Search NASA⌕ Search

SEARCH · Search NASA

Results for “sub-micron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Uncertainty-aware particle segmentation for electron microscopy at varied length scales

Electron microscopy is indispensable for examining the morphology and composition of solid materials at the sub-micron scale. To study the powder samples that are widely used in materials development, scanning electron microscopes (SEMs) are increasingly used at the laboratory scale to generate large datasets with hundreds of images. Parsing these images to identify distinct particles and determine their morphology requires careful analysis, and automating this process remains challenging. In this work, we enhance the Mask R-CNN architecture to develop a method for automated segmentation of particles in SEM images. We address several challenges inherent to measurements, such as image blur and particle agglomeration. Moreover, our method accounts for prediction uncertainty when such issues prevent accurate segmentation of a particle. Recognizing that disparate length scales are often present in large datasets, we use this framework to create two models that are separately trained to handle images obtained at low or high magnification. By testing these models on a variety of inorganic samples, our approach to particle segmentation surpasses an established automated segmentation method and yields comparable results to the predictions of three domain experts, revealing comparable accuracy while requiring a fraction of the time. These findings highlight the potential of deep learning in advancing autonomous workflows for materials characterization.

36 MATERIALS SCIENCE↗

Imaging the Meissner effect in hydride superconductors using quantum sensors

By directly altering microscopic interactions, pressure provides a powerful tuning knob for the exploration of condensed phases and geophysical phenomena. Here, the megabar regime represents an interesting frontier, in which recent discoveries include high-temperature superconductors, as well as structural and valence phase transitions. However, at such high pressures, many conventional measurement techniques fail. Here we demonstrate the ability to perform local magnetometry inside a diamond anvil cell with sub-micron spatial resolution at megabar pressures. Our approach uses a shallow layer of nitrogen-vacancy colour centres implanted directly within the anvil; crucially, we choose a crystal cut compatible with the intrinsic symmetries of the nitrogen-vacancy centre to enable functionality at megabar pressures. We apply our technique to characterize a recently discovered hydride superconductor, CeH 9 . By performing simultaneous magnetometry and electrical transport measurements, we observe the dual signatures of superconductivity: diamagnetism characteristic of the Meissner effect and a sharp drop of the resistance to near zero. By locally mapping both the diamagnetic response and flux trapping, we directly image the geometry of superconducting regions, showing marked inhomogeneities at the micron scale. Our work brings quantum sensing to the megabar frontier and enables the closed-loop optimization of superhydride materials synthesis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Patch-Based Convolutional Neural Networks for Multiple Microstructural Features Detection in FIB-SEM Micrographs of Irradiated Nuclear Fuel

Focused ion beam scanning electron microscopy (FIB-SEM) tomography has increasingly been utilized for acquiring three-dimensional (3D) microstructure features at the sub-micron scale in irradiated nuclear materials. This technique involves sequential ion beam slicing followed by electron beam imaging and compositional mapping using energy dispersive spectroscopy (EDS). Despite its growing use, several challenges persist. These include the time-intensive nature of data collection of EDS data, difficulties in distinguishing between various microstructures, and issues with image alignment. These challenges currently limit the broader application of FIB-SEM tomography in the field. To overcome these limitations, we propose using convolutional neural networks (CNNs) to automate microstructure identification in SEM images. Our study introduces a new framework for identifying microstructures in irradiated U-10Zr (wt. %) metallic fuel with limited annotated data. The framework includes the creation of a reliable annotated dataset with paired SEM and ground truth data from EDS maps, the applications of CNNs for microstructure identification, and the validation of model performance. Specifically, we employed the Segment Anything Model (SAM) to align SEM images with corresponding EDS maps and focused ion beam (FIB) tomography SEM data. We evaluate several models, including Patch-based U-Net, Attention U-Net, and Residual U-Net, finding that patch-based U-Net exhibits superior segmentation performance and consistency. This approach reduces reliance on EDS detectors and aids in accelerating nuclear material analysis process, highlighting the potential of advanced deep learning techniques to improve microstructural understanding in nuclear material. This is the first framework to integrate SAM and Patch-based CNN models for semantic segmentation of irradiated nuclear materials, with potential applicability to other tomography datasets.

