Optimizing Alabama’s CO 2 Storage in Shelby County (Project OASIS) Milestone 6.0: Evaluation of Class VI Readiness

Introduction. Project OASIS is approximately 30 miles southeast of Birmingham, Alabama, and approximately 5 miles north-northwest of Alabama Power Company's Plant Gaston. Geologically, the Project area is in the Alabama fold and thrust belt province. This work builds on the initiatives of the Southeast Regional Carbon Utilization and Storage Acceleration Partnership (SECARB-USA, DE-FE0031830) that identified nearly 500 million metric tonnes of CO 2 emitted on an annual basis that is not collocated with prospective storage geology (the Coastal Plain of the Southeastern US in this context). This observation suggests costly investments in connective infrastructure (e.g., pipelines) or exploratory well drilling campaigns to identify CO 2 storage opportunities in under explored areas. While not traditionally thought of for saline storage, these studies suggest that storage prospects in the Valley and Ridge Province occur in relatively flat lying structural panels between thrust faults. For the Project OASIS region, available geologic studies related to hydrocarbon exploration suggest that Cambro-Ordovician carbonates and Cambrian clastic units offer multiple potential storage intervals, and that regional confining systems are present, such as the tectonically thickened Floyd-Parkwood Shale. The Project OASIS surface property is owned by a timber and land stewardship company, The Westervelt Company, Inc., who worked with the Project Team to select and prepare adequate sites for geologic assessment. The purpose of drilling the Westover Stratigraphic Test Well #2 was to collect geologic data to model the feasibility of commercial scale CO 2 injection and storage in an under explored region. This initiative benefits the regions emitters as the data generated from this study can inform their own internal decision making. The field program included geological and geophysical evaluations, reservoir engineering analyses, and risk assessments. This report evaluates existing data, as well as a variety of modeling scenarios to evaluate project readiness. Importantly, the impact of this study is not limited to Alabama as there are numerous large emitters throughout Appalachia, in similar geologic settings, contemplating their decarbonization options.

20 FOSSIL-FUELED POWER PLANTS↗

CarbonSAFE Phase II: Optimizing Alabama’s CO 2 Storage in Shelby County, Alabama (Project OASIS), Milestone M3 - Site Specific Drilling Report

The Phase II Storage Complex Feasibility project, entitled "Optimizing Alabama's CO 2 Storage in Shelby County, Alabama (Project OASIS)," is a part of the DOE/NETL's CarbonSAFE initiative. The Project is managed by the Southern States Energy Board (SSEB), and includes participation from Advanced Resources International, Inc. (ARI), Crescent Resource Innovation, Southern Company, Alabama A&M University, Auburn University, and Oklahoma State University. Project OASIS is working to establish the foundation for a commercial-scale geologic storage complex for CO 2 captured from Plant Gaston (home of the National Carbon Capture Center) and surrounding industrial sources of CO 2 located in Shelby County, Alabama. The Project objectives are: • Demonstrate that the subsurface saline formations at the storage complex can store commercial volumes of CO 2 safely and permanently. • Develop a comprehensive Community Benefits Plan. • Develop the infrastructure framework for a CO 2 storage hub. • Develop a rigorous risk registry and to conduct a comprehensive risk assessment. • Develop a monitoring plan. • Develop a comprehensive site characterization plan to support an Underground Injection Control Class VI Permit in a future Phase III program. • Evaluate the commercial viability of the project. Project OASIS is about 30 miles southeast of Birmingham, Alabama within a geologic province called the Valley and Ridge (Figure 1.1). The Valley and Ridge Province comprises a sequence of Paleozoic carbonate and clastic rocks that underwent structural deformation during the Alleghanian Orogeny. Storage prospects occur in relatively flat lying structural panels located between thrust faults. Available geologic studies related to hydrocarbon exploration suggest that Cambro-Ordovician carbonates and Cambrian clastic units offer multiple potential storage intervals, and that regional confining systems are present, such as the tectonically thickened Floyd-Parkwood Shale. The surface property is owned by a timber and land stewardship company, The Westervelt Company, Inc., who worked with the Project Team to select and prepare adequate sites for geologic assessment. The purpose of drilling the Westover Stratigraphic Test Well #2 was to collect geologic data to model the feasibility of commercial scale CO 2 injection and storage. This includes geological and geophysical evaluations, reservoir engineering analyses, and risk assessments.

