Search NASA⌕ Search

SEARCH · Search NASA

Results for “sub-micron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dynamic Evolution of Mass and Physical Properties of Atmospheric Organic Aerosol under Solar Irradiance

Organic aerosol (OA) particles constitute a substantial fraction of sub-micron particulate mass in the atmosphere and play a critical role in climate system. OA undergoes dynamic aging processes in the atmosphere, with photolytic aging induced by ultraviolet solar irradiance being an important yet poorly characterized mechanism. Knowledge gaps persist regarding the role of volatility transformations during photolytic aging on the OA mass decay kinetics and the evolution of climate-relevant properties, such as hygroscopicity, hindering the model evaluation of OA spatiotemporal distributions and atmospheric budgets. In this study, we conduct isothermal photolytic aging experiments on both laboratory-generated secondary organic aerosols and ambient-collected particles from urban Atlanta, utilizing a high-sensitivity Quartz Crystal Microbalance. Our results reveal that photolytic aging reduces 40–66% of the low-volatility OA mass with lifetimes ranging from 8 to 200 hours under solar irradiance, and 44–92% of the photolytic mass loss is through slow evaporation of semi- or intermediate-volatile products, kinetically limited by their volatility. We observe up to ±50% changes in OA hygroscopicity with the transformation of fresh OA to photo-recalcitrant low-volatility products, associated with changes in oxygen-to-carbon ratio and molecular weight. A kinetic model incorporating photolytic volatility transformation provides a cohesive explanation for the observed photolysis-induced changes in mass, volatility, and hygroscopicity. Our results can help constrain model representation of the dynamic evolutions of mass and climate-relevant properties during photolytic aging processes of the ambient OA, improving our understanding of OA atmospheric behavior and climate impact.

Bai, Bin↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Patch-Based Convolutional Neural Networks for Multiple Microstructural Features Detection in FIB-SEM Micrographs of Irradiated Nuclear Fuel

Focused ion beam scanning electron microscopy (FIB-SEM) tomography has increasingly been utilized for acquiring three-dimensional (3D) microstructure features at the sub-micron scale in irradiated nuclear materials. This technique involves sequential ion beam slicing followed by electron beam imaging and compositional mapping using energy dispersive spectroscopy (EDS). Despite its growing use, several challenges persist. These include the time-intensive nature of data collection of EDS data, difficulties in distinguishing between various microstructures, and issues with image alignment. These challenges currently limit the broader application of FIB-SEM tomography in the field. To overcome these limitations, we propose using convolutional neural networks (CNNs) to automate microstructure identification in SEM images. Our study introduces a new framework for identifying microstructures in irradiated U-10Zr (wt. %) metallic fuel with limited annotated data. The framework includes the creation of a reliable annotated dataset with paired SEM and ground truth data from EDS maps, the applications of CNNs for microstructure identification, and the validation of model performance. Specifically, we employed the Segment Anything Model (SAM) to align SEM images with corresponding EDS maps and focused ion beam (FIB) tomography SEM data. We evaluate several models, including Patch-based U-Net, Attention U-Net, and Residual U-Net, finding that patch-based U-Net exhibits superior segmentation performance and consistency. This approach reduces reliance on EDS detectors and aids in accelerating nuclear material analysis process, highlighting the potential of advanced deep learning techniques to improve microstructural understanding in nuclear material. This is the first framework to integrate SAM and Patch-based CNN models for semantic segmentation of irradiated nuclear materials, with potential applicability to other tomography datasets.

36 - MATERIALS SCIENCE↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Assembly of small silica nanoparticles using lipid-tethered DNA ‘bonds’

Single-stranded DNA molecules modified with cholesterol functional groups are physically tethered to silica nanoparticles (diameter 25 nm) that are encapsulated in a lipid bilayer. Such tethering increases the azimuthal mobility of the DNA molecules across the nanoparticle surface and enables nonspecific bonding, eliminating the need for specialized surface chemistries (such as silane or thiol ligands). To induce assembly, double-stranded DNA ‘bridge’ molecules are then added with complementary nucleotides to the DNA ‘anchor’ molecules that are physically tethered to the lipids on the surface of the particles. Assembly is observed to occur at room temperature and without the need for temperature annealing. Using automated liquid handling tools, assemblies are created in high throughput and rapidly characterized using SAXS. It is determined that the relative concentration of DNA-to-silica and the ionic strength of the solution are important parameters that affect the resulting assembly. Analysis of SAXS data is performed using coarse-grained particle dynamics simulations. The results support the spontaneous formation of semi-crystalline particle assemblies by particle condensation, where the interparticle distance is tuned by the sequence of the DNA ‘bridge’ used to link the particles. Crystallinity analysis performed on the resulting simulations, optimized to match SAXS observations, suggest that particle clusters display increased crystallinity in the center of the clusters, but their maximum size remains relatively small (sub-micron) before settling occurs, which limits the extent of crystallization.