36 - MATERIALS SCIENCE↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Assembly of small silica nanoparticles using lipid-tethered DNA ‘bonds’

Single-stranded DNA molecules modified with cholesterol functional groups are physically tethered to silica nanoparticles (diameter 25 nm) that are encapsulated in a lipid bilayer. Such tethering increases the azimuthal mobility of the DNA molecules across the nanoparticle surface and enables nonspecific bonding, eliminating the need for specialized surface chemistries (such as silane or thiol ligands). To induce assembly, double-stranded DNA ‘bridge’ molecules are then added with complementary nucleotides to the DNA ‘anchor’ molecules that are physically tethered to the lipids on the surface of the particles. Assembly is observed to occur at room temperature and without the need for temperature annealing. Using automated liquid handling tools, assemblies are created in high throughput and rapidly characterized using SAXS. It is determined that the relative concentration of DNA-to-silica and the ionic strength of the solution are important parameters that affect the resulting assembly. Analysis of SAXS data is performed using coarse-grained particle dynamics simulations. The results support the spontaneous formation of semi-crystalline particle assemblies by particle condensation, where the interparticle distance is tuned by the sequence of the DNA ‘bridge’ used to link the particles. Crystallinity analysis performed on the resulting simulations, optimized to match SAXS observations, suggest that particle clusters display increased crystallinity in the center of the clusters, but their maximum size remains relatively small (sub-micron) before settling occurs, which limits the extent of crystallization.

Chiang, Huat Thart [Univ. of Washington, Seattle, ↗

Replenishing liquid sheet targets to enable high-intensity high-repetition-rate laser–plasma interactions for ion-beam technology

We report on the development of a robust microfluidic nozzle capable of generating replenishing liquid sheet targets with sub-micron thickness at up to kHz repetition rates, a λ/20 surface flatness over areas of at least 100 μm 2 , and in-vacuum dimensions of 6 × 1.5 mm 2 . The platform was evaluated for stability under hundreds of 4.3 J laser shots at 0.5 Hz and 6 × 10 20 W/cm 2 peak intensity, delivered in burst mode, totaling 2.9 kJ on the target. The key metrics of the platform, including sheet characteristics, nozzle aperture morphology, and proton spectra, showed no measurable degradation in the performance of the liquid sheet platform following this experiment. Beyond its application to ion beam technology, we outline a pathway to further develop the capabilities of the platform into a high-repetition-rate plasma mirror.

depth profiling techniques↗

Printed Targets with Micron-Scale Feature Patterns for the Study of Ablator Defects on OMEGA

As per present models, laser imprint and implosion symmetry are insufficient to account for observed performance degradation of direct-drive cryogenic fusion implosions. More and better data are needed on ablator defects as a source of hydrodynamic instability and mix. To investigate this, a series of OMEGA experimental campaigns is underway to study isolated target defects. Key requirements are systematic variation of the laser intensity and pulse shape at shot, with highly controlled defect type, geometry, and location. Here, given the need for sub-micron resolution and precise registration of multiple features, two-photon polymerization (TPP) printing was identified as an ideal method to fabricate these targets. TPP printing has enabled controlled formation of designed domes, divots, and vacuoles for studying the combined effect of size and proximity of these features on the hydro performance.

Two-photon polymerization printing↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Physical properties, internal structure, and the three‐dimensional petrography of CI chondrites

physical properties and the nature of their breccation, we investigated nine samples of the Ivuna and Orgueil CI chondrites ranging in size from 1 mm to 4 cm in approximate diameter. The combined mass of unique material investigated in this work is 113 g. For our investigations, we use ideal gas pycnometry, 3-D laser scanning, x-ray computed microtomography (μCT), and accompanying digital data extraction techniques. We found that the bulk density of the samples ranged from 1.61 to 2.10 g cm −3 . Larger samples tend to have a lower bulk density. Grain density (ranging from 2.44 to 2.55 g cm −3 ) is significantly less variable than the bulk density in our samples and the quantity of porosity (ranging from 14.6% to 33.8%) is the dominant factor in determining the bulk density of CI chondrite material. Our μCT results show that the visible porosity across all sizes of our CI chondrite samples is in the form of cracks, but these cracks can account for less than two-thirds of the porosity in the CI chondrites. Other porosity is not visible, even at μCT resolutions of 2.7 μm voxel edge −1 and we conclude that it is sub-micron in nature. It is not clear if the cracks seen in our samples are indigenous to the chondrites or are a result of terrestrial processes. We also find that the CI chondrites are excellent examples of the fractal-like nature of brecciation, where clasts can be observed at all scales we imaged. The breccias are composed of sub-equant-shaped and sub-rounded-textured clasts like melt-free impact breccias on other solar system bodies. From our μCT volume and digital data extraction, we determine that the Ivuna CI chondrite breccia is organized: the mostly sub-equant clasts within our ~2 cm chunk of Ivuna have a mean diameter of 1.33 mm and their aligned longest axes define a lineation structure. We speculate that the lineation was imparted after fragmentation of the clasts by slight shear on the parent asteroid which could be the result of seismic-related granular flow or mild non-axial impact-related compaction. These data will help to place returned asteroidal material from asteroids 162173 Ryugu and 101955 Bennu and the CI chondrites into a mutual geological context.

