Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Rapid and Simultaneous Characterization of Drug Conjugation in Heavy and Light Chains of a Monoclonal Antibody Revealed by High-Resolution Ion Mobility Separations in SLIM

Antibody-drug conjugates (ADCs) have recently gained traction in the biomedical community due to their promise for human therapeutics and an alternative to chemotherapy for cancer. Crucial metrics for ADC efficacy, safety, and selectivity are their drug-antibody ratios (DARs). However, DAR characterization (i.e., determining the average number of conjugated drugs on the antibody) through analytical methods remains challenging due to the heterogeneity of drug conjugation as well as the numerous post-translational modifications possible in the monoclonal antibody. In this work, we report on the use of high-resolution ion mobility spectrometry separations in our structures for lossless ion manipulations coupled to mass spectrometry (SLIM IMS-MS) platform for the rapid and simultaneous characterization of the drug load profile (i.e., stoichiometric distribution of the number of conjugated drugs present on the mAb), determination of the weighted average DAR in both the heavy and light chains of a model antibody-drug conjugate, and calculation of the overall DAR of the ADC. After chemical reduction of the ADC and a subsequent 31.5 meter SLIM IMS separation the various drug bound antibody species could be well resolved for both chains. Furthermore, we also show that higher resolution separations were possible with SLIM IMS as compared to ones performed on a commercially available (~1 meter) drift tube IMS-MS platform. Interestingly, additional gas-phase substructures become evident with longer path length SLIM IMS, potentially providing insight related to how drug conjugation may alter the structural properties of a monoclonal antibody and thus affect its overall potency and/or selectivity for a given antigen. We expect high-resolution SLIM IMS separations will augment the existing toolbox for ADC characterization, particularly for structural confirmation to enable the rapid optimization of DAR for a given ADC and thus better understand its potential toxicity and potency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Preprocessing Tool for Enhanced Ion Mobility–Mass Spectrometry-Based Omics Workflows

The ability to improve the data quality of ion mobility–mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Further, other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.

59 BASIC BIOLOGICAL SCIENCES↗

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS - CRADA 413 (Final Report)

Developing new technologies that enhance our abilities to identify molecular signatures is important for the health of the public, the environment, and national security. Deploying these novel technologies requires multiple stages of validation and evaluation. This project focused on evaluating a technology developed at PNNL named Structures for Lossless Ion Manipulations (SLIM) in the context of a commercially available ion mobility mass spectrometer instrument from Agilent Technologies. There is a benefit to integrating the recently developed SLIM module into a real-world instrument platform. Data from the combined instrument will provide new standards for characterizing samples using ion mobility. These standards, related to both the drift time of ions and their resulting collisional cross sections (CCS) will be of value in characterizing samples from both humans and environmental samples, such as soil microbiomes. Because no previous instrument has been designed and implemented to simultaneously analyze the same sample in both constant and oscillating drift fields, the project will provide a new research capability that will support research in a wide variety of applications. The evaluation approach included measuring the resolving power, mass range, sensitivity, and accuracy of two SLIM variations (constant and oscillating fields). Although SLIM performed similarly to the commercial instrument in terms of sensitivity, mass range, and accuracy the resolving power of SLIM far exceeded that of the commercially-available instrument. This validation will provide critically useful data to our commercial partners which they can use to reach informed decisions on the advantages of the SLIM technology such as the outstanding performance and the low cost of manufacturing.

42 ENGINEERING↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS

Integrate a combined Structures of Lossless Ion Manipulations (SLIM) module that incorporates both constant (not time-varying) field (CF) and oscillatory (time-varying) field (OF) IM separation stages into an Agilent 6560 IM-QTOF mass spectrometer system. Once the SLIM module has been integrated into the Agilent system, its performance will be evaluated using a variety of different samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