20 FOSSIL-FUELED POWER PLANTS↗

Optimizing Alabama’s CO 2 Storage in Shelby County (Project OASIS), Task 5.0 Deliverable: Infrastructure Assessment Report

The “Optimizing Alabama’s CO 2 Storage in Shelby County: Project OASIS” CarbonSAFE Phase II Project seeks to build on regional data sets that demonstrate that the subsurface within Shelby County, Alabama has the potential to store commercial volumes of CO 2 safely, permanently, and economically. This work builds on the initiatives of the Southeast Regional Carbon Utilization and Storage Acceleration Partnership (SECARB-USA, DE-FE0031830) that identified nearly 500 million metric tonnes of CO 2 emitted on an annual basis that is not collocated with prospective storage geology (the Coastal Plain of the Southeastern U.S. in this context). This observation suggests costly investments in connective infrastructure (e.g., pipelines) or exploratory well drilling campaigns to identify CO 2 storage opportunities in under explored areas. While not traditionally thought of for saline storage, these studies suggest that storage prospects in the Valley and Ridge Province occur in relatively flat lying structural panels between thrust faults. For the Project OASIS region, available geologic studies related to hydrocarbon exploration suggest that Cambro-Ordovician carbonates and Cambrian clastic units offer multiple potential storage intervals, and that regional confining systems are present, such as the tectonically thickened Floyd-Parkwood Shale. The Project OASIS surface property is owned by a timber and land stewardship company, The Westervelt Company, Inc., who worked with the Project Team to select and prepare adequate sites for geologic assessment.

20 FOSSIL-FUELED POWER PLANTS↗

Optimizing Alabama’s CO 2 Storage in Shelby County (Project OASIS): Task 8 Deliverable 8.0 - Commercialization Plan

The “Optimizing Alabama’s CO 2 Storage in Shelby County: Project OASIS” CarbonSAFE Phase II Project seeks to build on regional data sets that demonstrate that the subsurface within Shelby County, Alabama has the potential to store commercial volumes of CO 2 safely, permanently, and economically. This work builds on the initiatives of the Southeast Regional Carbon Utilization and Storage Acceleration Partnership (SECARB-USA, DE-FE0031830) that identified nearly 500 million metric tonnes of CO 2 emitted on an annual basis from industrial facilities that are not collocated with prospective storage geology (i.e., the Coastal Plain of the Southeastern U.S. in this context). This observation suggests costly investments in connective infrastructure (e.g., pipelines) or exploratory well drilling campaigns are required to identify CO 2 storage opportunities in under-developed areas. While not traditionally thought of for saline storage, these studies suggest that storage prospects in the Valley and Ridge Province of the Appalachian Fold and Thrust Belt occur in relatively flat lying structural panels between thrust faults. For the Project OASIS region, available geologic studies related to hydrocarbon exploration suggest that Cambro-Ordovician carbonates and Cambrian clastic units offer multiple potential storage intervals, and that regional confining systems are present, such as the tectonically thickened Floyd-Parkwood Shale.

20 FOSSIL-FUELED POWER PLANTS↗

Formulation and calibration of two-dimensional constitutive models for composite structures based on panel tests

Steel Plate Concrete (SC) composite members have been widely adopted because of its cost-efficiency and enhanced structural behavior. While researchers have attempted to study its in-plane shear behavior in the past twenty years, very limited number of large-scale pure shear tests were performed due to the challenge of experimental set-up and the availability of facilities. In this paper, a series of uniaxial loading tests and two full-scale pure shear panel tests of SC members were reported, on which the “mechanics-based Membrane Model of SC elements (MM-SC)” is developed. The MM-SC model is based on the fixed-angle crack formulation and the smeared-crack formulation, in which the experimental-based uniaxial constitutive models are implemented, considering the local buckling of faceplate, the tension stiffening of steel plate, the strength degradation of cracked concrete and the confinement effect of concrete. The proposed MM-SC model is subsequently incorporated into the object-oriented software OpenSEES. Finally, the simulation results of proposed model well predict the SC test observations in terms of critical branch points and structural behaviors, including initial stiffness, cracking strength, post-crack stiffness, yield strength, maximum strength, and failure modes.