CI chondrite↗

Dry etching of epitaxial InGaAs/InAlAs/InAlGaAs structures for fabrication of photonic integrated circuits

A dry etching process to transfer the pattern of a photonic integrated circuit design for high-speed laser communications is described. The laser stack under consideration is a 3.2-µm-thick InGaAs/InAlAs/InAlGaAs epitaxial structure grown by molecular beam epitaxy. The etching was performed using Cl2-based inductively-coupled-plasma and reactive-ion-etching (ICP-RIE) reactors. Four different recipes are presented in two similar ICP-RIE reactors, with special attention paid to the etched features formed with various hard mask compositions, in-situ passivations, and process temperatures. The results indicate that it is possible to produce high-aspect-ratio features with sub-micron separation on this multilayer structure. Additionally, the results of the etching highlight the tradeoffs involved with the corresponding recipes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The EIC accelerator: design highlights and project status

The design of the electron-ion collider (EIC) at Brookhaven National Laboratory is well underway, aiming at a peak electron-proton luminosity of 10e+34 cm^-1·sec^-1. This high luminosity, the wide center-of-mass energy range from 29 to 141 GeV (e-p) and the high level of polarization require innovative solutions to maximize the performance of the machine, which makes the EIC one of the most challenging accelerator projects to date. The complexity of the EIC will be discussed, and the project status and plans will be presented.

43 PARTICLE ACCELERATORS↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

In order to prevent emittance growth during long stores of the proton beam at the future Electron-Ion Collider (EIC), we need to have some mechanism to provide fast cooling of the dense proton beams. One promising method is coherent electron cooling (CeC), which uses an electron beam to both ?measure? the positions of protons within the bunch and then apply energy kicks which tend to reduce their longitudinal and transverse actions. In this work, we discuss the under- lying physics of this process. We then discuss simulations which constrain the electrons to move only longitudinally in order to perform fast optimizations and long-term track- ing of the bunch evolution, and benchmark these results against fully 3D codes. Additionally, we discuss practical challenges, including the necessity of a high-quality elec- tron beam and sub-micron alignment of the electrons and protons.

Deitrick, K.↗

Machine Learning for Predictive Performance Analysis in Charged Particle Beam Tools

Imaging methods driven by probes, electrons, and ions have played a dominant role in modern science and engineering. Opportunities for machine vision and AI that focus on consumer problems like driving and feature recognition, are now presenting themselves for automating aspects of the scientific processes. This proposal aims to enable and drive discovery in ultra-low energy implantation by taking advantage of faster processing, flexible control and detection methods, and architecture-agnostic workflows that will result in higher efficiency and shorter scientific development cycles. Custom microscope control, collection and analysis hardware will provide a framework for conducting novel in situ experiments revealing unprecedented insight into surface dynamics at the nanoscale. Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low energy ion implants can be achieved by either lowering the column voltage, or decelerating ions using bias – while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found that is due to lattice enrichment with high stopping power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way to much lower implantation energies, while maintaining high spatial resolution.

47 OTHER INSTRUMENTATION↗

Final Technical Report - Rapid Surface Microanalysis using a Low Temperature Plasma

This project focused on improving our current understanding and scientific knowledge in the area of plasma-surface interactions and plasma assisted material synthesis related to advanced microelectronics and nanotechnology. Current challenges include: controlling the interaction of Low Temperature Plasma (LTP) with a single layer of atoms to manufacture integrated circuits, continued miniaturization of integrated circuits, LTP processing of material surfaces and thin films to enable industrial scale fabrication of advanced microelectronics, synthesis of new materials, nanomaterials, nanotubes, and complex materials, Technology developed in this subtopic is of value to either (i) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at high resolution (micron or sub-micron resolution) rapidly (hours or days rather than years to complete a high-resolution scan of such a large surface area), or (ii) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at relatively low resolution rapidly, then apply algorithms to select spots for micron-scale imaging. Sputtering occurs when particles of a solid material are ejected from its surface by energetic particles from a plasma. While the degradation of the solid material and the subsequent deposition of the ejected material onto vulnerable surfaces are the usual subjects of sputtering studies, plasma science has yet to be combined with sputtering to create new diagnostics devices and systems. Small changes in the design of the plasma discharge device make it possible to create broad plasma beams for rapid scanning or small plasma beams to obtain the distribution of ejected elements with micron resolution. In the high-resolution use, the ion flux is extracted from the gas-discharge plasma and focused by a spherical emission surface to micron sizes onto the target specimen, providing very local sputtering and local elemental analysis. We call this “self-focusing”. The radiation from the excited and ionized sputtered atoms is recorded by a spectrometer through a window and fiberglass cable and analyzed with standard software packages used for optical glow discharge spectroscopy. Computer simulations of beam formation were used to verify and optimize the designs to be tested. A prototype was designed, constructed, and used to start experiments of beam formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of carbonaceous aerosols during TRACER-CAT