Chiang, Huat Thart [Univ. of Washington, Seattle, ↗

Replenishing liquid sheet targets to enable high-intensity high-repetition-rate laser–plasma interactions for ion-beam technology

We report on the development of a robust microfluidic nozzle capable of generating replenishing liquid sheet targets with sub-micron thickness at up to kHz repetition rates, a λ/20 surface flatness over areas of at least 100 μm 2 , and in-vacuum dimensions of 6 × 1.5 mm 2 . The platform was evaluated for stability under hundreds of 4.3 J laser shots at 0.5 Hz and 6 × 10 20 W/cm 2 peak intensity, delivered in burst mode, totaling 2.9 kJ on the target. The key metrics of the platform, including sheet characteristics, nozzle aperture morphology, and proton spectra, showed no measurable degradation in the performance of the liquid sheet platform following this experiment. Beyond its application to ion beam technology, we outline a pathway to further develop the capabilities of the platform into a high-repetition-rate plasma mirror.

depth profiling techniques↗

Printed Targets with Micron-Scale Feature Patterns for the Study of Ablator Defects on OMEGA

As per present models, laser imprint and implosion symmetry are insufficient to account for observed performance degradation of direct-drive cryogenic fusion implosions. More and better data are needed on ablator defects as a source of hydrodynamic instability and mix. To investigate this, a series of OMEGA experimental campaigns is underway to study isolated target defects. Key requirements are systematic variation of the laser intensity and pulse shape at shot, with highly controlled defect type, geometry, and location. Here, given the need for sub-micron resolution and precise registration of multiple features, two-photon polymerization (TPP) printing was identified as an ideal method to fabricate these targets. TPP printing has enabled controlled formation of designed domes, divots, and vacuoles for studying the combined effect of size and proximity of these features on the hydro performance.

Two-photon polymerization printing↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Physical properties, internal structure, and the three‐dimensional petrography of CI chondrites

physical properties and the nature of their breccation, we investigated nine samples of the Ivuna and Orgueil CI chondrites ranging in size from 1 mm to 4 cm in approximate diameter. The combined mass of unique material investigated in this work is 113 g. For our investigations, we use ideal gas pycnometry, 3-D laser scanning, x-ray computed microtomography (μCT), and accompanying digital data extraction techniques. We found that the bulk density of the samples ranged from 1.61 to 2.10 g cm −3 . Larger samples tend to have a lower bulk density. Grain density (ranging from 2.44 to 2.55 g cm −3 ) is significantly less variable than the bulk density in our samples and the quantity of porosity (ranging from 14.6% to 33.8%) is the dominant factor in determining the bulk density of CI chondrite material. Our μCT results show that the visible porosity across all sizes of our CI chondrite samples is in the form of cracks, but these cracks can account for less than two-thirds of the porosity in the CI chondrites. Other porosity is not visible, even at μCT resolutions of 2.7 μm voxel edge −1 and we conclude that it is sub-micron in nature. It is not clear if the cracks seen in our samples are indigenous to the chondrites or are a result of terrestrial processes. We also find that the CI chondrites are excellent examples of the fractal-like nature of brecciation, where clasts can be observed at all scales we imaged. The breccias are composed of sub-equant-shaped and sub-rounded-textured clasts like melt-free impact breccias on other solar system bodies. From our μCT volume and digital data extraction, we determine that the Ivuna CI chondrite breccia is organized: the mostly sub-equant clasts within our ~2 cm chunk of Ivuna have a mean diameter of 1.33 mm and their aligned longest axes define a lineation structure. We speculate that the lineation was imparted after fragmentation of the clasts by slight shear on the parent asteroid which could be the result of seismic-related granular flow or mild non-axial impact-related compaction. These data will help to place returned asteroidal material from asteroids 162173 Ryugu and 101955 Bennu and the CI chondrites into a mutual geological context.

