operation of a utility boiler. GE has also identified a host site for testing these identified sensors and analytic algorithms. GE has generated a full set of deliverables that provide sufficient information to proceed with the next step of testing at a host site. This includes a potential host site and budget estimate for concept testing at host site. In the Phase II of the project, a series of field tests were completed to validate the extended low load boiler operation, which consisted of detailed engineering, installation, commissioning, and testing the additional sensors and analytics for the coal-fired combustion system on an existing full-scale utility boiler. The optimization work has been supported by the host plant and endorsed by their engineering and operation staff.

01 COAL, LIGNITE, AND PEAT↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Design and Experimental Demonstration of an Additive Manufactured Smart Oxy-Methane Burner for High Pressure and Supercritical Combustion

Pressurized oxy combustion-based systems can improve efficiency by recovering latent heat of the steam in the Flue Gas and achieving 90% CO2 capture. In addition, the novel Directly Heated Supercritical Carbon Dioxide (DH-SCO2) power cycles can achieve high thermal efficiencies and provide nearly full carbon capture. Additionally, due to the reduction of flue gas at higher pressure, smaller system size and capital cost reductions are also possible. Recent thermodynamic analysis of the DH-SCO2 cycle performed by the UTEP research team shows that combustion conditions in the vicinity of 300 bar pressure and 1000-1400 K temperature allow for relatively high system efficiencies while operating within the limit of available combustor materials. However, the realization of a directly heated supercritical power cycle requires combustion systems to operate in supercritical conditions and at temperature far below the blowout limit of conventional flames (above 1500 K). The thermodynamic properties along with the combustion properties and kinetics are unexplored at such conditions. Additionally, the interaction of the supercritical environment with energy components is also unknown. High-pressure combustion tests are performed using a smart burner at some intermediate pressure ranges (<20 bar) to help minimize these knowledge gaps. The knowledge obtained from the high-pressure test will assist in understanding the combustion chamber pressurization mechanism, ignition and flame behavior at the elevated pressure. The obtained data will act as a systematic first step in testing at higher pressures of 100 and 300 bar pressures.The primary purpose of this Dissertation is to demonstrate the operability of a low NOx smart burner for oxy-methane combustion at high pressure (< 20 bar) and scalable up to supercritical conditions. A shear co-axial smart burner is designed with a real-time temperature monitoring capability to understand the burner face interaction at high-pressure conditions. In addition, the burner has four independent injection ports to allow the independent injection of fuel and dilution gases in the combustor. The maximum operating capability of the burner is 575 kWth. The burner was fabricated using a Laser Powder Bed Fusion process with Nickel Alloy 718. A powder removal technology was invented comprising ultrasonic vibration, liquid nitrogen exposure and media blasting to remove powders from internal channels of the burner. The burner operability tests are performed in the high-pressure combustor and the swirl combustor. The high-pressure combustor was used to investigate the burner operability and thermal soak back at different pressurized conditions. The experimental tests in high-pressure combustor up to 275 kWth input resulted in 16.5 bar chamber pressure and 198°C thermal soaks back to the burner. The burner was capable of providing the required thermal input within a 3% deviation range. In addition, soot formation occurred at high-pressure tests. The swirl combustor was used to observe the flame stability of the burner. Flame lift-off was observed for jet velocities above 450 m/s. Additionally, lift-off decreased for low co-flow velocities. CO2 dilution experiments showed increased flame instabilities for all conditions above 50% dilution ratios. At lower thermal inputs, partial flame blow-offs occurred for dilution ratios above 50%. All conditions significantly reduced the flame temperature and increased the flame lift-off height. Finally, a 2nd generation AM smart burner was designed using the knowledge from the 1st generation burner experiments. The 2nd generation burner incorporated two sets of swirlers with 0.9 swirl no. A cooling system was also designed for long-duration tests at higher pressures. The thermal input and division of the burner's power are kept the same as the 1st generation burner. The burner is to be fabricated using nickel-alloy 718 for high-pressure handling capability. The design can sustain at high-pressure conditions up to 100 bar.

