Search NASA⌕ Search

SEARCH · Search NASA

Results for “submillimeter wave detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Bolometric detector systems for IR and mm-wave space astronomy

Recent developments in bolometric detector systems for millimeter and submillimeter wave space astronomy are described. Current technologies meet all the requirements for the high frequency instrument onboard the cosmic background radiation anisotropy satellite/satellite for the measurement of background anisotropies (COBRAS/SAMBA) platform. It is considered that the technologies that are currently being developed will significantly reduce the effective time constant and/or the cooling requirements of bolometric detectors. These technologies lend themselves to the fabrication of the large format arrays required for the Far Infrared and Submillimeter Space Telescope (FIRST). The scientific goals and detector requirements of the COBRAS/SAMBA platform that will use infrared bolometers are reviewed and the baseline detector system is described, including the feed optics, the infrared filters, the cold amplifiers and the warm readout electronics.

Church, S. E.↗

THz Instruments for Space Exploration

THz heterodyne spectrometers, capable of providing spectral resolution of >106 and detection sensitivity in the parts-per-billion range, provide a unique capability for space exploration. The exact operating frequency and technology for the instrument is driven largely by the science that is being investigated along with pragmatic concerns for mass and power requirements. These instruments are examples of highly complex systems that involve design, integration and testing of diverse technologies such as THz cryogenic detectors, optical elements, and microwave and submillimeter-wave components. This paper will review some of the advanced microwave and submillimeter-wave technologies that are being developed to create the next generation of THz instruments for space exploration.

Mehdi, Imran↗

Submillimeter wave detection with superconducting tunnel diodes

Superconductor-Insulator-Superconductor (SIS) diodes are the detector elements in the most sensitive heterodyne receivers available from 100 to 500 GHz. SIS mixers are the front end of radio astronomical systems around the world. SIS mixer technology is being extended to 1 THz and higher frequencies for eventual use on spaceborne astronomical experiments. Here is a short review of submillimeter SIS mixers. The role of impedance matching in the proper design of an SIS mixer is described. A variety of methods for achieving good impedance match at submillimeter frequencies are presented. The experimental state of the submillimeter SIS mixer art is described and summarized.

Wengler, Michael J.↗

A wide-band monolithic quasi-optical power meter for millimeter- and submillimeter-wave applications

A novel monolithic power meter has been developed for submillimeter-wave applications (100 GHz to 10 THz). The detector is a large-area bismuth bolometer integrated on a 1.2-micron-thick dielectric membrane. This approach results in a wide-band, high-responsivity detector. The power meter is simple to fabricate, is inexpensive, and can be easily calibrated using a low-frequency network. Quasi-optical measurements at 90, 140, and 240 GHz show that the bolometer is polarization-independent and could be modeled by a simple transmission line model. Absolute power measurements at 90, 140, and 240 GHz show a + or - 5 percent accuracy and agree well with a calibrated Anritsu power meter at 90 GHz. Potential application areas are power calibration, antenna coupling efficiency measurements, and absolute power measurements from solid-state devices and far-infrared lasers at submillimeter wavelengths. Absolute output power measurements on a 220-280 GHz tripler using the quasi-optical power meter are presented as an application example.

Ling, Curtis C.↗

Sensors and detectors in NASA's future missions

Advances in electronics are responsible for major improvements in NASA's sensing and detection capabilities for future space missions. Technologies such as charge-transfer devices, tunable diode lasers, millimeter and submillimeter wave solid-state receiver components, large-scale circuit integration, new electronic materials and processing techniques, and novel detector electronics are contributing to the goal of a tenfold increase in the capacity of data collection from future platforms and will be used for space exploration and utilization.