CI chondrite↗

Final Technical Report - Rapid Surface Microanalysis using a Low Temperature Plasma

This project focused on improving our current understanding and scientific knowledge in the area of plasma-surface interactions and plasma assisted material synthesis related to advanced microelectronics and nanotechnology. Current challenges include: controlling the interaction of Low Temperature Plasma (LTP) with a single layer of atoms to manufacture integrated circuits, continued miniaturization of integrated circuits, LTP processing of material surfaces and thin films to enable industrial scale fabrication of advanced microelectronics, synthesis of new materials, nanomaterials, nanotubes, and complex materials, Technology developed in this subtopic is of value to either (i) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at high resolution (micron or sub-micron resolution) rapidly (hours or days rather than years to complete a high-resolution scan of such a large surface area), or (ii) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at relatively low resolution rapidly, then apply algorithms to select spots for micron-scale imaging. Sputtering occurs when particles of a solid material are ejected from its surface by energetic particles from a plasma. While the degradation of the solid material and the subsequent deposition of the ejected material onto vulnerable surfaces are the usual subjects of sputtering studies, plasma science has yet to be combined with sputtering to create new diagnostics devices and systems. Small changes in the design of the plasma discharge device make it possible to create broad plasma beams for rapid scanning or small plasma beams to obtain the distribution of ejected elements with micron resolution. In the high-resolution use, the ion flux is extracted from the gas-discharge plasma and focused by a spherical emission surface to micron sizes onto the target specimen, providing very local sputtering and local elemental analysis. We call this “self-focusing”. The radiation from the excited and ionized sputtered atoms is recorded by a spectrometer through a window and fiberglass cable and analyzed with standard software packages used for optical glow discharge spectroscopy. Computer simulations of beam formation were used to verify and optimize the designs to be tested. A prototype was designed, constructed, and used to start experiments of beam formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of carbonaceous aerosols during TRACER-CAT

Absorbing aerosols (AA) have an important impact on the global radiation budget and cloud properties. The composition and properties of AA can vary substantially throughout the atmosphere, depending on the particle source and the influence of chemical aging. Uncertainties associated with the radiative effects of AA remain substantial. A key contributor to this uncertainty is understanding the extent to which coatings in general, and water uptake especially, alters absorption by AA particles and how this depends on particle composition. We deployed new and existing experimental tools during the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign in Houston, TX as part of the Carbonaceous Aerosols Thrust (CAT) to provide detailed characterization of aerosol optical, chemical, and physical properties. Our TRACER-CAT measurements complemented and expanded on the planned TRACER instrumentation, allowing for more detailed characterization of aerosol properties of relevance to cloud development (a core focus of TRACER), such as the composition of particles that can act as cloud condensation nuclei, than would otherwise be available. Our measurements have allowed for assessment of the relationship(s) between AA optical properties (with a focus on absorption) and the chemical and physical characteristics (including the mixing state of black carbon (BC) containing particles). These field observations occurred in collaboration with Los Alamos National Laboratory in summer 2022 during the TRACER intensive operating period. The instrumentation we co-deployed provided for measurement of (i) multi-wavelength dry aerosol absorption, scattering, and extinction, (ii) the size-dependent composition and abundance of sub-micron aerosol, differentiating between those particles that do and do not contain BC, (iii) BC-specific concentrations and size distributions, (iv) particle size, and (v) the first field measurements at an ARM site of the influence of RH on multi-wavelength absorption by ambient AA. We have leveraged the natural variability of the atmosphere and of aerosol sources in the Houston region to (i) specifically disentangle contributions to light absorption from BC, absorbing organic carbon (brown carbon), and coatings on BC, (ii) characterize the mixing state of BC and assess the factors that give rise to compositional differences between BC-containing and BC-free aerosol, and (iii) establish how water uptake influences absorption and how any such effect depends on particle composition and BC mixing state. Overall, our study contributed to the mission of the Atmospheric System Research program in multiple ways. Through the deployment of complementary, advanced instrumentation for characterization of a wide range of aerosol properties our work helped to maximize the scientific impact of the TRACER campaign. Our work also allowed for development of new insights into the relationship(s) between aerosol composition, hygroscopicity, and the mixing state of BC with aerosol optical properties. Through this, our work has provided knowledge that can improve understanding and model representation of aerosol processes as they affect the Earth’s radiation budget.