Islam, Md Nawshad Arslan↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable, legacy aluminum back surface field (Al-BSF) cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60deg C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission (IEC) Technical Specification 62804-1; 70 deg C/70% RH for 200 h; and 85 deg C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage (I-V) curve tracing. Final characterizations included: Suns-Voc; spatial mapping of external quantum efficiency (EQE); high-resolution photoluminescence (PL), EL, and dark lock-in thermography (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline-corrosion and -delamination as well as other concurrent degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Insights into the hydro-mechanical behavior of a decimeter-scale fracture using the mini-SIMFIP probe

ABSTRACT: Understanding hydro-mechanical couplings in fractured rocks is essential for predicting the rock mass response during high-pressure fluid injection, including the stimulation of enhanced geothermal systems. However, fluid-driven fracture dislocations are challenging to measure due to the need for local displacement data at high fluid pressures. In this study, fluid-driven displacement across a decimeter-scale laboratory fracture was investigated using the mini-SIMFIP (step rate injection method for fracture in-situ properties) probe, which is a smaller version of the SIMFIP tool (Guglielmi et al., 2014). The mini-SIMFIP probe is able to resolve the full 3D displacement vector of a fracture. The probe was installed in one of two boreholes across a decimeter-scale saw-cut granite fracture. Two pressure step injection tests were conducted under the same isotropic stress conditions. By varying injection between the boreholes, we estimated the aperture profile across the fracture. The results show a consistent pressure-dependent opening as long as steady-state flow was maintained. At a certain pressure step, steady-state conditions were no longer achievable and the fracture opened rapidly. The pressure-opening relationship diverged between the two tests and indicated a homogenization of the aperture profile and an increase in the non-linearity of the flow regime.

Osten, J↗

Estimating perturbed stress from 3-D borehole displacements induced by fluid injection in fractured or faulted shales

SUMMARY Hydrofracturing stress measurements in fractured and anisotropic shales are notoriously difficult, because opening of existing geological features tends to prevent the creation of a pure hydraulic fracture perpendicular to the least compressive principal stress. Here we show how adding 3-D borehole-displacement measurements while conducting the hydraulic injection test helps to better constrain the principal stress orientations and magnitudes. We developed a 3-D fully coupled hydromechanical numerical model to analyse the displacement, fluid pressure and injection flow-rate data measured during an injection pressure-step-rate test conducted to activate a faulted borehole interval in the Mont Terri Opalinus Clay (Switzerland). We find that injected fluids can only penetrate the fault when it is at or above the Coulomb failure pressure. Borehole displacement orientations are sensitive to a ∼15° variation in the stress–tensor orientation and a 1 MPa stress magnitude variation. Although some dispersion occurs while rupture is propagating along the fault plane ∼4 m away from the borehole, the maximum density of displacement orientations consistently informs about the stress orientation. Thus, an extended injection step-rate approach coupled with an accurate in situ measurement of the borehole wall displacements can be used to better constrain the local stress field perturbations in fractured shales and in heterogeneous rock in general.

Guglielmi, Yves↗

Reactions during conversion of simplified low-activity waste glass feeds

The mechanisms that affect the incorporation of 99Tc, a volatile radioactive component of concern, into glass melt during vitrification of low-activity waste (LAW) are being investigated to develop the method to increase the retention of 99Tc in glass waste form. Previous studies with simulated LAW glass feeds (slurry mixture of liquid waste and chemical/mineral additives) demonstrated that the early stage feed-to-glass conversion reactions below 800°C are critical for the Re (used as a nonradioactive surrogate of 99Tc) retention in glass. To examine the effect of feed composition on the feed-to-glass conversion reactions, simplified systems containing major LAW components (NaNO3 and NaOH) and representative additive components (SiO2 and H3BO3) were designed and tested. The ratio of H3BO3 to NaNO3 was varied in three-component system without NaOH and that of NaOH to NaNO3 was varied in the four-component system at a fixed H3BO3 to NaNO3 ratio. As a first step of testing with simplified feeds, this study applied thermal analyses and phase characterization of the reacting feeds, which were performed without the addition of Re, to investigate the evolution of salt phases during slurry drying process and upon heating of dried feeds.

Jin, Tongan↗

Utah FORGE 5-2428: Coupled Investigation of Fracture Permeability Impact on Reservoir Stress and Seismic Slip - 2024 Annual Workshop Presentation

This is a presentation on the Coupled Investigation of Fracture Permeability Impact on Reservoir Stress and Seismic Slip Behavior by Lawrence Livermore National Laboratory, presented by Kayla Kroll. This presentation addresses testing and modelling related to the dependency of EGS production on sustained permeability and sufficient fluid flow through pre-existing or induced fractures in hot rock. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 13, 2024.