Rubin, B.↗

Using Quasiparticle Poisoning To Detect Photons

According to a proposal, a phenomenon associated with excitation of quasiparticles in certain superconducting quantum devices would be exploited as a means of detecting photons with exquisite sensitivity. The phenomenon could also be exploited to perform medium-resolution spectroscopy. The proposal was inspired by the observation that Coulomb blockade devices upon which some quantum logic gates are based are extremely sensitive to quasiparticles excited above the superconducting gaps in their leads. The presence of quasiparticles in the leads can be easily detected via the charge states. If quasiparticles could be generated in the leads by absorption of photons, then the devices could be used as very sensitive detectors of electromagnetic radiation over the spectral range from x-rays to submillimeter waves. The devices in question are single-Cooper-pair boxes (SCBs), which are mesoscopic superconducting devices developed for quantum computing. An SCB consists of a small superconducting island connected to a reservoir via a small tunnel junction and connected to a voltage source through a gate capacitor. An SCB is an artificial two-level quantum system, the Hamiltonian of which can be controlled by the gate voltage. One measures the expected value of the charge of the eigenvectors of this quantum system by use of a radio-frequency single-electron transistor. A plot of this expected value of charge as a function of gate voltage resembles a staircase that, in the ideal case, consists of steps of height 2 e (where e is the charge of one electron). Experiments have shown that depending on the parameters of the device, quasiparticles in the form of "broken" Cooper pairs present in the reservoir can tunnel to the island, giving rise to steps of 1 e. This effect is sometimes called "poisoning." Simulations have shown that an extremely small average number of quasiparticles can generate a 1-e periodic signal. In a device according to the proposal, this poisoning would be turned to advantage. Depending on the wavelength, an antenna or other component would be used to couple radiation into the reservoir, wherein the absorption of photons would break Cooper pairs, thereby creating quasiparticles that, in turn, would tunnel to the island, creating a 1-e signal. On the basis of conservative estimates of device parameters derived from experimental data and computational simulations that fit the data, it has been estimated that the noise equivalent power of a device according to the proposal could be as low as 6 10(exp -22) W/Hz(exp 1/2). It has also been estimated that the spectroscopic resolution (photon energy divided by increment of photon energy) of such a device in visible light would exceed 100.

Echternach, Pierre↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

Imaging Antenna Structure For Submillimeter Wavelengths

Integrated-circuit antenna structure contains two-dimensional array of antennas and antenna reflectors. In receiving mode, each antenna acts as part of detector for one picture element in millimeter- or submillimeter-wavelength imaging radar system. Millimeter-wave imaging system used to view objects through fog, smoke, or smog with resolution intermediate between microwave and visible-light imaging systems. Antenna elements, supports, and reflectors made by integrated-circuit techniques. Structures fabricated on front and back substrates separately. Substrates then joined. Inexpensive way to provide large number of small antenna elements required for imaging, all mounted rigidly in way that does not degrade operation.

Rebeiz, G.↗

Four lunar astronomical observatories - Concepts developed in the NASA 90-day study for the Human Exploration Initiative

A number of astrophysical observatory concepts were studied under the overall direction of the NASA Astrophysics Division in support of NASA's 90-day study of the Human Exploration Initiative. The four observatory concepts described here were investigated at JPL. In three of them, interferometric techniques would be used to acquire high resolution synthetic aperture images in several different parts of the electromagnetic spectrum: in the UV/visible near infrared; the submillimeter; and the very low frequency (1 to 30 MHz region). The fourth is a gravitational wave detector which uses laser optical interferometry to measure the strains induced by the passage of a gravitational wave. The observatory concepts reflect the constraints on lunar surface science deployment anticipated for the Human Exploration Initiative in the period 2002 through 2015.

Cutts, James A.↗

Far infrared all-sky survey

An all-sky survey at submillimeter waves is examined. Far-infrared all-sky surveys were performed using high-thoroughput bolometric detectors from a one-meter balloon telescope. Based on the large-bodied experience obtained with the original all-sky survey telescope, a number of radically different approaches were implemented. Continued balloon measurements of the spectrum of the cosmic microwave background were performed.

Richards, Paul L.↗

Carbon-Nanotube Schottky Diodes

Schottky diodes based on semiconducting single-walled carbon nanotubes are being developed as essential components of the next generation of submillimeter-wave sensors and sources. Initial performance predictions have shown that the performance characteristics of these devices can exceed those of the state-of-the-art solid-state Schottky diodes that have been the components of choice for room-temperature submillimeter-wave sensors for more than 50 years. For state-of-the-art Schottky diodes used as detectors at frequencies above a few hundred gigahertz, the inherent parasitic capacitances associated with their semiconductor junction areas and the resistances associated with low electron mobilities limit achievable sensitivity. The performance of such a detector falls off approximately exponentially with frequency above 500 GHz. Moreover, when used as frequency multipliers for generating signals, state-of-the-art solid-state Schottky diodes exhibit extremely low efficiencies, generally putting out only micro-watts of power at frequencies up to 1.5 THz. The shortcomings of the state-of-the-art solid-state Schottky diodes can be overcome by exploiting the unique electronic properties of semiconducting carbon nanotubes. A single-walled carbon nanotube can be metallic or semiconducting, depending on its chirality, and exhibits high electron mobility (recently reported to be approx.= 2x10(exp 5)sq cm/V-s) and low parasitic capacitance. Because of the narrowness of nanotubes, Schottky diodes based on carbon nanotubes have ultra-small junction areas (of the order of a few square nanometers) and consequent junction capacitances of the order of 10(exp -18) F, which translates to cutoff frequency >5 THz. Because the turn-on power levels of these devices are very low (of the order of nano-watts), the input power levels needed for pumping local oscillators containing these devices should be lower than those needed for local oscillators containing state-of-the-art solid-state Schottky diodes.