42 ENGINEERING↗

Experimental Study of the Influence of a Tensile Preload on Thin Woven Composite Laminates Under Impact Loading

In this work, the influence of a tensile preload on the impact behavior of thin woven composite laminates is investigated. These kinds of laminates are usually parts of more complex structures, for example, skins of structural sandwich panels or helicopter blades. These structures are generally subjected to external loads, and can also be impacted in operation. The objective of this study is to identify a correspondence between the preload of the structure and the resulting impact damage. This preliminary work is a first step of a more global study that aims at predicting impact damage in structural composites in order to optimize the design process. Experimental tests are carried out on carbon/epoxy and glass/epoxy mixed thin laminates and on sandwich structures. The samples are loaded uniaxially using a specially designed test rig. The effect of the preload on the impact damage size and shape and the peak load is experimentally quantified and discussed.

36 MATERIALS SCIENCE↗

Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl

Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal and noise transfer properties of CsI:Tl phosphors. Three different CsI:Tl phosphors from two different vendors have been used to produce three system configurations. The performance of each system configuration has been studied in terms of the modulation transfer function (MTF), noise power spectra, and detective quantum efficiency (DQE) in the mammographic energy range. A simple method to determine quantum limited systems in this energy range is also presented. In addition, with aid of monochromatic synchrotron radiation, the effect of iodine characteristic x-rays of the CsI:Tl on the MTF has been determined. A Monte Carlo simulation of the signal transfer properties of the imager is also presented in order to study the stages that degrade the spatial resolution of our current system. The effect of using substrate patterning during the growth of CsI:Tl columnar structure was also studied, along with the effect of CsI:Tl fixed pattern noise due to local variations in the scintillation light. CsI:Tl fixed pattern noise appears to limit the performance of our current system configurations. All the system configurations are quantum limited at 0.23 {mu}C/kg with two of them having DQE (0) equal to 0.57. Active pixel flat panel imagers are shown to be digital x-ray imagers with almost constant DQE throughout a significant part of their dynamic range and in particular at very low exposures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Insulation Strategies of Cross-Laminated Timber Assemblies on Energy Use, Peak Demand, and Carbon Emissions

Cross-Laminated Timber (CLT) panels have many structural benefits but do not have much thermal resistance. We have developed a solution to insulate CLT structures that uses high-performance insulation panels that provide R-values up to R40/inch. The CLT panels are made of layers of wood laminates (three, five, seven or more). The solution replaces some of the wood laminates in the CLT production with the insulation panels in a staggered fashion so that the wood laminates maintain contact throughout the panel, ensuring the CLT panel’s structural integrity. The insulated CLT panels have factory-installed water-resistive barriers reducing the installation time by eliminating installing insulation and water-resistive barriers on site. Per simulations, the CLT/insulation panel achieved code-required insulation levels with commonly available insulation materials. The significance of the thermal mass of CLT/insulation hybrid building envelopes was quantified by comparing the whole building energy performance and peak demand of traditional low mass and CLT wall assemblies resulting in up to 7% reduction in peak demand for cooling in Knoxville, TN, in a multifamily building. Buildings contribute over 40 percent of carbon emissions. The proposed CLT/insulation hybrid building envelope addresses both operational and embodied carbon by having high thermal resistances due to the embedded insulation sections and eliminating the use of high embodied carbon materials such as steel and concrete. The carbon benefit is estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building a 40% Energy Saving House in the Mixed-Humid Climate

This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar fraction for this home located in Lenoir City, Tennessee, is predicted to be as high as 41%(accounting for both solar PV and the solar water heater). This all-electric home is predicted to use 25 kWh/day based on the one year of measured data used to calibrate a whole-building simulation model. Based on two years of measured data, the roof-mounted 2.2 kWp PV system is predicted to generate 7.5 kWh/day. The 2005 cost to commercially construct ZEH5, including builder profit and overhead, is estimated at about $150,000. This cost - for ZEH5's panelized construction, premanufactured utility wall (ZEHcor), foundation geothermal system, and the addition of the walkout lower level, and considering the falling cost for PV - suggests that the construction cost per ft2 for a ZEH5 two-story will be even more cost-competitive. The 2005 construction cost estimate for a finished-out ZEH5 with 2632 ft2 is $222,000 or $85/ft2. The intention of this report is to help builders and homeowners make the decision to build zero-energy-ready homes. Detailed drawings, specifications, and lessons learned in the construction and analysis of data from about 100 sensors monitoring thermal performance for a one-year period are presented. This information should be specifically useful to those considering structural insulated panel walls and roof, foundation geothermal space heating and cooling, solar water heater and roof-mounted, photovoltaic, grid-tied systems.