15 GEOTHERMAL ENERGY↗

The EGS Collab project: Outcomes and lessons learned from hydraulic fracture stimulations in crystalline rock at 1.25 and 1.5 km depth

With the goal of better understanding stimulation in crystalline rock for improving enhanced geothermal systems (EGS), the EGS Collab Project performed a series of stimulations and flow tests at 1.25 and 1.5 km depths. The tests were performed in two well-instrumented testbeds in the Sanford Underground Research Facility in Lead, South Dakota, United States. The testbed for Experiment 1 at 1.5 km depth contained two open wells for injection and production and six instrumented monitoring wells surrounding the targeted stimulation zone. Four multi-step stimulation tests targeting hydraulic fracturing and nearly year-long ambient temperature and chilled water flow tests were performed in Experiment 1. The testbed for Experiments 2 and 3 was at 1.25 km depth and contained five open wells in an outwardly fanning five-spot pattern and two fans of well-instrumented monitoring wells surrounding the targeted stimulation zone. Experiment 2 targeted shear stimulation, and Experiment 3 targeted low-flow, high-flow, and oscillating pressure stimulation strategies. Hydraulic fracturing was successful in Experiments 1 and 3 in generating a connected system wherein injected water could be collected. However, the resulting flow was distributed dynamically, and not entirely collected at the anticipated production well. Thermal breakthrough was not observed in the production well, but that could have been masked by the Joule-Thomson effect. Shear stimulation in Experiment 2 did not occur - despite attempting to pressurize the fractures most likely to shear - because of the inability to inject water into a mostly-healed fracture, and the low shear-to-normal stress ratio. The EGS Collab experiments are described to provide a background for lessons learned on topics including induced seismicity, the correlation between seismicity and permeability, distributed and dynamic flow systems, thermoelastic and pressure effects, shear stimulation, local geology, thermal breakthrough, monitoring stimulation, grouting boreholes, modeling, and system management.

15 - GEOTHERMAL ENERGY↗

Controlled Pyrolysis: A Robust Scalable Composite Recycling Technology

The reinforced composites industry is facing significant challenges in handling the scrap composite material from automobile manufacturing, the wind turbine industry, and others. The fibers in the material, whether they be carbon, glass, or other materials have commercial value if they can be recovered successfully. Successfully means the fibers are clean with no sizing or other binders and have adequate strength and physical properties that would allow them to be economically reprocessed into valuable product. The composites recycling project was an industry-collaborative effort to develop a composite recycling technology using controlled pyrolysis. Through the recycling of scrap and end-of-life (EOL) cured composite materials, this pilot study was intended to create a business case by realizing a cost-effective means for recycling EOL and production scrap composite materials, ultimately reducing the volume of composite materials destined for landfill. The project was led by the Institute for Advanced Composites Manufacturing Innovation (IACMI), the American Composites Manufacturers Association (ACMA), Oak Ridge National Laboratory (ORNL), Continental Structural Plastics (CSP) a Teijin Group Company, CHZ Technologies, and A. Schulman with support from Owens Corning, John Deere, General Electric (GE), Ashland LLC, and Plastics Europe (CEFIC). The team studied and tested CHZ Technologies’ controlled pyrolysis system, known as the Thermolyzer TM , which operates on a scalable basis to convert organic polymer materials into a clean synthesis gas and char containing the recoverable carbon and glass fiber reinforcement. The recoverable energy contained in the input polymers creates the synthesis gas that can be used to provide heat to the Thermolyzer TM primary reactor in a sustainable manner. That is, once the Thermolyzer TM is started with a small amount of external natural gas, the synthesis gas that is created from the polymers will continue to operate the burners so long as feedstock is supplied. The reinforcing fiber materials remaining in the solid phase char were separated and cleaned for re-use in other polymer systems based on the retained properties of the fibers. The study created reports (attached in the appendix) on the Mass and Energy Balances, syngas analytics, VOC assessment, yield analysis and other analytics necessary for a Techno-Economic Analysis (TEA) to quantify the economic impact of the recovery and sustainable re-use of the carbon and glass fibers. The process consisted of 4 steps: Selection of 4 samples of cured composite waste materials from project partners interested in materials recycling and recovering the reinforcing fibers for best case re-use. The materials included glass fiber (GF) polyester/vinyl ester automotive SMC from CSP, GF epoxy balsa/PVC foam wind blades from GE, carbon fiber (CF) epoxy wind blade laminated spar caps from GE, and GF/CF epoxy hybrid assembly from John Deere. Processing the waste composite samples into 1-2” shreds. Packaging the shredded composites into bulk sacks on international shipping pallets for shipment to KUG in Forst (Lausitz), Germany. Pyrolysis of the shredded composites under controlled conditions designed for each polymer system. Collecting samples of the gas and char for analysis. Shipping the char containing the CF/GF back to the US for the next steps of testing the fibers and developing protocols for sustainable re-use of the fibers in composite applications.

36 MATERIALS SCIENCE↗