Absorbing aerosols (AA) have an important impact on the global radiation budget and cloud properties. The composition and properties of AA can vary substantially throughout the atmosphere, depending on the particle source and the influence of chemical aging. Uncertainties associated with the radiative effects of AA remain substantial. A key contributor to this uncertainty is understanding the extent to which coatings in general, and water uptake especially, alters absorption by AA particles and how this depends on particle composition. We deployed new and existing experimental tools during the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign in Houston, TX as part of the Carbonaceous Aerosols Thrust (CAT) to provide detailed characterization of aerosol optical, chemical, and physical properties. Our TRACER-CAT measurements complemented and expanded on the planned TRACER instrumentation, allowing for more detailed characterization of aerosol properties of relevance to cloud development (a core focus of TRACER), such as the composition of particles that can act as cloud condensation nuclei, than would otherwise be available. Our measurements have allowed for assessment of the relationship(s) between AA optical properties (with a focus on absorption) and the chemical and physical characteristics (including the mixing state of black carbon (BC) containing particles). These field observations occurred in collaboration with Los Alamos National Laboratory in summer 2022 during the TRACER intensive operating period. The instrumentation we co-deployed provided for measurement of (i) multi-wavelength dry aerosol absorption, scattering, and extinction, (ii) the size-dependent composition and abundance of sub-micron aerosol, differentiating between those particles that do and do not contain BC, (iii) BC-specific concentrations and size distributions, (iv) particle size, and (v) the first field measurements at an ARM site of the influence of RH on multi-wavelength absorption by ambient AA. We have leveraged the natural variability of the atmosphere and of aerosol sources in the Houston region to (i) specifically disentangle contributions to light absorption from BC, absorbing organic carbon (brown carbon), and coatings on BC, (ii) characterize the mixing state of BC and assess the factors that give rise to compositional differences between BC-containing and BC-free aerosol, and (iii) establish how water uptake influences absorption and how any such effect depends on particle composition and BC mixing state. Overall, our study contributed to the mission of the Atmospheric System Research program in multiple ways. Through the deployment of complementary, advanced instrumentation for characterization of a wide range of aerosol properties our work helped to maximize the scientific impact of the TRACER campaign. Our work also allowed for development of new insights into the relationship(s) between aerosol composition, hygroscopicity, and the mixing state of BC with aerosol optical properties. Through this, our work has provided knowledge that can improve understanding and model representation of aerosol processes as they affect the Earth’s radiation budget.

54 ENVIRONMENTAL SCIENCES↗

Development of mesopores in superfine grain graphite neutron-irradiated at high fluence

Microstructural changes induced by neutron irradiation of superfine grain graphite G347A (Tokai Carbon, Japan) were examined by nitrogen adsorption at 77K and by three microscopy techniques (SEM, TEM and FIB-SEM tomography). The specimens were irradiated at doses of up to 30 dpa, covering stages before and after the turnaround fluence at three temperatures (300, 450, 750 °C) of their irradiation envelope. The initial graphite densification at low fluences did not produce any detectable effect in the pore size range (<350 nm) measured by gas adsorption. However, graphite irradiated at high fluences, after turnaround, showed severe structural changes. At all three temperatures and high irradiation fluences, gas adsorption revealed significant increase of the volume of narrow mesopores (<5–20nm) and up to five times increase of BET surface area, both in linear relationship with the relative volume expansion. Analysis of microscopy images showed multiplication of fine macropores (>50 nm) at high irradiation fluences and more structural changes on multiple scales, from nanometers to microns. This work demonstrates the unique ability of gas adsorption techniques to analyze open pores with sizes between sub-nanometer and sub-micron in bulk nuclear graphite, with supporting microscopy results.

I. Contescu, Cristian↗