14 SOLAR ENERGY↗

Dissipative structures and related methods

Dissipative structures include at least one panel and a cell structure disposed adjacent to the at least one panel having interconnected cells. A deformable material, which may comprise at least one hydrogel, is disposed within at least one interconnected cell proximate to the at least one panel. Dissipative structures may also include a cell structure having interconnected cells formed by wall elements. The wall elements may include a mesh formed by overlapping fibers having apertures formed therebetween. The apertures may form passageways between the interconnected cells. Methods of dissipating a force include disposing at least one hydrogel in a cell structure proximate to at least one panel, applying a force to the at least one panel, and forcing at least a portion of the at least one hydrogel through apertures formed in the cell structure.

36 MATERIALS SCIENCE↗

Nexus EnergyHomes, Frederick, Maryland (Fact Sheet)

With this new home - which achieved the highest rating possible under the National Green Building Standard - Nexus EnergyHomes demonstrated that green and affordable can go hand in hand. The mixed-humid climate builder, along with the U.S. Department of Energy Building America team Partnership for Home Innovation, embraced the challenge to create a new duplex home in downtown Frederick, Maryland, that successfully combines affordability with state-of-the-art efficiency and indoor environmental quality. To limit costs, the builder designed a simple rectangular shape and kept interesting architectural features such as porches outside the building's structure. This strategy avoided the common pitfall of creating potential air leakage where architectural features are connected to the structure before the building is sealed against air infiltration. To speed construction and limit costs, the company chose factory-assembled components such as structural insulated panel walls and floor and roof trusses. Factory-built elements were key in achieving continuous insulation around the entire structure. Open-cell spray foam at the rim joist and attic roofline completed the insulation package, and kept the heating, ventilating, and air-conditioning system in conditioned space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Whole-House Solutions Case Study: Nexus EnergyHomes, Frederick, Maryland

With this new home—which achieved the highest rating possible under the National Green Building Standard—Nexus EnergyHomes demonstrated that green and affordable can go hand in hand. The mixed-humid climate builder, along with the U.S. Department of Energy Building America team Partnership for Home Innovation, embraced the challenge to create a new duplex home in downtown Frederick, Maryland, that successfully combines affordability with state-of-the-art efficiency and indoor environmental quality. To limit costs, the builder designed a simple rectangular shape and kept interesting architectural features such as porches outside the building’s structure. This strategy avoided the common pitfall of creating potential air leakage where architectural features are connected to the structure before the building is sealed against air infiltration. To speed construction and limit costs, the company chose factory-assembled components such as structural insulated panel walls and floor and roof trusses. Factory-built elements were key in achieving continuous insulation around the entire structure. Open-cell spray foam at the rim joist and attic roofline completed the insulation package, and kept the heating, ventilating, and air-conditioning system in conditioned space.

affordable↗

A fluid-structure interaction solver for investigating torsional galloping in solar-tracking photovoltaic panel arrays

Solar-tracking photovoltaic arrays are susceptible to aeroelastic fluttering during high-wind events. This dynamic fluttering behavior can grow in amplitude until the panels enter an unstable mode known as torsional galloping which can lead to panel failure or total array destruction. To better understand the physics of the torsional galloping phenomenon and to inform the discussion around panel design and recommended panel stow positions during high wind events, a fluid-structure interaction solver composed of a simulated atmospheric boundary layer with simplified panel structural responses was designed. The simulation choices and features of this solver were informed by the geometry and physical properties of an experimental panel array known to exhibit torsional galloping behavior during hind-wind events. Furthermore, these simulations revealed that the torsional galloping instability is driven by a combination of cyclic vortex shedding from the sun-facing side of the panel and the elastic properties of the torque tube linking the panel assemblies. Testing different stow angles across a range of wind speeds indicates that panels are generally more stable when stowed at negative angles where the leading edge is closer to the ground, hypothesized to be due to ground-blocking effects. These results are supplemented by a discussion of stability trends noted during testing and possible implications when considering multi-row array interactions.