54 ENVIRONMENTAL SCIENCES↗

Development of mesopores in superfine grain graphite neutron-irradiated at high fluence

Microstructural changes induced by neutron irradiation of superfine grain graphite G347A (Tokai Carbon, Japan) were examined by nitrogen adsorption at 77K and by three microscopy techniques (SEM, TEM and FIB-SEM tomography). The specimens were irradiated at doses of up to 30 dpa, covering stages before and after the turnaround fluence at three temperatures (300, 450, 750 °C) of their irradiation envelope. The initial graphite densification at low fluences did not produce any detectable effect in the pore size range (<350 nm) measured by gas adsorption. However, graphite irradiated at high fluences, after turnaround, showed severe structural changes. At all three temperatures and high irradiation fluences, gas adsorption revealed significant increase of the volume of narrow mesopores (<5–20nm) and up to five times increase of BET surface area, both in linear relationship with the relative volume expansion. Analysis of microscopy images showed multiplication of fine macropores (>50 nm) at high irradiation fluences and more structural changes on multiple scales, from nanometers to microns. This work demonstrates the unique ability of gas adsorption techniques to analyze open pores with sizes between sub-nanometer and sub-micron in bulk nuclear graphite, with supporting microscopy results.

I. Contescu, Cristian↗

SCILLA mini-Aerosol Mass Spectrometer (mAMS) airborne data

Measurements of non-refractory, sub-micron aerosol composition, namely organic, sulfate, nitrate, chloride, and ammonium aerosols, by a mini- aerosol mass spectrometer (mAMS, Aerodyne Research, Inc.) are reported. The instrument sampled ambient air through 3 different inlets: unperturbed ambient air, a Counter-flow Virtual Impactor (CVI), and an oxidation flow reactor (OFR). Users should consult the Sampling Key for proper interpretation of the data.

and secondary aerosol in air",total_organics,nitra↗

Extinction and scattering by several types of silicate sphere of radius 0.05-1.0 micron, for the wavelength range 0.21-50 microns.

The exact calculation of scattering and absorption by various sub-micron sized silicate spheres is presented here, using accurately determined optical constants in the wavelength range from 50 to 0.21 microns. The extinction features near 10 and 20 microns for various samples are discussed. It is found that the ratio of peak extinction at 20 microns to that at 10 microns is constant for small particles up to 0.4-micron radius, but is less for particles of 1-micron radius. The ratio of maximum extinction in the ultraviolet to that at 10 microns decreases with increasing particle size.

Bromage, G. E.↗

The effect of microstructure on the fracture toughness of titanium alloys

The high-strength titanium alloys are widely used in aircraft and aerospace structures due to their high strength to density ratios. In such applications, the fracture toughness rather than the strength is often the factor which requires larger size sections and lower useful payloads. The response of the strength and toughness of titanium alloys was analyzed generally without regard to the fracture mode or the effect of microstructure on the fracture mechanisms. Research on the fracture mechanisms in aluminum alloys and steels showed that the toughness may be improved by decreasing the sizes of inclusions and sub-micron precipitates. An investigation was conducted to study the fracture mechanisms in titanium alloys which may lead to suggestions for the improvement of the fracture toughness without a corresponding loss in strength.

Vanstone, R. H.↗

Colour dependence of zodiacal light models

Colour models of the zodiacal light in the ecliptic have been calculated for both dielectric and metallic particles in the sub-micron and micron size range. Two colour ratios were computed, a blue ratio and a red ratio. The models with a size distribution proportional to s to the -2.5 power ds (where s is the particle radius) generally show a colour close to the solar colour and almost independent of elongation. Especially in the blue colour ratio there is generally no significant dependence on the lower cutoff size (0.1-1 micron). The main feature of absorbing particles is a reddening at small elongations. The models for size distributions proportional to s to the -4 power ds show larger departures from solar colour and more variation with model parameters. Colour measurements, including red and near infra-red, therefore are useful to distinguish between flat and steep size spectra and to verify the presence of slightly absorbing particles.

Giese, R. H.↗

Ferromagnetic phases of lunar fines and breccias - Electron magnetic resonance spectra of Apollo 16 samples

Electron magnetic resonance measurements have been made at 9 GHz and at temperatures from 1.2 to 400 K and 35 GHz (300 K) on samples of fines and breccias from Apollo 11-16. Unsorted Apollo 16 fines (less than 1 mm) have Delta H (average) = 580 G and specific intensities that have the same range as fines from the other Apollo collections. The magnetic properties of the 'characteristic' resonance are not in accord with those of iron particles. On the bases of the properties of the 'characteristic' resonance as a function of temperature and Apollo site, laboratory heat treatments on synthetic materials and lunar crystalline rocks and a comparison with the 'characteristic' resonance of the resonance spectra of breccia specimens for which iron particle sizes have been determined from other measurements, it is suggested that some fraction (about 20%) of the 'characteristic' resonance is due to sub-micron particles of ferric oxide phases.

Weeks, R. A.↗