Manohara, Harish↗

International Symposium on Space Terahertz Technology, 1st, University of Michigan, Ann Arbor, Mar. 5, 6, 1990, Proceedings

Problems, proposed solutions, and recent results related to the development of solid-state oscillators, detectors, mixers, diode multipliers, and antennas at THz frequencies are addressed. Individual topics considered include: submillimeter heterodyne remote sensing of upper atmospheric gases, planar dipole array antenna with an elliptical lens, twin slot antenna structures integrated with microbolometer detectors for 94-GHz imaging. Also discussed are: quantum-well and quantum-barrier diodes for generating submillimeter wave power, planar Schottky barrier mixer diodes for space applications at submillimeter wavelengths, GaAs Schottky barrier varactor diodes for submillimeter wavelength power generation, planar doped barrier devices for subharmonic mixers.

Ulaby, Fawwaz↗

NASA Tech Briefs, December 2010

Topics include: Coherent Frequency Reference System for the NASA Deep Space Network; Diamond Heat-Spreader for Submillimeter-Wave Frequency Multipliers; 180-GHz I-Q Second Harmonic Resistive Mixer MMIC; Ultra-Low-Noise W-Band MMIC Detector Modules; 338-GHz Semiconductor Amplifier Module; Power Amplifier Module with 734-mW Continuous Wave Output Power; Multiple Differential-Amplifier MMICs Embedded in Waveguides; Rapid Corner Detection Using FPGAs; Special Component Designs for Differential-Amplifier MMICs; Multi-Stage System for Automatic Target Recognition; Single-Receiver GPS Phase Bias Resolution; Ultra-Wideband Angle-of-Arrival Tracking Systems; Update on Waveguide-Embedded Differential MMIC Amplifiers; Automation Framework for Flight Dynamics Products Generation; Product Operations Status Summary Metrics; Mars Terrain Generation; Application-Controlled Parallel Asynchronous Input/Output Utility; Planetary Image Geometry Library; Propulsion Design With Freeform Fabrication (PDFF); Economical Fabrication of Thick-Section Ceramic Matrix Composites; Process for Making a Noble Metal on Tin Oxide Catalyst; Stacked Corrugated Horn Rings; Refinements in an Mg/MgH2/H2O-Based Hydrogen Generator; Continuous/Batch Mg/MgH2/H2O-Based Hydrogen Generator; Strain System for the Motion Base Shuttle Mission Simulator; Ko Displacement Theory for Structural Shape Predictions; Pyrotechnic Actuator for Retracting Tubes Between MSL Subsystems; Surface-Enhanced X-Ray Fluorescence; Infrared Sensor on Unmanned Aircraft Transmits Time-Critical Wildfire Data; and Slopes To Prevent Trapping of Bubbles in Microfluidic Channels.

Source record↗

The Impact of Standard Semiconductor Fabrication Processes on Polycrystalline Nb Thin Film Surfaces

Polycrystalline superconducting Nb thin films are extensively used for submillimeter and millimeter transmission line applications and, less commonly, used in microwave kinetic inductance detector (MKID) applications. The microwave and mm-wave loss in these films is impacted, in part, by the presence of surface nitrides and oxides. In this study, glancing incidence x-ray diffraction was used to identify the presence of niobium nitride and niobium monoxide surface layers on Nb thin films which had been exposed to chemicals used in standard photolithographic processing. A method of mitigating the presence of ordered niobium monoxide surface layers is presented. Furthermore, we discuss the possibility of using glancing incidence x-ray diffraction as a non-destructive diagnostic tool for evaluating the quality of Nb thin films used in MKIDs and transmission lines. For a given fabrication process, we have both the x-ray diffraction data of the surface chemistry and a measure of the mm-wave and microwave loss, the latter being made in superconducting resonators.

superconducting films↗