14 SOLAR ENERGY↗

Thermal Integrity Assessment of Building Envelopes of Experimental Houses Using Infrared Thermography

Zero Energy Building Research Alliance, or ZEBRAlliance, is a joint DOE-ORNL-construction industry initiative to develop and demonstrate new energy efficiency technologies for residential buildings, as well as fine-tune and integrate existing technologies, to lower energy costs. Construction of residential envelopes, the diaphragms that separate the inside from outdoors, can have enormous impact on whole-building energy usage. Consequently, post-construction thermal integrity assessment of the building envelopes in the experimental ZEBRAlliance homes is an integral part of the research and development cycle. Nondestructive infrared (IR) thermography provides a relatively easy and quick means of inspecting the experimental homes for thermal bridging, insulation imperfections, moisture penetration, air leakage, etc. Two experimental homes located in Oak Ridge, TN were inspected using IR thermography. The homes are designed with two different envelope systems: (i) Structural Insulated Panels (SIP home) consisting of an insulating foam core sandwiched between oriented strand boards, and (ii) Optimal Value Framing (OVF home) using innovatively spaced wood studs, which are designed to minimize the amount of wood framing, reduce thermal bridging, and lower material costs. IR thermal imaging was performed from both outside and inside of the homes. In this paper, IR images of roof and wall sections of the homes are presented and discussed with respect to identification of areas of thermal bridging and any insulation deficiencies.

09 BIOMASS FUELS↗

Super Energy Efficiency Design (S.E.E.D.) Home Evaluation

This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the 'Super Energy Efficient Design' (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressiveenergy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short termtesting, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Super Energy Efficient Design (S.E.E.D.) Home Evaluation

This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the “Super Energy Efficient Design” (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanford Single-Shell Tank and Double-Shell Tank Integrity Programs - 16390

Waste at Hanford is stored in 149 single-shell tanks and 28 double-shell tanks. Concerns related to aging radioactive waste storage facilities throughout the DOE complex led to Brookhaven National Laboratory (BNL) developing guidelines for structural integrity programs for tank systems. The committee of experts who developed these guidelines is commonly known as the Tank Structural Integrity Panel (TSIP). The DOE has subsequently adopted these guidelines, and requires site operators to have a program consistent with them. The Double-Shell Tank (DST) integrity is maintained with a variety of activities such as ultrasonic and visual inspections, chemistry controls, corrosion monitoring and structural analyses methods. In October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of 241-AY-102 was leaking. WRPS contracted a panel of experts from industry and academia to provide advice and recommendations for the DST Integrity Program. The panel focused on three concerns: - No Early warning - Determine why the existing DST Integrity Program did not predict a primary tank failure or provide early warning of the pending failure. - Program improvements - Recommend activities to either predict a primary tank failure or increase the probability of early warning. - Forensic recommendations - The panel provided additional recommendations regarding forensic assessment of Tank 241-AY-102 (AY-102) to facilitate a conclusion on why the leak occurred. WRPS has prepared a response to the concerns of the panel coupled with recommendations for project action to strengthen the DST Integrity Program [4]. The purpose of this DST Integrity Improvement Plan is to translate the recommendations to specific project activities that are technically and practically responsive. To improve the understanding of the Single-Shell Tank (SST) integrity, WRPS, the Department of Energy-Office of River Protection tank operations contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009. An expert panel on SST integrity, consisting of various subject matter experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration. In late 2010, seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, also known as the Tri-Party Agreement. The change package identified two phases of work for SST integrity. The initial phase, which was completed in 2015, was focused on efforts to envelope the integrity of the tanks. It was divided into two primary areas of investigation: structural integrity and leak integrity. If necessary, based on the outcome from the initial work, a second phase would be focused on further definition of the integrity of the tanks and liners. The two combined phases are designed to support the formal integrity assessment of the Hanford SSTs in 2018 by an Independent Qualified Registered Professional Engineer. This paper will summarize the current status of the DST and SST Integrity Programs and discuss the ongoing efforts to improve these programs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